manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SMA
  6. •
  7. Inverter
  8. •
  9. SMA Sunny Island 4548-US User manual

SMA Sunny Island 4548-US User manual

Other manuals for Sunny Island 4548-US

1

This manual suits for next models

1

Other SMA Inverter manuals

SMA CL-PSU-1-SP Operating and safety instructions

SMA

SMA CL-PSU-1-SP Operating and safety instructions

SMA 2000HF User manual

SMA

SMA 2000HF User manual

SMA SUNNY BOY 5.5-JP User manual

SMA

SMA SUNNY BOY 5.5-JP User manual

SMA SUNNY TRIPOWER X 20-US User manual

SMA

SMA SUNNY TRIPOWER X 20-US User manual

SMA SUNNY MINI CENTRAL 6000TL User manual

SMA

SMA SUNNY MINI CENTRAL 6000TL User manual

SMA SUNNY CENTRAL 250U User manual

SMA

SMA SUNNY CENTRAL 250U User manual

SMA SUNNY BOYSTORAGE User manual

SMA

SMA SUNNY BOYSTORAGE User manual

SMA Sunny Tripower Series Manual

SMA

SMA Sunny Tripower Series Manual

SMA 1200 User manual

SMA

SMA 1200 User manual

SMA POWER+ Installation guide

SMA

SMA POWER+ Installation guide

SMA SUNNY TRIPOWER 5000TL User manual

SMA

SMA SUNNY TRIPOWER 5000TL User manual

SMA SUNNY MINI CENTRAL 4600A User manual

SMA

SMA SUNNY MINI CENTRAL 4600A User manual

SMA SUNNY BOY 5000TL User manual

SMA

SMA SUNNY BOY 5000TL User manual

SMA MLX Series User manual

SMA

SMA MLX Series User manual

SMA SUNNY BOY 1.5 User manual

SMA

SMA SUNNY BOY 1.5 User manual

SMA NR-STP-DC-CON-1012 Operating and safety instructions

SMA

SMA NR-STP-DC-CON-1012 Operating and safety instructions

SMA SUNNY TRIPOWER 5.0 SMART ENERGY User manual

SMA

SMA SUNNY TRIPOWER 5.0 SMART ENERGY User manual

SMA STP50-40-IS-xx-11 Series User manual

SMA

SMA STP50-40-IS-xx-11 Series User manual

SMA SUNNY BOY3000TL-US User manual

SMA

SMA SUNNY BOY3000TL-US User manual

SMA 600-US User manual

SMA

SMA 600-US User manual

SMA SUNNY BOY 6000TL?US User manual

SMA

SMA SUNNY BOY 6000TL?US User manual

SMA SB3.0-1SP-US-40 User manual

SMA

SMA SB3.0-1SP-US-40 User manual

SMA NR-STP-AC-CON Operating and safety instructions

SMA

SMA NR-STP-AC-CON Operating and safety instructions

SMA SUNNY TRIPOWER CORE1 User manual

SMA

SMA SUNNY TRIPOWER CORE1 User manual

Popular Inverter manuals by other brands

Fourgroup Easy use and Programming Handbook

Fourgroup

Fourgroup Easy use and Programming Handbook

Velleman PI300M user manual

Velleman

Velleman PI300M user manual

Sungrow SG350HX-US user manual

Sungrow

Sungrow SG350HX-US user manual

WilTec 61897 Operation manual

WilTec

WilTec 61897 Operation manual

Simplicity LANDLORD 316 product manual

Simplicity

Simplicity LANDLORD 316 product manual

Santak SMAX 3000 user manual

Santak

Santak SMAX 3000 user manual

ATON RA.Store-3 user manual

ATON

ATON RA.Store-3 user manual

ZIEHL-ABEGG FXET4AMQ operating instructions

ZIEHL-ABEGG

ZIEHL-ABEGG FXET4AMQ operating instructions

Tektronix CFG250 Operator's manual

Tektronix

Tektronix CFG250 Operator's manual

Champion 200989 Operator's manual

Champion

Champion 200989 Operator's manual

Vanner 20-500 Series owner's manual

Vanner

Vanner 20-500 Series owner's manual

GE GEP user manual

GE

GE GEP user manual

MULTIQUIP GDP-5H Operation and parts manual

MULTIQUIP

MULTIQUIP GDP-5H Operation and parts manual

Astrel Group Power Reducer Installation and instruction manual

Astrel Group

Astrel Group Power Reducer Installation and instruction manual

GoWISE PS1007 user manual

GoWISE

GoWISE PS1007 user manual

Promate PM13500D ES Operator's manual

Promate

Promate PM13500D ES Operator's manual

Mastervolt WHISPER 3.5M3000 RPM user manual

Mastervolt

Mastervolt WHISPER 3.5M3000 RPM user manual

Mitsubishi Electric FR-A7AZ instruction manual

Mitsubishi Electric

Mitsubishi Electric FR-A7AZ instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SI4548-US-10 / SI6048-US-10
SUNNY ISLAND 4548-US / 6048-US
The SMA Sunny Island 4548-US and 6048-US inverters are based on proven off-grid technology and feature industry
leading power output. A maximum efficiency of 96 percent ensures peak production, which results in reduced diesel usage
in rural communities. More flexible sizing allows for simplified system planning. And, with multicluster technology, up to 12
Sunny Islands can be integrated into off-grid power systems up 110 kW in size.
The efficient off-grid manager
SUNNY ISLAND 4548-US / 6048-US
Durable
•Extremeoverloadcapability
•OptiCool™activetemperature
management system
•5-yearstandardwarranty
Flexible
•ForSunnyIslandsystemsfrom4.5
to 100 kW
•Single, split-phase and three-phase
operation, connectable in parallel
and modularly expandable
•ACandDCcoupling
Simple
•Easycommissioningwiththe
“QuickConfigurationGuide”
•Completeoff-gridmanagement
•Excellentforgrid-tiedbattery
back up
Efficient
•Maximumefficiencyof96%
•CECefficiencyof94.5%and94%
•Stateofchargecalculation
•Intelligentbatterymanagement
for maximum battery life
Technical data Sunny Island
4548-US
Sunny Island
6048-US
AC output (loads)
Ratedgridvoltage/ACvoltagerange 120 V/105 V – 132 V 120 V/105 V – 132 V
Rated frequency / frequency range (adjustable) 60 Hz/55 Hz ... 65 Hz 60 Hz/55 Hz ... 65 Hz
ACpower(at25°C/at40°C)for3hours 5000 W/4000 W 6000 W/5000 W
Rated power (@ Unom, fnom/25°C/@cosϕ=1) 4500 W 5750 W
ACpowerat25°Cfor30min/1min/3s 5300 W / 8400 W / 11000 W 7000 W / 8400 W / 11000 W
Rated current / max. output current (peak) 37.5 A/180 A for approx. 60 ms 48 A/180 A for approx. 60 ms
Total harmonic factor output voltage / power factor with rated power 3%/-1…+1 3%/-1…+1
AC input (PV array or grid)
Ratedinputvoltage/ACinputvoltagerange 120 V/80 V – 150 V 120 V/80 V – 150 V
Rated input frequency / allowable input frequency range 60 Hz/54 Hz ... 66 Hz 60 Hz/54 Hz ... 66 Hz
Max.ACinputcurrent/adjustable 56A/0A…56A 56A/0A…56A
Max.ACinputpower 6.7 kW 6.7 kW
Battery DC input
Ratedinputvoltage/DCvoltagerange 48 V/41 V – 63 V 48 V/41 V – 63 V
Max.batterychargingcurrent/DCratedchargingcurrent 100 A / 85 A 130 A / 110 A
Battery type / battery capacity range Lead,NiCd/100Ah…10000Ah Lead,NiCd/100Ah…10000Ah
Chargecontrol IUoU charge procedure with automatic full
charge and equalization charge
IUoU charge procedure with automatic full
charge and equalization charge
E󹢶ciency / self-consumption
Max.e󹻯ciency/CECe󹻯ciency 96%/94.5% 96%/94%
Self-consumption without load / standby 25 W/4 W 25 W/4 W
Protective devices
DCreversepolarityprotection/DCfuse ●/● ●/●
ACshort-circuit/ACoverload ●/● ●/●
Overtemperature/batterydeepdischarge ●/● ●/●
General data
Dimensions(W/H/D) 467 / 612 / 235 mm
(18.4 / 24.1 / 9.3 inch)
467 / 612 / 235 mm
(18.4 / 24.1 / 9.3 inch)
Weight 63 kg / 139 lb 63 kg / 139 lb
Operatingtemperaturerange -25°C…+60°C/-13°F…+122°F -25°C…+60°C/-13°F…+122°F
Features / function
Operationanddisplay/multi-functionrelay Internal / 2 Internal / 2
Degreeofprotection(accordingtoIEC60529) indoors(NEMA1) indoors(NEMA1)
Three-phase systems / parallel connection ●/● ●/●
Integrated bypass / multicluster operation —/● —/●
State of charge calculation / full charge / equalization charge ●/●/● ●/●/●
Integrated soft start / generator support ●/● ●/●
Battery temperature sensor / data cable ●/● ●/●
Warranty 5 years 5 years
Certi󹻭catesandapprovals www.SMA-Solar.com www.SMA-Solar.com
Accessories
Battery cable / battery fuse ○/○ ○/○
Interface (RS 485 / Multicluster PB) ○/○ ○/○
Extendedgeneratorstart“GenMan” ○ ○
Load-shedding protection / battery current measurement ○/○ ○/○
●Standardfeature ○Optionalfeature —Notavailable
Type designation SI4548-US-10 SI6048-US-10
SMA America, LLC
Toll Free +1 888 4 SMA USA
www.SMA-America.com
SUNNYIS4548_6048US-DUS131719 Sunny Island, OptiCool, and SMA are registered trademarks of SMA Solar Technology AG. Text and figures comply with the state of the art applicable when printing. Subject to technical changes. We accept no liability for typographical and other errors. Printed on chlorine-free paper.
Three-phase system Split-phase system