SMA SBS3.8-US-10 User manual

SBSxx-US-10-AT-PU-SG-xx-10 | 113822-00.01 | Version 1.0
SBS3.8-US-10 / SBS5.0-US-10 / SBS6.0-US-10
Replacing the PowerUnit
ENGLISH Service Manual ESPAÑOL Instrucciones de servicio técnico
FRANÇAIS Manuel de service

Table of Contents SMA Solar Technology America LLC
Service ManualSBSxx-US-10-AT-PU-SG-xx-102
Table of Contents
1 Information on this Document................................................. 3
1.1 Validity........................................................................................................................ 3
1.2 Target Group.............................................................................................................. 3
1.3 Structure...................................................................................................................... 3
1.4 Levels of warning messages...................................................................................... 3
1.5 Symbols in the Document .......................................................................................... 4
1.6 Typographies in the document.................................................................................. 4
1.7 Designation in the document..................................................................................... 4
2 Safety Information ................................................................... 5
3 Overview of the Enclosure Parts............................................. 7
4 Checking the Firmware Version.............................................. 8
5 Disassembling the Defective Power Unit................................ 9
6 Mounting the New Power Unit ............................................... 12
7 Packaging the Defective Power Unit for Pick-Up .................. 15
8 Contact ...................................................................................... 16
ENGLISH

1 Information on this Document
SMA Solar Technology America LLC
Service Manual SBSxx-US-10-AT-PU-SG-xx-10 3
1 Information on this Document
1.1 Validity
This document is valid for:
• SBS3.8-US-10 (SunnyBoyStorage 3.8-US)
• SBS5.0-US-10 (SunnyBoyStorage 5.0-US)
• SBS6.0-US-10 (SunnyBoyStorage 6.0-US)
1.2 Target Group
The tasks described in this document must only be performed by qualified persons. Qualified
persons must have the following skills:
• Knowledge of how to safely disconnect SMA inverters
• Knowledge of how batteries work and are operated
• Training in how to deal with the dangers and risks associated with installing, repairing and
using electrical devices, batteries and installations
• Training in the installation and commissioning of electrical devices and installations
• Knowledge of all applicable laws, standards and directives
• Knowledge of and compliance with this document and all safety information
• Knowledge of and compliance with the documents of the battery manufacturer with all safety
information
1.3 Structure
This document describes how to replace defective components. This document supplements the
documents that are enclosed with each product and does not replace any locally applicable
standards or directives. Read and observe all documents supplied with the product.
You can find a detailed manual of the product in PDF format at www.SMA-Solar.com.
1.4 Levels of warning messages
The following levels of warning messages may occur when handling the product.
DANGER
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
ENGLISH

1 Information on this Document SMA Solar Technology America LLC
Service ManualSBSxx-US-10-AT-PU-SG-xx-104
NOTICE
Indicates a situation which, if not avoided, can result in property damage.
1.5 Symbols in the Document
Symbol Explanation
Information that is important for a specific topic or goal, but is not
safety-relevant
☐
Indicates a requirement for meeting a specific goal
☑
Desired result
✖
A problem that might occur
1.6 Typographies in the document
Typography Use Example
bold • Messages
• Terminals
• Elements on a user interface
• Elements to be selected
• Elements to be entered
• Connect the insulated
conductors to the terminals
X703:1 to X703:6.
• Enter 10 in the field
Minutes.
>• Connects several elements to be
selected
• Select Settings > Date.
[Button]
[Key]
• Button or key to be selected or
pressed
• Select [Enter].
1.7 Designation in the document
Complete designation Designation in this document
SunnyBoyStorage Inverter, product
SMA Solar Technology America LLC SMA
SMA Solar Technology Canada Inc. SMA
ENGLISH

2 Safety Information
SMA Solar Technology America LLC
Service Manual SBSxx-US-10-AT-PU-SG-xx-10 5
2 Safety Information
This section contains safety information that must be observed at all times when working on or with
the product.
To prevent personal injury and property damage and to ensure long-term operation of the product,
read this section carefully and observe all safety information at all times.
DANGER
Danger to life from electric shock due to live DC cables at the battery.
The DC cables connected to a battery may be live. Touching the DC conductors or the live
components leads to lethal electric shocks.
• Do not touch non-insulated cable ends.
• Do not touch any live components.
• Have the inverter and the battery mounted, installed and commissioned only by qualified
persons with the appropriate skills.
• Observe all safety information of the battery manufacturer.
• Prior to performing any work on the inverter or the battery, disconnect the inverter from all
voltage sources as described in this document.
• Wait five minutes before working on the inverter.
• If an error occurs, have it rectified by qualified persons only.
WARNING
Risk of burns due to electric arcs
Short-circuit currents in the battery can cause heat build-up and electric arcs.
• Disconnect the battery from all voltages sources prior to performing any work on the
battery.
• Observe safety information of the battery manufacturer when working on the battery or
inverter.
CAUTION
Risk of burns from hot surfaces
The surface of the inverter can get very hot. Touching the surface can result in burns.
• Mount the inverter in such a way that it cannot be touched inadvertently.
• Do not touch hot surfaces.
• Wait 30 minutes for the surface to cool sufficiently.
• Observe the safety messages on the inverter.
ENGLISH

2 Safety Information SMA Solar Technology America LLC
Service ManualSBSxx-US-10-AT-PU-SG-xx-106
NOTICE
Damage to the enclosure seal in subfreezing conditions
If you open the product when temperatures are below freezing, the enclosure seals can be
damaged. Moisture can penetrate the product then.
• Only open the product if the ambient temperature is not below 0°C (32°F).
• If a layer of ice has formed on the enclosure seal when temperatures are below freezing,
remove it prior to opening the product (e.g. by melting the ice with warm air). Observe the
applicable safety regulations.
• Do not disassemble the PowerUnit unless the ambient temperature is at least 0°C (32°F)
and conditions are frost-free.
NOTICE
Damage due to sand, dust and moisture ingress
Sand, dust and moisture penetration can damage the product and impair its functionality.
• Only open the product if the humidity is within the thresholds and the environment is free of
sand and dust.
• Do not open the product during a dust storm or precipitation.
• Close tightly all enclosure openings.
• Only use listed rain-tight or liquid-tight conduit fittings to attach the conduits to the product.
• Only disassemble the PowerUnit if a new PowerUnit is already available.
NOTICE
Damage due to cleaning agents
The use of cleaning agents may cause damage to the product and its components.
• Clean the product and all its components only with a cloth moistened with clear water.
NOTICE
Damage to the inverter due to electrostatic discharge
Touching electronic components can cause damage to or destroy the inverter through
electrostatic discharge.
• Ground yourself before touching any component.
ENGLISH

3 Overview of the Enclosure Parts
SMA Solar Technology America LLC
Service Manual SBSxx-US-10-AT-PU-SG-xx-10 7
3 Overview of the Enclosure Parts
A
C
B
D
Figure 1 : Overview of the enclosure parts
Position Designation
A Power Unit
B Connection Unit
C Communication assembly
D Interface module of the battery
ENGLISH

4 Checking the Firmware Version SMA Solar Technology America LLC
Service ManualSBSxx-US-10-AT-PU-SG-xx-108
4 Checking the Firmware Version
1. Activate the user interface of the inverter (see the inverter manual).
2. Log into the user interface as an Installer.
3. Select the menu Device Configuration.
4. Check the installed firmware version. The firmware version must be up to date.
5. Update the firmware to the latest version if it is not up to date. To do this, download the current
update package at www.SMA-Solar.com and select the menu Settings > Perform firmware
update in the overview on the user interface, and load the saved update package and select
[Perform firmware update].
☑ The firmware version is being updated.
6. If the firmware version could not be updated, replace the PowerUnit without the current
firmware version.
ENGLISH

5 Disassembling the Defective Power Unit
SMA Solar Technology America LLC
Service Manual SBSxx-US-10-AT-PU-SG-xx-10 9
5 Disassembling the Defective Power Unit
Prior to disassembling the defective Power Unit, all connections between the Power Unit and the
Connection Unit must be severed. Only then can the Power Unit be removed from the Connection
Unit. All cables connected to the communication assembly can remain plugged in and do not need
to be removed to disassemble the PowerUnit.
Procedure:
1. DANGER
Danger to life due to high voltages
• Disconnect the inverter from voltage sources (see inverter manual).
2. Remove the terminal block with the connected DC
conductors from slot DC-in. To do this, unscrew the
screws using a flat-blade screwdriver (blade width:
4mm (5⁄32in)) and pull the terminal block out of
the slot. While doing so, only touch the terminal
block on the black enclosure.
3. Remove the terminal block with the connected AC
conductors from slot AC-out. To do this, unscrew the
screws using a flat-blade screwdriver (blade width:
4mm (5⁄32in)) and pull the terminal block out of
the slot.
4. If there is a switch and an outlet for secure power
supply operation connected, remove the terminal
block with the connected cable from the SPS slot. To
do this, unscrew the screws using a flat-blade
screwdriver (blade width: 4mm (5⁄32in)) and pull
the terminal block out of the slot.
ENGLISH

5 Disassembling the Defective Power Unit SMA Solar Technology America LLC
Service ManualSBSxx-US-10-AT-PU-SG-xx-1010
5. Pull the ribbon cable connecting the communication
assembly to the PowerUnit out of the
communication assembly.
COM SPS
AC-out
D-IN SPS
A B
M1
X1 X2 M2
ANT.
FCC ID: SVF-KP20
IC: 9440A-KP20
6. Pull the ribbon cable connecting the communication
assembly to the battery interface module out of the
battery interface module.
COM SPS
AC-out
D-IN SPS
A B
M1
X1 X2 M2
ANT.
FCC ID: SVF-KP20
IC: 9440A-KP20
Max. 30V DC
DISPLAY
BAT MFR USB
+
_
1
1
2
7. If the inverter is fitted with a padlock for theft
protection, open the padlock and remove it.
8. Using a Torx screwdriver (TX 25), unscrew the
screw M5x60 which fastens the inverter to the wall
mounting bracket.
9. Unscrew the two screws on the right and left side of
the PowerUnit with a Torx screwdriver (TX25) and
retain together with the washers for later use.
ENGLISH

5 Disassembling the Defective Power Unit
SMA Solar Technology America LLC
Service Manual SBSxx-US-10-AT-PU-SG-xx-10 11
10. Lift to remove the Power Unit out of the wall
mounting bracket, thus separating the Power Unit
from the Connection Unit.
TOP
11. If necessary, remove residual insulation material
from the two connection openings at the top of the
Connection Unit.
ENGLISH

6 Mounting the New Power Unit SMA Solar Technology America LLC
Service ManualSBSxx-US-10-AT-PU-SG-xx-1012
6 Mounting the New Power Unit
1. DANGER
Danger to life due to high voltages
• Disconnect the inverter from voltage sources (see inverter manual).
2. Hook the new Power Unit into the upper recesses of the wall mounting bracket, thus plugging
the Power Unit into the Connection Unit. Make sure that the screw holes on the left and right
sides of the PowerUnit are directly over those of the ConnectionUnit; and the cables
protruding from the PowerUnit must not be pinched.
3. Fasten two screws with washers on the right and left side of the PowerUnit using a Torx
screwdriver (TX25) (torque: 6Nm ± 0.3Nm (53in-lb ± 2.65in-lb)).
4. Secure the inverter to the wall mounting bracket. To
do this, insert the screw M5x60 through the hole on
the left side of the PowerUnit using a Torx
screwdriver (TX25) and screw it into the thread
(torque: 1.7Nm ± 0.3 Nm (15.05in-lb ± 2.65in-
lb)).
5. If the inverter is to be protected against theft, attach a padlock:
• To do this, guide the shackle of the padlock
through the provided hole on the left side of the
Power Unit and close the shackle.
• Keep the key of the padlock in a safe place.
6. Pull the ribbon cable used to connect the
communication assembly to the PowerUnit into the
ConnectionUnit, and plug it into the jack on the
communication assembly.
COM SPS
AC-out
D-IN SPS
A B
M1
X1 X2 M2
ANT.
FCC ID: SVF-KP20
IC: 9440A-KP20
ENGLISH

6 Mounting the New Power Unit
SMA Solar Technology America LLC
Service Manual SBSxx-US-10-AT-PU-SG-xx-10 13
7. Insert the ribbon cable used to connect the
communication assembly to the battery interface
module into the jack on the battery interface module
and lock it.
COM SPS
AC-out
D-IN SPS
A B
M1
X1 X2 M2
ANT.
FCC ID: SVF-KP20
IC: 9440A-KP20
Max. 30V DC
DISPLAY
BAT MFR USB
+
_
1
2
2
8. Plug the terminal block with the connected DC
conductors into slot DC-in in the Connection Unit.
While doing so, only touch the terminal block on the
black enclosure.
9. DANGER
Danger to life due to electric arc
The terminal block must be fastened to the slot with two screws. If the terminal block is not
correctly mounted and comes out of the slot, an electric arc can form. An electric arc can
cause life-threatening injuries.
• Mount the terminal block on the slot as described in the following.
10. Tighten (torque: 1.7Nm ± 0.3 Nm (15.05in-lb ±
2.65in-lb)) the screws of the terminal block using a
flat-blade screwdriver (blade width: 4mm (5⁄32in)).
11. Ensure that the terminal block is securely in place.
ENGLISH

6 Mounting the New Power Unit SMA Solar Technology America LLC
Service ManualSBSxx-US-10-AT-PU-SG-xx-1014
12. Plug the terminal block with the connected AC
conductors into the AC-out slot in the
ConnectionUnit, and tighten (torque: 1.7Nm ± 0.3
Nm (15.05in-lb ± 2.65in-lb)) with a flat-blade
screwdriver (blade width: 4mm (5⁄32in)).
13. If applicable, plug the terminal block with the
connected cable for secure power supply operation
into the SPS slot in the Connection Unit, and tighten
(torque: 1.7Nm ± 0.3 Nm (15.05in-lb ± 2.65in-
lb)) with a flat-blade screwdriver (blade width:
4mm (5⁄32in)).
14. Commission the inverter (see inverter manual). The starting process of the inverter will take up
to 20 minutes since all relevant information is transferred from the ConnectionUnit to the
PowerUnit, and the PowerUnit may also be updated.
15. If the inverter firmware could not be updated prior to replacing the PowerUnit and the inverter
is not yet equipped with the current firmware version, perform a firmware update (see manual
of the inverter).
16. If a firmware update has been carried out, ensure that all parameters have been transferred
correctly and that the inverter feeds grid-compliant current into the utility grid.
ENGLISH

7 Packaging the Defective Power Unit for Pick-Up
SMA Solar Technology America LLC
Service Manual SBSxx-US-10-AT-PU-SG-xx-10 15
7 Packaging the Defective Power Unit for Pick-Up
1. Package the defective Power Unit for pick-up. Use the original packaging of the new Power
Unit for this purpose.
2. Arrange for pick-up by SMA. To do this, contact Service (refer to www.SMA-Solar.com for
contact details).
ENGLISH

8 Contact SMA Solar Technology America LLC
Service ManualSBSxx-US-10-AT-PU-SG-xx-1016
8 Contact
If you have technical problems with our products, please contact the SMAServiceLine. The
following data is required in order to provide you with the necessary assistance:
• Battery inverter:
– Device type
– Serial number
– Firmware version
– Event message
– Mounting location and mounting height
– Optional equipment, e.g. communication products
– Use the name of the system in SunnyPortal (if available)
– Access data for SunnyPortal (if available)
– Special country-specific settings (if available)
• Batteries:
– Type
– Firmware version
– Type of automatic transfer switch (if available)
United States SMA Solar Technology
America LLC
Rocklin, CA
Toll free for USA and US Territories
+1877-MY-SMATech (+1877-697-6283)
International: +1916625-0870
Canada SMA Solar Technology
Canada Inc.
Mississauga
Toll free for Canada / Sans frais pour le Canada :
+1877-MY-SMATech (+1877-697-6283)
México SMA Solar Technology
de México
Mexico City
Internacional: +1 916 625-0870
ENGLISH

Índice
SMA Solar Technology America LLC
Instrucciones de servicio técnico SBSxx-US-10-AT-PU-SG-xx-10 17
Índice
1 Indicaciones sobre este documento ....................................... 18
1.1 Área de validez.......................................................................................................... 18
1.2 Grupo de destinatarios.............................................................................................. 18
1.3 Estructura .................................................................................................................... 18
1.4 Niveles de advertencia.............................................................................................. 18
1.5 Símbolos del documento ........................................................................................... 19
1.6 Marcas de texto en el documento............................................................................ 19
1.7 Denominación en el documento ............................................................................... 19
2 Indicaciones de seguridad ...................................................... 20
3 Imagen de las partes de la carcasa ....................................... 22
4 Comprobación de la versión de firmware............................. 23
5 Desmontaje de la Power Unit averiada................................. 24
6 Montaje de la nueva Power Unit............................................ 27
7 Embalaje y recogida de la Power Unit averiada.................. 30
8 Contacto.................................................................................... 31
ESPAÑOL

1 Indicaciones sobre este documento SMA Solar Technology America LLC
Instrucciones de servicio técnicoSBSxx-US-10-AT-PU-SG-xx-1018
1 Indicaciones sobre este documento
1.1 Área de validez
Este documento es válido para:
• SBS3.8-US-10 (SunnyBoyStorage 3.8-US)
• SBS5.0-US-10 (SunnyBoyStorage 5.0-US)
• SBS6.0-US-10 (SunnyBoyStorage 6.0-US)
1.2 Grupo de destinatarios
Las actividades descritas en este documento deben realizarlas exclusivamente especialistas que
han de contar con esta cualificación:
• Capacidad para desconectar los inversores de SMA de la tensión de manera segura
• Conocimientos sobre los procedimientos y el funcionamiento de las baterías
• Formación sobre cómo actuar ante los peligros y riesgos relativos a la instalación, la
reparación y el manejo de equipos eléctricos, baterías y plantas
• Formación profesional para la instalación y la puesta en marcha de equipos eléctricos y
plantas
• Conocimiento de las leyes, normativas y directivas aplicables
• Conocimiento y seguimiento de este documento y de todas sus indicaciones de seguridad
• Conocimiento y observancia de la documentación del fabricante de la batería y de todas las
indicaciones de seguridad
1.3 Estructura
Este documento describe la sustitución de componentes defectuosos. Este documento es un
complemento de aquellos facilitados con cada producto y no sustituye las normativas y directivas
locales vigentes. Lea y tenga en cuenta los documentos suministrados con el producto.
Encontrará las instrucciones detalladas del producto en formato PDF en www.SMA-Solar.com.
1.4 Niveles de advertencia
Cuando se trate con el producto pueden darse estos niveles de advertencia.
PELIGRO
Representa una advertencia que, de no ser observada, causa la muerte o lesiones físicas graves.
ADVERTENCIA
Representa una advertencia que, de no ser observada, puede causar la muerte o lesiones físicas
graves.
ATENCIÓN
Representa una advertencia que, de no ser observada, puede causar lesiones físicas leves o de
gravedad media.
ESPAÑOL

1 Indicaciones sobre este documento
SMA Solar Technology America LLC
Instrucciones de servicio técnico SBSxx-US-10-AT-PU-SG-xx-10 19
PRECAUCIÓN
Representa una advertencia que, de no ser observada, puede causar daños materiales.
1.5 Símbolos del documento
Símbolo Explicación
Información importante para un tema u objetivo concretos, aunque
no relevante para la seguridad
☐
Requisito necesario para alcanzar un objetivo determinado
☑
Resultado deseado
✖
Posible problema
1.6 Marcas de texto en el documento
Marca de texto Uso Ejemplo
Negrita • Avisos
• Conexiones
• Elementos de una interfaz de
usuario
• Elementos que deben
seleccionarse
• Elementos que deben
introducirse
• Conecte los conductores a
los bornes de X703:1 a
X703:6.
• Introduzca 10 en el campo
Minutos.
>• Une varios elementos que deben
seleccionarse.
• Seleccione Ajustes >
Fecha.
[Botón]
[Tecla]
• Botones o teclas que deben
seleccionarse o pulsarse
• Seleccione [Enter].
1.7 Denominación en el documento
Denominación completa Denominación utilizada en este documento
Sunny Boy Storage Inversor, producto
SMA Solar Technology America LLC SMA
SMA Solar Technology Canada Inc. SMA
ESPAÑOL

2 Indicaciones de seguridad SMA Solar Technology America LLC
Instrucciones de servicio técnicoSBSxx-US-10-AT-PU-SG-xx-1020
2 Indicaciones de seguridad
Este capítulo contiene indicaciones de seguridad que deben observarse siempre en todos los
trabajos que se realizan en el producto y con el producto.
Para evitar daños personales y materiales y garantizar el funcionamiento permanente del
producto, lea detenidamente este capítulo y cumpla siempre las indicaciones de seguridad.
PELIGRO
Peligro de muerte por descarga eléctrica causada por cables de CC bajo
tensión en la batería
Los cables de CC conectados a una batería pueden encontrarse bajo tensión. El contacto con
los conductores de CC o los componentes conductores causa descargas eléctricas que pueden
ser mortales.
• No toque ningún extremo de cable descubierto.
• No toque ningún componente bajo tensión.
• Encargue el montaje, la instalación y la puesta en marcha del inversor y de la batería
únicamente a especialistas con la cualificación adecuada.
• Siga todas las indicaciones de seguridad del fabricante de las baterías.
• Antes de efectuar cualquier trabajo en el inversor y en la batería, desconecte el inversor de
la tensión tal y como se describe en este documento.
• Antes de trabajar en el inversor, espere 5minutos.
• Si se produce un error, deje que lo resuelva exclusivamente un especialista.
ADVERTENCIA
Peligro de quemaduras debido a arcos voltaicos
Las corrientes de cortocircuito de la batería pueden originar subidas de temperatura y arcos
voltaicos.
• Antes de efectuar cualquier trabajo en la batería, esta debe desconectarse de la tensión.
• Al realizar trabajos en la batería y en el inversor tenga en cuenta todas las indicaciones de
seguridad del fabricante de la batería.
ATENCIÓN
Peligro de quemaduras por superficies calientes
La superficie del inversor puede calentarse mucho. Si se toca la superficie, podrían producirse
quemaduras.
• Monte el inversor de manera que no sea posible un contacto accidental con la carcasa.
• No toque la superficie caliente.
• Espere 30 minutos hasta que la superficie se haya enfriado lo suficiente.
• Tenga en cuenta las advertencias del inversor.
ESPAÑOL
This manual suits for next models
2
Table of contents
Languages:
Other SMA Portable Generator manuals
Popular Portable Generator manuals by other brands

Briggs & Stratton
Briggs & Stratton Elite 030209-1 Operator's manual

Kohler
Kohler VOLT VK4X1E owner's manual

cecotec
cecotec TOTALPURE 3000 SMART OZONE instruction manual

Ozotech
Ozotech Poseidon 200 Installation & service manual

Ametek
Ametek 200 Series Quick start guide and safety instructions

DuroStar
DuroStar DS4400 owner's manual