CPVan SM11R User manual

INTERLINKED SMOKE DETECTOR
Quick Reference Guide
SM11R/02-2021/V01
Thank you for purchasing our wireless interlinked smoke
alarm device. Please read this manual carefully to ensure
proper use and store it in a safe place for future reference.
Product Specifications
Power: DC 2*1.5V AA Alkaline or Carbon Zinc battery
Battery Package: Alkaline (LR6、MN1500) or Carbon Zinc
battery (R6P)
Operation Current: <30uA (standby); <70mA (alarm)
Alarm Volume: >85 dB(A) at 3 meters
Alarm Sensitivity: 0.09 - 0.17 dB/m
Low Battery: 2.6 ±0.1 V
Silence Time: approx. 10 minutes
Frequency : 433.92MHz or 868MHz (Customized)
Working distance : Up to 100m (Outdoor open)
Interlinked devices: : Max 30pcs per group
Source/Master smoke alarm sound pattern: BI 0.5s - pause 0.5s
–BI 0.5s –pause 0.5s –BI 0.5s –pause 1.5s, with the red LED
flash, repeat this alarm pattern.
Slave smoke alarm sound pattern: BI 0.1s - pause 0.1s with the
red LED flash and sound, repeat this alarm pattern.
Comply to Standard EN14604:2005/AC:2008

Packing List
1 × Photoelectric smoke alarm
1 × Mounting bracket
1 × Screw Kit
1 × User manual
Installation Instructions
Where to install
1. At first you should install an alarm in the bedroom and
walkway. If there are several bedrooms in the house,
please install an alarm in every bedroom.
2. Install an alarm above the stairway and on every floor of
the house.
3. Smoke, heat and burning things will spread horizontally
after rising to the ceiling, so install the alarm in middle of
the ceiling.
4. If the alarm can not be installed in the middle of the
ceiling, install it keeping 300mm away from the corners .
(see the figure1).
5. If the alarm is installed in the wall, it should keep 100mm
away from the ceiling.
6. If the length of the room or the hall is beyond 30 foot,
you need to install several alarms there.
7. When the wall or ceiling is slanting, the alarm needs to
be installed minimum 500mm away from the highest wall
or ceiling point in the room (see the figure 2).
Figure 1
Figure 2
Locations to Avoid
1. High-humidity areas such as kitchens, and bathrooms;
2. Next to air outlets, fans and central heating;
3. Dusty, dirty areas or areas with insects;
4. High-temperature and easily polluted places;
5. Places with difficult access, making it difficult to operate
the test function;
6. Within 1.5m from lamps;
7. Next to doors or windows;
8. In the top of rooms with sloping roofs, the corner of the

room or other dead-air spaces.
Mounting Alarms
1. Twist off the mounting bracket from the alarm.
2. Put the bracket on the installation position and mark the
screw holes on the ceiling or the wall.
3. Drill two mounting holes in the marked place by an
electric drill (The diameter of the drill hole is 5mm) and
insert two plastic anchor plugs by hammer.
4. Screw the mounting bracket to the ceiling or the wall
(Refer to figure 3).
5. Attach the alarm to the mounting bracket and turn
clockwise to lock the alarm
WARNING: The installation instructions must be followed
strictly in case of any injury.
Figure 3
Test your Alarm
Test the unit to ensure proper operation by pressing the cover,
the alarm will sound if the unit are working well. If no sounds,
you can refer to “Trouble shooting” section for solution.
CAUTION:
1. DO NOT test your alarm using an open flame. This may
damage the smoke alarm, or ignite combustible materials
and start a structural fire.
2. DO NOT stand close to the alarm when the alarm is
sounding. Exposure at close range may be harmful to
your earning, so step away when testing.
3. Weekly Test: test this smoke alarm once a week.
LED Indicators
1. Normal status: Red LED Flashes once every 60 seconds.
2. Test status: Red LED flashes once every second.
3. Hush/Silence mode: Red LED flashes once every 8
seconds.
4. Low Battery status: Red LED flashes once every 60
seconds and 1 beep every 60 seconds.

5. Fault status: the alarm will deliver beeps every 40
seconds.
Silence Mode
During the unit is alarming, you can push the test button, it
will be paused the unit alarming for approx 10 minutes. The
red LED will flash once every 8 seconds, it indicates the
smoke alarm device is running into the silence mode.The
silence feature is to be used only when a known alarm
condition, such as smoke from cooking activates the
alarm.The smoke alarm device will automatically reset after
approximately 10 minutes, if after this period, particles of
combustion are still present, the alarm will sound again.
CAUTION:
Before using the alarm silence (silence), identify the source
of the smoke and be certain a safe condition exists.
Interlinked smoke detector
Radio-interlinked smoke detectors are interlinked through radio-
frequency signals. If one smoke alarm detects fire, all alarms go
off. In the case of
the battery operated radio-interlinked smoke alarms, no wiring is
required at all.
How to create the interlinked network
Step 1: Press the test/silence button on one of these smoke
alarms 4 times, and the green LED will rapidly flash continuously,
indicating it has entered the transmitting mode (valid time: 60
seconds) .
Step 2: Press the test/silence button on the other smoke alarms
twice, and the green LED will slowly flash continuously,
indicating it has entered the receiving mode.
-----If pairing is successful: The green LED of these alarms will
stop flashing.
-----When it is failure: The green light will continue to flash for
60 seconds, and then the red light will stay on for 2 seconds.
How to disabling the interconnect function
Press the test/silence button on the smoke alarms twice and the
green LED will slowly flash continuously still 60 seconds, then
ignore it and it will automatic despairing.
How to silence the alarms in network when alarm
If the smoke alarm detects fire, the device will goes into
Source/Master smoke alarm sound pattern alarmed, and emits the
alarm signal;

When other alarm devices received alarm signal, they will goes
into Slave smoke alarm sound pattern, until the Source/Master
alarm device stopped alarm;
During the unit is alarming, you can find out the Source/Master
smoke alarm , press the Test/Silence button to pause all other
interconnected alarms.
Maintenance and Cleaning
There are a few simple steps you need do to keep it working
properly.
1. Test the alarm once a week.
2. Do not paint the alarm. Paint will seal the vents and
interfere with the sensor’s ability to detect smoke.
3. Never attempt to disassemble the alarm to clean inside.
This will damage the alarm.
Clean the alarm at least once a month to remove dust, dirt,
or debris.
Use a vacuum cleaner with the soft brush, vacuum all sides
and covers of smoke alarm device.
If there is a defective battery or other failures, you can refer
to “Trouble shooting” for solution, if there are still failures
during warranty, you can return to your retailer.
Replaced Battery:
1. The low battery signal can last for maximum 30 days,
please replace the batteries in time to keep it working
properly.
2. Battery required: standard 1.5V AA alkaline batteries.
3. Recommended battery brand:
DURACELL ,Energizer,Golden Peak,GP, etc; if use low
quality battery, it may cause the alarm work false or
reduce service life .
4. Correctly install the poles of the battery.
5. Test your alarms before or after mounting it.
Trouble Shooting
Problem
Method of disposal
The alarm does not
sound when testing
1. Please check whether the batteries be
well assembled according to the Guide
required
Red LED flashes and
the alarm delivers
one beep every 60
seconds
1. The battery is low. Please replace the
batteries as soon as possible.
The alarm delivers
one beep every 40
seconds
1. clean the alarm. please refer to the
“maintenance and cleaning” section.
2. The alarm is malfunctioning. Contact
the retailer to replace it.
Nuisance alarms
triggered
intermittently or
when residents are
cooking, taking
1. Press silence button.
2. Clean the alarm. Please refer to the
“maintenance and cleaning” section.
3. Move the alarm to new location.

Warranty Information
Purchase each new smoke alarm device to be free from
defects in material and workmanship under normal use and
service for a period of 2 years from the date of purchase.
During the specified warranty period, we will repair or
replace, at its discretion any defective Smoke Alarms that
are returned to the retailer. Please include your name,
address and phone number along with a brief description of
what is wrong with the unit. Damage from neglect, abuse or
failure to adhere to any of the enclosed instructions will
result in termination of the warranty, and the unit will not be
replaced or repaired.
This warranty shall not apply to the alarm if it has been
damaged, modified, abused or altered after the date of
purchase or if it fails to operate due to improper maintenance.
The Manufacturer shall have no liability for any personal
injury, property damage or any special, incidental, contingent
or consequential damage of any kind resulting from gas
leakage, smoke, fire or explosion.
showers, etc.
Table of contents
Other CPVan Smoke Alarm manuals
Popular Smoke Alarm manuals by other brands

Bosch
Bosch twinguard user manual

Gentex
Gentex 9000 SERIES installation instructions

System Sensor
System Sensor 2951 Installation and maintenance instructions

Tyco Electronics
Tyco Electronics F08 Installation & programming manual

First Alert
First Alert SA300 user manual

Red Smoke Alarms
Red Smoke Alarms R9 installation instructions

Notifier
Notifier FSC-851 Installation and maintenance instructions

QOLSYS
QOLSYS IQSmoke installation guide

Kidde
Kidde 914 user guide

detectomat
detectomat HDv 300 OS Series Operation and installation manual

Teknim
Teknim TFD 1430 Installation and user manual

Convoy Security
Convoy Security YT202 Installation and maintenance instructions