SCCM20-100 Owner’s Manual
25 to 100 Vdc 40 to 100 Vdc
Short Circuit Current (maximum)
Battery Type ( jumper-selectable)
12 or 24 Vdc; automatically detected
Bulk and Absorption
Voltages (maximum)
for Battery Types
Charging Current (maximum)
20 Adc* (derated to 18 Adc at 60°C)
Temperature Compensation (range)
-5 mV / °C / battery cell*
NOTE: Enabled by removing battery jumper; loads turned off while equalizing
NOTE*: Occurs every 60 days,
or following a low battery load disconnect
Equalization Voltage (maximum)
*Number shown is factory default setting. Consult the battery manufacturer for specific charger
settings. Item is settable with communications interface.
Possible Remedies (perform in order shown)
1) Check battery connections 2) Check PV voltage and connections 3) Allow charger to cool
No LED indicators with PV power available
1) Check battery voltage at controller terminals 2) Check panel voltage at controller terminals
1) Disconnect PV 2) Disconnect battery 3) Disconnect load
4) Reconnect battery 5) Reconnect PV 6) Reconnect load
1) Disconnect loads 2) Charge battery
Charging to wrong voltage
1) Check position of battery selection jumper 2) Check installation of thermistor
Battery Reversal, PV Reversal
Load Disconnect (Automatic Reset)
Low Battery, High Battery, Overload
Load Disconnect (Manual Reset)
Overload (after 3 automatic resets)
Low Battery Load Disconnect
Low Battery Load Reconnect
High Battery Load Disconnect
197 mm (7.8”) x 110 mm (4.3”) x 57 mm (2.2”)
Terminal Size (PV and battery)
NOTE: Larger cables must be used if battery cables exceed 3 m length
NOTE: Battery cables must be twisted together during installation
Battery Sense Required Size
0.33 to 0.08 mm2 (#22 to 28 AWG)
External Protection (recommended)
Followall local codes to select overcurrent
-40°C to 60°C (derated to 18A output from 50
to 60°C)
0 to 95% RH non-condensing
Minimum 100 Ah at C/5 discharge rate
CE, EN 61000-6-1, EN 61000-6-3, IEC/EN 62109-1