Smartharvest SCCM20-100 User manual

For more information on this product, visit www.smartharvestbyoutback.com
1
SCCM20-100
MPPT Charge Controller/Load Manager
Owner’s Manual
NOTE:
Follow instructions in order.
Charge batteries at least once a week.
Use reducers to connect larger wires
to terminals.
1
15 cm
(6”)
15 cm
(6”)
Mount on wall with 4 screws
15 cm (6”) clearance
Do not
get wet
Do not
drop
2
Install battery wires
No battery here
3
Install PV wires
< 20 amps
No PV here
4
0.25 amps < < 20 amps
Install load wires
Do not
open
Do not disconnect
battery while PV is active
Clearance and orientation
Remove
wiring
cover
= 12/24 volts only

SCCM20-100 Owner’s Manual
2
Thermistor
(Battery
Temperature
Sensor )
6
Battery
Voltage
Sense
Wire
5
Jumper inserted at factory
Jumper Removed:
Flooded
Battery Charging
Jumper Inserted:
VRLA Battery Charging
Battery
Selection
Jumper
Connect
thermistor to
positive
battery
terminal
Connect
sense wire to
positive (+)
battery
terminal
7
(on)
(blink
or
flash)
RED
(Warning)
(on)
(blink
or
flash)
YELLOW
(Battery)
(on)
(blink
or
flash)
GREEN
(PV)
OFF
LED
Indicators
Connect
thermistor
wires
Connect
sense
wire
NOTE: Percentages are approximate and are based on battery voltages.
YELLOW
Battery > 90%
Battery > 50%
Battery < 50%
Battery
Critical
< 20%
PV Present
Charging
No PV
GREEN
OK
Disconnect
Battery
Critical
No Error
< 20%
RED

SCCM20-100 Owner’s Manual
3
7Battery Voltage Sensing
3 4 5 6 7 8
1
2
1LED Indicators
2Compartment Cover Screw
3PV Input
4Battery Input
5 Load Output
6 Thermistor (Battery Temperature)
8 Data Communications
CAUTION: Hazard to Equipment
Proprietary adapter is required.
Do not connect directly to computer or Ethernet.
NOTES:
3, 4, and 5: Use flat screwdriver with tip width <6 mm and blade length >50 mm
6and 7: Use flat screwdriver with tip width <3 mm and blade length >50 mm
Caution: Equipment Damage
Symbols
Caution: Risk of Electric Shock
Double or reinforced insulation;
Grounding is unnecessary
Caution: Hot Surface
Refer to operating instructions
When disposing, keep this product
separate from household waste;
recycle this product
Features

SCCM20-100 Owner’s Manual
4
Specifications
Section
Name
12 Vdc
24 Vdc
PV
Controller Type
MPPT
Wattage (maximum)
300 W
600 W
Voc (range)
NOTE
: Will not operate above
85 Vdc
25 to 100 Vdc 40 to 100 Vdc
Vmp (range)
15 to 70 Vdc
27 to 70 Vdc
Short Circuit Current (maximum)
20 Adc
Battery
Battery Type ( jumper-selectable)
Flooded or VRLA
Nominal Voltage
12 or 24 Vdc; automatically detected
Battery Input (range)
9 to 16 Vdc
18 to 32 Vdc
Standby Loss
<3 mAdc
Efficiency (maximum)
97%
Charger
Bulk and Absorption
Voltages (maximum)
for Battery Types
Flooded
VRLA
Flooded
VRLA
Bulk
14.8 Vdc*
14.6 Vdc*
29.6 Vdc*
29.2 Vdc*
Absorb
14.8 Vdc*
14.4 Vdc*
29.6 Vdc*
28.8 Vdc*
Absorb Time
2 hours*
Float Voltage
13.2 Vdc*
13.5 Vdc*
26.4 Vdc*
27.0 Vdc*
Charging Current (maximum)
20 Adc* (derated to 18 Adc at 60°C)
Temperature Compensation (range)
-5 mV / °C / battery cell*
Thermistor
10K NTC
Equalize
NOTE: Enabled by removing battery jumper; loads turned off while equalizing
NOTE*: Occurs every 60 days,
or following a low battery load disconnect
Equalization Voltage (maximum)
15.5 Vdc*
--
31.0 Vdc*
--
Equalization Time
1 hour*
*Number shown is factory default setting. Consult the battery manufacturer for specific charger
settings. Item is settable with communications interface.
Troubleshooting
Problem
Possible Remedies (perform in order shown)
Battery not charging
1) Check battery connections 2) Check PV voltage and connections 3) Allow charger to cool
No LED indicators with PV power available
1) Check battery voltage at controller terminals 2) Check panel voltage at controller terminals
Red LED on
1) Disconnect PV 2) Disconnect battery 3) Disconnect load
4) Reconnect battery 5) Reconnect PV 6) Reconnect load
Red LED flashing
1) Disconnect loads 2) Charge battery
Yellow LED not on
Charge battery
Charging to wrong voltage
1) Check position of battery selection jumper 2) Check installation of thermistor
Section
Name
12 Vdc
24 Vdc
Loads
Minimum Load Size
0.25 Adc
Maximum Output Current
20 Adc
Internal
Protections
Internal Protection
Battery Reversal, PV Reversal
Load Disconnect (Automatic Reset)
Low Battery, High Battery, Overload
Load Disconnect (Manual Reset)
Overload (after 3 automatic resets)
Low Battery Load Disconnect
11.4 Vdc*
22.8 Vdc*
Low Battery Load Reconnect
12.4 Vdc*
24.8 Vdc*
High Battery Load Disconnect
15.0 Vdc
30.0 Vdc
Dimensions
Size
197 mm (7.8”) x 110 mm (4.3”) x 57 mm (2.2”)
Weight
~ 1 kg
Cabling
Terminal Size (PV and battery)
≤ 32 mm2(#4 AWG)
Cable Size (minimum)
Battery
16 mm2 (#6 AWG)
PV
6 mm2 (#10 AWG)
NOTE: Larger cables must be used if battery cables exceed 3 m length
NOTE: Battery cables must be twisted together during installation
Battery Sense Required Size
0.33 to 0.08 mm2 (#22 to 28 AWG)
Terminal Torque Value
5.0 Nm (50 in-lb)
Grounding
Not required
External Protection (recommended)
Followall local codes to select overcurrent
protection.
Battery
≤ 40 Adc, ≥ 100 Vdc
PV ≤ 20 Adc, ≥ 100 Vdc
Environment
Operating Temperature
-40°C to 60°C (derated to 18A output from 50
to 60°C)
Humidity
0 to 95% RH non-condensing
Ingress Protection
IP20
Battery Bank
Minimum 100 Ah at C/5 discharge rate
Certifications
CE, EN 61000-6-1, EN 61000-6-3, IEC/EN 62109-1
Warranty
2 years
Popular Controllers manuals by other brands

dixell
dixell XR20C Installing and operating instructions

EIS
EIS New 100 Series User and installation manual

Storz
Storz OR1 SCB CONTROL installation instructions

Xylem
Xylem HYDROVAR HV 2.015 operating instructions

Bluebell
Bluebell BC780 Operation guide

fischertechnik
fischertechnik ROBOTICS TXT 4.0 operating manual