SAFETY DECLARATION
This appliance cannot be used by children or persons with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction.
With Potentiometer Type
Please refer to the table below to define the actuator's extension.
When Red (M+) is connected to "+" and Black (M-) is connected to "-"
of DC power the actuator will extend.
White, Yellow & Blue are positioning signal wires as shown in table.
The resistance between Blue and White wires increases when
extending, and decreases when retracting.
BW
YW
B
Y
Actuator retracting
Value of Potentiometer
Stroke(mm)
100
150
200
300
450
600
Resistance
Tolerance: 0.3 K
0.3-8.0 K
0.3-8.5 K
0.3-9.1 K
0.3-8.6 K
0.3-9.2 K
0.3-9.8 K
The Ohm value between blue and white wire
External Reed Sensors
Pick any wire of each sensor and connect them as common point, then define
the rest one as signal input.
How to change the position of reed sensor:
step 1. Loosen the screws.
step 2. Slide sensor to the correct position.
step 3. Tighten the screws and make sure the sensor is fixed.
common
point
signal
Wiring
Red
Black
M+
M-
White
Yellow
GND
VCC
Blue Data