Smartpond DP700UV User manual

1
Submersible Pond Pump with UV
700 Gallons Per Hour
MODEL/MODELO #DP700UV
PACKAGE CONTENTS
WARNINGS AND CAUTIONS
WARNING
•Risk of electrical shock. This pump is supplied with a grounding conductor and grounding–type
attachment plug. To reduce the risk of electric shock, be certain that it is connected to only a properly
grounded, grounding-type receptacle (GFCI).
•Do not exceed the voltage shown on the pump.
•Always disconnect pump from the power source before beginning any maintenance or work on the
pump.
•Inspect cord for damage before installation and/or maintenance. Replace the entire pump assembly if
damage is found.
•Do not remove the grounding pin from the power cord plug.
•To reduce the risk of electric shock, use only on portable, self-contained fountains no larger than 5 ft. in
any dimension.
•Risk of electrical shock: This pump has not been investigated for use in swimming pools or marine
areas.
CAUTION
•This pump has been evaluated for use with water only.
•Use a proper power source as indicated on the pump label.
•Keep the cord away from high temperatures or other heat sources.
•Avoid using the pump when water temperatures fall below 41° F.
•Do not use the pump in water exceeding 86° F.
•Do not pump heated liquids.
•Do not let the pump run dry. Pump must be completely submerged for proper operation and cooling.
•Operate in fresh water only. Avoid heavily chlorinated water and water with high pH levels.
•Do not lift the pump by its power cord.
Part Description Quantity
A Pump 1
B 3/4-in. adapter with flow control 1
Questions, problems, missing parts? Before returning
to your retailer, call our customer service department at
1-866-869-5300, 8 a.m.-6 p.m., EST, Monday-Friday, or
REMINDER
CALL 1-866-869-5300
BEFORE RETURNING TO STORE.
A
B

2
CAUTION
•UV light may cause irritation to the skin and/or eyes. Avoid exposure.
•DANGER – ULTRAVIOLET RADIATION – disconnect power before replacing lamp.
•Prolonged or repeated exposure to UV light may have adverse physical effects including, severe
damage to your skin and eyes. Seek immediate medical attention for overexposure to UV radiation.
•This light assembly has not been investigated for use in swimming pools or hot tubs.
PREPARATION
Before beginning assembly or operation of product, make sure all parts are present. Compare parts with
package contents list and diagram above. If any part is missing or damaged, do not attempt to assemble,
install or operate the product. Contact customer service for replacement parts.
•Estimated Assembly Time: 5 minutes
•Tools Required for Assembly: Philipshead screwdriver.
OPERATION INSTRUCTIONS
1. Connect the adapter to the pump by inserting into the pump
discharge and twisting clockwise. Then connect tubing to the
adapter. Fig. 1
Fig. 1
2. Place the pump into the water and connect to a proper power
source. Fig. 2
Fig. 2
MAINTENANCE PROCEDURE
In order to insure optimal operation of the UV pump, the following procedures should be performed
periodically. When the performance of the pump is reduced – it is an indication that cleaning of the unit
is needed.
1. Unplug pump, remove from pond. Fig. 3
Fig.3
GFCI
Pump
Tubing
Adapter

3
2. Remove the front screw, located on the bottom of the pump and
the rear screw located in the center of the rear filter screen. Fig. 4
Fig. 4
3. Remove the front filter screen by firmly pressing in front of the
discharge. Fig. 5
Fig. 5
4. Remove rear filter screen by gently pulling straight insuring that
the auto shut-off probes are undamaged when the rear screen is
removed. Fig. 6
Fig.6
Press
here
Auto
shut-off
probes

4
5. Remove filter pad from front filter screen. Clear debris from filter
pad by running under warm water. Fig. 7
Fig.7
6. Remove UV bulb assembly by gently pulling on cable connecting
the bulb to the pump. Be careful to pull assembly straight out so
as not to damage the UV assembly. Fig. 8
Fig. 8
7. Note: In the unlikely event the UV bulb needs replacing, remove
glass tube by pulling straight apart by holding the base of the
lamp. Gently pull bulb straight apart from the bulb socket and
insert the replacement bulb in the reverse manner careful not to
bend the wires at the stem of the bulb. Fig. 9
Fig. 9
8. Clean the exterior of the UV glass tube with warm soapy water.
Fig. 10
Fig. 10
9. Inspect the pump housing where the UV assembly resides and
remove the aluminum reflective shield. Clean with warm soapy
water. Fig. 11
Fig. 11
Bulb holder
UV bulb
Glass cover
Clean with soap
Filter pad
Front
cover
Reflector Lamp
holder

5
10. Clean the pump housing where the UV assembly resides insuring
that no debris remains. Fig. 12
Fig.12
11. Remove the impeller cover to expose the impeller assembly.
Remove the impeller assembly by gently pulling on the impeller
blades. Use a soft cloth or brush to clean the impeller assembly
and inside of the impeller housing. Fig. 13
Fig. 13
12. Reassemble all of the components. Fig. 14
Fig. 14
CARE AND MAINTENANCE
•Clean the pump regularly depending upon the environment in which it is operated. Clean the pump
when it is visibly soiled or when a drop in performance is detected.
•Before cleaning, always disconnect the pump from the power source.
•Remove all parts from the pump and clean in warm, soapy water.
TROUBLESHOOTING
If the pump fails to operate:
•Check to make sure the power cord is plugged in, the pump is getting power and the pump is
fully submerged.
•Check the pump outlet and any tubing, fountains, spitters etc. for kinks or obstructions.
•Remove the inlet screen and/or pump cover, and impeller housing to expose the impeller. Turn
the impeller to ensure that it is not broken or jammed.
If the performance of the pump is not satisfactory or the pump does not flow evenly:
•Check to make sure the pump is completely submerged in water.
•Check to make sure the impeller, filter pad and the housing are clean clear of debris.
•Check the pump outlet and any tubing, fountains, spitters etc. for kinks or obstructions.
•Adjust flow control.
Clean with soap
Impeller cover
Impeller
assembly

6
REPLACEMENT PARTS LIST
For replacement parts, call our customer service department
at 1-866-869-5300, 8 a.m.-6 p.m., EST, Monday-Friday.
PUMP PERFORMANCE
Flow Rates/Flujo (GPH)
12’ 184
11’ 76 229
10’ 108 262 100
9’ 123 292 200
8’ 157 333 290
7’ 61 180 375 350
6’ 96 196 401 400
5’ 124 216 439 450
4’ 151 254 476 502
3’ 166 260 504 550
2’ 198 288 525 590
1’ 217 330 566 635
Lift / Elevación ( feet )
0’ 237 337 593 715
DP210 DP330 DP560 DP700UV
Pond Pumps
Printed in China
Part Description
B Front cover
C Filter pad
D Rear cover
E 3/4-in. adapter with flow
control
F Screw
G Reflector
H Glass tube
I UV bulb
J Lamp holder
K O-ring
L Impeller cover
M Shaft support
N Washer
O Impeller assembly
P Shaft
D
E
J
H
I
M
N
P
O
B
C
K
G
F
N
M
L
F

LIMITED WARRANTY
All pumps and electrical products are warranted to the user against defective material and workmanship, under normal
working conditions. This warranty period begins on the date of purchase by the original purchaser.
Item Limited
Warranty
FP45, FP80, FP155, FP500, FP170AS, FP300ASL 1 year
DP210, DP330, DP560 1 year
WP2000, WP3600 1 year
LDS10W, LDS10W3, LVSL, FTNFG 1 year
PCUV9 (excludes UV bulb) 1 year
PL0710, PL1013, PL1320 lifetime
ACFK and MFBX500P (pump only) 1 year
PBF1200UV (UV filter only) 1 year
WGK200 (pump only) 1 year
DP700UV, WP1300UV 1 year
DPKIS (pump only) 1 year
EPDM1520, EPDM1525. EPDM2020 20 years
APH 3 years
Application
Warranty covers only properly installed and maintained units. Pump warranty is limited to applications pumping fresh water
at temperatures between 41°F ―86°F, with a pH range of 5 ―9. Other liquid applications or extreme temperature uses
must be approved in writing by the manufacturer. Receipt and product date code are required for warranty claims.
Warranty Claim
Warranty claims must be made by calling customer service (at 1-866-869-5300). If the item is determined to be
defective, you will be given authorization to return the defective part(s), freight pre-paid, along with proof of purchase to:
GeoGlobal Partners
1719 Old Okeechobee Road
West Palm Beach, FL 33409
Attn: Customer Service
Disposition
The manufacturer will make a good faith effort for prompt disposition regarding all warranty claims. Returned product will be
inspected to determine cause of failure before warranty is applied. Warranty does not cover any costs associated with the
shipping, handling, installation or removal of products or parts subject to this warranty. For products damaged in transit, a
claim should be filed with the carrier.
Disclaimer
Any oral statements made about the product by the seller, the manufacturer, the representatives, or any other parties do not
constitute warranties, should not be relied upon by the user, and are not part of the contract for sale. The seller’s and
manufacturer’s only obligation, and buyer’s only remedy shall be for the manufacturer to either replace and/or repair at the
manufacturer’s sole discretion, the product as described above. Neither seller nor the manufacturer shall be liable for injury,
loss or damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss arising
from any cause whatsoever, no matter whether based upon warranty, contract, negligence or other misuse, and the buyer
and user agree that no other remedy shall be available to them. Before using, the buyer and user shall determine the
suitability of the product for the intended use, and assume all risk and liability whatsoever in connection therewith. The
warranty and remedy described in this limited warranty is an exclusive warranty and remedy in lieu of any other warranty or
remedy expressed or implied. All other warranties and remedies are hereby expressly excluded, including but not limited to
any implied warranty of merchantability of fitness for any particular purpose. This warranty gives the buyer and user specific
legal rights, and buyer and user may also have other rights which vary from state to state. Some states do not allow
exclusions or limitations of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
REMINDER
CALL 1-866-869-5300
BEFORE RETURNING TO STORE.
Other manuals for DP700UV
1
Table of contents
Other Smartpond Water Pump manuals

Smartpond
Smartpond 52672 User manual

Smartpond
Smartpond PWP2000 User manual

Smartpond
Smartpond 80 GPH User manual

Smartpond
Smartpond WPR2000 User manual

Smartpond
Smartpond DP700UV User manual

Smartpond
Smartpond 84575 User manual

Smartpond
Smartpond 170 GPH User manual

Smartpond
Smartpond DP700UVCA User manual

Smartpond
Smartpond 84572 User manual
Popular Water Pump manuals by other brands

Cipax
Cipax CPX Installation and user instructions

Grundfos
Grundfos JP5 Installation and operating instructions

Lincoln
Lincoln 4100 user manual

Vogelsang
Vogelsang VX100Q operating instructions

Sykes AmeriPumps
Sykes AmeriPumps GP100 Operation and maintenance instructions

All-Flo
All-Flo A100 Operation & maintenance manual