Smoke Guard 200 User manual

Codes and Standards. The M200/M400 systems work in
conjunction with fire-rated elevator doors to exceed the NFPA
and IBC requirements for a smoke and draft control assembly.
This enables the elevator to open directly onto the corridor.
Dimensions
• Housing lengths: 55” and 64”
• Housing height: 10.5”
• Housing depth: 10”
• Return depth: 1”
Standards
• UL 1784 “Air Leakage Tests of Door Assemblies”
listed by Intertek
• UL 864 “Control Units for Fire Protective Signaling Systems”
listed by Intertek
Code References
• 2003 IBC Section 707.14.1
• 2006 IBC Section 707.14.1
• 2009 IBC Section 708.14.1
• 2012 IBC Section 713.14.1
• 2015 IBC Section 3006.1
• NFPA 105 “Installation of Smoke Control
Door Assemblies”
800.574.7474
I
smokeguard.com
SGSO-1 • Rev. 2 • COPYRIGHT 2020 SMOKE GUARD,
System Description. The Smoke Guard system
Models 200/400 (M200/M400) create a code
compliant smoke- and draft-control assembly
when paired with common fire-rated elevator
doors. The Smoke Guard DuraNet™ screen
assembly consists of a reinforced transparent
material connected to flexible magnetic strips.
These magnets adhere to either required
full-length ferrous metal rails (M200) or the
existing ferrous elevator door frame (M400) as
the system deploys creating a tight seal. M200/
M400 units use standard 120 VAC building
power and may be connected to standby power.
Elevator Smoke Curtain
Models 200/400
System housing
Fire-rated
elevator door
Ferrous metal
elevator rails
US PATENTED
120V AC Line in
(by others)
Smoke Detector
(by others)
Housing
Kevlar®
Cables
Flexible
Magnetic
Edge
DuraNet™
Screen
Assembly
Auxiliary Rail
Auxiliary Rail
Backer
Screen
Rewind Switch
(both sides of curtain)
Fail Safe Secure.
M200/M400
systems operate on a fail safe
basis, on loss of AC power the screen will deploy. There is a
deployment delay on power failure built into the system to
avoid nuisance deploys on brief power outage.
Battery Backup.
M400 units may be specified with an internal
battery backup. This feature is not available in M200 units.
Listed Releasing Device. The
M200/M400
features a
releasing device tested in accordance with the UL 864
standard by Intertek Laboratories.
Rewind Switch. The Smoke Guard system screen rewind
switch may be activated from both sides of the screen.
This feature allows elevator occupants to exit from the
elevator car using the interior (shaft side) of the switch. The
screen will then redeploy after egress, as long as the smoke
detector continues to be activated, providing continued
smoke protection for the elevator hoistway. In the event of
power outage, the vertical edge of the curtain can be pushed
away from the rail to allow passage with a force less than
15 lbs. as referenced by the ICC.
800.574.7474
I
smokeguard.com
SGSO-1 • Rev. 2 • COPYRIGHT 2020 SMOKE GUARD, INC.
System Operation.
Smoke Guard elevator systems
are designed to protect elevator openings and
shaft from vertical smoke migration. The system
will deploy when the smoke detector in the
elevator lobby goes into alarm (or on loss of power
to the unit). The system is not designed to deploy
on general alarm. As the lobby smoke detector
goes into alarm, the elevator will automatically
return to the recall floor. If an elevator occupant
were to encounter a deployed M200/M400, a
screen rewind switch located on both sides of the
screen will allow for egress. If smoke is still actively
being detected, the screen will then redeploy to
seal the opening. As power is restored, the screen
will automatically rewind into the housing.
Installation. All Smoke Guard units are installed
by factory trained and certified personnel. There
is minimal preparation work. Installation requires
a clear, plumb, unobstructed wall surface above
the hoistway door, 120v AC power and a smoke
detector.
Elevator Smoke Curtain
Models 200/400
Check for clearance/obstructions issues
on, above, and surrounding the elevator
opening (sprinklers, call buttons, HVAC, etc.)
Field verify elevator opening measurements
prior to ordering systems
Available 120 VAC circuit with 2 amp
capacity per unit
Fire alarm system has local auxiliary
contacts available
No auxiliary rails: elevator door frame
is ferromagnetic
Smoke Guard and Your Project

Other manuals for 200

2

This manual suits for next models

1

Other Smoke Guard Firefighting Equipment manuals

Smoke Guard 2100 Manual

Smoke Guard

Smoke Guard 2100 Manual

Smoke Guard 200 User manual

Smoke Guard

Smoke Guard 200 User manual

Smoke Guard 4000 User manual

Smoke Guard

Smoke Guard 4000 User manual

Smoke Guard M2500 Smoke User manual

Smoke Guard

Smoke Guard M2500 Smoke User manual

Popular Firefighting Equipment manuals by other brands

Tyco Fire Protection Products AM31 AQUAMIST Nozzle instructions

Tyco Fire Protection Products

Tyco Fire Protection Products AM31 AQUAMIST Nozzle instructions

Task Force Tips Extend-A-Gun RC3 INSTRUCTION FOR SAFE INSTALLATION, OPERATION, AND MAINTENANCE

Task Force Tips

Task Force Tips Extend-A-Gun RC3 INSTRUCTION FOR SAFE INSTALLATION, OPERATION, AND MAINTENANCE

Ansul INERGEN Installation and maintenance manual

Ansul

Ansul INERGEN Installation and maintenance manual

Amerex B270 Owner's service manual

Amerex

Amerex B270 Owner's service manual

TFT Working Fire Instructions for installation, safe operation and maintenance

TFT

TFT Working Fire Instructions for installation, safe operation and maintenance

QTAC 85 EMS-C owner's manual

QTAC

QTAC 85 EMS-C owner's manual

Bosch FPC-500-2 Quick installation guide

Bosch

Bosch FPC-500-2 Quick installation guide

Kidde Fire Systems FM-200 ECS Series Design, Installation, Operation, and Maintenance Manual

Kidde Fire Systems

Kidde Fire Systems FM-200 ECS Series Design, Installation, Operation, and Maintenance Manual

Task Force Tips Twister Series Instruction for operation and maintenance

Task Force Tips

Task Force Tips Twister Series Instruction for operation and maintenance

Siemens DMS8000 Operation manual

Siemens

Siemens DMS8000 Operation manual

Tyco K17-231 quick guide

Tyco

Tyco K17-231 quick guide

Amerex B571 Owner's service manual

Amerex

Amerex B571 Owner's service manual

TFT ULTIMATIC Instructions for installation, operation and maintenance

TFT

TFT ULTIMATIC Instructions for installation, operation and maintenance

Task Force Tips Masterstream 4000 ER Automatic INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE

Task Force Tips

Task Force Tips Masterstream 4000 ER Automatic INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE

ENFORCER 30 Operation and maintenance manual

ENFORCER

ENFORCER 30 Operation and maintenance manual

Plumis Automist Smartscan Hydra Design, Installation, Operation and Maintenance (DIOM) Manual

Plumis

Plumis Automist Smartscan Hydra Design, Installation, Operation and Maintenance (DIOM) Manual

Waterax MARK-3 owner's manual

Waterax

Waterax MARK-3 owner's manual

Dräger Handy Pak operating manual

Dräger

Dräger Handy Pak operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.