Soca ST-320 Specification sheet

wf sT-320
WATER.PROOFPROXIM
ITYAGCESS
CONTROLSYSTEM
OPERATIONAND
INSTALLATION
MANUAL
SOCATECHNOLOGY
CO..LTD.
2000November

CONTENTS
l. SPECIAL
FEATURES...
.............. ...............1
ll. FRONT
PANELANDTYPESOF
cARDs.................................t
ilt |NSTALLATIONPROCEDURES..... .........,....3
IV.SETTINGMODEAND
FUNCTIONS. ,............4
'|.
Registrationofcard
(Add
onecard).................................
.4
2.Deletionand
lossofcard
(Delete
one
card)......................'.5
3.
ChangeofI setsofuser's
passwords...,....,........
............
s
4.Doorlocktimesetting
(shunt
time) .. .. ............
6
5.Seftingidentification
modes.............................................
6
6.
Batchregistration
(add
series
cards).......................-....
...
7
7.Anti-tamper
outputsettin9...............................................
7
8.Changingsystem
password(command)............................
I
9.Deletionof8sets
ofuser's
passwords
........................,....
8
I0.Deletionof batchregistration
(Delete
allcards)........... .'.'.
I
ll.Door opening
(using
system
password).....
12.The
DuressCodeSetting............ . ............
......9
v |NSTALLATIONOFPROXIMITYREADER
. . .................-.......10
1,
Connections..... ................,..
'10
2.Installationof electric
lockand
exitpGh butbi................ 11
3.fnstallationof doorsensor,extemal
relayandsir€n...
" """'12
vr. PRECAUT|ONS........................ ................
l3
vil. TROUBLESHOOTING................. ..............
14

ST-32O Mode Setting
I.SPECIAL FEATURES:
l. Oneset stand alone design.
2.After installation of Proximity readerand is connected to power
source, red power indicator on the front panelwill light up.
3.4 typ€ of door opening modes:
(1) Enter4digit door opening password, identification code is l'
(2)Proximity card door access, identification code is 2.
(3) Proximity card plus 4-digit door opening password ( 8
sets of 4{igit door opening passwords), identification code is 3'
(4)Proximity card or 4digit door oPening Password,
identification code is 4.
4.\whenentering into the system setting mode' 4-digit system
passwotd should be entered in order to enter into system setting
modes.
System code is being set at 45€Zon production' Inorder to enter
into the system lo set up mode, press jlE fiFt then enterigggwg4l
and presslEagainwhen completed.(Example: +# 4 5 6 7 # ).
5.All proximity card or proximity key tag must be registercd before
use.
6. Prcximity card or proximity keytag has Sdigit number Gode'
The
card number rcquired for setting is the last 6 digits.
7. 8 sets of door opening passwords.
8.Maximum storage capacity of 2,000
cards.
9, Datamemory feature in case of power fuilure'
II. FRONT PANEL AND TYPES OF PROXIMITY CARD:
FRONT PANEL
1.Indicator
lights:
(1)
KEY
light(green)
(2)
Status
light(green)
2.Barindi€tor light:
: Greenflashing
lightonwhen
buttons pressed.
: Green
light
onwhen
entering.
(1)
OKlight(gen barindi€tor light):
Dooropenindicator
light.
(2) Porer light (Ed bar indiEtor light): Systemstandby.
3.Ten enter keys,two functional keys: "#", " * ".
# key; confimation key.

* key: Clearor escape key
Statuslight
(Green
)
Presskey light
Powerllght
(Red)
OKllght(Green)
Denylight
(yellow
flashing
light)
Alam(yellow
light
on)
Confirmation
key
Clearol
Key
Types of proxlmltt/ cards
Thefollowing
3typesofcardsareEquiredto registerbeforeuse
SC-i0 : Thin card , thickness 0.8 mm,
ISOstandard card dimension.
Readrange '10
cm. lt can be printed
directly from card printef,
SC-20: Thick card , thicknoss 1.8mm,
ISOstandard card dimension.
Readrange 10cm. lt can be printed
directly frcm card printer.
SC-30; Keytag, read Enge ftm.
dimension 5.5LX 7.5HX 3.2W(mm).
Ultrasonic connection, wate?-proof,
shock- proof.
[t
tl
tl
[f
tEl
t@1
l-l
r@r
ID

III.INSTALLATION
PROCEDURES
F*ffi;l
trtherc bn't anyadv.ton Sthin
20s@nd6, thi3system
Sll
aubmalically
66pe tom the
3ding mode
U$E muldinsblleiler&Pin or
&Din conndor b *€ ffr Pleaser€fel
11-12
Check
iftheporer (RED)indhatd
lighb uP
! ves
Enler syftn p$ssd ( *ffi?#), then a hep
soundand
gr€en
llght
appearto
enleriflo
setlng mode +
Enter1 (register the proilmity card) or 5
(btuh qistraton) Then,
qisteralllhe
ds prcnmity 6ds and keY
bgs when
mpHed, F* + to €€F ftom lhe
dq||* +

IV. SETTING MoDES AND FUNCTIoNS :
To enter into the system setting mode, fiBt press* #, then enter
system password and press #subsequently to enter into system
sefting mode. When entered into system setting mode, the
STATUSlight(green
)on thepanel
will beonwith abeepsound.
Usereshouldenter
any
functional
selections
within20seconds.
The readerwill automatically terminate the system setting mode
function after 20seconds.
I Add one card : To register user's card and utilize proximity
to register
SUCCESSFULLY
fiEPc^r EGanAru)
+ F-.ss--l
* lT,^Fl REGISTRATION
Ontheabove
operation,if " * " is being
pressed,
thecard
registration activities will beterminated.

2. Delete card : Deletion of user's card (such as loss ofcard), card
number is the 6-digit code indicated on the proximity card.
G*;l f:r.lLs"rlc-1*ill
fpRE,;l t-TEEp-l
[:ru;l[.,
"-,
I
*tLii-{'"___J
*Lj-J *Lifrii-J
*
On the above opemtion if " * " is being pressed, the setting
modes will beteminated, provided that there isn't any key
being entered.Any key-in being done prior to this operation
will be deleied.
3. Chrnge of8 xts of user's pasword:
+[**l -F**] SUCCESSFULLY
*[u::l,T'l- [.tffi*-lr I
lelgl
-
-lEEEl

4. Door lmk tine setting : This setting is to detemine its unlock
time. Time can be set from 0'l-99seconds.
5. setting identification modes:
Thereare 4 sets of door-opening mod6. UseF could only set one of
the identification modes for access control. lts identification mode
has been preset to prcximity Garddoor-opening.
(1)Door opening based on 4digit Password (Thercarc atotal of I
sets of use/s password), mode number is 1.
(2) Proximity card door opening, that is door will open when the
card is sensed. mode number is 2.
(3)Proximity card and enter 4digit password door opening,
mode number is 3.
(4)Proximity card or enter 4digit password door opening, mode
number is 4.

6. Batch registration : To be used for registering multiple cards and
cards in series. Enter6-digit card number,then enter amount of cards,
in 4-digit
manner
(must
beinfull4 digits,such as 100
pca.
,enter0100).
This system can also apply to single card entry.
'-' r':l
| '*# " SYSTEM
| -l STATUSL|GHTON
[:AsswoRpjJ+[
w,il;;#ibilipl+ I
enessol
* |135i1
l-
' l______J
7. Anti-tamper output setting : This readerhas an anti-tamper
output connecting point, There aretwo detection sources:
(l) Damageto the proximity rcader(tamperswitch).
(2)Damageto the door (must add detection wiring such as
rced switch).
This function en be set wtEtlEr d@l detecdon point is
applied to activate the anti-tamper ouQut:
(1)
O: ON
(2) | :OFF
I enren 1 /-;J
l "r.*"svsreu
l
*l "lli'^'3H?T"iX,
l*G;| *fp=ry-l
*
I PASSWORD
"f"l | ) [ souNp I
- [*'**l
* ['*"*l

8. Change system password : To change system password, this
reader's password is being preset at 4567. Please
note that this password is necessaryto enter into the system
setting mode.
System password has been preset at 4567. Use6 should enter
new4-digit system password twice to complete change of
system password.
Deletion of 8 setsof user's password : Pleasenote that this
function will deleteall the 8set of use/s passwords and cannot
be retrieved.

10. Delete all cards : Pleasenole that this function will deleteall
registercd card and cannot be rctrieved.
11. Door opening (using system password) :
t--
r'lpness0l + | opENDooR| + IcoMPLETEq
12. The duress code setting:
lpnessravel+lrEnnq

V. INSTALLATIONOFPROXIMITYREADER:
1.Readerconnections
:
ST-320Wiringdiagram
Red
Black
Brown
8-PlN Orange
CoNNECTOR Yeilow
Green
Blue
Purple
Red
BJown
6-PlN creen
coNNECTOR Btue
Purple
Yellow
2-PIN
CONNECTOR
Anti-Tamper switch, common contact
Anti-Tamper switch, nom.lly open conlact
Roseffed
Anti-Damage alarm output
Anti-Duress alarm oulput
Door detection *nsor point 1
Door detection sensor point 2
GND
DC
+l2V
GND
Door control relay.Dry contact ( N.O. )
control relay.Drycontact ( N. C )
cont.ol relay.Dry contact ( COM.)
push button
Blue
BlueI mm*l""l
* DooroponrelaycontactEtingtrclArr 3A
:* TamperswitchcontactEtingDCI2V/ 0.lA
t( Doorbell switchcontact
rating
Acl25V
/3A

2. Installation of electric lock and exit push button:
A. Electric lock(fail securetype)and reader.
E|.ffi
roFr
*u!
6 Din
' oEt
Brcm
@
B. Electric lock (fail safe tlpe) and reader .
Note: (l)fail-securc type lock : Connect to 6-pin connector, blue
and
greenpoints.
(2)failsfe typ€ lock : ConHt to 6fin conretor, pulple
atd gr€en poinE.
(3lerit Frlh bub.r c.n odt be |l.cd by drt- qtacf
€ *,r"r"" ELE;r5rgLgcK
- | eunor t fKKl r

3.lnstallation of door sensor, external relayand siren :
A.Installation
ofreed
switch
(normal
close),external
relay(anti-damage)
fFgirEES;
EE'
gfe
B Installation ofre€d switch (normal open),cxt€rnal relay(anti-duress)
6-Pin 8-Pin
Note : (1)Proximity readerprovides two external relayconnecting
points which are :
A. Anti-damage ( tamper switch and door sensor ) alarm
output connecting point ( 8P orange connecting poini ).
B. Duress alam output connecting point ( 8p yellow
connecting
point).

(2) lf door sensor detecting (such as reedswitch) points are
applied, please set ALARMto ONmode.
For setting method, please referto setting mode functional
selection item 7 in the manual.
3. For installation, please tink power supply wire and control wire
through the base panelfiret and then fix the base panel onto the
wall.
4. Install the proximity readeron the base panel (power supply wire
and control wire must first be inserted and the wircs must be
arranged corectly), and then usethe enclosed keywrench and
screws to mount it up.
5.Powersupply: DC12V500-800mA.
6. Powerconsumption, standby 90mA,active I lOmA.
7.Dimensions:
125mm(L)
X 33mm
(W)
X TOmm
(H).
* DONOTSHARETHESAMEPOWER
SUPPLY
OF BOTH
ELECTRIC
LOCKAND PROXIMITY
READER
TOGETHER. USERS
SHOULDPROVIDE
SEPARATE
POWER
SUPPLY
FORBOTHOF
THEM.
Vl.
pnnclutrons:
1.Before installation, pleasecheck the voltage and polarity of the
power supply in order to avoid wong connection causing damage
to the cader.
2. Pleasedo not share the power supply together with the electric lock
and the proximity reader .
3. Pleasedo not install metal product or monitor nearthis equipment
in order to avoid distance proximity.
4 Please
do notconduct
anyrepairment
oranymodification
to the
system,
unlessbyqualifiedp€Fonnel
5- W.rr.rtt period for t'|. reader b I year.

VII. TROUBLESHOOTING
1.Card sensed but the door lock doesn't work.
Solution: (1) Please
check if the power supply is on the
proximity readerand the electric lock-
(2) lf (1)is chaked, please check the electric lock power
supply and whether the connecting points are correct.
(3)Continuous proximity. Pleaseremovethe card from
the readerand try again.
(4)Pleasecheck whether the door opening mode is
correct.
3. System password is entercd but cannot enter into various
functional selection of the setting mode.
Solution : Incomplete input of system password, please check
whether the following format has beenentered:
*#XXXX# (XXXX
representssystem password), or firet
press "*" then entervalid system password +#XXXX#
4. How to use the duress code setting?
Solution : (1
) Users should change door opening mode to 4-digit
password
dooropening(mode
codel), or proximity
card
or4digit password
dooropening(modecode
4)in order
to enable duress code setting.
(2)Afterthe door opening mode is set (pleasereferto
item 5 of the setting mode functional selection on how
to set door opening mode), press " * # The Duress code +
4digits dooropening
password
#",then
theduress
alarmoutput
functionwill execute.
5. How to temimte antidamage actiEtkn q dutaa &m tctivity?
Solution : Enter into systsm setdng modo or oDdr fu dc.
6.What is the operation of the door sensor detection (red switch)?
Solution : lf the door sensor detection function is being set at ON
(for detail, referto item 7 of the sefting mode functional
selection in the manual)and if the door is not closed
within 30seconds, then the anti-damage output function
will beactivated.
l5

Appendix
Mounting
of reader
unit:
SlEPl: U$ screwdriver to
dismantle or open the
covere of screws at
the top and bottom of
the |eader unit.
Useenclosed sp€cial L-
shape spanner to unscrew
and rcmove the special
screrc anti{lockwise
(direction). Pleasemake
sure all four O{ings arc
fitted io tlF scrcws, when
r€moved.
SepaEte front cover
fm the bale ryer.

Screwwater proof pad
with base cover tightly
onto the wall.
Link connectors
thrcugh water proof
pad and base cover to
connect to the reader
unit.
ScH tlp front cover
witr base @Yer tightly
with four screws (make
sure all four o-rings are
fitted to the screws!

Press the screre
covec( top and bottom)
fimly.
ATTENTION:
(when mounting onto rough wall)
Useappropriate size of flat acrylic or wood piece (Do
not use metal piece)to mount onto rough wall
with silicon glue. Screw or fit the basecover onto it.
Other manuals for ST-320
1
Table of contents
Popular Control Unit manuals by other brands

Telit Wireless Solutions
Telit Wireless Solutions LE915A P Series HW User Guide

PFS
PFS Connect installation instructions

Belimo
Belimo Z2050QS-J manual

BENDIX
BENDIX QR-N QUICK RELEASE VALVE manual

PSA
PSA HA-GM Installation, operation and maintenance instructions

Homematic IP
Homematic IP 153413A0 Mounting instruction and operating manual

Siemens
Siemens IM 155-6 PN ST Equipment manual

Emerson
Emerson CROSBY INSTALLATION, MAINTENANCE AND ADJUSTMENT INSTRUCTIONS

hpmont
hpmont HC10 Series user manual

ActronAir
ActronAir CL01-2W Operation manual

SIBER
SIBER WIRELESS MULTICONTROL v.8 installation manual

SCHUCK
SCHUCK U Installation & operation manual