SODECA UPM/EC User manual

Code: 1276550
Doc. Num: 0000021532 (11/06/2020)
www.sodeca.com
UPM/EC
ES
Manual del Usuario
User manual
EN

Fig. 1
Fig. 2
Fig. 3
Rotate the tabs and
remove the filter

Fig. 4
Fig. 5
Fig. 6
Fig. 7

Fig. 8
Fig. 9 - Technical Characteristics
Model
Advisable working
Surface
¹
(m²) Speed Fan
Power Power supply
Sound Level
²
Max. Airflow (m³/h) Weight
Filtros
(F7+F9)
Filtros
(F7+H14) (r/min) (W) dB(A) Filtros
(F7+F9)
Filtros
(F7+H14) (kg)
UPM/EC-310 140 50 1920 175 200-240V 50/60Hz
1Ph 29 1450 510 55
UPM/EC-400 220 130 1550 460 200-240V 50/60Hz
1Ph 38 2200 1300 97
UPM/EC-500 300 325 1250 1150 380-480V 50/60Hz
3Ph 36 2990 3250 165
¹
Recommended surface with 3 meters high local
²
The values of the Radiated Noise Level, are in dB(A), measured at 1,5 meter, and at maximum flow rate (Qmax).
Fig. 10 - Filter Characteristics
Fig. 11 - UVc Germicidal Technical Characteristics
Filters
EN779 Em EN 1822 ISO 16890
ISO ePM
1
ISO ePM
2,5
ISO ePM
10
ISO COARCE
G4
90%
- - - -
>90%
F7
90%
-
>50%
>65-95%
>85%
-
F9
95%
-
>80%
>95%
>95%
-
HEPA H14
-
>99,995%
-
-
-
-
Model Number of
lamps
Total electrical
power (W)
Total radiation
power UVc (W)
Radiation doses
(mJ/cm²)
UPM/EC-310 6 66 16,8 5,9
UPM/EC-400 4 100 28 5,6
UPM/EC-500 6 150 42 4,5

EN
1. Start
All fans produced by SODECA, hereinafter the manufacturer, and the full line of accessories, have been manufactured in
accordance with the strictest standards in relation to quality assurance, systems and production processes.
Their project, testing, manufacture and control structure has been configured in line with EU standards and regulations,
especially in reference to current safety standards.
The materials used in our fans, and the standardised components of which they are made meet the same standards and,
when so required, are backed up by the corresponding quality certificates.
The Original Manual was written in Spanish.
The manufacturer reserves the right to make modifications without prior notice.
All the documentation in this manual is the property of the manufacturer, and its total or partial reproduction is prohibited.
2. Product Definition
UPM/EC: Mobile air purifying units, designed for cleaning and purifying indoor air and eliminating odours in any type of
room.
IMPORTANT: This product is not suitable for use in explosive environments or for fire safety.
3. General Information
• Always check the products received.
• After unpacking the equipment, it must be checked to make sure that it is not damaged. Damaged products must
never be installed.
• This equipment must not be used for purposes other than those for which it was designed; it must only operate
under the conditions described in this manual.
• In the event of a defect or malfunction, this must be reported to the authorised representative, with a description of
the problem, in order to coordinate its return or possible repair.
• Before starting up the equipment, it is important to ensure that the safety and installation instructions in this
document have been read
4. Transportation, storage and handling
• Always hold the equipment at the points provided for this. Do not lift it by the electrical cables, connection boxes,
or the air inlets or outlets.
• Before installation, store the equipment in a clean, dry place, protected from inclement weather.
5. Safety
• CAUTION! Electrical power must be removed from the unit prior to opening the inspection covers to access the
UVc lamps if installed; otherwise, these lamps could cause damage to the eyes and skin.
• If a UVc lamp breaks, ventilate the compartment for 30 minutes and remove the lamp pieces, preferably while
wearing protective gloves.
• Do not disassemble or modify the equipment. This could negatively affect the equipment or even cause accidents.
• Do not put your fingers or any objects into the protective grilles on ducts, inlets or outlets. If this were to occur,
immediately disconnect the equipment's power supply.
• Never use a damaged power cable.
• Do not perform equipment inspection or maintenance without first checking the following:
o That the equipment has been disconnected from the electrical supply.
o That all its components are at rest.
• The equipment must not be operated unless it has been properly installed and the inlets and outlets have been
protected.
In designing and manufacturing the various Series of the manufacturer's Fans and Extractors, Hazard Elimination has been
taken into account, in order to meet the conditions for Integrated Safety.
When their configuration and manufacturing processes permit this, the manufacturer directly incorporates the most
appropriate Safety Devices. If the conditions for installation or use mean that these devices cannot be incorporated at
source, all additional safety accessories are available for implementation when the equipment is installed and before it is
put into service.
This manual suits for next models
3
Table of contents
Other SODECA Air Cleaner manuals