1. Introduction
Congratulations on buying your new measurement instrument. You are now
the owner of a precision measuring device with a finely adjusted laser. In
developing our products, our goals are to simplify the measuring process,
improve results and save time.
Please read this operating manual attentively before you use the device. Never
obliterate, or remove, the warning signs on the measuring tool. Keep these
instructions somewhere safe.
2. Contents
3. Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4. Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5. Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7. Checking and adjusting the FCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
8. Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
9. Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
10. Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
13
GB
SOLA Inhalt FCL.qxd:inlet_FCL 08.04.2008 14:04 Uhr Seite 13

3. Description
The numbering of the device elements refers to the display of the device on
the graphics page.
On/Off switch
Adjustment wheels
Vial
Laser beam output
Battery cover
4. Safety instructions
Before using the device, please read the operating manual and
safety instructions in full, and apply them carefully in practice.
Laser radiation/laser class 2/ (
≤
1.0 mW, 635 nm)
according to EN 60825-1
Do not look into the laser beam.
Do protect the measuring device from moisture.
Do not drop the measuring instrument.
The owner must inform the user as to the operational hazards of the equip-
ment and any protective measures required. The device may only be used after
the user has read and understood the operating and safety instructions.
14
GB
SOLA Inhalt FCL.qxd:inlet_FCL 08.04.2008 14:04 Uhr Seite 14

Improper use
• Using the product without having received instructions.
• Using the product for purposes other than those for which it is intended.
• Disabling safety equipment and removing instruction and warning signs.
• Opening any part of the device, except for the battery compartment.
• Modifying or making alterations to the product.
• Using accessories from other manufacturers which have not been expressly
approved by the manufacturer.
• Conscious or negligent handling of the device when measuring in the vicinity
of machines in operation or open machine parts or plants.
• Aiming the device at other persons, even in the dark.
• Exposing the device to extreme temperatures and temperature fluctuations
(e.g. do not leave it in the car).
• It is recommended that batteries be removed during extended periods of
product non use. (risk of self-discharge and corrosion).
15
GB
SOLA Inhalt FCL.qxd:inlet_FCL 08.04.2008 14:04 Uhr Seite 15

5. Technical data
Laser class:
2, according to EN 60825-1
Laser type: ≤
1.0 mW, 635 nm
Max. measuring tolerance:
0.3 mm/m
Operating range:
(approx) r = 10 m, depending on the light
conditions at the workplace
Laser diodes:
4 x 635 nm semiconductor diodes
Crossing angle:
90°
Weight:
Instrument: 650 g
Transport protection bag:
730 g
Power supply:
4x 1.5 V AA batteries
Operating time (approx):
16 hours all diodes
(continuous operation at 20°)
Operating temperature:
-10° C to +50° C
Storage temperature:
-20° C to +60° C
Modifications reserved.
16
GB
SOLA Inhalt FCL.qxd:inlet_FCL 08.04.2008 14:04 Uhr Seite 16

6. Operation
Inserting the batteries
First you must remove the battery cover from underneath the laser. When the
battery cover has been removed, you have access to the battery housing.
4 AA batteries are used for the FCL. Alkaline batteries are recommended for
optimum operating time.
Operation
• Switch on the laser by pressing the On and Off button.
• Press the button once: for 2 laser beams.
• Press the button twice: for 4 laser beams.
7. Checking and adjusting the FCL
Checking the accuracy of the laser
For this inspection, you need at least 1.5 m2floor space and someone to help.
Place the instrument on a flat and even floor and switch all beams on.
Measure exactly 91 cm along the vertical line of the laser crossing,
beginning at the centre point of the laser crossing. Then mark this point
A(fig. 6).
Measure exactly 1.22 m along the 90° reference of the laser crossing,
starting at the centre point of the instrument and mark this point B.
Measure the distance from point Ato B. This distance should be 1.52 m.
17
GB
SOLA Inhalt FCL.qxd:inlet_FCL 08.04.2008 14:04 Uhr Seite 17

8. Guarantee
The manufacturer guarantees the original buyer, as named on the guarantee
card, that the product shall remain free of manufacturing defects for a period
of two years after purchase.
This guarantee is limited to repair and/or replacement, according to the
manufacturer’s choice. This guarantee does not cover defects arising from
improper use of the device by the buyer or third parties, the natural effects of
ageing, or optical defects not affecting the operation of the device.
Claims under this guarantee are valid only when the device is returned
together with the original, fully completed guarantee card, date stamped by
the original seller.
In the case of a claim under the guarantee, the manufacturer will refund the
reasonable cost of return delivery. The guarantee period is not subject to
further extension (beyond the two years from original purchase date),
following repair or the fitting or replacement parts carried out within the
scope of the guarantee.
This guarantee does not affect your statutory rights.
9. Cleaning
Always keep the device clean and dry. Wipe off any dirt with a soft damp cloth.
Do not use any caustic cleaning agent or solvent. Use cotton swabs to clean
laser output regularly and remove any lint. Please bear in mind that the
laser is water-resistant but not waterproof.
This device is not designed for outdoor use therfore, if used outdoors, it must
be protected from rain and direct exposure to water. Failure to observe this
can result in damage to the device. Check the device each time before using
it. If there is any visible damage or if there are loose parts inside the device,
safe operation is no longer ensured.
18
GB
SOLA Inhalt FCL.qxd:inlet_FCL 08.04.2008 14:04 Uhr Seite 18

10. Disposal
Measuring tools, accessories and packaging should be disposed of in an envi-
ronmentally sound manner, i.e. recycled.
Only for countries of the EU
Do not dispose of the laser device, along with your household waste!
According to the European Directive 2002/96/EC all unwanted electrical and
electronic devices must be collected separately for specialist disposal.
19
GB
SOLA Inhalt FCL.qxd:inlet_FCL 08.04.2008 14:04 Uhr Seite 19
Table of contents
Other Sola Measuring Instrument manuals

Sola
Sola METRON 60 BT User manual

Sola
Sola Go! SMART User manual

Sola
Sola VECTOR 40 User manual

Sola
Sola QUBO User manual

Sola
Sola METRON 80 BTC User manual

Sola
Sola METRON 30 BT User manual

Sola
Sola CROSSLINE GREEN User manual

Sola
Sola VECTOR 40 User manual

Sola
Sola PROTON Series User manual

Sola
Sola HORIZON GREEN BASIC User manual