Please note:
1. the output will cut off once there is over load or short circuit. Press the power switch, the
controller will resume to work after 30 seconds.
2. After over discharged, the controller will resume to work when the battery is charged to 13.1V.
(for 12V system only, for 24v, use 2X)
3
.
After over discharged, the controller will resume to work while you press the power switch, note the battery
voltage needs to be over 12.5V.
To correct problem
1. Check wires
2. Reduce amps if needed
3. Reset controller
Disconnect battery +
Reconnect battery +
RATINGS (12V or 12/24V auto work)
EPHC-5 5 Amps for Solar and Load
EPHC-10 10 Amps for Solar and Load
NOTES: For use with solar panels only
TECHNICAL INFORMATION
Regulations point 14.4 Volts
Low voltage Disconnect 11.1V Volts
Low voltage Reconnect 13.1 Volts
Note: all is for 12V system only, use 2x for 24 Volt system
Microcontroller digital accuracy
Type of Charging Series PWM & stat of charge(SOC)
4 Stages: equalization, PWM, Boost and Float,
temperature compensated charging
Electronic protections Short circuit and over current-solar and load
Reverse polarity-solar, load, battery
Reverse current at night
Limits high voltage to protect loads
Lighting protection
Tropicalization Conformal coated printed circuit board
Terminals For wire sizes to 6mm²
Weights 160g
Self-consumption 6mA maximum
Temperature -35℃to 55℃
Enclosure IP22
Warranty 1 years
Compliance CE