SOLAR TRANSMISSION % & POWER MEASUREMENTS
2 2
CHOICE OF (BTU/HR*FT ) OR (W/M )
AUTO-POWER-OFF FEATURE TO CONSERVE BATTERY
MEMBRANE STYLE POWER SWITCH
REAL-TIME READINGS CONTINUALLY UPDATED
DIGITAL TECHNOLOGY WITH EXCELLENT RESOLUTION
MICROPROCESSOR CONTROL
NO ADJUSTMENTS OR CALIBRATIONS NECESSARY
END-MOUNTED SENSOR
The Digital "SOLAR TRANSMISSION & POWER METER" incorporates two meters into
one. In Power Mode, the meter measures the power per unit area of incident solar
radiation reaching the meter's sensing area. In Transmission Mode, the SP2080 is
able to calculate the solar transmission percentage associated with a given
material. The meter uses a state-of-the-art sensor coupled with microprocessor
controltoachieveanEASYTOREADhand-heldmeter. Thedevicemaybeusedto
measurethesolarcharacteristicsofwindows,filmorothertransparentmaterials.
GENERAL DESCRIPTION:
FEATURES:
MODEL# SP2080 MADE IN THE USA
LIGHT
SENSOR
sp2080.cdr
SP2080 WARRANTY
Themanufacturerwarrants all models of the SP2080 tobefreefromdefectsinmaterial and
workmanshipundernormal use and service as specified within the operator's manual. The
manufacturer shall repair or replace the unit within six (6) months from the original date of
shipment after the unit is returned to the manufacturers factory, prepaid by the user, and
the unit is disclosed to the manufacturers satisfaction, to be thus defective. This warranty
shall not apply to any unit that has been repaired or altered other than by the
manufacturer. The aforementioned provisions do not extend the original warranty period
of the unit which has been repaired or replaced by the manufacturer. Batteries are not
coveredbywarrantyaswellasdamagecausedbyover-heatingthedevice.
The manufacturer assumes no liability for the consequential damages of any kind through
the use or misuse of the SP2080 product by the purchaser or others. No other obligations or
liabilitiesareexpressedorimplied. Alldamageorliabilityclaimswillbelimitedtoanamount
equaltothesalepriceoftheSP2080.
POWER/TRANSMISSION %
SELECTOR SWITCH
POWER
BUTTON
BATTERY REPLACEMENT
CALIBRATION
The SP2080 is powered by a 9 volt battery. When the battery voltage is getting too
low to operate the meter, the display will begin blinking. Once the display begins
blinkingyouwillwanttoreplacethebatterysoon. Toreplacethebattery,turnoffthe
power meter. Remove the battery cover near the bottom of the meter and
replace with a new battery. Alkaline batteries will provide the longest service, but
arenotrequiredforthisproduct.
This instrument has been calibrated to detect the total incident solar power of the sun.
The largest incident value of solar power is obtained when the end of the meter faces
the sun directly. When the end of the meter does not face the sun, the incident solar
power is reduced by the cosine curve of the angle to the sun. Make sure the
transparentmaterialsbeingtestedarereasonablyclean.
This instrument is factory calibrated to a NIST (NATIONAL INSTITUTE OF STANDARDS AND
TECHNOLOGY) traceable thermopile and should require no field adjustment.
KEEP THE COMPETITIVE EDGE WITH PRODUCTS FROM
745 Capital Commons Drive
Toledo, Ohio 43615 USA
PHONE: (419) 861-1030 FAX: (419) 861-1031
UNIT OF MEASURE
INDICATOR LEDS
1. If taking measurements near a heat lamp, do not place the meter too close to the
light source. If the end of the meter begins to feel hot to the touch, it is too close to the
light source. Extended periods of heat exposure can cause deformation of the filters,
resulting in a change in the accuracy of the meter. It is recommended that the heat
lampandmeterareseparatedbyatleast18inches(46cm).
2. When taking measurements for transmission percentage or comparative tests, it is
important that the meter is held in the exact same position for both measurements
(when possible). Any change in angle or proximity to your light source can adversely
affect the accuracy of your measurements. FOR BEST RESULTS, place the meter on top
of a stand (#SP2075). It is best to leave the heat lamp and meter stationary, while
sliding the glass sample in between them. This will guarantee the most accurate
measurementspossible.
3. Whenperformingtests,itisadvisedtotakemultiplereadingstoreducetheamountof
error that occurs. Be aware that a changing light source (sun with moving clouds) will
affectyourmeasurements.
4. Thelight sensoris locatedatthetopend ofthe enclosure. Forthe greatestaccuracy
inmeasurements,thissensor shouldbedirectlyfacing thelightsource. DONOTalterthe
condition of the sensor opening by touching or pushing on the filter. Any modifications
oralteringoftheexteriorsurfaceofthewhitefilterWILLaffectthecalibrationofthemeter.
Thisarea shouldbe keptclean atall times. Compressed airor alint-freecloth shouldbe
usedtocleanthefiltersurfaceifitbecomessoiled.
5. Do not attempt to open the enclosure. Opening the enclosure will void the product
HELPFUL OPERATING TIPS
TRANSMISSION & POWER METER
SOLAR