manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Teledyne Lecroy
  6. •
  7. Measuring Instrument
  8. •
  9. Teledyne Lecroy Everywhereyoulook SierraNet M168 User manual

Teledyne Lecroy Everywhereyoulook SierraNet M168 User manual

Introduction
The SierraNet M168 is Teledyne LeCroy's 10 Gigabit Ethernet and 16 Gigabit Fibre Channel Analyzer and Jammer
platform. It has eight SFP+ 10 GigE / 16G FC ports. Up to 64 GB of capture memory allows for capturing of extensive
line-speed data.
The SierraNet M168 ports allow signals to pass through without re-timing, ensuring that the test platform is as transparent
as possible. The analyzer can be controlled either via a one (1) Gigabit Ethernet connection to the local network or via a
USB connection. The SierraNet M168 provides the user with easy-to-understand control panel and LED indicators.
Major features of the M168 include triggering on back-to-back events, use of counters within trigger conditions, and
multi-state (up to 24) triggering and filtering state machines with four transitions per state.
The Net Protocol Suite software for controlling the analyzer and displaying the captured data installs on the latest
Microsoft® Windows®. See the Readme file for the latest information on host-machine requirements.
Components
The analyzer package includes the following components:
SierraNet M168 Analysis platform
USB 3.0 cable, 1 meter
USB 2.0 cable, 1.8 meter
1 Gigabit Ethernet cable, 10 feet
Three prong AC power cord
C13-C14 10A power cord, 2 meter
Installation DVD-ROM with software and documenta-
tion
2
Unpacking the Analyzer
Inspect the received shipping container for any damage. Unpack the container and account for each of the system
components listed on the accompanying packing list. Visually inspect each component for absence of damage.
In the event of damage, notify the shipper and Teledyne LeCroy. Retain all shipping materials for shipper’s inspection.
3
SierraNet M168 Protocol Analyzer
Please see the SierraNet M168 User Manual on the installation DVD-ROM for component specifications and further
1
SierraNet™ M168
Quick Start
Before Starting
Use this document for quick installation and setup. If you
experience problems or need more information, see the
SierraNet M168 User Manual on the Installation DVD-ROM or at
the Teledyne LeCroy web site. For details about the latest
software version, see the Readme file on the
Installation DVD-ROM.
Front Panel Description
Features
The Analyzer has the following features on the front:
[1] LED Indicators for P1-P4 and P5-P8 for Speed, Link and
Status:
Speed LEDs
The LEDs for SPEED illuminate as follows:
GBE Fibre Channel
Yellow Reserved 4G/2G/1G FC
Green 10 GigE 8G FC
Blue N/A 16G FC
Link Activity LEDs
Green Network activity Detected
Yellow Link up, no activity
No Color No link
Status LEDs
Yellow Blinking Waiting for trigger
Yellow Solid Triggered
Red Error detected
No Color No Activity
Please see the SierraNet M168 User Manual for details on
the Speed, Link and Status LEDs.
[2] Power Switch
[3] Status and Configuration LCD Display
[4] Front Panel 5-Buttons keypad
[5] SFP+ 10 GigE / FC connectors for ports 1-4
[6] SFP+ 10 GigE / FC connectors for ports 5-8
[7] External Trigger Input (Trigger In)
[8] External Trigger Output (Trigger Out)
[9] USB Port for host connectivity
[10] Ethernet Port for network connectivity
23 896
1
1057
111
4
4
Front Panel Buttons
The following parameters can be viewed and/or configured directly on the front panel, using the display and 5 button keypad:
5
Installing the Software
1. Insert the Installation DVD-ROM into the DVD drive on the host machine. The installation automatically starts setup,
unless Auto Run is off. In that case, select the DVD-ROM from “My Computer” and click Setup. Follow the instructions
to complete the installation.
Note: If you get an error message during installation of the drivers, consult your system administrator.
7
- Display of IP address
- Display of model name: “SierraNet M168”
- Connection status
- Display of unit name
- IP configuration
• IP mode dynamic, or
• IP mode static
Rear Panel Description Expansion Slot
The analyzer expansion slot at the back of the SierraNet M168
system can accommodate the SYNC Expansion Card that can be
used to daisy-chain multiple analysis systems.
Note: Do not open the enclosure except for adding expansion
cards. No user serviceable parts are inside.
6
8
Starting the Application
To launch the software, select Start > All Programs > LeCroy > Net Protocol Suite.
Select Menu > Setup > Device Management (see screen capture on the right) to display
the Device Management dialog. Click Refresh Device List (see screen captures below) to
display all the devices on the network. Select a device and click Connect.
To start using the protocol analyzer and software, see the Protocol Analyzer chapter of the SierraNet M168 User Manual.
9
Setting Up and Connecting
Note: You must install the software before connecting the
analyzer to the host machine for the first time.
To set up the analyzer:
1. Connect the analyzer to a 100V–240V, 50Hz–60Hz,
power outlet and turn on the Power switch.
At power on, the analyzer will go through initialization
as shown on the LCD display.
2. Connect the USB cable between the SierraNet M168
USB port and a USB port on the host machine. The
host machine operating system detects the analyzer
and loads the driver files. (See Section 10 for how to
connect via Ethernet.)
3. Connect your devices using SFP+ optics and a fiber
cable suitable for your setup.
4. Connect the Ethernet or Fibre Channel devices to port
pairs P1/P2, P3/P4, P5/P6 and/or P7/P8.
For an illustration of the cabling, see the Introduction
chapter of the SierraNet M168 User Manual.
Teledyne LeCroy Customer Support
Online Download
Periodically check the Teledyne LeCroy Protocol Solutions web
site for software updates and other support related to this product.
Web: teledynelecroy.com/tm/software/PSG
E-mail: [email protected]
Support: teledynelecroy.com/support/contact
Trademarks and Servicemarks
LeCroy and SierraNet M168 are trademarks of Teledyne LeCroy.
Microsoft and Windows are registered trademarks of Microsoft Inc.
All other trademarks are property of their respective companies.
Changes
Product specifications are subject to change without notice.
Teledyne LeCroy reserves the right to revise the information in this
document without notice or penalty.
© 2013 Teledyne LeCroy, Inc. All rights reserved. Part Number: 922747-00 Rev. E
This document may be printed and reproduced without additional permission, but all copies should contain this copyright notice.
Operating the SierraNet M168 System
It is recommended that you read the SierraNet M168 User Manual before operating the system, to get familiar with the
capabilities and settings. The default capture mode is ‘Easy Mode’ on the Analyzer's Triggering/Filtering Settings.
Getting Started with Protocol Analysis
To use the SierraNet M168 software for protocol analysis, select File > New Project for a new protocol analyzer project or
open one of the sample projects from the Examples folder (look for a .gep file).
11
Connecting the Platform to the Host Machine via Ethernet
The SierraNet M168 platform can be connected to the host machine by using either a USB cable (as described in Section
8) or by using a1 GbE connection as described below.
Connecting via Ethernet
To connect to the Ethernet network, the Sierra M168 must be assigned an IP address. The IP address can be assigned
automatically, if the network has a DHCP server, or assigned manually using either the front-panel keypad and display or
the Net Protocol Suite software.
IP Address Configuration
The IP address can be configured either via the front panel buttons or using the application when the analyzer is connected
to the host machine via a USB cable.
When connected to a network, the analyzer can communicate with the DHCP server in order to obtain its IP address
configuration.
Once the IP Address is configured, the SierraNet M168 analyzer is automatically detected by the application if the analyzer
and the host machine on which the application is running are on the same Ethernet subnet. A list of all available units are
displayed in the Find Devices dialog.
If the analyzer and the host machine are located on different subnets then the IP address of the analyzer needs to be
configured manually in the application: Use the Add Device feature by clickling the Add Device button in the Select Device
window.
LCD Display
10

Other Teledyne Lecroy Measuring Instrument manuals

Teledyne Lecroy Everywhereyoulook ZS4000 User manual

Teledyne Lecroy

Teledyne Lecroy Everywhereyoulook ZS4000 User manual

Teledyne Lecroy Frontline 802.11 Mounting instructions

Teledyne Lecroy

Teledyne Lecroy Frontline 802.11 Mounting instructions

Teledyne Lecroy PP006C User manual

Teledyne Lecroy

Teledyne Lecroy PP006C User manual

Teledyne Lecroy PP011-2 User manual

Teledyne Lecroy

Teledyne Lecroy PP011-2 User manual

Teledyne Lecroy PCI Express Gen 4x8 OCuLink User manual

Teledyne Lecroy

Teledyne Lecroy PCI Express Gen 4x8 OCuLink User manual

Teledyne Lecroy RP2060 User manual

Teledyne Lecroy

Teledyne Lecroy RP2060 User manual

Teledyne Lecroy AP015 User manual

Teledyne Lecroy

Teledyne Lecroy AP015 User manual

Teledyne Lecroy PP009 User manual

Teledyne Lecroy

Teledyne Lecroy PP009 User manual

Teledyne Lecroy BPA 600 User manual

Teledyne Lecroy

Teledyne Lecroy BPA 600 User manual

Teledyne Lecroy HVD3000 Series User manual

Teledyne Lecroy

Teledyne Lecroy HVD3000 Series User manual

Teledyne Lecroy ZS Series User manual

Teledyne Lecroy

Teledyne Lecroy ZS Series User manual

Teledyne Lecroy Frontline Sodera LE User manual

Teledyne Lecroy

Teledyne Lecroy Frontline Sodera LE User manual

Teledyne Lecroy Everywhereyoulook CP030B User manual

Teledyne Lecroy

Teledyne Lecroy Everywhereyoulook CP030B User manual

Teledyne Lecroy MDA800A User manual

Teledyne Lecroy

Teledyne Lecroy MDA800A User manual

Teledyne Lecroy Frontline NFC-F User manual

Teledyne Lecroy

Teledyne Lecroy Frontline NFC-F User manual

Teledyne Lecroy WaveRunner 8000-R User manual

Teledyne Lecroy

Teledyne Lecroy WaveRunner 8000-R User manual

Teledyne Lecroy CP030 User manual

Teledyne Lecroy

Teledyne Lecroy CP030 User manual

Teledyne Lecroy Frontline Sodera LE User manual

Teledyne Lecroy

Teledyne Lecroy Frontline Sodera LE User manual

Teledyne Lecroy HVFO103 User manual

Teledyne Lecroy

Teledyne Lecroy HVFO103 User manual

Teledyne Lecroy DL03-ISO User manual

Teledyne Lecroy

Teledyne Lecroy DL03-ISO User manual

Teledyne Lecroy M21 User manual

Teledyne Lecroy

Teledyne Lecroy M21 User manual

Teledyne Lecroy WavePulser 40iX User manual

Teledyne Lecroy

Teledyne Lecroy WavePulser 40iX User manual

Teledyne Lecroy PP011-1 User manual

Teledyne Lecroy

Teledyne Lecroy PP011-1 User manual

Teledyne Lecroy Frontline Sodera LE User manual

Teledyne Lecroy

Teledyne Lecroy Frontline Sodera LE User manual

Popular Measuring Instrument manuals by other brands

Reflex Fillmeter Installation, operating and maintenance instructions

Reflex

Reflex Fillmeter Installation, operating and maintenance instructions

Siemens SMART 7KT manual

Siemens

Siemens SMART 7KT manual

Bender NGRM500 quick start guide

Bender

Bender NGRM500 quick start guide

Endress+Hauser Proline Promag 50H technical information

Endress+Hauser

Endress+Hauser Proline Promag 50H technical information

Gigahertz Solutions HF38B manual

Gigahertz Solutions

Gigahertz Solutions HF38B manual

Vision metering Sentry 950 user manual

Vision metering

Vision metering Sentry 950 user manual

Tatsuta Electric Wire & Cable AD-AS-5DRM Operation manual

Tatsuta Electric Wire & Cable

Tatsuta Electric Wire & Cable AD-AS-5DRM Operation manual

HBS GQ-20A1 installation guide

HBS

HBS GQ-20A1 installation guide

Extech Instruments CO100 user manual

Extech Instruments

Extech Instruments CO100 user manual

Systec Controls deltawaveCoG-F manual

Systec Controls

Systec Controls deltawaveCoG-F manual

PCE Instruments PCE-310 manual

PCE Instruments

PCE Instruments PCE-310 manual

YOKOGAWA Power Series Plus user manual

YOKOGAWA

YOKOGAWA Power Series Plus user manual

Thoth Technology Argus 2000 owner's manual

Thoth Technology

Thoth Technology Argus 2000 owner's manual

PureAire ST-46 LEL instruction manual

PureAire

PureAire ST-46 LEL instruction manual

Common Sense RC Cell Spy 8 User guide and manual

Common Sense RC

Common Sense RC Cell Spy 8 User guide and manual

SmartDHOME MyPM01S user manual

SmartDHOME

SmartDHOME MyPM01S user manual

Endress+Hauser Proline Promag W 800 operating instructions

Endress+Hauser

Endress+Hauser Proline Promag W 800 operating instructions

EXFO PPM-350C user guide

EXFO

EXFO PPM-350C user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.