Solas PV-800HZ User manual

THIS POWER VENT KIT IS ONLY FOR USE WITH THE FOLLOWING MODELS:
SEE-THRU MODELS: BI-48-ST, BI-60-ST, BI-72-ST
SINGLE SIDE MODELS: BI-48-SSL, BI-48-SSR, BI-60-SSL, BI-60-SSR, BI-72-SSL, BI-72-SSR
DIRECT
VENT
POWER VENT KIT
PART #PV-800HZ AND PV-850V
Report #0361GF006S
Ce manual est disponsible en Francais sur demande.
PV-800HZ SHOWN

TABLE OF CONTENTS
Power Vent Kit Contents 2
Power Vent Clearances 3
Venting Configurations 5
Horizontal (side wall) Venting 6
Vertical (through roof) Venting 8
Control Installation Instructions 11
Electrical Instructions 15
Replacement Parts List 16
Warranty Information 17
WE STRONGLY SUGGEST THAT YOU READ THIS MANUAL THOROUGHLY BEFORE BEGININNG THE
INSTALLATION OF THE SÓLAS POWER VENT KIT. THIS SPECIFIC PRODUCT HAS ITS OWN UNIQUE SET-
UP AND INSTALLATION REQUIREMENTS THAT MUST BE FOLLOWED EXACTLY. PLAN YOUR
INSTALLATION IN ADVANCE BY CAREFULLY RE-VIEWING ALL THE INFORMATION CONTAINED IN THIS
MANUAL.

2
POWER VENT KIT CONTENTS
This kit can only be used in conjunction with the SÓLAS Contemporary Fire products listed below. This
installation must conform with local codes, or, in the absence of local codes, with the National Fuel Gas
Code, ANSIZ2223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.
THIS POWER VENT KIT IS ONLY FOR USE WITH THE FOLLOWING SÓLAS MODELS:
SEE-THRU MODELS: BI-48-ST, BI-60-ST, BI-72-ST
SINGLE SIDE MODELS: BI-48-SSL, BI-48-SSR, BI-60-SSL, BI-60-SSR, BI-72-SSL, BI-72-SSR
CONTENTS OF POWER VENT KIT
ITEM PART# DESCRIPTION QTY.
ITEM PART# DESCRIPTION QTY.
1 HRD-800HZ HORIZONTAL
POWER VENT KIT 1 6 HRD-805 ADJUSTABLE RESTRICTOR 1
2 HRD-801 VENT ADAPTER W/
PRESSURE TAP 1 7 HRD-806 PRESSURE SWITCH TUBING 1
3 HRD-802 HARDWARE KIT 1 8 HRD-850V OPTIONAL VERTICAL
TERMINATION CAP 1
4 HRD-803 POWER VENT RELAY
HARNESS 1 9 HRD-851V OPTIONAL VERTICAL
TERMINATION BOX 1
5 HRD-804
POWER VENT
CONTROL W/
PRESSURE SWITCH
1 10 HRD-852V
OPTIONAL VERTICAL
TERMINATION HARDWARE
KIT
1
This kit uses either M&G Duravent direct vent pipe, Secure Vent direct vent pipe, or Selkirk Direct-
temp vent pipe with a 4” inner pipe and a 6” outer pipe.
Vertical installations must use the optional HRD-850V vertical termination cap. HRD-850V includes
HRD-851V vertical termination box, and HRD-852V vertical termination hardware kit. The vertical
termination box can only be installed on flat surfaces; sloped surfaces require construction of a chase
which provides the minimum interior square opening of 11”x11” (279mm x 279mm) for the venting and
wiring to pass through. Flat roofs may require a chase depending on local codes and roof construction.
(If in doubt check with local inspector)
ALWAYS MAINTAIN 1.5” (38mm) CLEARANCE TO COMBUSTIBLES AROUND VENT PIPE.
The Power Vent termination must be located in accordance with the clearances outlined in the venting
section of this manual on page 3.
For replacement parts, refer to page 9. Replacement parts can be ordered through your authorized
SÓLAS dealer.

3
POWER VENT CLEARANCES
Figure #1
A. clearances above grade, veranda, porch, deck, or balcony [*12 inches (30 cm) minimum]
B. clearance to window or door that may be opened [* 12 inches (30 cm) minimum]
C. clearance to permanently closed window [minimum 12 inches (30 cm) recommended to prevent condensation on
window]
D. vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (60 cm) from the
edge of the terminal [12 inches (30 cm) minimum]
E. clearance to unventilated soffit [12 inches (30 cm) minimum]
F. clearance to outside corner [6 inches (15 cm) minimum]
G. clearance to inside corner [6 inches (15 cm) minimum]
H. * not to be installed above a meter/regulator assembly within 3 feet (90 cm) horizontally from the center-line of the
regulator
I. clearance to service regulator vent outlet [* 6 feet (1.8 m) minimum]
J. clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance [* 12
inches (30 cm) minimum]
K. clearance to a mechanical air supply inlet [* 6 feet (1.8 m) minimum]
L. ^ clearance above paved side-walk or a paved driveway located on public property [* 7 feet (2.1 m) minimum]
M. clearance under veranda, porch, deck, or balcony [12 inches (30 cm) minimum**]
^ a vent shall not terminate directly above a side-walk or paved driveway which is located between two single family
dwellings and serves both dwellings*
** only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the floor*
* as specified in CGA B149 Installation Codes, Note: local Codes or Regulation may require different clearances
* for U.S.A. Installations follow the current National Fuel Gas Code, NSI Z223.1

4

5
VENTING CONFIGURATIONS
Maximum vent length is 110 ft.
plus six 90-degree elbows or
combination of other elbows
equaling 90-degrees, with a
maximum 66ft vertical rise.
Minimum horizontal vent length
is 3 ft. plus one 90-degree elbow.
The vent can be installed with
any combination of rise and run
between the figures including up
to 3 ft. below the unit.
Figure #2
WARNING:
A minimum clearance to combustibles of 1.5” (38mm) is required around the vent pipe at all times.
Failure to maintain this clearance may result in property damage, injury, or death.
Figure #3
NOTE:
IT IS PERMISSABLE TO VENT HORIZONTALLY, DIRECTLY OFF OF THE UNIT, NO VERTICAL RISE IS
REQUIRED WHEN EQUIPPED WITH A POWER VENT AS SHOWN IN FIGURE #3.
Maximum venting – 110ft
plus (6) 90 degree elbows.

6
HORIZONTAL (SIDE WALL) VENTING
This kit uses either Simpson Duravent GS direct vent pipe, Secure Vent direct vent pipe or Selkirk
Direct-temp vent pipe with a 4" inner pipe and a 6" outer pipe.
1. Locate the power vent termination following
the clearance to combustible table, venting
configuration diagram (Fig. #2 & 3), and
terminal location diagram (Fig. #1).
2. Cut and frame an 11" x 11" opening. The center
of the square hole should line up with the
center
3. Install the M&G Duravent (or equivalent) Wall
thimble, part number 46DVA-WT (not supplied
with kit) in the opening to retain any insulation
in the wall and maintain proper clearances. If
the wall being penetrated is constructed of
noncombustible material only (i.e., Masonry
block or concrete) the wall thimble is not
required and a hole with zero clearance is
acceptable. (6 5/8” hole)
Figure #4
4. Attach the terminal to the outside wall. Ensure that the terminal is the right way up and that only
the outer flanges that are used to secure the terminal to the building are covered by the exterior
wall or siding. (Fig.#4) Note: No other part of the terminal can be recessed into the exterior
wall or siding.
5. Attach the vent adaptor directly to the appliance after the initial 45⁰elbow before any
horizontal or vertical pipe is added. Tape all exterior seams on the venting system with foil HVAC
tape. Note: The inner pipe does not need to be sealed. (Fig. #5)
6. Connect the high temperature silicone tube to the vacuum pressure tap on the adaptor, secure
with the hose clamp provided and route the tube through the utility access panel back to Power
vent control location. (Fig. #5) Tube may touch unit and be trimmed if required. Connect the
pressure switch tubing to the light grey port on the power vent control. Note: Ensure that there
are no blockages in this tube, as this will cause the control to malfunction. Do not allow tube to
rest on firebox after it is routed.
7. Run the required Simpson Duravent GS / Secure Vent / Selkirk Direct-temp pipe from the adaptor
to the terminal assembly. Assemble as per the vent pipe manufacturer’s instructions.

7
Figure #5

8
VERTICAL (THROUGH ROOF) VENTING
INSTALLATION
All part numbers in the following section are shown
in Fig. #6.
1. Place the flashing (Part A) onto the chase and
seal using silicone.
2. Put a bead of silicone on the underside of the
vertical standoff (Part B) and place it on top
of the flashing. Align the eight holes and
secure both parts to the chase using eight #8
x 1 1/2" screws provided.
3. Install the drip shield (Part C) onto the top of
the vertical standoff using a bead of silicone
between the two. Do not screw this part in
place.
4. Bring the 14-2 electrical wire (not supplied)
up through the holes in both the flashing and
the drip shield leaving at least 12" of excess
wire above the drip shield.
5. IMPORTANT: Attach an appropriate length(s)
of the vent to the power vent terminal,
sufficient to pass through the chase. Note: do
not connect an adjustable length vent pipe
to the terminal.
Note: do not connect an adjustable length
vent pipe to the terminal.
6. Seal the connection of the first length of pipe
at the terminal and any other pipe to pipe
joint by both screwing and taping the outside
joint using high temperature foil tape.
7. Remove the junction box cover. (Part D)
8. Remove and discard the exhaust shield. (Part
E)
9. Apply a bead of silicone on the “Part A
Flashing” of the power vent terminal (HRD-
850V)
10. Slide the vent through the drip shield and at
the same time thread the electrical lead
through the hole in the bottom of the
terminal.
each side of the vertical standoff, the drip shield and
the power vent terminal and then screw them
together using the eight #8 x 1/2" stainless screws
provided.
12. Join the 14-2 wire lead to the blower wires
using the appropriate connectors and attach
the ground wire. Reinstall the junction box
cover.
13. Install the vertical rain cap (Part F) over the
power vent blower. ALIGN THE EXHAUST
OUTLET ON THE POWER VENT TERMINAL
WITH THE EXHAUST PORT ON THE VERTICAL
RAIN CAP.
14. Secure the vertical rain cap to the power vent
blower with the remaining eight #8 x 1/2"
stainless screws.
Note: there are no pilot holes in the base of the
power vent terminal. 1/8" diameter pilot holes
should be drilled using the holes in the vertical
rain cap as a guide.
Do not silicone the vertical rain cap to the power
vent terminal as it needs to be removable for
servicing.
15. Attach the vent adaptor directly to the
appliance with three screws and seal outer
pipe with aluminum tape provided. Note:
The inner pipe does not need to be sealed.
16. Connect the high temperature silicone tube
to the vacuum pressure tap on the adaptor,
secure with the hose clamp provided and
route the tube through any hole back to
Pressure Switch. (Fig. #5) Note: Ensure that
there are no blockages in this tube, as this
will cause the control to malfunction.
17. Run the required M&G Duravent GS / Secure
Vent / Selkirk Direct-temp pipe from the
adaptor to the terminal assembly. Assemble
as per the vent pipe manufacturer’s
instructions.

9
11.
With the power vent terminal resting on the
drip shield, align the eight holes in

10
VERTICAL (THROUGH ROOF) VENTING
Final Installation Height: 21” Figure 6

11
CONTROL INSTALLATION INSTRUCTIONS
The above image shows the power vent control
with pressure switch, part #HRD-804.
The image below shows the pressure switch
ports on the top surface of the power vent
control enclosure. The black port should be left
open to the atmosphere; the grey port should be
connected to the vent pipe pressure tap. The
pressure switch requires a positive pressure of
0.05” W.C. to confirm the power vent is running.
There are 2 female connectors on the bottom
surface of the power vent control enclosure as
shown above. The left connector is for the power
vent relay harness part #HRD-803. The right
connector is for outgoing power to the power vent
blower at the vent termination. (see below).
Connect the White, Black, and Green lines of the
14-2 power line running to the power vent as
shown in the image below. This connector is
included in your hardware kit part #HRD-802.

12
CONTROL INSTALLATION INSTRUCTIONS
Install the power vent control HRD-804 on the flue
side of the fireplace using the (3) #10 x 3/4” self-
tapping sheet metal screws provided.
Hardware Kit, HRD-802
Install the vent adapter HRD-801 with pressure
tap immediately following the 45⁰elbow off the
unit. Connect the pressure tap on the vent
adapter to the light grey port on the control using
the pressure switch tubing HRD-806 provided.
Tape all seams in the venting system using
Aluminum Foil HVAC Tape.
Use the adjustable restrictor HRD-805 (shown
below) to reduce the draft within the firebox
should the power vent be overpowering the
fireplace. Once the desired level of restriction is
found, secure the restrictor using (2) #10 x 3/4”
self-tapping sheet metal screws provided.

13
CONTROL INSTALLATION INSTRUCTIONS
Power Vent Relay Harness HRD-803
Plug in the power vent relay harness HRD-803 to
the AUX port on the fireplace control.
Connect the red wire spade connector from the
power vent relay harness HRD-803.
Cut the Red TC spade connector off, Crimp on the
male quick disconnect connector included in
your hardware pack HRD-802.

14
Disconnect the Red TC spade connector.

15
ELECTRICAL INSTRUCTIONS
NOTE: Once the electrical wiring has been completed, test the system to be sure its performance is as
desired before the finishing work is completed and the fireplace is enclosed.
WARNING
All electrical shall be completed by a licensed Electrician and must conform with local building code.
Improper installation may result in property damage, injury, or loss of life.
Caution: Label all wires prior to disconnection when servicing the controls. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.

16
REPLACEMENT PARTS LIST
REPLACEMENT PARTS
ITEM PART# DESCRIPTION QTY.
ITEM PART# DESCRIPTION QTY.
1 HRD-800HZ HORIZONTAL
POWER VENT KIT 1 6 HRD-805 ADJUSTABLE RESTRICTOR 1
2 HRD-801 VENT ADAPTER W/
PRESSURE TAP 1 7 HRD-806 PRESSURE SWITCH TUBING 1
3 HRD-802 HARDWARE KIT 1 8 HRD-850V OPTIONAL VERTICAL
TERMINATION CAP 1
4 HRD-803 POWER VENT RELAY
HARNESS 1 9 HRD-851V OPTIONAL VERTICAL
TERMINATION BOX 1
5 HRD-804
POWER VENT
CONTROL W/
PRESSURE SWITCH
1 10 HRD-852V
OPTIONAL VERTICAL
TERMINATION HARDWARE
KIT
1
NOTE:
Items 8, 9 and 10 are supplied as a kit and cannot be ordered separately.
For replacement parts and customer service contact your SÓLAS dealer or:
SÓLAS, LLC
4 Technology Drive, Suite 5
West Lebanon, NH 03784
(T) 603-298-5169
(F) 603-298-9246

17
WARRANTY INFORMATION
THE WARRANTY
SÓLAS, LLC, a division of Progressive Manufacturing, Inc. (“SÓLAS”), Limited Lifetime
Warranty warrants your SÓLAS brand gas fireplace (“Product”) to be free from defects
in materials and workmanship at the time of manufacture. The Product body and
firebox carry the Limited Lifetime Warranty on workmanship defects causing loss of
structural integrity. Ceramic glass carries the Limited Lifetime Warranty against
thermal breakage only. After installation, if covered components manufactured by
SÓLAS are found to be defective in material or workmanship during the Limited
Lifetime Warranty period and while the Product remains at the site of the original
installation, SÓLAS will, at its option, repair or replace the covered components. If
repair or replacement is not commercially practical, SÓLAS will, at its option, refund
the purchase price or wholesale price of the SÓLAS product, whichever is applicable.
SÓLAS will also pay their prevailing labor rates, as determined in its sole discretion,
incurred in repairing or replacing such components during the warranty period.
THERE ARE EXCLUSIONS AND LIMITATIONS to this Limited Lifetime Warranty as
described herein.
COVERAGE COMMENCEMENT DATE
Warranty coverage begins on the date of installation. The warranty shall commence
no later than 24 months following the date of product shipment from SÓLAS,
regardless of the installation date.
EXCLUSIONS AND LIMITATIONS
This Limited Lifetime Warranty applies only if the Product is installed in the United
States or Canada and only if operated and maintained in accordance with the printed
instructions accompanying the Product and in compliance with all applicable
installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product
must be purchased through a listed supplier of SÓLAS and proof of purchase must be
provided. The Product body and firebox carry the Limited Lifetime Warranty. The
following do not carry the Limited Lifetime Warranty, but are warranted as follows:
•Burner – Repair or replacement for three years from date of installation.
•Gas components & electrical components –Repair or replacement for
one year from date of installation.
•Blowers & remote controls –Repair or replacement for one year from
the date of installation.
•Porcelain Firebox Liners –Replacement for one year against cracking
or breakage due to thermal stress from date of installation. Excludes
surface and hairline cracks and scratches or slight color changes that do
not affect the operation or safety of the unit.
•Gaskets – Repair or replacement for one year from the date of
installation.
•Surrounds – Replacement for one year against cracking or breakage
due to thermal stress. Excludes surface and hairline cracks and
scratches or slight color changes that do not affect the operation or
safety of the unit.
•Labor coverage –Prevailing SÓLAS rates apply for the warranty period
of the component. SÓLAS will not be liable for travel costs for service
work.
SÓLAS will not be responsible for: (a) damages caused by normal wear and tear,
accident, riot, fire, flood, or acts of God; (b) damages caused by abuse, negligence,
misuse, or unauthorized alteration or repair of the Product affecting its stability or
performance. The Product must be subjected to normal use. The product is designed
to burn either natural or propane gas only. Burning conventional fuels such as wood,
coal or any other solid fuel will cause damage to the Product, will produce excessive
temperatures and could result in a fire hazard. (c) Damages caused by failing to
provide proper maintenance and service in accordance with the instructions provided
with the Product; (d) damages, repairs or inefficiency resulting from faulty installation
or application of the Product.
Discoloration and some minor expansion, contraction, or movement of certain parts
and resulting noise is normal and not a defect, and, therefore, not covered under
warranty. The installer must ensure the appliance is burning as per the rating tag at
the time of installation. Over-firing (operation above the listed BTU rate) of this
appliance can cause serious damage and will nullify this warranty.
This warranty is void if:
a) The unit has been operated in atmospheres contaminated by chlorine,
fluorine or other damaging chemicals.
b) The unit is subject to submersion in water or prolonged periods of
dampness or condensation.
Damage to stainless steel, gold, nickel or porcelain enameled surfaces caused by fingerprints, scratches, melted
items, or other external sources left on these surfaces from the use of cleaners is not covered in this warranty.
SÓLAS is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems,
mechanical ventilation systems, or general construction conditions which may generate negative pressure in the
room in which the appliance is installed. Additionally, SÓLAS assumes no responsibility for drafting conditions
caused by venting configurations, adjoining trees or buildings, adverse wind conditions or unusual
environmental factors and conditions that affect the operation of the unit.
This Limited Lifetime Warranty covers only parts and labor as provided herein. In no case shall SÓLAS be
responsible for materials, components, or construction, which are not manufactured or supplied by SÓLAS or for
the labor necessary to install, repair, or remove such materials, components, or construction. Additional utility
bills incurred due to any malfunction or defect in equipment are not covered by this warranty. All replacement or
repair components will be shipped F.O.B. from the nearest stocking SÓLAS facility.
LIMITATION ON LIABILITY
It is expressly agreed and understood that SÓLAS’ sole obligation and the purchaser’s exclusive remedy under
this warranty, under any other warranty, expressed or implied, or in contract, tort or otherwise, shall be limited
to replacement, repair, or refund, as specified herein.
In no event shall SÓLAS be liable for any incidental or consequential damages caused by defects in the Product,
whether such damage occurs or is discovered before or after repair or replacement, and whether such damage is
caused by SÓLAS’ negligence. SÓLAS has not made and does not make any representation or warranty of fitness
for a particular use or purpose, and there is no implied condition of fitness for a particular purpose.
SÓLAS makes no expressed warranties except as stated in this Limited Lifetime Warranty. The duration of any
implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this Limited Lifetime Warranty or to create for SÓLAS any other obligation or
liability in connection with the Product. Some states and provinces do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitations or exclusions may not apply to you. The
provisions of this Limited Lifetime Warranty are in addition to and not a modification of or subtraction from any
statutory warranties and other rights and remedies provided by law.
INVESTIGATION OF CLAIMS AGAINST WARRANTY
SÓLAS reserves the right to investigate any and all claims against this Limited Lifetime Warranty and to decide, in
its sole discretion, upon the method of settlement.
To receive the benefits and advantages described in this Limited Lifetime Warranty, the appliance must be
installed and repaired by a licensed contractor approved by SÓLAS.
Contact SÓLAS at the address provided herein to obtain a listing of approved dealers/distributors. SÓLAS shall
in no event be responsible for any warranty work done by a contractor that is not approved without first
obtaining SÓLAS’ prior written consent.
HOW TO REGISTER A CLAIM AGAINST WARRANTY
In order for any claim under this warranty to be valid, you must contact the SÓLAS dealer/distributor from which
you purchased the product. If you cannot locate the dealer/distributor, then you must notify SÓLAS in writing.
SÓLAS must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be
directed to the SÓLAS Warranty Department at 4 Technology Drive, Suite 5, West Lebanon, NH 03784 or visit our
website at www. SÓLAS fires.com.
SÓLAS, LLC
4 Technology Drive, Suite 5
West Lebanon, NH 03784
(T) 603-298-5169
(F) 603-298-9246
www.SÓLASfires.com

18
c)
Any damage to the unit, combustion chamber, heat exchanger or other
components due to water or weather damage which is the result of, but
not limited to improper chimney/venting installation.

19
This manual suits for next models