I. Schematic Drawing of Structure:
1. Top Cover
2. Water Tank
3. Hood
4. Body Housing
5. Filter (Optional HEPA Filter)
6. Filter Cover
7. Humidity Sensor
8. Aroma Box
II. Function and features:
• Cool & Warm mist humidifier
• Three humidifying levels (Hi/Medium/Low)
• Timer 12hours
• Night mode, No LED lights to ensure a good night’s sleep.
• Aroma function
• Auto mode to automatically adjust the mist level to maintain a comfortable level of
humidity.
• The humidifier will automatically turn off when there is no water or if the tank cover has
been removed.
• Integrated body design for noise suppression, super quiet when operating.
• Cool mist humidity capacity >300ML/H, Warm mist humidity capacity >450ML/H
• 80 degrees high temperature sterilization function
• Cool mist humidity capacity >300ML/H
• Silver Ion sterilization killing 99.99% of bacteria in the water.
• Demineralization cartridge for longer, admin-free use.
III. Technical Parameters:
Model: SH604E
Rated Max. Moisture Capacity:
450ml/h
Water Tank Capacity: 4.5L
Rated Voltage: 220V
Rated Frequency: 50/60Hz
Rated Power: 155W
Anti-electric shock Protection: Class П
Suitable area: 45M3
V-I. Operation condition
1. The working environment for humidifier is between 0˚C to 50˚C, and relative
humidity lower than 85%RH.
2. Keep machine working at low mist level when room relative humidity is higher
than 70%RH or in an enclosed room space.
3. Use clean water lower than 40˚C (purified water is recommended)
4. The water tank and sink should be cleaned before you stop using it for a long time
V-II. The place environment:
1. Position the humidifier on a firm, flat surface to keep it steady.
2. Place it far away from any heat source, such as stoves or fireplaces.
3. Ensure the humidifier is positioned away from furniture and electronic appliances to
prevent potential damage from mist.
V-III. Operation steps
1. Remove the top cover, lift up the water tank and fill it with water.
2. Plug the device into the socket.
3. Follow the control panel operation instruction for functioning.
4. Refill the tank and turn on the machine.

V-IV. Control panel operation instruction
On/Off:
When the humidifier is plugged in, it will make a buzzer sound which indicates it is in
standby mode. Press the on/off icon to start the humidifier. Press it again to turn it off
and go back into standby mode.
Mist Level:
Adjust the mist level between 1 Droplet (smallest), 2 Droplets, and 3 Droplets (largest)
by pressing this button.
Timer / Sleep Mode:
Press this key to set the timer, one unit per hour. Timer up to 12 hours. When the
unit has reached the set time; the machine will stop working.
Press and hold this key to select the sleep mode, display lights will all automatically.
turn off. Press the key again to cancel sleep mode function.
Auto Mode:
The machine will automatically adjust the mist level to maintain a comfortable level of
humidity with relative humidity of 50%~60%.
Humidistat:
Press this key to set the desirable humidity; Machine will stop working once humidity is at
the required setting. Humidity can be adjusted from 40%~80%RH. When the machine starts
working, it will keep humidifying for 2 mins no matter the room humidity or setting.
Warm Mist:
Press this key to start warm mist function, the PTC element in the machine will start
working, and the outlet mist will become warm, press this key again to stop warm mist
function. When the warm mist function is off, the machine only works with cool mist.
VI. Cleaning
Regular cleaning is essential, especially in areas where the local faucet water is hard. After
several days of use, there may be water scale gathering on the base and the transducer.
Follow these steps for cleaning:
1. Before cleaning, turn off the humidifier and unplug the power cord from the socket.
Remove the water tank and the floater.
2. Add around 50mls of white vinegar solution to the transducer (can be less or more,
based on the water scale condition), and soak for 60-100 minutes.
3. Then clean off the water scale with a soft brush or cloth thoroughly.
4. Wash it with clean water.
When not using the machine for a long period of time, please remove the plug and remove
the water in the water tank and housing. Clean the machine carefully, especially the water
tank, housing, and aroma box, and dry it out, then place it back to the original packing box
and store it in a dry, cool place without direct sunlight.

VII. Safety Items
• The unit will not work without water.
• Do not scratch the mist transducer with hard/sharp objects.
• Turn off the machine and unplug it when there is an abnormal noise or smell.
• Don’t touch the water or parts in the housing while it’s working.
• This machine is NOT a toy, please keep it away from kids to avoid fire, injury, or
electric shock.
• Check the voltage carefully to ensure your home power voltage fits the product.
• Do not use the product in a wet environment, such as a bathroom as it will cause
an electrical shock.
VIII. Troubleshooting
If the machine is not working properly, please refer to the following troubleshooting guide:
Problem
Possible reasons
Solutions
No mist coming
out
Check the plug
Plug into socket properly
Check the power switch
Turn on power switch
No water in the tank
Add water
Not enough water in the tank
Add water until enough
Abnormal smell
mist
New machine
Take off tank cover, place the water tank
in cool and dry place for 12 hours
Dirty water, or water has
not been replaced recently.
Clean water tank, and refill with clean
water
Noise
Tank is in incorrect position
Put the tank in correct position
Less water in tank
Add water
Uneven level for machine
Place it on even or flat ground
Steam out from
nozzle
surrounding
Joint between steam outlet and
water tank
Sink the steam outlet cap in water and
use it again
LED display
shows 72H
The machine has been
working for 72Hs and
requires cleaning.
Press and hold the mist level key for 3
seconds.
If the machine is still not working after checking the possible reasons above, the machine may
have other problems. In this case, you should contact our service repair center at
info@solenco.co.za or call us on 0861 388 878

Table of contents
Other Solenco Humidifier manuals