3.3 Alarm sequence
Turning the alarm on or off is done using the “ALARM on/off” switch. The bell symbol will start flashing on the display when the alarm is triggered. If you press
the “SNOOZE / LIGHT” button during the alarm sound, the alarm will be delayed for five minutes and the Zzsymbol will appear on the display . To switch the
alarm signal off press any other key. You can put off the alarm as many times as you wish. When the alarm rings, no RCC signal is received; its reception will be
resumed once the alarm is turned off. The alarm signal will automatically turn off after two minutes. The volume level will increase four times during the alarm.
3.4 Sensor pairing function
Insert batteries into the sensor and close the cover. When switching the weather station on for the first time, the sensor will be paired automatically. Pairing will
take about three minutes. If the pairing fails, the weather station is probably out of the sensor signal range. Sensor pairing is activated by pressing the “”
button.
3.5 Receiving RCC control signal
Receiving the RCC signal will start automatically after starting or resetting.
Forced RCC signal reception: hold the “” button.
When the signal reception is turned on, a three-minute long synchronization will start. During synchronization, you cannot enter any functions; the
weather station is not performing any measurements now, the USB power outlet is also deactivated the USB power outlet is also deactivated.
Automatic signal reception every day.
Automatic reception will take place at the following daily times: 1:00, 2:00 and 3:00. In case of a failure, the signal reception attempt will be repeated at
4:00 and 5:00. If the signal is successfully received at 4:00, no further reception will take place for the given day. If the signal reception at 4:00 fails, it will be
repeated at 5:00 and, regardless of whether successful or not, it will not be repeated for the given day. The control signal reception process lasts 7 minutes.
The icon will flash in the RCC signal reception mode.
If the signal is weak or if the device is unable to recognize correct signal, the tower symbol will flash but no radio wave symbol will appear.
If the control signal has been successfully received, the full RCC reception icon will illuminate and the device will exit the signal reception mode.
To exit the reception mode, briefly press the “” button.
If alarm is activated in the RCC signal reception mode, the device will exit the reception mode and enter the alarm mode.
After receiving the DST signal, a DST icon will be displayed.
After resetting, the and DST symbols will disappear.
3.6 Display light
If the weather station is running on batteries, pressing the SNOOZE/LIGHT button will illuminate the display for 15 seconds. If the display backlight is weak,
replace the batteries. When running on power adapter, the display may be lit constantly (depending on the backlight intensity setting).
3.7 Display backlight colour setting
When running the device on power adapter, push the “” or “” shortly or longer; use this procedure to set various backlight colours (over 70 colours). Use
the BACKLIGHT switch to set low or high backlight intensity (LO/HI). If you press the “AUTO COLOR” button, the display backlight colours will change
sequentially. If you press the “AUTO COLOR” button again, the display will remain lit with the current colour. It is not possible to change colour when running
the device on batteries.
A
CE
Declaration
o
f
Conformity
is
issued
to
the
pro
duct
in
accordance
wit
h
applicable
regulati
ons.
On
request
from
the
manufacturer:
inf
[email protected],
or
to
download at https://www.solight.cz/documents/te85_prohlášení o shodě.pdf
The maximum radiated power of the device in the working frequency band 433.92MHz is 10mW (+ 10dbm).
Producer: Solight Holding, s.r.o., Na Brně 1972, Hradec Kralove 500 06, Czech Republic.