SOLIS S3-Logger User manual

Ginlong Technologies Co., Ltd.
User Manual
S3-Logger Datalogger

Modification record
Version Date Description Release date Remarks
1V1.0 First official release 21/05/06

Contents
S3-Logger Datalogger User Manual
1.1 Target
3. Product Description
3.1 Product Introduction
1
………………………………………………………………………………………………………………………
1
………………………………………………………………………………………………………………………………………………………………………………………………
1
3
……………………………………………………………………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………………………………………………
3
……………………………………………………………………………………………………………………………………………………………
…………………………………………………………………………………………………………………………………………………………………… 7
1.2 Note
4. Installation Process
5.1 Equipment Disassembly
5.2 Device Installation
……………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………
…………………………………………………………………………………………………………………………………………………………………
8
8
8
5. Mechanical Installation
1.3 Symbol Description ……………………………………………………………………………………………………………………………………………………………… 1
2. Safety Notice ……………………………………………………………………………………………………………………………………………………………………………………… 2
6. Electrical Connections …………………………………………………………………………………………………………………………………………………………… 10
7. Configuration ……………………………………………………………………………………………………………………………………………………………………………………… 12
7.1 Network Configuration ……………………………………………………………………………………………………………………………………………………… 12
7.2 Software Configuration ………………………………………………………………………………………………………………………………………………… 12
8. Routine Maintenance ………………………………………………………………………………………………………………………………………………………………… 20
9. Common Problems ……………………………………………………………………………………………………………………………………………………………………… 21
10.Appendix …………………………………………………………………………………………………………………………………………………………………………………………………… 22
1. About this document …………………………………………………………………………………………………………………………………………………………………… 1
3.2 Application Scenarios Introduction
3
…………………………………………………………………………………………………………………………
4
………………………………………………………………………………………………………………………………………………………………………………
3.3 Appearance
3.4 Power Wiring Diagram ……………………………………………………………………………………………………………………………………………………… 4
5
…………………………………………………………………………………………………………………
3.5 Communication Terminal Description
3.6 Indicator Light Description ……………………………………………………………………………………………………………………………………………… 6
Product Datasheet ……………………………………………………………………………………………………………………………………………………………………… 22

1. About this document
1.2 Note
This manual is applicable to the on-site installation and configuration of S3-Logger data logger,
and requires professional technicians to operate.
1.3 Symbol Description
In order to ensure the safety of users, power grid, and equipment when using this product, the
manual provides relevant warning symbols. Please read it carefully to better use the equipment
and avoid personal and property damage.
1.1 Target
Provide users with detailed product information and installation, operation and maintenance
instructions of S3-Logger.
.1.
This manual is applicable to the following data logger of Ginlong Technology Co., Ltd.
S3-Logger
CAUTION:
Indicates a low potential hazard which, if not avoided, may result in personal injury or
property damage.
Note:
Indicates that there is a low potential danger, if it cannot be avoided, it may cause personal
injury and property damage.
WARNING:
Indicates a moderate potential danger, which may result in personal injury or property
damage if it cannot be avoided.
Danger:
Indicates a high potential danger, which may cause personal injury or property damage if it
cannot be avoided.

2. Safety Notice
.2.
S3-Logger is designed in accordance with international safety regulations in order to ensure
the safety of people, power grid and equipment. As a power electronic product, relevant safety
regulations must be followed in the stages of installation, commissioning, operation, and
maintenance. Improper operation may result in casualties and equipment damage.
Special attention: Only professionals with relevant qualifications can perform installation,
wiring and other operations on this product.
Danger:
Please install and connect this product by professionals with relevant knowledge.

3. Product Description
.3.
3.1 Product Introduction
·S3-Logger is mainly used in industrial and commercial, distributed photovoltaic projects,
safe and reliable, easy to install, flexible networking, multi-device access, intelligent operation
and maintenance.
Easy to install: Desktop installation, rail installation
Flexible networking: Support 4 channels of RS485, 1 channel of Ethernet communication
Multi-device access: Support inverter, electricity meter, weather station equipment access
(standard modbus)
Support Protocol: RS485: support modbus-RTU / Ethernet: support modbus-TCP, 104
3.2 Application Scenarios Introduction
Application scenarios of data logger
PV
PV
Solis inverter
Solis inverter
Third party platform
Router
Solis Cloud
PV Plant Digitial
Management System
Logger
Meter
Meteorograph
DC Rs485
Ethernet Internet Communication

.4.
3.3 Appearance
3.4 Power Wiring Diagram
3. Product Description
DIN-Rail Wall Mount
PE -+
COM Logger

.5.
3.5 Communication Terminal Description
Danger:
Please strictly follow the above example for wiring.
3. Product Description
24V power supply
AC:85-264V
DC:120-370V
110
5.08mm 1*10P Terminals
COM Logger

3. Product Description
NO.definition NO.definition
WARNING:
Follow the wire markings for wiring.
3.6 Indicator Light Description
S3-Logger
F1
F2
Color
Green
Green
Green
Green
Status
ON
OFF
ON/Blink
OFF
Blink
Function
Always on after power on,the power supply is normal
Power OFF
System running indicator,on/flashing is normal
Unused
Module communication status,flashing irregularly
10
9
8
7
Port 3 RS-485_A
Port 3 RS-485_B
Port 4 RS-485_A
Port 4 RS-485_B
Port 1 RS-485_A
Port 1 RS-485_B
Port 2 RS-485_A
Port2 RS-485_A
GND GND
1
2
3
4
5
6
Model
Light
PWR
RUN
.6.

4. Installation Process
5.1
5.2
6
7
Equipment disassembly
and inspection
Mechanical installation
Electrical Installation
Software configuration
Data check 7
NO.
1
2
3
4
5
Process Reference Chapter
1
2
3
4
5
Equipment
disassembly and
inspection
Mechanical
installation
Electrical
Installation
Software
configuration
Data check
.7.

.8.
5.1 Equipment Disassembly
Check that the delivery is complete and undamaged according to the packing list inside the package.
5. Mechanical Installation
1
1
1
1
Port 3 RS-485_A
Port 3 RS-485_B
With 2*120 ohm
terminating resistors
S3-Logger Datalogger
Power terminal
Serial communication
terminal
Power Supply
DIN-Rail
Name Num
1
Comment
5.2 Device Installation
It can be installed on the wall, desktop or rail according to the actual situation of the site
Wall and desktop installation
DIN-Rail Wall Mount
10cm
NO.
1
2
3
4
5
COM Logger

1. Choose a suitable place (wall, metal surface, desktop);
2. Use a marker to mark the drilling position;
3. Use an electric drill/impact drill to make holes at the marked locations;
4. Fastening with expansion screws (wall) or with nuts (metal surface)
Danger:
Please avoid other wires in the wall when drilling to avoid casualties.
Rail installation
1. Fix the guide rail in a suitable position
2. S3-Logger is tilted at a certain angle, so that the upper clip fits into the guide rail
3. Push the lower part of S3-Logger and snap it into the guide rail
Warning:
Please observe the surrounding environment during installation to avoid hand scratches.
Power supply installation
The power supply only supports rail installation. For installation steps, please refer to the
S3-Logger rail installation steps.
5. Mechanical Installation
.9.

6. Electrical Connections
Power supply installation steps
1. Use a 2.5mm² wire, strip the insulation for 8-10mm.
2. The +V and -V terminals of the power supply are respectively connected to the V+ and
V- terminals of the S3-Logger device.
Danger:
Please be sure to check the corresponding terminal carefully when wiring, so as to avoid
injury to personnel and equipment.
RS485 connection
.10.
24V power supply
AC:85-264V
DC:120-370V
110
5.08mm 1*10P Terminals
COM Logger

6. Electrical Connections
1. Use 1~1.5mm² twisted pair with shielding layer
2. Strip the protective layer of the communication cable by about 20mm, and strip the insulation
layer of the wires by about 10mm
3. Connect the stripped wires to the RS485 port of the S3-Logger device
4. If multiple inverters need to be monitored on site, daisy-chain cables can be used for the
inverters. Each serial port of S3-Logger can connect 15 inverters.
Note:
When wiring, RS485A is connected to the A port of the S3-Logger device, and RS485B is
connected to the B port of the S3-Logger device.
.11.
NO.definition NO.definition
10
9
8
7
Port 3 RS-485_A
Port 3 RS-485_B
Port 4 RS-485_A
Port 4 RS-485_B
Port 1 RS-485_A
Port 1 RS-485_B
Port 2 RS-485_A
Port2 RS-485_A
GND GND
1
2
3
4
5
6

The product adopts WEB configuration, it is recommended to use browser chrome version 100
or above, and the resolution of computer is recommended to be 1920*1080. If there is a firewall
on site, please let the firewall allow the following IP and port, so that the data collected can be
effectively uploaded.
IP: Allocation according to firewall policy, Logger for adaptation.
Solis cloud platform: port 1883.
IEC104 protocol: 2404-2405 ports.
Remote maintenance ports: 1723, 1777 ports.
7. Configuration
7.1 Network Configuration
.12.
7.2 Software Configuration
1.Modify the computer IP, and keep the computer and Logger datalogger IP in the same network
segment, and use the network cable to connect the computer and Logger device.

7. Configuration
.13.
2. Enter 192.168.1.254:1323 in the URL bar of the browser.
Account: admin; Password: 123456

7. Configuration
.14.
3. Configure the RS485 interface in "Interface config", connect COM1 and COM2 to the inverter
and EPM, COM3 to the weather station, and COM4 to the electric meter. (If the list of weather
stations and electric meters cannot match the actual application on site. Please feedback the
equipment model and communication protocol to the local technical support, and we will update it
according to the site).
Select COM1, click "Add Device" to add the number of inverters, just select the inverter and
inverter device address. If you want to delete redundant configuration, turn off "YES or NO" to
delete redundant configuration. Similar to weather stations and electricity meters. After the
configuration is complete, click "Reboot" to restart and take effect.
4."Device data" can view the real-time data of the connected device. At the same time, the
inverter can be remotely adjusted and controlled by "Control and Telecontrol".

7. Configuration
.15.
5.‘To configure’ allows you to import the configuration file directly. If other brands of weather
stations or electricity meters are used on site, please send the communication protocol of the
equipment to the local technical support. After we complete the configuration, you only need to
import the configuration file and restart it to take effect. "Plug-in unit" is an option to update the
software driver, similar to the operation to configure.
6. When the COM3 weather station or COM4 meter Device address is not the default value of
"1-3", click the "Device data" list, select the corresponding COM port, select "Telecontrol" to
manually set the device address required on site in "Point value", and click "edit".

7. Configuration
7. “Forwarding service” allows you to set forwarding information.
Supports IEC104, Modbus-TCP, and MQTT forwarding
Protocol Communication parameter
Same as the device network port
2404
Same as the device network port
502
IP address, subnet mask, and gateway
Port
Port
Function code
Register start address
Function code
Register start address
Data type
Byte order
Function code
Register start address
Data type
Byte order
02
03
32-bit short floating point
HH HL LH LL
04
32-bit short floating point
HH HL LH LL
IEC104
IP address, subnet mask, and gateway
Tele
signaling
Telemetering
Tele control
Function code
Register start address
Function code
Data type
Byte order
05
06 or 10
16 bit signed integer
HL
Control
Tele
control
MQTT
ON
OFF
Upload to Solis Cloud
Do not upload to Solis Cloud
.16.

7. Configuration
.17.
8. "Account password" allows you to modify the login password.
Table of contents
Other SOLIS Data Logger manuals
Popular Data Logger manuals by other brands

NRG Systems
NRG Systems SymphoniePLUS3 user manual

Seametrics
Seametrics DL76 instructions

MadgeTech
MadgeTech Shock101-5 Product Information Card

sauermann
sauermann KT 120 user manual

Huawei
Huawei SmartLogger3000 quick guide

IRROMETER
IRROMETER WaterGraph Data Shuttle Installation and operating instructions