Sony LMD-X310MD User manual

4-548-214-15(1)
LCD Monitor
Instructions for Use
Before operating the unit, please read this manual thoroughly
and retain it for future reference.
LMD-X310MD
LMD-X550MD
© 2015 Sony Corporation
2020-02

2
Indications for Use/Intended Use
The LCD Monitor is intended to provide 4K 2D color
video displays of images from endoscopic/laparoscopic
camera systems and other compatible medical imaging
systems.
The LCD Monitor is a widescreen, high-definition,
medical grade monitor for real-time use during minimally
invasive surgical procedures and is suitable for use in
hospital operating rooms, surgical centers, clinics,
doctors’ offices and similar medical environments.
Notes
• This equipment is for medical professionals.
• This equipment is intended for use in medical
environments, such as clinics, examination rooms, and
operating rooms.
• Essential performance is to display image and operate
functions normally.
To reduce the risk of fire or electric shock, do not
expose this equipment to rain or moisture.
To avoid electrical shock, do not open the
cabinet. Refer servicing to qualified personnel
only.
No modification of this equipment is allowed.
WARNING
Symbols on the product
Safety sign (LMD-X310MD only)
Follow the warnings in the instructions for use
for parts of the unit on which this symbol
appears.
NOTE Background color: Blue
Symbol: White
Consult the instructions for use
Follow the directions in the instructions for
use for parts of the unit on which this symbol
appears.
This symbol indicates the manufacturer, and
appears next to the manufacturer’s name and
address.
This symbol indicates the EU Importer, and
appears next to the EU Importer’s name and
address.
This symbol indicates the European
Community representative, and appears next
to the European Community representative’s
name and address.
This symbol indicates the medical device in
the European Community.
This symbol indicates the date of
manufacture.
This symbol indicates the serial number.
This symbol indicates the version of the
accompanying document.
This symbol indicates the Unique Device
Identifier (UDI), and appears next to the bar
code representation of the Unique Device
Identification.
This symbol indicates the equipotential
terminal which brings the various parts of a
system to the same potential.
Storage and transport temperature
This symbol indicates the acceptable
temperature range for storage and transport
environments.
Storage and transport humidity
This symbol indicates the acceptable humidity
range for storage and transport environments.
Storage and transport pressure
This symbol indicates the acceptable
atmospheric pressure range for storage and
transport environments.
Parts on the unit with this symbol have a risk
of electric shock. Follow the cautions in the
instructions for use.

3
For customers in the U.S.A.
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when
the equipment is operated in a commercial environment.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause
harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause
harmful interference in which case the user will be
required to correct the interference at his own expense.
You are cautioned that any changes or modifications not
expressly approved in this manual could void your
authority to operate this equipment.
All interface cables used to connect peripherals must be
shielded in order to comply with the limits for a digital
device pursuant to Subpart B of part 15 of FCC Rules.
For customers in the U.S.A.
Caution
Federal law (United States of America) restricts this
device to sale by or on the order of a licensed healthcare
practitioner.
For customers in Canada
This unit has been certified according to Standard CAN/
CSA-C22.2 No. 60601-1.
Important safeguards and notices for use
in the medical environments
1. All devices connected to the unit must be certified or
compliant according to IEC 60601-1, IEC 60950-1,
and IEC 60065 standards and other IEC/ISO
standards applicable to the devices.
2. Furthermore, the system as a whole must comply with
IEC 60601-1 standards. All peripheral devices
connected to the signal input/output sections of the
unit constitute the medical-use system, and therefore,
the user is responsible for ensuring that the system as
a whole complies with IEC 60601-1 standards. If in
doubt, consult qualified Sony service personnel.
3. Connecting the unit to other devices may increase the
leakage current.
4. For all peripheral devices connected to the unit that
operate on commercial power supplies and do not
comply with IEC 60601-1 standards, incorporate an
isolation transformer that complies with IEC 60601-1
standards and connect to the commercial power
supply via the transformer.
5. The unit generates, uses, and may radiate radio
frequency energy. If it is not installed and used in
accordance with the instruction manual, it may cause
interference on other devices. If the unit causes
interference (which can be determined by
disconnecting the power cord from the unit), try the
following.
– Relocate the unit with respect to the affected
devices.
– Connect the unit and the affected devices to
different branch circuits.
For more information, consult qualified Sony service
personnel.
(Applicable standard: IEC 60601-1-2)

4
Important EMC notices for use in medical environments
• The LMD-X310MD/X550MD needs special precautions regarding EMC and needs to be installed and put into service
according to the EMC information provided in the instructions for use.
• The LMD-X310MD/X550MD is intended for use in a professional healthcare facility environment.
• Portable and mobile RF communications equipment, such as cellular phones, can affect the LMD-X310MD/X550MD.
Warning
• Portable RF communications equipment should be used no closer than 30 cm (12 inches) to any part of the LMD-
X310MD/X550MD. Otherwise, degradation of the performance of this equipment could result.
• If the LMD-X310MD/X550MD will be used adjacent to or stacked with other equipment, normal operation of the LMD-
X310MD/X550MD under such configurations should be verified via observation.
• The use of accessories and cables other than those specified, with the exception of replacement parts sold by Sony
Corporation, may result in increased emissions or decreased immunity of the LMD-X310MD/X550MD.
Guidance and manufacturer’s declaration – electromagnetic emissions
The LMD-X310MD/X550MD is intended for use in the electromagnetic environment specified below. The customer or
the user of the LMD-X310MD/X550MD should assure that it is used in such an environment.
Emission test Compliance Electromagnetic environment – guidance
RF emissions
CISPR 11 Group 1
The LMD-X310MD/X550MD uses RF energy only for its
internal function. Therefore, its RF emissions are very low
and are not likely to cause any interference in nearby
electronic equipment.
RF emissions
CISPR 11
Class B
The LMD-X310MD/X550MD is suitable for use in all
establishments, including domestic establishments and
those directly connected to the public low-voltage power
supply network that supplies buildings used for domestic
purposes.
Harmonic emissions
IEC 61000-3-2
Not applicable
(LMD-X310MD)
Class D
(LMD-X550MD)
Voltage fluctuations/
flicker emissions
IEC 61000-3-3
Not applicable
(LMD-X310MD)
Complies
(LMD-X550MD)

5
Guidance and manufacturer’s declaration – electromagnetic immunity
The LMD-X310MD/X550MD is intended for use in the electromagnetic environment specified below. The customer or
the user of the LMD-X310MD/X550MD should assure that it is used in such an environment.
Immunity test IEC 60601
test level
Compliance level Electromagnetic environment – guidance
LMD-X310MD LMD-X550MD
Electrostatic
discharge (ESD)
±8 kV contact ±8 kV contact ±8 kV contact Floors should be wood, concrete or ceramic
tile. If floors are covered with synthetic
material, a relative humidity of at least 30% is
recommended.
IEC 61000-4-2 ±15 kV air ±15 kV air ±15 kV air
Electrical fast
transient/burst
±2 kV for power
supply lines
±2 kV for power
supply lines
Mains power quality should be that of a
typical commercial or hospital environment.
(LMD-X550MD)
IEC 61000-4-4 ±1 kV for input/
output lines
±1 kV for input/
output lines
±1 kV for input/
output lines
Surge ±1 kV line(s) to
line(s)
Not applicable ±1 kV
differential
mode
Mains power quality should be that of a
typical commercial or hospital environment.
(LMD-X550MD)
IEC 61000-4-5 ±2 kV line(s) to
earth
±2 kV common
mode
Voltage dips,
short
interruptions
and voltage
variations on
power supply
input lines
IEC 61000-4-11
0% UT
(100% dip in
UT)
for 0.5/1 cycles a
40% UT
(60% dip in UT)
for 5 cycles
70% UT
(30% dip in UT)
for 25/30
cycles a
(for 0.5 sec)
0% UT
(100% dip in
UT)
for 250/300
cycles a
(for 5 sec)
Not applicable 0% UT
(100% dip in
UT)
for 0.5/1 cycles a
40% UT
(60% dip in UT)
for 5 cycles
70% UT
(30% dip in UT)
for 25/30
cycles a
(for 0.5 sec)
0% UT
(100% dip in
UT)
for 250/300
cycles a
(for 5 sec)
Mains power quality should be that of a
typical commercial or hospital environment.
If the user of the LMD-X310MD/X550MD
requires continued operation during power
mains interruptions, it is recommended that
the LMD-X310MD/X550MD be powered
from an uninterruptible power supply or a
battery.
Powerfrequency
(50/60 Hz)
magnetic field
IEC 61000-4-8
30 A/m 30 A/m 30 A/m Power frequency magnetic fields should be at
levels characteristic of a typical location in a
typical commercial or hospital environment.
NOTE: UTis the a.c. mains voltage prior to application of the test level.
a For example, 10/12 means 10 cycles at 50 Hz or 12 cycles at 60 Hz.

6
Guidance and manufacturer’s declaration – electromagnetic immunity
The LMD-X310MD/X550MD is intended for use in the electromagnetic environment specified below. The customer or
the user of the LMD-X310MD/X550MD should assure that it is used in such an environment.
Immunity test IEC 60601
test level Compliance level Electromagnetic environment – guidance
Portable and mobile RF communications equipment
should be used no closer to any part of the LMD-
X310MD/X550MD, including cables, than the
recommended separation distance calculated from the
equation appliance to the frequency of the transmitter.
Recommended separation distance
Conducted RF
IEC 61000-4-6
3 Vrms
150 kHz to 80 MHz
outside ISM bands c
3 Vrms d= 1.2 √P
6 Vrms
150 kHz to 80 MHz
in ISM bands c
6 Vrms
Radiated RF 3 V/m 3 V/m IEC 60601-1-2: 2007
d= 1.2 √P80 MHz to 800 MHz
d= 2.3 √P800 MHz to 2.5 GHz
IEC 60601-1-2: 2014
d= 2.0 √P80 MHz to 2.7 GHz
Where Pis the maximum output power rating of the
transmitter in watts (W) according to the transmitter
manufacturer and dis the recommended separation
distance in meters (m).
Field strengths from fixed RF transmitters, as
determined by an electromagnetic site survey, ashould
be less than the compliance level in each frequency
range. b
Interference may occur in the vicinity of equipment
marked with following symbol:
IEC 61000-4-3 80 MHz to 2.7 GHz
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.

7
a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy.
To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be
considered. If the measured field strength in the location in which the LMD-X310MD/X550MD is used exceeds the
applicable RF compliance level above, the LMD-X310MD/X550MD should be observed to verify normal operation.
If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the
LMD-X310MD/X550MD.
b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
c The ISM (industrial, scientific and medical) bands between 150 kHz and 80 MHz are 6.765 MHz to 6.795 MHz;
13.553 MHz to 13.567 MHz; 26.957 MHz to 27.283 MHz; and 40.66 MHz to 40.70 MHz.
Recommended separation distances between portable and mobile RF communications equipment
and the LMD-X310MD/X550MD
The LMD-X310MD/X550MD is intended for use in an electromagnetic environment in which radiated RF disturbances
are controlled. The customer or the user of the LMD-X310MD/X550MD can help prevent electromagnetic interference
by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the
LMD-X310MD/X550MD as recommended below, according to the maximum output power of the communications
equipment.
Rated maximum output
power of transmitter
W
Separation distance according to frequency of transmitter
m
IEC 60601-1-2 : 2007 IEC 60601-1-2 : 2014
150 kHz to
80 MHz
d= 1.2 √P
80 MHz to
800 MHz
d= 1.2 √P
800 MHz to
2.5 GHz
d= 2.3 √P
150 kHz to
80 MHz
d= 1.2 √P
80 MHz to
2.7 GHz
d= 2.0 √P
0.01 0.12 0.12 0.23 0.12 0.20
0.1 0.380.380.730.380.63
1 1.2 1.2 2.3 1.2 2.0
10 3.8 3.8 7.3 3.8 6.3
100 12 12 23 12 20
For transmitters rated a maximum output power not listed above, the recommended separation distance din meters (m)
can be estimated using the equation applicable to the frequency of the transmitter, where Pis the maximum output
power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.

8
Caution
When you dispose of the unit or accessories, you must
obey the laws in the relative area or country and the
regulations in the relative hospital regarding
environmental pollution.
WARNING
The apparatus shall not be exposed to dripping or
splashing. No objects filled with liquids, such as vases,
shall be placed on the apparatus.
WARNING
To prevent injury, if mounting the unit using a mounting
arm, wall fixture, or other mounting device prepared by
the customer, mount the unit securely as described in the
instruction manual provided with the mounting device.
When fixing the unit, use more than 4 of the supplied
screws for the VESA mount or specified screws.
Fasten the screws to the hole positions firmly and
symmetrically to the upper and lower, left and right
positions towards the center of the monitor.
Check beforehand that the mounting device used has
sufficient strength to support the added weight of the unit.
Check yearly that the mounting device is securely
attached.
Guidance and manufacturer’s declaration – electromagnetic immunity
The LMD-X310MD/X550MD is intended for use in an electromagnetic environment in which radiated RF disturbances
are controlled. Portable RF communications equipment should be used no closer than 30 cm (12 inches) to any part of
the LMD-X310MD/X550MD. Otherwise, degradation of the performance of this equipment could result.
Immunity test Band aService aModulation IEC 60601
test level Compliance level
Proximity fields
from RF wireless
communications
equipment
IEC 61000-4-3
380 – 390 MHz TETRA 400 Pulse modulation
18 Hz 27 V/m 27 V/m
430 – 470 MHz GMRS 460
FRS 460
FM
±5 kHz deviation
1 kHz sine
28 V/m 28 V/m
704 – 787 MHz LTE Band 13, 17 Pulse modulation
217 Hz 9 V/m 9 V/m
800 – 960 MHz
GSM 800/900
TETRA 800
iDEN 820
CDMA 850
LTE Band 5
Pulse modulation
18 Hz 28 V/m 28 V/m
1,700 – 1,990 MHz
GSM 1800
CDMA 1900
GSM 1900
DECT
LTE Band 1, 3, 4,
25
UMTS
Pulse modulation
217 Hz 28 V/m 28 V/m
2,400 – 2,570 MHz
Bluetooth
WLAN
802. 11 b/g/n
RFID 2450
LTE Band 7
Pulse modulation
217 Hz 28 V/m 28 V/m
5,100 – 5,800 MHz WLAN 802. 11 a/n Pulse modulation
217 Hz 9 V/m 9 V/m
NOTE: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
a For some services, only the uplink frequencies are included.

9
Caution
When installing, ensure the following space around the
periphery of the unit, taking ventilation and servicing into
consideration.
– Rear side: 4 cm (1 5/8in.) or more
– Left/Right sides: 10 cm (4 in.) or more
– Bottom side: 6 cm (2 3/8in.) or more
– Top side: 30 cm (11 7/8in.) or more
Consult with Sony qualified personnel for the following
types of installation location.
–Wallmount
– Floor mount (LMD-X310MD only)
Caution
Do not use the device in a MR (Magnetic Resonance)
environment.
It may cause a malfunction, fire, and unwanted
movement.
LMD-X550MD only
WARNING
To avoid the risk of electric shock, this
equipment must only be connected to a supply
mains with protective earth.
WARNING
This unit has no power switch.
To disconnect the main power, unplug the power plug.
When installing the unit, incorporate a readily accessible
disconnect device in the fixed wiring, or connect the
power plug to an easily accessible socket-outlet near the
unit.
Do not position the ME equipment where it is difficult to
unplug the power plug.
If a fault should occur during operation of the unit,
operate the disconnect device to switch the power supply
off, or disconnect the power plug.
Warning on power connections
Use a proper power cord for your local power supply.
1. Use the approved Power Cord (3-core mains lead) /
Appliance Connector / Plug with earthing-contacts
that conforms to the safety regulations of each country
if applicable.
2. Use the Power Cord (3-core mains lead) / Appliance
Connector / Plug conforming to the proper ratings
(Voltage, Ampere).
If you have questions on the use of the above Power Cord /
Appliance Connector / Plug, please consult a qualified
service personnel.
Warning on power connections for
medical use
Customers in the U.S.A. and Canada should use the
following type of power cord.
Customers in other countries or regions should use the
power cord prescribed by their country or region.
* Note: Grounding reliability can only be achieved when
the equipment is connected to an equivalent receptacle
marked “Hospital Only” or “Hospital Grade”.
Caution
• This unit is heavy. Make sure to unpack and move the
unit with two or more people.
• Firmly grip the bottom of this unit as shown below.
U.S.A. and Canada
Plug type HOSPITAL GRADE*
Cord type Min. Type SJT
Min. 18 AWG
Minimum rating for plug
and appliance couplers
10 A / 125 V
Safety approval UL Listed and CSA

10
Disposal of Old Electrical & Electronic Equipment
(Applicable in Republic of India)
This symbol indicates that this product and its
components, consumables, parts or spares thereof shall
not be treated as household waste and may not be
dropped in garbage bins. Product owners are advised to
deposit their product at the nearest collection point for
the recycling of electrical and electronic equipment.
Your co-operation shall facilitate proper disposal & help
prevent potential negative consequences/hazards to the
environment and human health, which could otherwise
be caused by inappropriate waste disposal including
improper handling, accidental breakage, damage and/ or
improper recycling of e-waste. The recycling of materials
will help to conserve natural resources. For more
detailed information about recycling of this product,
please contact your local civic office, your household
waste disposal service provider or the store where you
made the purchase. You may contact our company’s toll
free number in India for assistance.
Toll Free: 1800-103-7799
Visit: www.sony.co.in for product recycling
Reduction in the Use of Hazardous Substances in
Electrical & Electronic Equipment (Applicable in
Republic of India)
This product and its components, consumables, parts or
spares comply with the hazardous substances restriction
of India’s E-Waste (Management) Rules. The maximum
allowable concentrations of the restricted substances are
0.1% by weight in homogenous materials for Lead,
Mercury, Hexavalent Chromium, Polybrominated
Biphenyls (PBB) and Polybrominated Diphenyl Ethers
(PBDE), and 0.01% by weight in homogenous materials
for Cadmium, except for the exemptions specified in
Schedule II of the aforesaid Rules.
For the customers in the U.S.A.
SONY LIMITED WARRANTY - Please visit http://
www.sony.com/psa/warranty for important
information and complete terms and conditions of
Sony’s limited warranty applicable to this product.
For the customers in Canada
SONY LIMITED WARRANTY - Please visit http://
www.sonybiz.ca/pro/lang/en/ca/article/resources-
warranty for important information and complete
terms and conditions of Sony’s limited warranty
applicable to this product.
For the customers in Europe
Sony Professional Solutions Europe - Standard
Warranty and Exceptions on Standard Warranty.
Please visit https://pro.sony/en_GB/support-
services/warranty/support-professional-solutions-
europe-standard-product-warranty for important
information and complete terms and conditions.
For the customers in Korea
SONY LIMITED WARRANTY - Please visit http://
bpeng.sony.co.kr/handler/BPAS-Start for important
information and complete terms and conditions of
Sony’s limited warranty applicable to this product.

Table of Contents 11
Table of Contents
Precaution ..................................................... 12
On Safety .................................................................12
On Installation .......................................................12
Precautions for using this unit safely ..................12
Precautions for connecting this unit with other
medical devices ....................................................12
To prolong the life of the unit ..............................12
Cautions for RESPONSIBLE ORGANIZATION
when connecting this equipment to IT-
NETWORK ..........................................................12
On simultaneous use with an electrosurgical
knife, etc. ...............................................................13
Recommendation to Use more than One
Unit ........................................................................13
LCD image display .................................................13
About the LCD Display Panel ..............................13
About the Screen Protect Panel ...........................13
On a Long Period of Use .......................................13
On Burn-in .............................................................13
On Fan Error ..........................................................14
On Temperature Error ..........................................14
On Moisture Condensation ..................................14
On Security .............................................................14
On Cleaning ...........................................................14
On Repacking .........................................................14
Disposal of the Unit ...............................................14
Features ......................................................... 15
Location and Function of Parts and
Controls ........................................................ 17
Front Panel.............................................................. 17
Input Signals and Adjustable/Setting Items ....... 18
Rear/Bottom Panel ................................................ 19
Connecting the AC Power Cord .................. 21
LMD-X310MD .......................................................21
LMD-X550MD .......................................................22
Removing the Connector Cover ................... 23
Configuration Example: 4K Surgical
Endoscope ..................................................... 24
Initial Setting ................................................ 24
Using the Menu ............................................ 26
Adjustment Using the Menus ...................... 27
Items ........................................................................27
Adjusting and changing the settings ...................28
Color Tone Adjustment menu .......................28
Screen Control menu ......................................29
PIP / POP menu ...............................................29
Input Configuration menu .............................29
System Configuration menu ..........................30
Initial Setup menu ............................................31
Preset menu ......................................................31
Troubleshooting ........................................... 32
Error Messages ............................................. 32
Specifications ................................................ 33
LMD-X310MD ...................................................... 33
LMD-X550MD ...................................................... 33
Dimensions ................................................... 40
LMD-X310MD ...................................................... 40
LMD-X550MD ...................................................... 40
LMD-X310MD/X550MD .................................... 41
The terms HDMI and HDMI High-Definition
Multimedia Interface, and the HDMI Logo are
trademarks or registered trademarks of HDMI
Licensing Administrator, Inc. in the United States and
other countries.

Precaution
12
Precaution
On Safety
LMD-X310MD is a DC powered device. Use with the
supplied AC adaptor (AC-300MD).
LMD-X550MD is an AC powered device.
Operate the unit on 100-240 V AC only.
The nameplate indicating operating voltage, etc. is
located on the AC adaptor.
Should any solid object or liquid fall into the cabinet,
unplug the unit and have it checked by qualified
personnel before operating it any further.
Unplug the unit from the wall outlet if it is not to be
used for several days or more.
To disconnect the AC power cord, pull it out by
grasping the plug. Never pull the cord itself.
The socket-outlet shall be installed near the
equipment and shall be easily accessible.
On Installation
Prevent internal heat build-up allowing adequate air
circulation.
Do not place the unit on surfaces (rugs, blankets, etc.)
or near materials (curtains, draperies) that may block
the ventilation holes.
Do not install the unit near heat sources such as
radiators or air ducts, or in a place subject to direct
sunlight, excessive dust, mechanical vibration or
shock.
Do not place the monitor near equipment which
generates magnetism, such as a transformer or high
voltage power lines.
Precautions for using this unit safely
Some people may experience discomfort (such as eye
strain, fatigue, or nausea) while watching video
images. Sony recommends that all viewers take regular
breaks while watching video images. The length and
frequency of necessary breaks will vary from person to
person. You must decide what works best.
Avoid watching the display in environments where
your head may shake, or while you are walking or
performing exercise, because there is a higher
possibility that you experience discomfort.
Precautions for connecting this unit
with other medical devices
Before you utilize this device and/or connect this
device to any other medical device, please be aware of
and abide by the following precautions:
(a) Before actually using this device for medical
practice, please check and confirm that you do not
experience any discomfort in your use that could be
disruptive or impeditive in conducting your intended
activity or medical practice.
(b) If you experience or are likely to experience such
discomfort, please refrain from using this device.
(c) Generally, discomfort (such as eye strain, fatigue,
nausea, or motion sickness) can be provoked by such
factors as quick movements or shakiness of video
picture, focal position of video pictures, distance
between objects and image capturing modules, user’s
point of gaze in video pictures, other varying
conditions of video pictures to be input to this device,
and individual user’s health conditions.
Before you utilize this unit, check if the image of the
connected medical device is displayed properly on the
screen of this unit.
To prolong the life of the unit
Turn off the power to preserve the performance when
not in use for a prolonged time.
Cautions for RESPONSIBLE
ORGANIZATION when connecting this
equipment to IT-NETWORK
– connection of the PEMS to an IT-NETWORK that
includes other equipment could result in previously
unidentified RISKS to PATIENTS, OPERATORS or
third parties;
– the RESPONSIBLE ORGANIZATION should
identify, analyze, evaluate and control these RISKS;
– subsequent changes to the IT-NETWORK could
introduce new RISKS and require additional analysis;
and
– changes to the IT-NETWORK include:
changes in the IT-NETWORK configuration;
connection of additional items to the IT-
NETWORK;
disconnecting items from the IT-NETWORK;
update of equipment connected to the IT-
NETWORK; and
upgrade of equipment connected to the IT-
NETWORK.

Precaution 13
On simultaneous use with an
electrosurgical knife, etc.
If this unit is used together with an electrosurgical knife,
etc., the picture may be disturbed, warped or otherwise
abnormal as a result of strong radio waves or voltages
from the device. This is not a malfunction.
When you use this unit simultaneously with a device
from which strong radio waves or voltages are emitted,
confirm the effect of this before using such devices, and
install this unit in a way that minimizes the effect of
radio wave interference.
Recommendation to Use more than
One Unit
As problems can occasionally occur for the monitor,
when the monitor is used for safety control of personnel,
assets or stable picture, or for emergencies, we strongly
recommend you use more than one unit or prepare a
spare unit.
LCD image display
Due the physical characteristics of LCD panels, there
may be a decrease in brightness or change in color
temperature over a long period of use. These problems
are not a malfunction.
In addition, these occurrences will not affect recorded
data.
About the LCD Display Panel
The LCD panel fitted to this unit is manufactured with
high precision technology, giving a functioning pixel
ratio of at least 99.99%. Thus a very small proportion
of pixels may be “stuck”, either always off (black),
always on (red, green, or blue), or flashing. In addition,
over a long period of use, because of the physical
characteristics of the liquid crystal display, such
“stuck” pixels may appear spontaneously. These
problems are not a malfunction.
Do not leave the LCD screen facing the sun as it can
damage the LCD screen. Take care when you place the
unit by a window.
Do not push or scratch the LCD screen. Do not place
a heavy object on the LCD screen. This may cause the
screen to lose uniformity.
If the unit is used in a cold place, a residual image may
appear on the screen. This is not a malfunction. When
the monitor becomes warm, the screen returns to
normal.
The screen and the cabinet become warm during
operation. This is not a malfunction.
About the Screen Protect Panel
The screen protect panel is made of toughened glass, but
there is a possibility that it may crack. Handle with care.
Avoid strong impact, such as dropping from a high
place.
Do not damage the panel with a sharp object. The glass
may crack due to the damage.
On a Long Period of Use
Due to the characteristics of LCD panel, displaying static
images for extended periods, or using the unit repeatedly
in a high temperature/high humidity environments may
cause image smearing, burn-in, areas of which
brightness is permanently changed, lines, or a decrease
in overall brightness.
In particular, continued display of an image smaller than
the monitor screen, such as in a different aspect ratio,
may shorten the life of the unit.
Avoid displaying a still image for an extended period, or
using the unit repeatedly in a high temperature/high
humidity environment such an airtight room, or around
the outlet of an air conditioner.
To prevent any of the above issues, we recommend
reducing brightness slightly, and to turn off the power
whenever the unit is not in use.
On Burn-in
For LCD panel, permanent burn-in may occur if still
images are displayed in the same position on the screen
continuously, or repeatedly over extended periods.
Images that may cause burn-in
Masked images with aspect ratios other than 17:9 for
the LMD-X310MD and 16:9 for the LMD-X550MD
Color bars or images that remain static for a long time
Character or message displays that indicate settings or
the operating state
To reduce the risk of burn-in
Turn off the character displays
Press the MENU button to turn off the character
displays. To turn off the character displays of the
connected equipment, operate the connected
equipment accordingly. For details, refer to the
operation manual of the connected equipment.
Turn off the power when not in use

Precaution
14
Turn off the power if the monitor is not to be used for
a prolonged period of time.
On Fan Error
The fan for cooling the unit is built in. When the fan
error indication appears on the screen, turn off the
power and contact an authorized Sony dealer.
On Temperature Error
When this unit is used in a high temperature
environment and the internal temperature rises, an error
is displayed on the screen. When the error is displayed,
contact an authorized Sony dealer.
On Moisture Condensation
If the unit is suddenly taken from a cold to a warm
location, or if ambient temperature suddenly rises,
moisture may form on the outer surface of the unit and/
or inside of the unit. This is known as condensation. If
condensation occurs, turn off the unit and wait until the
condensation clears before operating the unit. Operating
the unit while condensation is present may damage the
unit.
On Security
SONY WILL NOT BE LIABLE FOR DAMAGES OF
ANY KIND RESULTING FROM A FAILURE TO
IMPLEMENT PROPER SECURITY MEASURES ON
TRANSMISSION DEVICES, UNAVOIDABLE DATA
LEAKS RESULTING FROM TRANSMISSION
SPECIFICATIONS, OR SECURITY PROBLEMS OF
ANY KIND.
Depending on the operating environment,
unauthorized third parties on the network may be able
to access the unit. When connecting the unit to the
network, be sure to confirm that the network is
protected securely.
This unit is equipped with a maintenance function
performed via a network. Maintenance may be
performed with your consent.
On Cleaning
Before cleaning
Be sure to disconnect the AC power cord from the AC
outlet.
On cleaning the monitor
A material that withstands disinfection is used for the
front protection plate of the medical use LCD monitor.
The protection plate surface is specially treated to reduce
reflection of light. When solvents such as benzene or
thinner, or acid, alkaline or abrasive detergent, or
chemical cleaning cloth are used for the protection plate
surface/monitor surface, the performance of the
monitor may be impaired or the finish of the surface may
be damaged. Take care with respect to the following:
Clean the protection plate surface/monitor surface
with a 50 to 70 v/v% concentration of isopropyl
alcohol or a 76.9 to 81.4 v/v% concentration of ethanol
using a swab method. Wipe the protection plate
surface gently (wipe using less than 1 N force).
Stubborn stains may be removed with a soft cloth such
as a cleaning cloth lightly dampened with mild
detergent solution using a swab method and then
clean using the above chemical solution.
Never use solvents such as benzene or thinner, or acid,
alkaline or abrasive detergent, or chemical cleaning
cloth for cleaning or disinfection, as they will damage
the protection plate surface/monitor surface.
Do not use unnecessary force to rub the protection
plate surface/monitor surface with a stained cloth. The
protection plate surface/monitor surface may be
scratched.
Do not keep the protection plate surface/monitor
surface in contact with a rubber or vinyl resin product
for a long period of time. The finish of the surface may
deteriorate.
On Repacking
Do not throw away the carton and packing materials.
They make an ideal container which to transport the
unit.
If you have any questions about this unit, contact your
authorized Sony dealer.
Disposal of the Unit
Do not dispose of the unit with general waste.
Do not include the monitor with household waste.
About this manual
The instructions in this manual are for the following
models:
LMD-X310MD
LMD-X550MD
The illustration of LMD-X310MD is used for the
explanations. Any differences in specifications are
clearly indicated in the text.

Features 15
Features
The LCD Monitor is to provide color video displays of
images from medical imaging systems on LCD (liquid
crystal display) panel.
Liquid crystal and color filters are laid on the front of flat
light source (backlight) on the LCD panel. And then, the
LCD panel displays images by controlling the aperture of
the liquid crystal according to input signals.
Compliance with medical safety standards
in U.S.A., Canada and Europe
IEC 60601-1 and product safety standards in the U.S.A.,
Canada and Europe have been obtained for this monitor.
The monitor is designed for use in the medical treatment
field, with the sheet switch, screen protect panel, etc.
High brightness/high-resolution 4K panel
A 4K high-resolution panel and high brightness/ultra-
wide field of view technology enables you to use the
monitor under various lighting conditions and in
numerous ways (installing on the wall, using several
monitors to view an image, etc.). Because a color filter
with wide-color reproduction and LCD materials with
high response speed are used, the motion picture of the
video signal is displayed more clearly.
A.I.M.E. (Advanced Image Multiple
Enhancer) function
There are two modes in the A.I.M.E. function – the
“Structure Enhancement mode” and “Color
Enhancement mode.”
Users can select four levels for the Structure
Enhancement mode and eight levels for the Color
Enhancement mode, depending on their preference.
By utilizing the A.I.M.E. function, users can expect the
following effects on displayed images.
Color Enhancement Function
This function clarifies color tone differences between
objects.
Structure Enhancement Function
This function improves recognition of the outline of
objects. Visibility becomes clear making it easy to see
objects.
The A.I.M.E. Color Enhancement Function emphasizes
the contrast of R, G, B signals automatically but does not
allow users to select a specific color.
Users can only select the degree of contrast, which
increases from levels C1 (minimum) to C8 (maximum).
The A.I.M.E. Structure Enhancement Function
emphasizes the outline and edges of objects.
Users can select the degree of the structure enhancement
level, which increases from levels S1 (minimum) to S4
(maximum).
The image may seem blurred by applying the A.I.M.E.
Color Enhancement Function.
The blur can be compensated for by using the A.I.M.E.
Structure Function at the same time.
Users can select the degree of the structure enhancement
from levels S1 (minimum) to S4 (maximum) for this
purpose according to their preference.
A.I.M.E. is a registered trademark of Sony Corporation.
A.I.M.E. is an optional function for enhancing the color
or structure of the displayed image.
Like the other settings of the monitor, users must adjust
or deactivate A.I.M.E. when appropriate.
Screen protect panel
OptiContrast panel
The “OptiContrast” design that fills up the air layer
between the LCD panel and screen protect panel with
bonding resin is employed. By eliminating the air layer,
this panel prevents diffused reflection and decrease in
contrast. It also prevents condensation due to rapid
temperature change.
Control panel
Assigns functions frequently used during an operation
to buttons on the front surface of the monitor. The panel
provides an user interface superior in operability
through navigation by luminescent colors and status of
the buttons.
Flat surface for better maintenance
The design allows the user to easily wipe liquids and gel
off the LCD panel and control buttons – ensuring a high
standard of disinfection and cleanliness.

Features
16
Grip that is easy to hold
The easy-to-grip ergonomic design enables the user to
make tiny adjustments simply and quickly.
Simple connector notation
All the connectors face downwards, allowing for easy
and organized cable connection.
Cover designed for attachment

Location and Function of Parts and Controls 17
Location and Function of Parts and Controls
Front Panel
Power indicator
When the power is turned on, the power indicator lights
in green.
When the protection function is activated and the
display brightness is reduced due to the rise in
temperature, it flashes in amber.
CONTROL button
Displays or clears the operating buttons on the front
panel.
Selects the items depending on the menu types.
OSD menu operation buttons
MENU button
Press to display the on-screen menu.
Press again to clear the menu.
///buttons
Press to select the items and setting values.
CUSTOM button
Turns on or off the assigned function. You can adjust the
assigned function by pressing the /buttons. (Refer to
the custom buttons of the system configuration menu on
page 31 and of the default setting on page 31.)
The following functions are assigned in the default
setting.
CUSTOM 1: Brightness
CUSTOM 2: Contrast
CUSTOM 3: Flip
A.I.M.E. button
Sets the A.I.M.E. 1) function to Off and On. When the
A.I.M.E. function is set to On, A.I.M.E. Structure and
A.I.M.E. Color can be adjusted.
1) A.I.M.E.: Enables better image reproduction and display.
2 or 3 screen display setting buttons
PIP/POP: For displaying the 2 or 3 screen display
or switching the 2 or 3 screen display mode.
SWAP: For swapping between the main display
and the sub display.
Input select buttons
PORT A: Displays the input signal assigned to
PORT A. When the input signal of PORT A is
displayed, a menu which allows you to select the input
signal to be assigned to PORT A is displayed.

Location and Function of Parts and Controls
18
PORT B: Displays the input signal assigned to
PORT B. When the input signal of PORT B is
displayed, a menu which allows you to select the input
signal to be assigned to PORT B is displayed.
(On)/ (Standby) switch
Press the side to turn the monitor on. Press the side
to switch the unit to the standby state, and the indicator
light turns off.
Input Signals and Adjustable/Setting Items
: Can be adjusted/set
×: Cannot be adjusted/set
1) Reflected on the screen only when the 4K signal is input.
2) Reflected on the screen only when the HD signal is input.
3) Reflected on the screen only when the SD signal is input.
4) The setting value can be changed but is not applied to the screen when
the PC signal is input.
Item
Input signal
SDI 1 SDI 2 DVI-D HDMI
Video PC Video PC
Gamma
Phase
Chroma
Brightness
Contrast
A.I.M.E.
Gradation Extension
Color Temperature
Mono
Sharpness H
Sharpness V
RGB Range ××
Color Space
4K Scan Size 1) ×××1) ×4)
HD Scan Size 2) 2) 2) ×4) 2) ×4)
SD Scan Size 3) 3) 3) ×4) 3) ×4)
Zoom
Flip Pattern
SD Aspect 3) 3) 3) ×4) 3) ×4)
Interface Mode ×××××

Location and Function of Parts and Controls 19
Rear/Bottom Panel
HDMI cable holder
Secures the HDMI cable (Ø7 mm or less).
HDMI input connector
Input connector for HDMI signals.
Use HighSpeed HDMI Cable with Cable Type Logo.
(Recommend Sony Cable.)
3G/HD/SD-SDI input/output connector (BNC
type)
SDI 1 (4K/HD)
connector (input)
Input connector for serial digital component signals 1)
2).
connector (output)
Signals input to the input connector are output to the
output connector.
1) Serial digital component signals are SMPTE 259M
compliant (SD)/SMPTE 292M compliant (HD)/ SMPTE
424M compliant (3G).
2) Transmission distance
3G-SDI: 70 m (approx. 230 ft) max. (When using 5C-FB
coaxial cables (Fujikura. Inc.) or equivalent.)
HD-SDI: 100 m (approx. 328 ft) max. (When using 5C-FB
coaxial cables (Fujikura. Inc.) or equivalent.)
SD-SDI: 200 m (approx. 656 ft) max. (When using 5C-2V
coaxial cables (Fujikura. Inc.) or equivalent.)
LMD-X310MD
LMD-X550MD
Close
Cable

Location and Function of Parts and Controls
20
For the HD/SD quad view setting, each connector is
compatible with the four division-images shown below.
3G/HD/SD-SDI input/output connector (BNC
type)
SDI 2 (HD)
connector (input)
Input connector for serial digital component signals 1)
2).
connector (output)
Signals input to the input connector are output to the
output connector.
1) Serial digital component signals are SMPTE 259M
compliant (SD)/SMPTE 292M compliant (HD)/ SMPTE
424M compliant (3G).
2) Transmission distance
3G-SDI: 70 m (approx. 230 ft) max. (When using 5C-FB
coaxial cables (Fujikura. Inc.) or equivalent.)
HD-SDI: 100 m (approx. 328 ft) max. (When using 5C-FB
coaxial cables (Fujikura. Inc.) or equivalent.)
SD-SDI: 200 m (approx. 656 ft) max. (When using 5C-2V
coaxial cables (Fujikura. Inc.) or equivalent.)
SERIAL REMOTE connector (RJ-45)
Connect to the network by using a 10BASE-T/100BASE-
TX LAN cable (non-shielded type of 5 or more category,
optional).
The monitor can be operated according to control
commands sent from connected external equipment.
Consult your dealer in order to utilize the function.
Caution
For safety, do not connect the connector to peripheral
device wiring that might have excessive voltage.
Follow the instructions for use for this port.
The connection speed may be affected by the network
system. This unit does not guarantee the
communication speed or quality of 10BASE-T/
100BASE-TX.
12V 1.7A output connector
Outputs 12 volts. (A connector for an option for future
use)
5V 1.6A output connector
Outputs 5 volts. (A connector for an option for future
use)
DVI-D input/output connector
connector (input)
Input DVI Rev.1.0 applicable digital signal.
connector (output)
Active through output connector of the DVI digital
signal.
Note
Signals are output when the power is on. No signal is
output when the power is off. Signals protected with
HDCP 1) cannot be output.
1) HDCP (High-bandwidth Digital Content Protection) is a
copyright protection technology using encryption
technology of digital video signals.
SERIAL REMOTE RS-232C connector (D-sub
9-pin, female)
The monitor can be operated according to control
commands sent from connected external equipment.
(DC 26 V input) connector (LMD-X310MD
only)
Connects the DC connector of the supplied AC adaptor.
Caution
Connect the DC connector to the unit, then connect the
power cord of the AC adaptor.
To remove the DC connector, remove the power cord of
the AC adaptor, then remove the DC connector.
WARNING
For the DC power supply, make sure to use the supplied
AC adaptor, AC-300MD.
If another power supply is used, there is a risk of fire or
electric shock.
(equipotential) terminal
Connects the equipotential plug.
(AC input) connector (LMD-X550MD only)
Connects the supplied AC power cord.
Caution
Do not come into contact with the terminals of the rear
panel connectors and patients at the same time.
Doing so may result in a generation of voltage that can be
harmful to patients if the unit is malfunctioning.
Always disconnect the power cord before connecting
and disconnecting connectors.
This manual suits for next models
1
Table of contents
Other Sony Monitor manuals

Sony
Sony TRINITRON CPD-4402 User manual

Sony
Sony SDM-P82 User manual

Sony
Sony LMD-2765MD User manual

Sony
Sony KLV-40ZX1M (RM-VL610A Remote... User manual

Sony
Sony BVM-F24U Manual

Sony
Sony Multiscan GDM-F400 User manual

Sony
Sony LMDDM20 User manual

Sony
Sony CLX101ASA User manual

Sony
Sony BVM-E250 User manual

Sony
Sony PVM-740 User manual

Sony
Sony FW-85BZ40L User manual

Sony
Sony Trinitron HMD-A200 User manual

Sony
Sony Multiscan CPD-420GS User manual

Sony
Sony FD Trinitron GDM-F500R User manual

Sony
Sony FWD-42PX2 User manual

Sony
Sony LMD-B240 User manual

Sony
Sony SDM-HS73 User manual

Sony
Sony SDM-S76D User manual

Sony
Sony PFM-32C1 User manual

Sony
Sony BVM-X300 User manual