Example 1: If “42” is displayed
Higher bit: 4=0100 →b6
Lower bit: 2=0010 →b1
This case shows that retry was made due to combined causes of
“CLV unlock” and “ADIP error ”.
Example 2: If “A2” is displayed
Higher bit: A=1010 →b7 + b5
Lower bit: 2=0010 →b1
This case shows that retry was made due to combined causes of
“cannot access”, “IV-R”, and “ADIP error ”.
Note:Some sets may display “MD ERR TOC” depending on the
contents of CD disc to be recorded.
In this case, retry aging using another CD disc.
Error Message Description
1 MD ERR NO DISC TOC of MD cannot be read (disc
error, etc.)
2 MD ERR A-ERASE MD all erasing failed
(premaster, protect, or disc
error)
3 MD ERR R-PAUSE Pause of MD recording failed
4 MD ERR D-INPUT MD digital input is not locked
5 MD ERR PLAY Last music of MD cannot be
played (access error)
6 MD ERR TOC TOC content of MD is erroneous
(total tracks are wrong)
7 CD ERR FOCUS CD focusing failed
8 CD ERR GFS CD GFS failed
9 CD ERR TOC 16 seconds elapsed after TOC of
CD was read
10 CD ERR SEARCH 16 seconds elapsed after CD was
searched
11 CD ERR TRY1 SW Switch in CD tray 1 is faulty
12 CD ERR TRY2 SW Switch in CD tray 2 is faulty
13 CD ERR TRY3 SW Switch in CD tray 3 is faulty
14 CD ERR CARRIER Carrier operation did not com-
plete within the specified time
15 CD ERR GEAR Gear operation did not complete
within the specified time
16 CD ERR CHUCK Chucking did not complete
within the specified time
17 CD ERR TRY IN Tray was not closed within the
specified time
18 CD ERR TRY OUT Tray was not opened within the
specified time
19 CD ERR ServoOK
This massage is displayed when
the aging is tried through CD
aging is disabled due to other
than above causes.
Table 1-3. Error Messages