Sourcetronic ST2822 User manual

1
SOURCETRONIC GMBH
www.Sourcetronic.com
© 2010 SOURCETRONIC GmbH – All rights reserved.
Contact:
Model SST2822/ST2822A/ST2822C
Dual Handheld LCR Meter
Instruction Manual

2
Safety Summary
The following safety precautions are applicable
to both operating and maintenance personnel
and must be observed during all phases of
operation, service, and repair of this
instrument.
DO NOT OPERATE IN A FLAMMABLE OR
EXPLOSIVE ATMOSPHERE
Do not operate the instrument in the presence
of much dust, direct sunlight, high humidity,
strong electromagnetic radiation, etc.
NON-PROFESSIONALS SHOULD NOT OPEN
STE REAR COVER
Maintaining, substituting parts or adjusting the
instrument should be made by professional
maintenance personnel. Please contact
relevant distributor or Sourcetronics service
department.

3
DO NOT REMOVE OR MODIFY STE
INSTRUMENT
Some replacements and unauthorized
modifications might cause irreversible
damage to the instrument.
SAFETY WARNING
Strictly follow the relevant safety statements in
this manual involving safety, personnel injury,
damage to the instrument, operation and
environmental conditions causing poor test.

4
Safety Guidelines
To ensure that you use this device safely,
follow the safety guidelines listed below:
This meter is for indoor use, altitude up to
2,000 m. For short-time outdoor use,
precautions should be taken to avoid direct
sunlight, water and moisture,
electromagnetic radiation, dust and
explosion.
The warnings and safety precautions should
be read and well understood before the
instrument is used.
Use the meter only as specified in this
manual.
Confirm that the circuits have been powered
off and all capacitors in the circuits been
discharged before measuring in-circuit
components.
Discharge all charging elements, such as
capacitors, before testing.
The power for the meter is supplied with a
single standard 9V battery. But also a line
operation is possible using a power adapter

5
of 12VDC/150mA. If a power adapter is
selected, please be sure to meet the safety
requirements of a relevant IEC standard.
The battery using in ST2822C is
rechargeable. Do not charge non-
rechargeable batteries.
Safety Symbols
This symbol is a warning and
indicates that the user should refer to
the operating instructions located in
the manual.
D C power
Indicates inside pin is positive (+),
outside is negative (-) .

6
Environmental Conditions
Operating Environment
0 °C to 40 °C
Storage Humidity
0 – 80% R.H.
Storage Environment
-20 °C to +50 °C
Pollution degree
2

7
Contents
Safety Summary ....................................................... 2
Safety Guidelines ..................................................... 4
Introduction............................................................. 10
Package Contents .................................................. 11
Front Panel Overview............................................. 13
Front Panel Display Descriptions.................................. 14
Front Panel Buttons ...................................................... 16
Button Function Definition............................................. 17
LCD Display Overview .................................................. 18
LCD Display Descriptions ............................................. 18
Special Display Indicators............................................. 20
Test Port ....................................................................... 20
Powering Instrument.............................................. 22
Installing Battery ........................................................... 22
Connecting External Power Source .............................. 25
Low Battery Indication................................................... 27
Backlight Display........................................................... 28
Charge Display ............................................................. 29

8
Operation Instruction ............................................. 31
Data hold mode (HOLD) ............................................... 31
Data Record Mode (REC)............................................. 32
L/C/R/Z Select Mode..................................................... 34
D/Q/θ/ESR Select Mode ............................................... 35
Test Frequency (FREQ)................................................ 35
Tolerance Mode (TOL).................................................. 36
Auto LCR Mode ............................................................ 38
Measurement Rate (RATE) .......................................... 40
Series/parallel Equivalent Mode ................................... 40
Utility Menu (UTIL) ........................................................ 42
Clear Functions (CLEAR) ............................................. 53
Remote Control (RMT).................................................. 57
Fuse Detection.............................................................. 57
Quick Start Guide ................................................... 59
CAUTION...................................................................... 59
Inductance Measurement ............................................. 60
Capacitance Measurement ........................................... 63
Resistance Measurement ............................................. 65
Impedance Measurement ............................................. 67
Remote Communication ........................................ 68

9
Connecting Instrument to PC........................................ 68
Virtual Serial Port Configuration.................................... 70
RMT Operation ............................................................. 70
Command Protocols ..................................................... 73
Command Reference.................................................... 78
Specifications ......................................................... 85
General Specifications .................................................. 85
Accuracy Specifications ................................................ 88
Maintenance.............................................................. 1
Service ............................................................................ 1
Cleaning.......................................................................... 2
Limited Warranty ...................................................... 4

10
Introduction
ST2822 series are designed for measuring inductance,
capacitance and resistance components. The
instrument can be powered by a 9V battery or external
power adapter. The meter is not only applicable to the
application occasion of bench meters but also
conveniently used in the flow inspect and handheld
measurement occasions.
ST2822 series provide the primary parameter of up to
40,000 readings, secondary parameter of 0.0001
reading resolution, the maximum measuring
frequency of up to 100kHz, constant internal
resistance of 100Ωand testing level of 0.6Vrms. The
auto range can rapidly display the measuring results
and automatically choose the desirable testing
parameters in accordance with components properties.
Its measuring accuracy is up to 0.25%.
Front panel push buttons maximize the convenience
of function and feature selection such frequency, rate
and L/C/R/Z selection. Tolerance mode can sort
components, record mode aid to capture readings,
convenient open/short clear function improve the
measuring accuracy, utility menu help you easily take

11
the selections of the key tone, auto power-off and
storage.
All ST2822 series are equipped with the function of
remote communication. The test data can be
transferred to PC through a Mini USB connection,
great for applications that require remote control and
data acquisition.
Package Contents
ST2822 series are equipped with the following
contents:
•ST2822/ST2822A/ST2822C handheld LCR
meter
•Instruction manual
•Mini USB Interface Cable
•Red / Black Banana plugs—Crocodile clip
Test Leads
•Short-circuit plate
•*9V Alkaline battery or 8.4 rechargeable
battery
•*AC adapter
•*ST26027A Kelvin clip test leads
•* ST26009C SMD test tweezers
•*ST26029C SMD test tweezers

12
* This can be purchased as optional accessories.
All contents are subject to actual package list or box.
Please locate them from the original packaging to
ensure nothing is missing. If in the case that an item is
missing, please contact Sourcetronic or relevant
distributor immediately.

13
Front Panel Overview
Figure 1 - Front Panel Display (model ST2822C shown)
1
2
3
5
6
8
4
7
13
9
10
11
12
14

14
Front Panel Display Descriptions
1. LCD display
2. USB communication / *Back light button
3. Power ON/OFF button
4. Frequency and record mode selection
5. Secondary display mode (D /Q//ESR, etc.)
6. Primary display mode (L/C/R/Z, etc.)/ auto
LCR selection
7. Rate/equivalent mode selection
8. Hold mode/ utility menu
9. Tolerance mode/ utility arrow key
10. Open/short clear/ utility arrow key
11. 5-terminal test sockets (direct measurement
on lead components or use of test fixture)
12. 3-terminal test jacks (for use of Banana
plugs—Crocodile clip Test Leads)
13. Standard mini USB port (for remote control)
14. 12VDC external power input (use with an
external power adapter)
*Backlight is not included in ST2822.
NOTE: Refer to the adapter's label for input
parameters of it. Rated output parameters is 12VDC
,
150mA
,
4mm.
NOTE: Use with included power adapter only or
purchase the specified adapters from Sourcetronic.

15
Use with improper power adapters may damage
instrument.
NOTE: Internal battery supply will be
automatically cut off since the normal supply of
external power. If the battery is rechargeable
(ST2822C), the external power will charge the battery
simultaneously. ST2822C is installed an independent
charging controller---charging control is still done even
at the state of power-off.
WARNING: Before connecting an external
power adapter, be sure that the polarity matches
the (+) and (-) labels as indicated inside the battery
compartment. If it is not installed correctly and
connected to an external power adapter, it might
cause severe damage to the instrument.
WARNING: If the battery is rechargeable
(ST2822C), please be sure that the polarity
matches the (+) and (-) labels as indicated inside
the battery compartment ant the battery is
rechargeable. DO NOT charge the non-
rechargeable battery!

16
Front Panel Buttons
With the exception of the power button, all front panel
buttons have specific colored labels on them. They
are all marked in black, blue, or orange color. Each
color has a specific representation, as described
below:
Black—the primary function,meaning that
function will be set or configured upon pressing it.
Orange—the secondary function, it means that
the function will be set or configured if that button is
pressed and hold down for 2 seconds.
Blue—the utility function, the function will be set
or configured if the UTIL button is pressed and hold
down for a long time. See “Utility Menu” section for
details.
NOTE: In the button operational instruction, we
will use the button name to express the button
operation without differentiating the type of button;
Pay attention to the difference between “long press”
and “press”.

17
Figure 2 –Button Display (Model ST2822C shown)
Button Function Definition
1.Power ON/OFF Button
2.Frequency/Record Mode Button
3.Remote Control/Backlight Button
4.Readings Hold/Utility Menu Button
5.Tolerance mode/ Menu Selection Button
6.Clear/ Menu Selection Button
7.Rate/Equivalent Mode Button
8.LCR Primary Parameters/Auto LCR
9.Secondary Parameters Selection Button

18
LCD Display Overview
Figure 3 - LCD Indicator Display
LCD Display Descriptions
1. LCRZ – Primary display indicator
2. MAX – Maximum reading indicator in the
record mode
3. AVG – Average reading indicator in the record
mode
4. MIN – Minimum reading indicator in the record
mode
5. AUTO – Automatic LCR indicator
6. θ– Phase angle indicator for secondary
display

19
7.D – Dissipation indicator
8.Q – Quality factor indicator
9.– Secondary display
10. – Beeper tone indicator for tolerance
mode
11. deg – Phase angle (θ) units indicator
12. Ω– ESR(ohm) units indicator
13. % - Percentage indicator (in tolerance mode)
14. kHz – Frequency units indicator
15. PAL – Parallel mode indicator
16. SER – Series mode indicator
17. – Inductance units (L) indicator
18. –Capacitance units (C) indicator
19. MkΩ– Resistance(R) /impedance units
indicator
20. RMT – Remote mode indicator
21. – Primary display
22. ESR – Series mode indicator for secondary
parameters
23. DH – Data hold indicator
24. SLOW – measuring rate indicator
25. 2105% - Limits indicator in tolerance mode
26. FAST- Fast measuring rate indicator
27. – Low battery/charging indicator
28. @OFF –Auto power-off indicator

20
29. TOL –Tolerance mode indicator
Special Display Indicators
Indicates short clear if you press the CLEAR
button
Indicates open clear if you press the CLEAR
button
Error indication
Indicates correction (open/short clear) mode
Indicates damaged or open fuse
AD converter error(UNK)
AD converter error(END)
Test Port
ST2822 series are creatively designed to combine 3-
terminal port and 5-terminal port, which makes the
This manual suits for next models
3
Table of contents
Other Sourcetronic Measuring Instrument manuals

Sourcetronic
Sourcetronic ST2829A User manual

Sourcetronic
Sourcetronic TH2516 Series User manual

Sourcetronic
Sourcetronic ST2822D User manual

Sourcetronic
Sourcetronic MPK-204e User manual

Sourcetronic
Sourcetronic MPK-102e User manual

Sourcetronic
Sourcetronic ST2683A User manual

Sourcetronic
Sourcetronic ST2638 Series User manual

Sourcetronic
Sourcetronic ST1778A User manual

Sourcetronic
Sourcetronic MPK-2000e User manual

Sourcetronic
Sourcetronic ST2684A User manual