Spectracom TV210V User manual

TIMEVIEW DIGITAL DISPLAY CLOCK
MODELS TV210V, U, G, W & TV400V, U, G, W
INSTRUCTION MANUAL
SPECTRACOM CORPORATION
95 METHODIST HILL DRIVE
ROCHESTER,NY 14623
PHONE 585.321.5800
FAX 585.321.5219
www.spectracomcorp.com
Part Number 1144-5000-0050
Manual Revision A
November 2005

Copyright © 2005 Spectracom Corporation. The contents of this publication may not be
reproduced in any form without the written permission of Spectracom Corporation. Printed in
USA.
Specifications subject to change or improvement without notice.
Spectracom, NetClock, Ageless, TimeGuard, TimeBurst, TimeTap, LineTap, MultiTap,
VersaTap, and Legally Traceable Time are Spectracom registered trademarks. All other
products are identified by trademarks of their respective companies or organizations. All rights
reserved.

SPECTRACOM 95 Methodist Hill Drive Rochester, NY 14623
SPECTRACOM LIMITED WARRANTY
LIMITED WARRANTY
Spectracom warrants each new product manufactured and
sold by it to be free from defects in software, material,
workmanship, and construction, except for batteries, fuses, or
other material normally consumed in operation that may be
contained therein AND AS NOTED BELOW, for five years after
shipment to the original purchaser (which period is referred to
as the “warranty period”). This warranty shall not apply if the
product is used contrary to the instructions in its manual or is
otherwise subjected to misuse, abnormal operations, accident,
lightning or transient surge, repairs or modifications not
performed by Spectracom.
The GPS receiver is warranted for one year from date of
shipment and subject to the exceptions listed above. The
power adaptor, if supplied, is warranted for one year from date
of shipment and subject to the exceptions listed above.
THE ANALOG CLOCKS ARE WARRANTED FOR ONE YEAR
FROM DATE OF SHIPMENT AND SUBJECT TO THE
EXCEPTIONS LISTED ABOVE.
THE TIMECODE READER/GENERATORS ARE WARRANT-
ED FOR ONE YEAR FROM DATE OF SHIPMENT AND
SUBJECT TO THE EXCEPTIONS LISTED ABOVE.
The Rubidium oscillator, if supplied, is warranted for two years
from date of shipment and subject to the exceptions listed
above.
All other items and pieces of equipment not specified above,
including the antenna unit, antenna surge suppressor and
antenna pre-amplifier are warranted for 5 years, subject to the
exceptions listed above.
WARRANTY CLAIMS
Spectracom’s obligation under this warranty is limited to in-
factory service and repair, at Spectracom’s option, of the
product or the component thereof, which is found to be
defective. If in Spectracom’s judgment the defective condition
in a Spectracom product is for a cause listed above for which
Spectracom is not responsible, Spectracom will make the
repairs or replacement of components and charge its then
current price, which buyer agrees to pay.
Spectracom shall not have any warranty obligations if the
procedure for warranty claims is not followed. Users must
notify Spectracom of the claim with full information as to the
claimed defect. Spectracom products shall not be returned
unless a return authorization number is issued by Spectracom.
Spectracom products must be returned with the description of
the claimed defect and identification of the individual to be
contacted if additional information is needed. Spectracom
products must be returned properly packed with transportation
charges prepaid.
Shipping expense: Expenses incurred for shipping
Spectracom products to and from Spectracom (including
international customs fees) shall be paid for by the customer,
with the following exception. For customers located within the
United States, any product repaired by Spectracom under a
“warranty repair” will be shipped back to the customer at
Spectracom’s expense unless special/faster delivery is
requested by customer.
Spectracom highly recommends that prior to returning
equipment for service work, our technical support department
be contacted to provide trouble shooting assistance while the
equipment is still installed. If equipment is returned without
first contacting the support department and “no problems are
found” during the repair work, an evaluation fee may be
charged.
EXCEPT FOR THE LIMITED WARRANTY STATED ABOVE,
SPECTRACOM DISCLAIMS ALL WARRANTIES OF ANY
KIND WITH REGARD TO SPECTRACOM PRODUCTS OR
OTHER MATERIALS PROVIDED BY SPECTRACOM,
INCLUDING WITHOUT LIMITATION ANY IMPLIED
WARRANTY OR MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.
Spectracom shall have no liability or responsibility to the
original customer or any other party with respect to any liability,
loss, or damage caused directly or indirectly by an Spectracom
product, material, or software sold or provided by Spectracom,
replacement parts or units, or services provided, including but
not limited to any interruption of service, excess charges
resulting from malfunctions of hardware or software, loss of
business or anticipatory profits resulting from the use or
operation of the Spectracom product or software, whatsoever
or howsoever caused. In no event shall Spectracom be liable
for any direct, indirect, special or consequential damages
whether the claims are grounded in contract, tort (including
negligence), or strict liability.
EXTENDED WARRANTY COVERAGE
Extended warranties can be purchased for additional periods
beyond the standard five-year warranty. Contact Spectracom
no later than the last year of the standard five-year warranty for
extended coverage.


Spectracom Corporation TV210V, U, G, W & TV400 V, U, G, W
TimeView Digital Display Clocks Instruction Manual iii
Table of Contents
1INTRODUCTION ..................................................................................... 1-1
1.1 Wired Clock Features....................................................................................................................1-3
1.2 Wireless Clock Features................................................................................................................1-3
1.3 Warranty Information and Product Support ...................................................................................1-4
1.4 Manual Errata and Special Documentation...................................................................................1-4
1.5 Unpacking......................................................................................................................................1-5
1.6 Specifications................................................................................................................................1-6
1.6.1 TimeView 210 Wired.............................................................................................................1-7
1.6.2 TimeView 210 Wireless ........................................................................................................1-8
1.6.3 TimeView 400 Wired.............................................................................................................1-9
1.6.4 TimeView 400 Wireless ......................................................................................................1-10
2INSTALLATION ....................................................................................... 2-1
2.1 Mounting Instructions ....................................................................................................................2-1
2.1.1 Wall Mounting – TimeView 210 Series .................................................................................2-1
2.1.2 Bulkhead Mounting – TimeView 210 Series..........................................................................2-2
2.1.3 Wall Mounting – TimeView 400 Series .................................................................................2-2
2.2 Power – TimeView 210 Series.......................................................................................................2-3
2.3 Power – TimeView 400 Series.......................................................................................................2-3
2.4 Wired Clock Configuration.............................................................................................................2-4
2.4.1 Display Settings....................................................................................................................2-5
2.4.2 Setting the Time....................................................................................................................2-6
2.4.3 Setting the Group and Sub-Group Addresses.......................................................................2-6
2.4.4 Exit Configuration Mode........................................................................................................2-8
2.4.5 RS-485 Connection...............................................................................................................2-9
2.5 Wireless Clock Configuration.......................................................................................................2-12
2.5.1 RF Meter.............................................................................................................................2-14
2.5.2 Setting the Buzzer Volume .................................................................................................2-16
2.5.3 Setting the Radio Frequency...............................................................................................2-17
2.5.4 Display Settings..................................................................................................................2-18
2.5.5 Exit Configuration Mode......................................................................................................2-19
2.5.6 TimeBurst Configuration.....................................................................................................2-19
2.5.7 Wired RS-485 Ports............................................................................................................2-20
2.5.8 Verifying Operation.............................................................................................................2-21

TV210V, U, G, W & TV400 V, U, G, W Spectracom Corporation
TimeView Digital Display Clocks Instruction Manualiv
List of Figures
Figure 1-1: Spectracom TV210 Series (Front)............................................................................................1-1
Figure 1-2: Spectracom TV400 Series (Front)............................................................................................1-2
Figure 2-1: Duplex Mounting Holes............................................................................................................2-1
Figure 2-2: Duplex Mounting Holes............................................................................................................2-2
Figure 2-3: TimeView 210W Rear Panel....................................................................................................2-4
Figure 2-4: RS-485 Connection..................................................................................................................2-9
Figure 2-5: Installation Using Repeater Output.........................................................................................2-10
Figure 2-6: Repeater Output Use..............................................................................................................2-10
Figure 2-7: Termination Resistor..............................................................................................................2-11
Figure 2-8: TimeView 210 Rear Panel......................................................................................................2-12
Figure 2-9: Rear Panel Ports....................................................................................................................2-20
List of Tables
Table 1-1: Ancillary Kits..............................................................................................................................1-5
Table 1-2: External Antennas.....................................................................................................................1-5
Table 2-1: Mode Switch Function Chart......................................................................................................2-5
Table 2-2: Mode Switch Function Chart....................................................................................................2-13

Spectracom Corporation TV210V, U, G, W & TV400 V, U, G, W
TimeView Digital Display Clocks Instruction Manual 1
-
1
1Introduction
The Spectracom TimeView digital models are synchronized display clocks visible from
at least 75 feet (23 meters – TV210 series) to 150 feet (46 meters – TV400 series).
Both clocks have large, easily seen LED digits – 2.3 inches (58.4 mm) in the TV210
series and 4 inches (101.6 mm) in the TV400 series.
The TimeView digital clocks are part of Spectracom Corporation’s display family of
products, used to distribute accurate and traceable timing throughout a single facility or
across an entire community. In addition to the digital display clocks, Spectracom offers
TimeView 312 wired and wireless analog display clocks.
Spectracom’s digital clocks display Legally Traceable Time®in 12- and 24-hour formats
when referenced to a NetClock®receiver. The synchronization options available for the
TimeView digital clocks are RS-485 wired data input (210W and 400W models) and
wireless (TV210V, TV400V, TV210U, TV400U, TV210G, TV400G). Check the serial
tag on the rear panel of your unit to determine the model number of your equipment.
Figure 1-1: Spectracom TV210 Series (Front)
Spectracom currently offers NetClock GPS synchronized receivers and previously
offered WWVB synchronized receivers. In wireless applications, the NetClock feeds a
continuous time data stream to a Model 8185 TimeBurst™. The TimeBurst connects to
the customer’s radio console or transmitter to provide wireless synchronization. On a
schedule chosen by the customer, the TimeBurst automatically keys the transmitter and
sends a short coded time of day message in the form of a digital burst. TimeBurst is
“polite” to voice communications and will wait for “clear air” to transmit.
The wired digital display clocks have no radio receivers. Each Spectracom wired
display product connects to an RS-485 continuous time data stream provided by a
NetClock receiver or the RS-485 output of an Ethernet time server. The wired display
clocks decode the time data stream and then synchronize to within 250 milliseconds of
the traceable NetClock receiver.

TV210V, U, G, W & TV400 V, U, G, W Spectracom Corporation
TimeView Digital Display Clocks Instruction Manual1-2
Figure 1-2: Spectracom TV400 Series (Front)
The wireless TimeView digital display clocks have internal radio receivers, built-in and
optional (TV210 series) external antennas, or required and included (TV400 series)
external antennas. Each wireless TimeView clock decodes the TimeBurst transmission
and synchronizes to within 250 milliseconds of the traceable NetClock receiver.
Spectracom offers VHF FM, UHF FM commercial, and UHF FM government band
versions of the digital TimeView clocks. Specify TimeView 210V or 400V for VHF FM
frequencies, TimeView 210U or 400U for UHF FM commercial, and TimeView 210G or
400G for UHF FM government band.
210 Series 400 Series
Wired TV210W TV400W
TV210V TV400V
TV210U TV400U
Wireless
TV210G TV400G

Spectracom Corporation TV210V, U, G, W & TV400 V, U, G, W
TimeView Digital Display Clocks Instruction Manual 1
-
3
1.1 Wired Clock Features
Spectracom’s wired digital display clocks offer the following features:
•Accuracy: TimeView digital clocks display Legally Traceable Time when referenced
to a NetClock. The time is accurate to within 250 milliseconds of the NetClock’s
time.
•Exceptional Visibility: Large LED digits – 2.3 inches (58.4 mm) in the TV210 series
and 4 inches (101.6 mm) in the TV400 series – and anti-glare display filters provide
optimum viewing.
•Configurable Time Display: Each clock can be configured to display time in either
12- or 24-hour format.
•Ease of Installation: Automatic data format and baud rate detection makes setup
and installation easy.
1.2 Wireless Clock Features
Spectracom’s wireless digital display clocks offer the following features:
•Wireless Synchronization to NetClock via TimeBurst and Radio: The wireless
communication link eliminates costly wiring and labor expenses while simplifying
installation.
•Accuracy: TimeView digital clocks display Legally Traceable Time when connected
to a NetClock. The time is accurate to within 250 milliseconds of the NetClock’s
time.
•Exceptional Visibility: Large LED digits – 2.3 inches (58.4 mm) in the TV210 series
and 4 inches (101.6 mm) in the TV400 series – and anti-glare display filters provide
optimum viewing.
•Configurable Time Display: Each clock can be configured to display time in either
12- or 24-hour format.
•Received Signal Strength Indicator: A digital RF meter provides a quick method to
assess radio signal coverage and simplifies installation.
•RS-485 Output: Serial time code data is provided to connect to products requiring
RS-485 data input. This allows a wireless clock to synchronize Spectracom wired
display clocks and TimeTap®devices.

TV210V, U, G, W & TV400 V, U, G, W Spectracom Corporation
TimeView Digital Display Clocks Instruction Manual1-4
1.3 Warranty Information and Product Support
Warranty information is found on the leading pages of this manual. Should it become
necessary to exercise the warranty, contact Spectracom Corporation to obtain a
replacement or service.
Spectracom continuously strives to improve its products and greatly appreciates any
and all customer feedback given. Please participate in Spectracom’s Customer
Satisfaction Survey found on our web site, http://www.spectracomcorp.com.
Technical support is available by telephone, via e-mail, or online. Please direct any
comments or questions regarding application, operation, or service to Spectracom’s
Customer Service department. Customer Service is available Monday through Friday
from 8:30 a.m. to 5:00 p.m. EST. Customer Service can be reached by phone at
585.321.5800.
Please contact Customer Service to obtain a Return Material Authorization Number
(RMA#) before returning any instrument to Spectracom. Please provide the serial
number and failure symptoms. Shipping to the factory is to be prepaid by the customer.
After obtaining the RMA#, ship the unit back to the following address:
Spectracom Corporation
Repair Department, RMA# xxxxx
95 Methodist Hill Drive
Rochester, NY 14623
Product support is also available by e-mail. Questions on equipment operation and
applications may be e-mailed to Spectracom Sales Support
Repair or technical questions may be e-mailed directly to Spectracom’s technicians:
Visit our web page for product information, application notes, and upgrade notices as
they become available:
http://www.spectracomcorp.com
1.4 Manual Errata and Special Documentation
Information concerning manual corrections or product changes occurring after printing is
found in the Errata Section. The Errata Section, when required, is found at the end of
this manual. Please review and incorporate changes into the manual whenever an
Errata Section is included.
Spectracom will make instrument modifications on special request. A documentation
packet associated with the modification will be provided in addition to this manual.

Spectracom Corporation TV210V, U, G, W & TV400 V, U, G, W
TimeView Digital Display Clocks Instruction Manual 1
-
5
1.5 Unpacking
On receipt, carefully examine the carton and its contents. If there is damage to the
carton resulting in damage to the unit, contact the carrier immediately. Retain the carton
and packing materials in the event the carrier wishes to witness the shipping damage.
Failing to report shipping damage immediately may forfeit any claim against the carrier.
In addition, notify Spectracom Corporation of shipping damage or shortages to obtain a
replacement or repair services.
Remove the packing list from the envelope on the outside of the carton. Check the
packing list against the contents to be sure all items have been received, including an
instruction manual and ancillary kit. Table 1-1 lists the items included in the various
ancillary kits.
Ancillary Kit Items Supplied with All Display Clocks
Description Part Number Quantity
Plastic Anchor HD0001 2
Screw, #6 x 1” H100-1000-0016 2
Terminal Strip P13006 1
Resister, 120 Ohms R02121 1
Ancillary Kit Items Supplied with 210 Series Only
Description Part Number Quantity
Power Adapter, 12 VDC PS03-0T0J-WM01 1
Ancillary Kit Items Supplied with 400 Series Only
Description Part Number Quantity
Power Adapter, 12 VDC PS06-0E0J-DT01 1
Line Cord W01000 1
Table 1-1: Ancillary Kits
Wireless units ordered with an optional external antenna (210 series) or shipped with a
required, included antenna (400 series) receive an antenna suited for the specified
frequency band. Refer to Table 1-2 and verify that the appropriate antenna has been
shipped with your unit(s).
Frequency Band Frequency Range SpectracomPartNumber
150-162 MHz E030-0003-0150
VHF 160-174 MHz E030-0004-0160
UHF Commercial 400-512 MHz E030-0005-0450
UHF Government 400-420 MHz E030-0002-0420
Table 1-2: External Antennas

TV210V, U, G, W & TV400 V, U, G, W Spectracom Corporation
TimeView Digital Display Clocks Instruction Manual1-6
1.6 Specifications
Refer to sections 1.6.1, 1.6.2, 1.6.3, and 1.6.4 for digital display clock specifications.

Spectracom Corporation TV210V, U, G, W & TV400 V, U, G, W
TimeView Digital Display Clocks Instruction Manual 1
-
7
1.6.1 TimeView 210W (Wired)
PERFORMANCE
TIMING ACCURACY:
+/- 250 milliseconds
FRONT PANEL
DISPLAY:
•Green LED standard; red LED optional; 12- or 24-hour
•2.3” (58 mm) hours and minutes digits
•1.0” (25 mm) seconds digits
•Visibility to 75 feet (23 meters)
•Seconds digits blink to indicate loss of time synchronization
REAR PANEL
SELECTABLE FUNCTIONS:
Set-up switches configure:
•Manual time set
•12- or 24-hour display
•Brightness
•Settings retained in non-volatile memory
INPUT PORT:
RS-485 input three-position terminal block
•RS-485 over a balanced wire pair
•SmartBus automatically detects baud rate (1200-9600)
•SmartBus automatically detects required time code Format 0
or 1 from NetClock® master clock or computer using TimeSet
TS-1 software or wireless TimeView
OUTPUT PORT:
•RS-485 output three-position terminal block
•RS-485 repeater of input port signal
•Capable of driving TimeTaps® (8179T) and wired wall clocks
(TV210W/TV400W/TV312W)
POWER:
100-250 VAC, 47-63 Hz to 12 VDC @ 9.6 watts max. from external
UL/CSA approved power supply. Re-order number: PS03-0T0J-
WM01. Barrel-type power connector; 5.5 mm OD, 2.5 mm ID, female,
center positive.
BATTERY BACK-UP:
10-yr storage/operating life lithium battery maintains internal time
during power interruption.
PHYSICAL & ENVIRONMENTAL
SIZE/WEIGHT:
13" L x 4.9" H x 2.7" D, 2.2 lbs
(330 mm L x 124 mm H x 69 mm D, 1.0 kg)
ENVIRONMENTAL:
Operating Range: 32° F to 140° F (0° C to 60° C)
Storage Range: -40° F to 185° F (-40° C to 85° C)
Relative Humidity: 10-95%, non-condensing
AGENCY APPROVALS:
UL/CSA (power supply)
WARRANTY
FIVE YEAR LIMITED WARRANTY
ORDERING INFORMATION
1. TimeView® Display Clock
TimeView 210 Display Clock – Model TV210W
2. Option 05: Red Digits
ADDITIONAL ACCESSORIES
3. Cable – CW04xxx, a twisted pair wire to connect TV210W to 91XX
or other clocks; and CA14xxx, and RS-485 cable (where xxx = length
in feet)
4. Software
TimeSet-TS-1 to synchronize TimeView Display Clocks from Win
95/98/NT or DOS computers.

TV210V, U, G, W & TV400 V, U, G, W Spectracom Corporation
TimeView Digital Display Clocks Instruction Manual1-8
1.6.2 TimeView 210V, U, G (Wireless)
PERFORMANCE
TIMING ACCURACY:
+/- 250 milliseconds
RADIO RECEIVER:
•FM receiver; supports standard and narrow-band FM voice channels
•6.25 KHz channel spacing
•2.5 or 5 KHz FM deviation
•Operates on 25 or 12.5 KHz channels
•VHF: 150-174 MHz (programmable)
•UHF (commercial band): 440-470 MHz (programmable)
•UHF (government band): 406-420 MHZ (programmable)
SENSITIVITY
-107 dBm (1 uV) typical at receiver RF input
FRONT PANEL
DISPLAY:
•Green LED standard; red LED optional; 12- or 24-hour
•2.3” (58 mm) hours and minutes digits
•1.0” (25 mm) seconds digits
•Visibility to 75 feet (23 meters)
•Seconds digits blink to indicate loss of time synchronization
•Decimal point of hours digit flashes for one second when time data is
received
REAR PANEL
SELECTABLE FUNCTIONS:
Set-up switches configure:
•Manual time set
•12- or 24-hour display
•Brightness
•RF frequency
•RF signal strength
•Grouping
•Buzzer volume for options 01, 02, 03
•Settings retained in non-volatile memory
OUTPUT PORTS:
Two RS-485 output three-position terminal blocks
•Once per-second serial time code (format 0), 9600 baud
•Format 5 output included for event alert options
•Capable of driving TimeTaps® (8179T) and wired wall clocks
(TV210W/TV400W/TV312W)
•Accurate to +/- 75 msec (updated once per hour)
POWER:
100-250 VAC, 47-63 Hz to 12 VDC @ 9.6 watts max. from external
UL/CSA approved power supply. Re-order number: PS03-0T0J-
WM01. Barrel-type power connector; 5.5 mm OD, 2.5 mm ID, female,
center positive.
BATTERY BACK-UP:
10-yr storage/operating life lithium battery maintains internal time
during power interruption.
PHYSICAL & ENVIRONMENTAL
SIZE/WEIGHT:
13" L x 4.9" H x 2.7" D, 2.2 lbs
(330 mm L x 124 mm H x 69 mm D, 1.0 kg)
ENVIRONMENTAL:
Operating Range: 32° F to 140° F (0° C to 60° C)
Storage Range: -40° F to 185° F (-40° C to 85° C)
Relative Humidity: 10-95%, non-condensing
AGENCY APPROVALS:
UL/CSA (power supply)
FCC Part 15 Class B
WARRANTY
FIVE YEAR LIMITED WARRANTY
ORDERING INFORMATION
1. TimeView® Display Clock
TimeView 210 Display Clock – Model TV210V
TimeView 210 Display Clock – Model TV210U
TimeView 210 Display Clock – Model TV210G
2. Option 01: Event Alert – top lights (LEDs) and internal buzzer
3. Option 02: Event Alert – bottom lights (LEDs) and internal buzzer
4. Option 03: Event Alert – top & bottom lights (LEDs) and internal buzzer
5. Option 04: External antenna and connector
6. Option 05: Red Digits (TV210U only)

Spectracom Corporation TV210V, U, G, W & TV400 V, U, G, W
TimeView Digital Display Clocks Instruction Manual 1
-
9
1.6.3 TimeView 400W (Wired)
PERFORMANCE
TIMING ACCURACY:
+/- 250 milliseconds
FRONT PANEL
DISPLAY:
•Green LED standard; red LED optional; 12- or 24-hour
•4” (101 mm) hours and minutes digits
•2.3” (58 mm) seconds digits
•Visibility to 150 feet (46 meters)
•Seconds digits blink to indicate loss of time synchronization
REAR PANEL
SELECTABLE FUNCTIONS:
Set-up switches configure:
•Manual time set
•12- or 24-hour display
•Brightness
•Settings retained in non-volatile memory
INPUT PORT:
RS-485 input three-position terminal block
•RS-485 over a balanced wire pair
•SmartBus automatically detects baud rate (1200-9600)
•SmartBus automatically detects required time code Format 0
or 1 from NetClock® master clock or computer using TimeSet
TS-1 software or wireless TimeView
OUTPUT PORT:
•RS-485 output three-position terminal block
•RS-485 repeater of input port signal
•Capable of driving TimeTaps® (8179T) and wired wall clocks
(TV210W/TV400W/TV312W)
POWER:
100-250 VAC, 47-63 Hz to 12 VDC @ 18 watts max. from external
CE/UL/CSA approved power supply. Re-order number: PS06-0E0J-
DT01. Barrel-type power connector; 5.5 mm OD, 2.5 mm ID, female,
center positive
BATTERY BACK-UP:
10-yr storage/operating life lithium battery maintains internal time
during power interruption.
PHYSICAL & ENVIRONMENTAL
SIZE/WEIGHT:
21"L x 7.5"H x 3.4"D, 8.5 lbs
(533 mm H x 191 mm W x 86 mm D, 3.9 kg)
ENVIRONMENTAL:
Operating Range: 32° F to 122° F (0° C to 50° C)
Storage Range: -40° F to 185°O F (-40° C to 85° C)
Relative Humidity: 10-95%, non-condensing
AGENCY APPROVALS:
CE/UL/CSA (power supply)
WARRANTY
FIVE YEAR LIMITED WARRANTY
ORDERING INFORMATION
1. TimeView® Display Clock
TimeView 400 Display Clock – Model TV400W
2. Option 05: Red Digits
ADDITIONAL ACCESSORIES
3. Cable – CW04xxx, a twisted pair wire to connect TV400W to 91XX
or other clocks; and CA14xxx, and RS-485 cable (where xxx = length
in feet)
4. Software
TimeSet-TS-1 to synchronize TimeView Display Clocks from Win
95/98/NT or DOS computers.

TV210V, U, G, W & TV400 V, U, G, W Spectracom Corporation
TimeView Digital Display Clocks Instruction Manual1-10
1.6.4 TimeView 400V, U, G (Wireless)
PERFORMANCE
TIMING ACCURACY:
+/- 250 milliseconds
RADIO RECEIVER:
•FM receiver; supports standard and narrow-band FM voice channels
•6.25 KHz channel spacing
•2.5 or 5 KHz FM deviation
•Operates on 25 or 12.5 KHz channels
•VHF: 150-174 MHz (programmable)
•UHF (commercial band): 440-470 MHz (programmable)
•UHF (government band): 406-420 MHZ (programmable)
SENSITIVITY
-107 dBm (1 uV) typical at receiver RF input
FRONT PANEL
DISPLAY:
•Green LED standard; red LED optional; 12- or 24-hour
•4” (101 mm) hours and minutes digits
•2.3” (58 mm) seconds digits
•Visibility to
150 feet (46meters)
•Seconds digits blink to indicate loss of time synchronization
•Decimal point of hours digit flashes for one second when time data is
received
REAR PANEL
SELECTABLE FUNCTIONS:
Set-up switches configure:
•Manual time set
•12- or 24-hour display
•Brightness
•RF frequency
•RF signal strength
•Grouping
•Buzzer volume for options 01, 02, 03
•Settings retained in non-volatile memory
OUTPUT PORTS:
Two RS-485 output three-position terminal blocks
•Once per-second serial time code (format 0), 9600 baud
•Format 5 output included for event alert options
•Capable of driving TimeTaps® (8179T) and wired wall clocks
(TV210W/TV400W/TV312W)
•Accurate to +/- 75 msec (updated once per hour)
POWER:
100-250 VAC, 47-63 Hz to 12 VDC @ 18 watts max. from external
CE/UL/CSA approved power supply. Re-order number: PS06-0E0J-
DT01. Barrel-type power connector; 5.5 mm OD, 2.5 mm ID, female,
center positive.
BATTERY BACK-UP:
10-yr storage/operating life lithium battery maintains internal time
during power interruption.
PHYSICAL & ENVIRONMENTAL
SIZE/WEIGHT:
21"L x 7.5"H x 3.4"D, 8.5 lbs
(533 mm L x 191 mm H x 86 mm D, 3.9 kg)
ENVIRONMENTAL:
Operating Range: 32° F to 122° F (0° C to 50° C)
Storage Range: -40° F to 185° F (-40° C to 85° C)
Relative Humidity: 10-95%, non-condensing
AGENCY APPROVALS:
CE/UL/CSA (power supply)
WARRANTY
FIVE YEAR LIMITED WARRANTY
ORDERING INFORMATION
1. TimeView® Display Clock
TimeView 400 Display Clock – Model TV400V
TimeView 400 Display Clock – Model TV400U
TimeView 400 Display Clock – Model TV400G
2. Option 01: Event Alert – top lights (LEDs) and internal buzzer
3. Option 02: Event Alert – bottom lights (LEDs) and internal buzzer
4. Option 03: Event Alert – top & bottom lights (LEDs) and internal buzzer
5. Option 04: External antenna and connector
6. Option 05: Red Digits (TV400U only)

Spectracom Corporation TV210V, U, G, W & TV400 V, U, G, W
TimeView Digital Display Clocks Instruction Manual 2
-
1
2Installation
The following sections describe mounting, set up configuration and verification of
operation for the TimeView 210 series and TimeView 400 series digital display clocks.
To ensure proper operation, please read the applicable sections for your equipment
prior to installation and use of the product(s).
2.1 Mounting Instructions
The TimeView clocks are designed to mount over a duplex outlet to completely conceal
the power adapter. For installations where this is not possible, clearance is provided
along the top and bottom edges for routing the power cable. The 210 series clocks
have mounting holes that allow for wall or bulkhead mounting. The 400 series clocks
have mounting holes that allow for wall mounting only.
2.1.1 Wall Mounting – TimeView 210 Series
The ancillary kit includes screws and plastic anchors for wall mounting the clock. Tools
needed for wall mounting are a Phillips screwdriver, a ruler, and a ¼"inch drill.
To wall mount the TimeView 210 over a duplex outlet, lay a reference line through the
center of the cover plate as shown in Figure 2-1. Mark and drill two holes 8.25 inches
apart and centered on the outlet.
8.25
1/4" DIAMETER HOLES (2)
FOR ANCHORS ALIGNED
WITH HOLE IN COVER PLATE
OUTLET COVER PLATE
1.75
11.75
0.62
11/64" DIAMETER HOLES (4)
FOR BULKHEAD MOUNTING
Figure 2-1: Duplex Mounting Holes

TV210V, U, G, W & TV400 V, U, G, W Spectracom Corporation
TimeView Digital Display Clocks Instruction Manual2-2
2.1.2 Bulkhead Mounting – TimeView 210 Series
The TimeView 210 can be bulkhead mounted using the threaded holes found on the
rear panel. These holes accept #8-32 screws. Locate the four bulkhead mounting
holes as shown in Figure 2-1.
The four holes form a rectangle measuring 11.75 inches long and 1.75 inches high.
Drill 11/64-inch holes at each corner of the rectangle. Secure the clock to the mounting
surface using #8-32 screws.
NOTE: The bulkhead mounting screws may protrude into the clock a maximum of ½
inches. Longer screws will not fully tighten the clock against the mounting
surface.
2.1.3 Wall Mounting – TimeView 400 Series
The TimeView 400 series clock is designed to mount over a duplex outlet to completely
conceal the power adapter and line cord. For installations where this is not possible,
clearance is provided along the top and bottom edges for routing the power and data
cables.
The ancillary kit includes screws and plastic anchors for wall mounting the clock. Tools
needed for wall mounting are a Phillips screwdriver, a ruler, and a ¼"inch drill.
To wall mount the TimeView 400 over a duplex outlet, lay a reference line over the
cover plate as shown in Figure 2-2. Mark and drill two holes 16.0 inches apart and
centered on the outlet.
Figure 2-2: Duplex Mounting Holes

Spectracom Corporation TV210V, U, G, W & TV400 V, U, G, W
TimeView Digital Display Clocks Instruction Manual 2
-
3
2.2 Power – TimeView 210 Series
Plug the AC adapter into the top outlet with the cord facing downward. Initially the
seconds digits will blink to indicate the clock has not time-synchronized to the NetClock.
The seconds will continue flashing until the clock receives a synchronizing data stream.
An international power supply (supplied with 400 series clocks) is available for purchase
with 210 series clocks under part number PS06-0E0J-DT01. This adapter operates on
100-250 VAC 50/60 HZ power.
NOTE: The PS06-0E0J-DT01 adapter requires additional mounting space, such as in
an 8" x 8" electrical box, because it is too large to fit behind the 210 series
clocks.
2.3 Power – TimeView 400 Series
The power pack and line cord are packaged in the ancillary kit. The power adapter
operates on 100-250 VAC 50/60 Hz power. The provided line cord is compatible with
AC receptacles (NEMA 5-15R) commonly found in the United States and Canada.
Alternate type line cords must be obtained locally.
Initially the seconds digits will blink to indicate the clock has not time-synchronized to
the NetClock. The seconds will continue flashing until the clock receives a
synchronizing data stream.

TV210V, U, G, W & TV400 V, U, G, W Spectracom Corporation
TimeView Digital Display Clocks Instruction Manual2-4
2.4 Wired Clock Configuration
Before placing the TimeView wired clocks into service, the clocks must be configured to
suit the application(s). The clocks’ configuration options include 12- or 24-hour display
format, display brightness, and manual time setting for stand-alone clock operation.
Optionally, the TimeView can be equipped with LED status lamps and a buzzer that can
be activated over the RS-485 data stream. In most applications only the display format
(12- or 24-hour) will need to be configured.
Configuration selections are made using the Mode and Set switches located near the
center of the rear panel. (Refer to Figure 2-3 to assist in locating the switches in the
210 series clocks.) The switches are momentary push buttons and are recessed to
prevent accidental actuation. Use a narrow, blunt-tipped object (such as a “Q”-tip) to
actuate the push button switches.
In the event of a power failure, configuration selections are permanently saved in
EEPROM.
1's seconds
10's seconds
1's minutes
10's minutes
1's hours
10's hours
RF meter Set
19
Mode
21
22
23
20
12/24 hour
brightness
exit data set
1001-1000-0706
Rev D
10
Mode
12
13
15
14
11
Set
1100's group
3
4
6
5
210's group
1's group
100's sub-grp
1's sub-grp
10's sub-grp
17
18
Mode
8
9buzzer
716
Mode
-
+
Power +12 VDC
Set
MODE SWITCH FUNCTION CHART
10's kHz
100's kHz
1's MHz
100's MHz
1's kHz
Set
10's MHz
Depress Mode switch one time each to scroll through selections
shown in chart above. Depress Set switch to scroll through
numbers indicated on face of clock. Refer to manual for a more
comprehensive description of "Mode" and "Set" switch functions.
RS-485
+ - G G-+
RS-485
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following
two conditions: (1) This device may not cause
harmful interference, and (2) This device must
accept any interference received, including
interference that may cause undesired
operation. 1001-1000 -0708 Rev B
#8-32 THREADED MOUNTING
HOLES FOR BULKHEAD
MOUNTING.
#8-32 THREADED MOUNTING
HOLES FOR BULKHEAD
MOUNTING.
MOUNTING SLOTS FOR
WALL MOUNTING
Figure 2-3: TimeView 210W Rear Panel
The Mode and Set switches are used in a manner similar to setting a digital alarm clock.
The Mode switch is used to step through each setup parameter and the Set switch
selects the desired variable. The Time and Group parameters are divided into several
steps where each variable is set and then advanced to the next step by the Mode
switch. The digit that is currently being set will flash on and off.
Set
Power +12 VDC
+-
Mode
Exit Data Set
Buzzer
1's Hours
10's Hours
9
1's Seconds
10's Seconds
1's Minutes
10's Minutes
Brightness 100's Group
10's Group
1's Group
100's Sub-Group
1's Sub-Group
10's Sub-Group
Set
MODE SWITCH FUNCTION CHART
Mode
16
7
8
2
5
6
4
3
1Set
11
14
15
13
12
Mode
10
RS-485RS-485 Repeater
+-GG-+In/Out
12/24 Hour
This manual suits for next models
7
Table of contents
Other Spectracom Clock manuals

Spectracom
Spectracom NetClock User guide

Spectracom
Spectracom TimeView 400 8177 User manual

Spectracom
Spectracom EPSILON EC1S User manual

Spectracom
Spectracom TimeView 230 User manual

Spectracom
Spectracom 8183A NETCLOCK User manual

Spectracom
Spectracom 9289 User manual

Spectracom
Spectracom 9183 User manual
Popular Clock manuals by other brands

Junghans
Junghans MAX BILL Series manual

Conrad Electronic
Conrad Electronic Weather Direct operating instructions

Dugena
Dugena 4460960 user manual

Sensorwake
Sensorwake LEXIBOOK CS100 instruction manual

LEXIBOOK
LEXIBOOK COACH LEON instruction manual

Oregon Scientific
Oregon Scientific RM822 instruction manual