Spotlight Fresnel LED 300 Hyperion User manual

Rel. 1.02
Fresnel LED - PC LED
Hyperion 300 White
Manuale utente - User manual

FN HY LED 300 White - PC HY LED 300 White
2
ATTENZIONE: Prima di usare questi apparecchi,
leggere attentamente le istruzioni che seguono.
Spotlight srl non potrà essere ritenuta responsabile di
danni derivanti dalla non osservanza di dette istruzioni.
SAFETY WARNING: Before using this product,
read the present instructions carefully.
Spotlight srl will not be responsible for damage
resulting from instructions not being followed.
6
7
9
10
5
11
12
2
1
4
3
8
Fig. 1
Fig. 2
Display con pulsanti Menu - Display with Menu buttons
DMX SETTINGS
OPTIONS
INFO
SETTINGS

FN HY LED 300 White - PC HY LED 300 White
3
425
295 480 570
470
295
9,8 Kg.
Dimensioni (mm) e peso - Dimensions (mm) and weight
CONSOLE
100-240V
DMX THRU
DMX IN
OUT
IN
OUT
IN
OUT
IN
DMX IN
DMX THRU DMX IN
DMX THRU
Fig. 3
Connessioni elettriche e DMX - Electrical and DMX connections
8,6 Kg.
Fresnel LED 300 Hyperion PC LED 300 Hyperion

FN HY LED 300 White - PC HY LED 300 White
4
CONNESSIONI ELETTRICHE
Il vostro faro è stato progettato per una tensione di
alimentazione da 100 a 240V, 50/60 Hz.
Prima e durante l’installazione osservare le seguenti
norme:
• Verificare sempre l’efficienza del collegamento a terra
della linea in uso.
• Verificare che la tensione di alimentazione corrisponda a
quella dell’apparecchio
• L’apparecchio è previsto per uso all’interno: pertanto
deve essere protetto dall’umidità e dalla pioggia se
usato in condizioni diverse (IP 20).
PUNTAMENTO
Tramite la maniglia laterale ②si può allentare il
bloccaggio del faro in una certa posizione e modificare
la sua inclinazione. Lo stesso si può fare riguardo alla
rotazione sull’asse verticale, facendolo ruotare sul perno
di aggancio.
Per la regolazione dello zoom ruotare in senso orario o
antiorario il pomello ⑪, rispettivamente per stringere o
allargare il fascio luminoso.
MANUTENZIONE
Non aprire l’apparecchio. La manutenzione deve essere
eseguita esclusivamente dal costruttore o dal suo
servizio di assistenza.
Sottoporre il faro a revisione almeno una volta all’anno
per controllare l’integrità delle parti elettriche e
meccaniche e l’aggiornamento del software.
RICICLAGGIO
Il prodotto deve essere riciclato o smaltito
secondo la direttiva 2002/96/CE
DESCRIZIONE DEL PROIETTORE
Riferendosi ai disegni di pag. 2:
① Staffa di sospensione
②Maniglia per regolazione inclinazione del faro
③Guide porta accessori
④Guida di bloccaggio e rilascio accessori
⑤Display e pulsanti menu
⑥Connettore DMX THRU
⑦Connettore DMX IN
⑧Fusibile
⑨ Alimentazione OUT (connettore Powercon)
⑩ Alimentazione IN (connettore Powercon)
⑪ Pomolo per regolazione dello zoom
⑫ Manopola di regolazione intensità luminosa
(in modalità Potenziometro Locale)
INDICAZIONI GENERALI
Il proiettore in Vs possesso risponde alle Direttive
Europee 2006/95/CE, 2004/108/CE e 2011/65/UE.
La targhetta che è sistemata sul fianco del proiettore,
contiene le seguenti informazioni:
• Modello
• Tensione di alimentazione in V
• Potenza in W
• Indice di protezione IP
• Massima temperatura ambiente ammissibile in °C
INSTALLAZIONE
• Il proiettore è progettato esclusivamente per impiego
professionale.
• Non puntare il faro direttamente negli occhi
• Si prega di prestare la dovuta attenzione alle note
riportate sull’etichetta dell’apparecchio.
• Ricordarsi di collegare la fune di sicurezza se previsto
dalle norme di sicurezza locali.
• ll proiettore può essere usato sia sospeso sia montato
su cavalletto.
ATTENZIONE: L'APPARECCHIO DEVE
ESSERE COLLEGATO A TERRA
ATTENZIONE: L'APPARECCHIO NON DEVE
ESSERE COLLEGATO A UN DIMMER

FN HY LED 300 White - PC HY LED 300 White
5
MODALITA' DI FUNZIONAMENTO
Il faro è predisposto per poter essere utilizzato in diverse
modalità di funzionamento:
• POTENZIOMETRO LOCALE
• DMX (Wireless opzionale)
• RDM
CONTROLLO DELLA LUMINOSITA' IN FUNZIONE
DELLA TEMPERATURA
L’apparecchio è dotato di un controllo della temperatura
del LED e della scheda driver, che per evitare un
deterioramento anticipato in caso di sovratemperatura
regola l’intensità luminosa.
PRIORITA' INGRESSI
La priorità di ingresso viene data:
- in assenza di segnale DMX, sarà attivo il valore
impostato con il potenziometro
- in presenza di segnale DMX verrà seguito il relativo
segnale e verrà ignorato il potenziometro
- se il segnale DMX viene tolto o perso, viene mantenuto
il livello impostato da DMX fino a quando non si agisce
sul potenziometro, che imposterà il nuovo valore.
MENU
All’accensione viene visualizzata la versione software
installata, a cui fa seguito la visualizzazione delle
impostazioni di default, ovvero la Modalità di
Funzionamento attualmente impostata.
Se il faro è comandato dal dmx, il display dopo 3 secondi
mostra una videata con modo e indirizzo dmx.
Altrimenti mostra lo stato del potenziometro:
LEGENDA
SETUP
BACK
PREV
NEXT
ENTER
Premendo il tasto setup si accede alle impostazioni e si
naviga attraverso i sottomenu agendo sui pulsanti NEXT
e PREV che in presenza di voci di tipo valore avranno la
funzione di modifica in aumento (+) o diminuzione (-)
dei valori stessi; le modifiche potranno essere confermate
con il pulsante ENTER o annullate con il pulsante BACK.
Struttura del menu - MENU GENERALE
Voce Valori Def Descrizione
DMX SETTINGS Sottomenu impostazioni dmx
OPTIONS Sottomenu configurazioni
opzionali
INFO Sottomenu informazioni
MENU DMX SETTING
Voce Valori Def Descrizione
DMX
ADDRESS
1 .. xxx
il valore massimo
dipende dalla
personality
1 Indirizzo dmx
DMX
PERSONALITY
8 bit - 3CH
16bit - 6CH
8 bit - 1CH
8 bit - 3CH Modo dmx
WIRELESS
DMX Opzionale
Impostazioni
gestione
wireless dmx
SETUP
8 bit - 3CH
001
SETUP
MANUAL
Dimmer 18%
DMX SETTINGS
OPTIONS
INFO
SETTINGS

FN HY LED 300 White - PC HY LED 300 White
6
MENU DMX SETTING - WIRELESS DMX
Voce Valori Def Descrizione
ACTIVATION ON / OFF OFF Accende/spegne il modulo
di ricezione wireless DMX
UNLINK Enter to Unlink
Esc to Exit
Consente di rimuovere
l’associazione tra il faro e il
trasmettitore wireless dmx
MENU OPTIONS
Voce Valori Def Descrizione
LED DELAY OFF / 30, 60...600
ms 240 ms
Tempo di ritardo
del LED. Questo
parametro è ignorato
se si seleziona una
personality che
contiene il canale
“Delay”.
DIMMING
CURVE
LINEAR
QUADRATIC
HALO
QUADRATIC Correzione Gamma
OUT
FREQUENCY
500, 800,
1000,1500...
10000,11000,
12000...20000 Hz
1000 Hz Frequenza PWM LED
FAN MODE
(*)
AUTO
STANDARD
SILENT
AUTO
Seleziona la modalità
di funzionamento
della ventola. Per
alcuni modi dmx
questo valore è
ignorato. Si veda
apposito paragrafo
DISPLAY
ROTAT.
STANDARD
ROTATED STANDARD
Rotazione di 180° del
display. Standard =
tasti a destra del
display.
DISPLAY
STANDBY
OFF
ON OFF
Selezionando ON
il display si spegne
automaticamente
dopo 60 secondi di
inutilizzo
DEFAULT
SET
Imposta il default
per tutti i parametri
utente
FACTORY
SETTING Riservato al Costruttore Impostazioni di
fabbrica
(*)
Fan Mode
Vi sono tre modalità di controllo ventole. L’utente può
scegliere la modalità tramite il MENU OPTIONS.
1) modalità AUTO: le ventole sono regolate
automaticamente in base alla temperatura del LED.
2) modalità STANDARD: le ventole sono mantenute
sempre al valore predefinito.
3) modalità SILENT: le ventole sono mantenute sempre al
valore minimo.
MENU INFO
Voce Valori Descrizione
LED TEMPERAT. 25°C Temperatura sul LED
LED TIME Xx Hr - xx Mn Ore funzionamento LED
UNIT TIME Xx Hr - xx Mn Ore funzionamento
apparecchio
SOFTWARE VERS. V. ....
Data di rilascio
Visualizza versione
software
MODALITA' POTENZIOMETRO LOCALE
In questa modalità è possibile regolare l’intensità luminosa
agendo sul potenziometro ⑫“DIMMER”.

FN HY LED 300 White - PC HY LED 300 White
7
MODALITA' DMX
Il modo dmx è selezionabile dal menu DMX SETTINGS.
Segue l’elenco dei modi dmx con la descrizione dei canali.
8 bit - 3CH
Ch Nome Valore DMX
1 DIMMER 0..255 Da spento (0) a full (255)
2 STROBE - vedere apposito paragrafo -
3 SERVICE - vedere apposito paragrafo -
16 bit - 6CH
Ch Nome Valore DMX
1 DIMMER 0..255 Da spento (0) a full (255)
2DIMMER
FINE 0..255 Da spento (0) a full (255)
3 DELAY
0..45 NON ATTIVO - Il delay è quello
impostato a display
46..55 0 ms
56..65 30 ms
66..75 60 ms
76..85 90 ms
86..95 120 ms
96..105 150 ms
106..115 180 ms
116..125 210 ms
126..135 240 ms
136..145 270 ms
146..155 300 ms
156..165 330 ms
166..175 360 ms
176..185 390 ms
186..195 420 ms
196.205 450 ms
206..215 480 ms
216..225 510 ms
226..235 540 ms
236..245 570 ms
246.255 600 ms
4 FAN 0..255
Ventola da velocità MINIMA a
STANDARD (valori in Volt impostabili
in menu Factory Setting)
4 STROBE - vedere apposito paragrafo -
5 SERVICE - vedere apposito paragrafo -
8 bit - 1CH
Ch Nome Valore DMX
1 DIMMER 0..255 Da spento (0) a full (255)
CANALE STROBE
valido in tutte le modalità DMX in cui è previsto
Ch Nome Valore DMX
xx STROBE
0 STROBO NON ATTIVO
1..200 Strobo da lento (3,86 s.) a veloce
(30 ms)
201..225 OFF
226..230
Abilitazione comando SERVICE
(impostazione di un parametro del
faro, e attendere per 5 sec.)
231..255 OFF

FN HY LED 300 White - PC HY LED 300 White
8
Service - Modalità di salvataggio di una
impostazione
1. Selezionare l’impostazione che si desidera effettuare
tramite il canale SERVICE
2. Portare il canale STROBE nella fascia SERVICE - il faro
si accende a FULL WHITE
3. Rimanere in attesa per 5 secondi
4. Tre lampeggi confermano che l’operazione è stata
portata a termine.
RDM
Il presente dispositivo supporta il protocollo RDM, ultima
versione (ANSI E1.20 - 2010). Vengono supportati i
seguenti parametri:
Denominazione Plasa/ESTA Numero Canali
DEVICE_INFO Lettura dei seguenti parametri:
- Versione protocollo RDM
- Device Model ID
- Categoria prodotto
- ID versione sw
- Numero di canali DMX
- Indice modalità DMX
- Indirizzo DMX
- Numero di sub-devices
- Numero di sensori
IDENTIFY_DEVICE Accensione dei LED per consentire di
individuare visivamente il dispositivo
DMX_START_ADDRESS Impostazione/lettura Indirizzo DMX
SOFTWARE_VERSION_LABEL Descrizione testuale versione sw
SUPPORTED_PARAMETERS Elenco dei parametri supportati
DMX_PERSONALITY Impostazione modalità DMX
DMX_PERSONALITY_
DESCRIPTION
Ottenimento descrizione testuale
modalità DMX
DEVICE_MODEL_DESCRIPTION Descrizione testuale del device model
MANUFACTURER_LABEL Descrizione testuale manufacturer
SENSOR_DEFINITION,
SENSOR_VALUE
Visualizzazione dei valori letti dal
sensore di temperatura, espresso in
decimi di grado Celsius
CANALE SERVICE
valido se canale dmx STROBE in fascia SERVICE
Ch Nome Valore DMX
xx SERVICE
0..5 INACTIVE
6..11 LED DELAY OFF
12..17 LED DELAY 30ms
18..23 LED DELAY 60ms
24..29 LED DELAY 120ms
30..35 LED DELAY 180ms
36..41 LED DELAY 240ms
42..47 LED DELAY 300ms
48..53 LED DELAY 360ms
54..59 LED DELAY 420ms
60..65 LED DELAY 480ms
66..71 LED DELAY 600ms
72..77 CURVE LINEAR
78..83 CURVE QUADRATIC
84..89 FREQUENCY 500Hz
90..95 FREQUENCY 800Hz
96..101 FREQUENCY 1000Hz
102..107 FREQUENCY 1500Hz
108..113 FREQUENCY 3000Hz
114..119 FREQUENCY 5000Hz
120..125 FREQUENCY 10000Hz
126..131 FREQUENCY 15000Hz
132..137 FREQUENCY 20000Hz
138..143 LED BOOST ON
144.149 LED BOOST OFF
150..155 FAN MODE AUTO
156..161 FAN MODE STANDARD
162..167 FAN MODE SILENT
168..173 DISPLAY STANDARD
174..179 DISPLAY ROTATED
180..185 DISPLAY OFF
186..191 DISPLAY ON
192..197 NO FUNCTION
198..203 DEFAULT SET
204..255 FREE - INACTIVE

FN HY LED 300 White - PC HY LED 300 White
9

FN HY LED 300 White - PC HY LED 300 White
10
DESCRIPTION OF THE LUMINAIRE
Referring to figures on pages 2-3:
①Suspension yoke
②Handle for tilt regulation
③Accessory guides
④Accessory locking and releasing guide
⑤Display and menu buttons
⑥ DMX THRU connector
⑦DMX IN connector
⑧Fuse
⑨Power OUT (Powercon connector)
⑩Power IN (Powercon connector)
⑪Zoom adjustment knob
⑫ Light intensity adjustment knob
(in Local Potentiometer mode)
INTRODUCTION
The luminaire you have bought complies to 2006/95/EC,
2004/108/EC and 2011/65/EU European Directives.
The label on the side of the luminaire lists the following
information:
• Model
• Mains supply voltage (V)
• Lamp wattage (W)
• Protection index (IP)
• maximum allowed ambient temperature in °C
INSTALLATION
• The luminaire has been designed for professional use
only
• Do not direct the light beam straight into somebody’s
eyes
• Read carefully the information label on the side of the
luminaire
• Remember to connect the safety cable, if required by
local health and safety regulations
• The luminaire can be either suspended or mounted on
a stand.
ELECTRICAL CONNECTIONS
The luminaire has been designed to operate with a 100V
to 240V supply, 50-60Hz.
Before and during the installation, make sure you follow
the guidelines below:
• Always check the earth continuity connection for the
line being used.
• Ensure the required voltage of the unit is the same as
the supplied one.
• The unit is designed for indoor use: if it is to be used
outdoor, ensure it is protected from dampness and
rain. (IP 20)
FOCUSING
Using the handle on the side ②it is possible to loosen
the luminaire when it is locked in a certain position and
thus change its inclination. You can rotate the luminaire
on the vertical axis by rotating it on its hook clamp.
The zoom is adjusted with the knob ⑪by widening or
narrowing the light beam.
MAINTENANCE
Do not open the fixture. Maintenance should be performed
only by the manufacturer or by its service agent.
The luminaire must be serviced at least once a year, to
check the integrity of its electrical and mechanical parts
and to keep software updated.
RECYCLING
The product must be recycled or disposed of,
according to Directive 2002/96/CE.
WARNING: THIS UNIT MUST NOT BE
CONNECTED TO A DIMMER
WARNING: THE LUMINAIRE MUST
ALWAYS BE EARTHED

FN HY LED 300 White - PC HY LED 300 White
11
OPERATING MODE
The luminaire is designed to be used in different
operating modes:
• LOCAL POTENTIOMETER
• DMX (Wireless optional)
• RDM
LIGHT OUTPUT CONTROL DEPENDING ON THE
TEMPERATURE
The fixture is equipped with a temperature control of the
LED and of the driver motherboard, which, to avoid an
early deterioration in case of overtemperature, regulates
the light intensity.
INPUTS PRIORITIES
Input priority is given:
- in absence of the DMX signal, the value set with the
potentiometer will be active
- when there is the DMX signal the relevant signal is
followed and the potentiometer will be ignored
- if the DMX signal is eliminated or lost, the DMX set
level is kept until you act on the potentiometer, which
will set the new value.
MENU
When switched on, the installed software version is
displayed, followed by the display of the default settings,
ie the currently set operating mode.
If the luminaire is DMX controlled, after 3 seconds the
display will show the mode and DMX address
Otherwise it will show the potentiometers status:
LEGENDA
SETUP
BACK
PREV
NEXT
ENTER
Pressing the SETUP key you access the settings and
browse through the submenus by pressing the NEXT and
PREV buttons, which in case of value type entries will
have the function of increasing (+) or decreasing (-)
the values; the changes can be confirmed with the ENTER
button or canceled with the BACK button.
MENU STRUCTURE - MAIN MENU
Item Value Def Description
DMX SETTINGS Dmx settings submenu
OPTIONS Optional settings submenu
INFO Information submenu
MENU DMX SETTING
Item Value Def Description
DMX
ADDRESS
1 .. xxx
il massimo dipende
dalla personality
1 Dmx address
DMX
PERSONALITY
8 bit - 3CH
16 bit - 6CH
8 bit - 1CH
8 bit - 3CH Dmx mode
WIRELESS
DMX Optional Wireless dmx
setting submenu
DMX SETTINGS
OPTIONS
INFO
SETTINGS
SETUP
8 bit - 3CH
001
SETUP
MANUAL
Dimmer 18%

FN HY LED 300 White - PC HY LED 300 White
12
(*) Fan Mode
There are three fan control modes. The user can choose
the mode via the OPTIONS MENU.
1) AUTO mode: the fans are automatically adjusted based
on the LED temperature.
2) STANDARD mode: the fans are always kept at the
default value.
3) SILENT mode: the fans are always kept at the minimum
value.
MENU INFO
Item Value Description
LED TEMPERAT. 25°C LED temperature
LED TIME Xx Hr – xx min LED operation time
UNIT TIME Xx Hr – xx min Unit operation time
SOFTWARE VERSION V. ....
Release date
It displays the
software version
LOCAL POTENTIOMETER MODE
In this mode you can adjust the light intensity using the
potentiometer ⑫“DIMMER”.
MENU DMX SETTING - WIRELESS DMX
Item Value Def Description
ACTIVATION ON / OFF OFF Switch ON/OFF the wireless
DMX module
UNLINK Enter to Unlink
Esc to Exit
To unlink the fixture
from the wireless dmx
transmitter
MENU OPTIONS
Item Value Def Description
LED DELAY OFF / 30,
60...600 ms 240 ms
Delay time on LED
output. This parameter
is ignored when you
select a personality
containing the “Delay”
channel
DIMMING
CURVE
LINEAR
QUADRATIC
HALO
QUADRATIC Gamma Correction
OUT
FREQUENCY
500,
800,1000,1500...
10000,11000,
12000...
20000 Hz
1000 Hz PWM LED frequency
FAN MODE
(*)
AUTO
STANDARD
SILENT
AUTO
Selects the fans
operation mode.
For some dmx modes
this value is ignored.
See the relevant
paragraph
DISPLAY
ROTAT.
STANDARD
ROTATED STANDARD
180° rotation of the
display. Standard =
keys to the right of
the display.
DISPLAY
STANDBY
OFF
ON OFF
By selecting ON the
display turns off
automatically after 60
seconds of inactivity
DEFAULT
SET
It sets the default
for all the user
parameters
FACTORY
SETTING Riservato al Costruttore Factory default setting

FN HY LED 300 White - PC HY LED 300 White
13
DMX MODE
The DMX mode can be selected from the DMX SETTINGS
menu. The DMX mode list with the description of the
channels will follow.
8 bit - 3CH
Ch Name DMX Value
1 DIMMER 0..255 From Off (0) to Full (255)
2 STROBE 0 INACTIVE
1..255 From slow (3,86 s) to fast (30 ms)
16 bit - 5CH
Ch Name DMX Value
1 DIMMER 0..255 From Off (0) to Full (255)
2DIMMER
FINE 0..255 From Off (0) to Full (255)
3 DELAY
0..12 0 ms
13..24 30 ms
25..36 60 ms
37..48 90 ms
49..60 120 ms
61..72 150 ms
73..84 180 ms
85..96 210 ms
97..108 240 ms
109..120 270 ms
121..132 300 ms
133..144 330 ms
145..156 360 ms
157..168 390 ms
169..180 420 ms
181..192 450 ms
193..204 480 ms
205..216 510 ms
217..228 540 ms
229..240 570 ms
241..255 600 ms
4 FAN
Fan from MINIMUM to STANDARD
speed (values in Volts can be set in
the Factory Setting menu)
5 STROBE - See the relevant paragraph -
6 SERVICE - See the relevant paragraph -
8 bit - 1CH
Ch Name DMX Value
1 DIMMER 0..255 From Off (0) to Full (255)
STROBE CHANNEL
valid in all the DMX modes where it is foreseen
Ch Name DMX Value
xx STROBE
0 INACTIVE STROBO
1..200 Strobo from slow (3,86 s.) to fast
(30 ms)
201..225 OFF
226..230
Fixture ON at the set colour
Enabling SERVICE 1 control (set of
a custom preset, and keep on hold
for 5 secs.)
231..255 OFF

FN HY LED 300 White - PC HY LED 300 White
14
Service - Saving mode of a setup
1. Select the setup you wish to perform through the
SERVICE channel
2. Move the ADVANCED STROBO channel to the
SERVICE area - the luminaire switches on at FULL
WHITE
3.
Keep on hold for 5 secs.
4. Three flashes confirm that the operation was
completed
RDM
This fixture supports the RDM protocol, latest version
(ANSI E1.20 - 2010). The following parameters are
supported:
Plasa/ESTA Denomination Number of Channels
DEVICE_INFO Reading of the following parameters:
- RDM protocol version
- Device Model ID
- Product category
- ID version sw
- Number of DMX channels
- DMX mode index
- DMX address
- Number of sub-devices
- Number of sensors
IDENTIFY_DEVICE LEDs power on to allow to visually
identify the fixture
DMX_START_ADDRESS DMX address setting/reading
SOFTWARE_VERSION_LABEL Text description version sw
SUPPORTED_PARAMETERS List of supported parameters
DMX_PERSONALITY DMX mode setting
DMX_PERSONALITY_
DESCRIPTION
Obtaining textual description of
DMX mode
DEVICE_MODEL_DESCRIPTION Text description of the device model
MANUFACTURER_LABEL Text description manufacturer
SENSOR_DEFINITION,
SENSOR_VALUE
Display of the values read by the
temperature sensor, expressed in
tenths of Celsius degree
CANALE SERVICE
valid if dmx channel STROBE is on SERVICE area
Ch Name DMX value
xx SERVICE
0..5 INACTIVE
6..11 LED DELAY OFF
12..17 LED DELAY 30ms
18..23 LED DELAY 60ms
24..29 LED DELAY 120ms
30..35 LED DELAY 180ms
36..41 LED DELAY 240ms
42..47 LED DELAY 300ms
48..53 LED DELAY 360ms
54..59 LED DELAY 420ms
60..65 LED DELAY 480ms
66..71 LED DELAY 600ms
72..77 CURVE LINEAR
78..83 CURVE QUADRATIC
84..89 FREQUENCY 500Hz
90..95 FREQUENCY 800Hz
96..101 FREQUENCY 1000Hz
102..107 FREQUENCY 1500Hz
108..113 FREQUENCY 3000Hz
114..119 FREQUENCY 5000Hz
120..125 FREQUENCY 10000Hz
126..131 FREQUENCY 15000Hz
132..137 FREQUENCY 20000Hz
138..143 LED BOOST ON
144.149 LED BOOST OFF
150..155 FAN MODE AUTO
156..161 FAN MODE STANDARD
162..167 FAN MODE SILENT
168..173 DISPLAY STANDARD
174..179 DISPLAY ROTATED
180..185 DISPLAY OFF
186..191 DISPLAY ON
192..197 NO FUNCTION
198..203 DEFAULT SET
204..255 FREE - INACTIVE

FN HY LED 300 White - PC HY LED 300 White
15

FN HY LED 300 White - PC HY LED 300 White
Spotlight s.r.l.
Via Sardegna 3
20098 S. Giuliano Milanese
Milano - Italy
Tel. +39.02.98830.1
Fax +39.02.98830.22
E-mail: [email protected]
www.spotlight.it
This manual suits for next models
2
Table of contents
Languages:
Other Spotlight Floodlight manuals
Popular Floodlight manuals by other brands

Straits Lighting
Straits Lighting SL923FLF-15W Installation instructions manual

Westgate
Westgate LFX-XS-15W K Series Installation instructions manual

hylite
hylite Mightylite Pro MLP240B Installation & operating instructions

silversun
silversun PRO SPORT FLS50CW installation guide

brennenstuhl
brennenstuhl 1172660 operating manual

Cameo
Cameo OPUS S5 user manual