SRS Labs FB 1650 TLT FT User manual

SunRise Solar-Powered Attic Fan
Flat Base Unit
Installation Guide
Model Shown: # FB1050
Available Models:
FB850FT, FB1050FT, FB1250FT, FB1600FT
For sloped, shingled roofs.
Made in the USA
SunRise Solar Inc.
P.O. Box 53
St. John, IN 46373
219-558-2211
219-306-4571 fax
www.SunRiseSolar.com
SunRise Solar-Powered Attic Fan
Flat Base Unit
Installation Guide
Model Shown: # FB1050
Available Models:
FB850FT, FB1050FT, FB1250FT, FB1600FT
For sloped, shingled roofs.
Made in the USA
SunRise Solar Inc.
P.O. Box 53
St. John, IN 46373
219-558-2211
219-306-4571 fax
www.SunRiseSolar.com
Fixed Thermostat Information
This fan has been factory equipped with a thermal on/off switch. This switch is
designed to turn the fan:
ON: 80° F
OFF: 65° F
(+/-7°)
Example: Attic temperature rises to 80° and fan turns on. Once it cools to 65° the fan
will shut off. If evening comes and temp does not fall below 65° to reset the switch,
then the unit will start the next morning at sunrise and continue to cool the attic.
However, if the attic temp falls below 65° at night, then the switch will shut off and
will not turn the unit on again until attic temp reaches 80°.
INSTALLER: THIS FAN WILL NOT RUN UNLESS THE AMBIENT (AIR)
TEMPERATURE IS AT OR NEAR 80°. YOU MAY TEST OPERATION OF THE
THERMOSTAT BY BLOWING WARM AIR DIRECTLY ON THE THERMOSTAT TO
HEAT IT TO 80°, MAKING SURE SOLAR PANEL IS EXPOSED TO SUNLIGHT AT
THE SAME TIME.
SunRise Solar Inc.
P.O. Box 53
St. John, IN 46373
219-558-2211
219-306-4571 fax
www.SunRiseSolar.com
Solar Attic Fans.....made in the USA!
SunRise Solar-Powered Attic Fan
Flat Base Unit w/Tilting Solar Panel
Installation Guide
Available Models:
FB1600 TLT FT
For normal sloped, shingled roofs.
Made in the USA
Fixed Thermostat Information
This fan has been factory equipped with a thermal on/off switch. This switch is
designed to turn the fan:
ON: 80° F
OFF: 65° F
(+/-7°)
Example: Attic temperature rises to 80° and fan turns on. Once it cools to 65° the fan
will shut off. If evening comes and temp does not fall below 65° to reset the switch,
then the unit will start the next morning at sunrise and continue to cool the attic.
However, if the attic temp falls below 65° at night, then the switch will shut off and
will not turn the unit on again until attic temp reaches 80°.
INSTALLER: THIS FAN WILL NOT RUN UNLESS THE AMBIENT (AIR)
TEMPERATURE IS AT OR NEAR 80°. YOU MAY TEST OPERATION OF THE
THERMOSTAT BY BLOWING WARM AIR DIRECTLY ON THE THERMOSTAT TO
HEAT IT TO 80°, MAKING SURE SOLAR PANEL IS EXPOSED TO SUNLIGHT AT
THE SAME TIME.
SunRise Solar Inc.
P.O. Box 53
St. John, IN 46373
219-558-2211
219-306-4571 fax
www.SunRiseSolar.com
Solar Attic Fans.....made in the USA!
SunRise Solar-Powered Attic Fan
Flat Base Unit w/Tilting Solar Panel
Installation Guide
Available Models:
FB1600 TLT FT
For normal sloped, shingled roofs.
Made in the USA
FLAT BASE UNIT INSTALLATION
NOTE: For best operation, install solar fan where it will receive direct sunlight. South or
West facing roof slopes will work best.
1.) Cut a 14 1/2" diameter hole between
rafters approximately 24”-30" down from
roof peak to center of hole.
2.) Trim away top rows of shingles an
additional 2" to allow base flashing to
slip under top rows of shingles and over
bottom rows.
3.) Slip the flat base under the top rows of
shingles and center unit over opening
with the SRS Logo on the bottom.
4.) Gently lift the unit and apply sealant
under lower edge and sides of base
flashing.
5.) Pre-drill (4) mounting holes along the
bottom edge of the base flashing, and
(1) hole on each side approximately 2"
up from the bottom edge.
6.) Use exterior-grade screws to secure unit
to roof deck. Apply sealant to screw heads.
DO NOT OVER-TIGHTEN SCREWS
SunRise Solar Inc.
P.O. Box 53
St. John, IN 46373
219-558-2211
219-306-4571 fax
www.SunRiseSolar.net
Fixed Thermostat Information
This fan has been factory equipped with a thermal on/off switch. This switch is
designed to turn the fan:
ON: 80° F
OFF: 65° F
(+/-7°)
Example: Attic temperature rises to 80° and fan turns on. Once it cools to 65° the fan
will shut off. If evening comes and temp does not fall below 65° to reset the switch,
then the unit will start the next morning at sunrise and continue to cool the attic.
However, if the attic temp falls below 65° at night, then the switch will shut off and
will not turn the unit on again until attic temp reaches 80°.
INSTALLER: THIS FAN WILL NOT RUN UNLESS THE AMBIENT (AIR)
TEMPERATURE IS AT OR NEAR 80°. YOU MAY TEST OPERATION OF THE
THERMOSTAT BY BLOWING WARM AIR DIRECTLY ON THE THERMOSTAT TO
HEAT IT TO 80°, MAKING SURE SOLAR PANEL IS EXPOSED TO SUNLIGHT AT
THE SAME TIME.
SunRise Solar Attic Fans
www.SunRiseSolar.com
For sloped, shingled roofs.
FB 1650 TLT FT

FLAT BASE UNIT INSTALLATION
NOTE: For best operation, install solar fan where panel can be adjusted to receive the
most direct sunlight.
1.) Cut a 14 1/2" diameter hole between
rafters approximately 28”-32" down from
roof peak to center of hole.
2.) Trim away top rows of shingles an
additional 2" to allow base flashing to slip
under top rows of shingles and over
bottom rows.
3.) Slip the flat base under the top rows of
shingles and center unit over opening
with the SRS Logo on the bottom.
4.) Gently lift the unit and apply sealant
under lower edge and sides of base
flashing.
5.) Pre-drill (4) mounting holes along the
bottom edge of the base flashing, and (1)
hole on each side approximately 2" up
from the bottom edge.
6.) Use exterior-grade screws to secure unit
to roof deck. Apply sealant to screw
heads.
7.) After installing your SunRise Solar Fan,
it should look like this.
28” to 32”
1
2
3
4
5
7
8.) Remove the 7/16" nut & bolt from each
support bracket to allow panel to be tilted
to desired position.
9.) Tilt panel so it will receive the most
direct sunlight.
10.) Replace the 7/16" nuts and bolts to
lock solar panel in position.
11.) The installation is now complete!
8
9
10
11
FLAT BASE UNIT INSTALLATION
NOTE: For best operation, install solar fan where panel can be adjusted to receive the
most direct sunlight.
1.) Cut a 14 1/2" diameter hole between
rafters approximately 28”-32" down from
roof peak to center of hole.
2.) Trim away top rows of shingles an
additional 2" to allow base flashing to slip
under top rows of shingles and over
bottom rows.
3.) Slip the flat base under the top rows of
shingles and center unit over opening
with the SRS Logo on the bottom.
4.) Gently lift the unit and apply sealant
under lower edge and sides of base
flashing.
5.) Pre-drill (4) mounting holes along the
bottom edge of the base flashing, and (1)
hole on each side approximately 2" up
from the bottom edge.
6.) Use exterior-grade screws to secure unit
to roof deck. Apply sealant to screw
heads.
7.) After installing your SunRise Solar Fan,
it should look like this.
28” to 32”
1
2
3
4
5
7
8.) Remove the 7/16" nut & bolt from each
support bracket to allow panel to be tilted
to desired position.
9.) Tilt panel so it will receive the most
direct sunlight.
10.) Replace the 7/16" nuts and bolts to
lock solar panel in position.
11.) The installation is now complete!
8
9
10
11
FLAT BASE UNIT INSTALLATION
NOTE: For best operation, install solar fan where it will receive direct sunlight. South or
West facing roof slopes will work best.
1.) Cut a 14 1/2" diameter hole between
rafters approximately 24”-30" down from
roof peak to center of hole.
2.) Trim away top rows of shingles an
additional 2" to allow base flashing to
slip under top rows of shingles and over
bottom rows.
3.) Slip the flat base under the top rows of
shingles and center unit over opening
with the SRS Logo on the bottom.
4.) Gently lift the unit and apply sealant
under lower edge and sides of base
flashing.
5.) Pre-drill (4) mounting holes along the
bottom edge of the base flashing, and
(1) hole on each side approximately 2"
up from the bottom edge.
6.) Use exterior-grade screws to secure unit
to roof deck. Apply sealant to screw heads.
DO NOT OVER-TIGHTEN SCREWS
SunRise Solar Inc.
P.O. Box 53
St. John, IN 46373
219-558-2211
219-306-4571 fax
www.SunRiseSolar.net
Fixed Thermostat Information
This fan has been factory equipped with a thermal on/off switch. This switch is
designed to turn the fan:
ON: 80° F
OFF: 65° F
(+/-7°)
Example: Attic temperature rises to 80° and fan turns on. Once it cools to 65° the fan
will shut off. If evening comes and temp does not fall below 65° to reset the switch,
then the unit will start the next morning at sunrise and continue to cool the attic.
However, if the attic temp falls below 65° at night, then the switch will shut off and
will not turn the unit on again until attic temp reaches 80°.
INSTALLER: THIS FAN WILL NOT RUN UNLESS THE AMBIENT (AIR)
TEMPERATURE IS AT OR NEAR 80°. YOU MAY TEST OPERATION OF THE
THERMOSTAT BY BLOWING WARM AIR DIRECTLY ON THE THERMOSTAT TO
HEAT IT TO 80°, MAKING SURE SOLAR PANEL IS EXPOSED TO SUNLIGHT AT
THE SAME TIME.
FLAT BASE UNIT INSTALLATION
NOTE: For best operation, install solar fan where it will receive direct sunlight. South or
West facing roof slopes will work best.
1.) Cut a 14 1/2" diameter hole between
rafters approximately 24”-30" down from
roof peak to center of hole.
2.) Trim away top rows of shingles an
additional 2" to allow base flashing to
slip under top rows of shingles and over
bottom rows.
3.) Slip the flat base under the top rows of
shingles and center unit over opening
with the SRS Logo on the bottom.
4.) Gently lift the unit and apply sealant
under lower edge and sides of base
flashing.
5.) Pre-drill (4) mounting holes along the
bottom edge of the base flashing, and
(1) hole on each side approximately 2"
up from the bottom edge.
6.) Use exterior-grade screws to secure unit
to roof deck. Apply sealant to screw heads.
DO NOT OVER-TIGHTEN SCREWS
SunRise Solar Inc.
P.O. Box 53
St. John, IN 46373
219-558-2211
219-306-4571 fax
www.SunRiseSolar.net
Fixed Thermostat Information
This fan has been factory equipped with a thermal on/off switch. This switch is
designed to turn the fan:
ON: 80° F
OFF: 65° F
(+/-7°)
Example: Attic temperature rises to 80° and fan turns on. Once it cools to 65° the fan
will shut off. If evening comes and temp does not fall below 65° to reset the switch,
then the unit will start the next morning at sunrise and continue to cool the attic.
However, if the attic temp falls below 65° at night, then the switch will shut off and
will not turn the unit on again until attic temp reaches 80°.
INSTALLER: THIS FAN WILL NOT RUN UNLESS THE AMBIENT (AIR)
TEMPERATURE IS AT OR NEAR 80°. YOU MAY TEST OPERATION OF THE
THERMOSTAT BY BLOWING WARM AIR DIRECTLY ON THE THERMOSTAT TO
HEAT IT TO 80°, MAKING SURE SOLAR PANEL IS EXPOSED TO SUNLIGHT AT
THE SAME TIME.
Popular Solar Panel manuals by other brands

O.N
O.N 23.8757.15 user manual

REC
REC TwinPeak 2S Mono 72 Series installation instructions

Simplicity
Simplicity 1691526 Operator's manual

KB Racking
KB Racking BarnRack installation manual

Philadelphia Solar
Philadelphia Solar PS-M72 Series Installation & operational manual

SereneLife
SereneLife SLSPNL10 user manual