7
Parts Description
The motor is used to power the pump. It is equipped with a thermal overload protector. If the motor overheats for any
reason, the thermal overload protector will shut it down in order to prevent the motor from being damaged.
Electric Motor
A
The pump compresses the air and discharges it into the tank via the piston that moves up and down in the cylinder.
Air Compressor Pump
B
C
I
J
E
The drain valve is used to remove moisture from the air tank after the compressor is shut off.
Air Tank Drain Valve
K
The tank is where the compressed air is stored.
Air Tank
This valve is used to prevent the compressor from building too much pressure. If the pressure reaches the preset
level of the motor, it will automatically pop open. You can also pull the ring on the valve to open manually.
Safety Valve
D
This switch turns on the compressor and is operated manually.When in the ON position, it allows the compressor
to start up or shut down automatically, without warning, upon air demand.ALWAYS set this switch to OFF when
the compressor is not being used and before unplugging the compressor.
ON/OFF Switch
The regulator is used to adjust the pressure inside the line to the tool that is being used. Turn the knob clockwise to
increase the pressure and counter-clockwise to decrease the pressure.
Air Pressure Regulator
F
G
H
The gauge measures the pressure level of the air that is stored in the tank. It cannot be adjusted by the operator and
it does not indicate the pressure inside the line.
Tank Pressure Gauge
The gauge measures the regulated outlet pressure.
Outlet Pressure Gauge
The outlet is connected to a quick connector which is connecting to air hose.
Quick Coupler
This product is for use on a nominal 120-volt circuit and should be grounded. A cord with a grounding plug as
illustrated must be used. Make sure that the product is connected to an outlet that has the same configuration as
the plug (see Figure 1). No adapter should be used with this product.Check with a licensed electrician if the grounding
instructions are not understood or there is doubt as to whether the product is
properly grounded. Do not modify the plug provided. If it will not fit the outlet,
have the proper outlet installed by a licensed electrician.
Power Cord
Grounded
outlet
Grounding Pin
Plug
Figure 1
DANGER
Improper installation of the grounding plug will result in a risk
of electric shock. If repair or replacement of the cord or plug
is necessary, do not connect the grounding wire to either flat blade
terminal. The grounding wire is in the green outer surface.