STI Exit Stopper STI-6400 Series User manual

- 1 -
Exit Stopper®
STI-6400 Series
Features:
· Alarm helps prevent unauthorized exits/entries through doors.
· Easy to install.
· Select volume, duration and immediate or 15 second delay for arming and trip.
· May be mounted on top, right, left or next to almost any door.
· User can select on-site whether to use an alarm or annunciator.
· Less expensive than heavy horizontal bar type units and practical for all
emergency doors.
· Contact STI for custom applications.

- 2 -
Table of Contents
· Warnings and Cautions ........................................................................................... Page 2
· Warranty Information............................................................................................... Page 2
· Specifications ......................................................................................................... Page 3
1. Dimensions ......................................................................................................... Page 3
2. Polycarbonate..................................................................................................... Page 3
3. Electronics .......................................................................................................... Page 3
4. Remote Horn ...................................................................................................... Page 3
· Circuit Board Set-Up............................................................................................... Page 4
· Terminal Strip Layout............................................................................................... Page 4
· Switch Settings....................................................................................................... Page 4
· Alarm Feature Description....................................................................................... Page 5
· Installation Instructions All Units / STI-6400............................................................. Page 5
· Mounting Options ................................................................................................... Page 6
· STI-6402 Double Door additional install notes....................................................... Page 7
· STI-6403 Remote Horn additional install notes...................................................... Page 7
· STI-6404 Double Door with Remote Horn additional install notes.......................... Page 7
· STI-6405 Exit Stopper with Momentary Reset....................................................... Page 7
Warnings
All units are recommended for indoor use, not for outdoor use. Unit must be tested periodically
to verify the life of battery. STI recommends you change the 9 Volt battery twice a year.
Installer may need to purchase a simple audio-meter, typically available at your local electronics
store, to measure the sound in areas where the alarm is expected to be heard during normal
noise environment. Results from this test may prove it beneficial to purchase additional exit
stopper units. When purchasing a remote unit (STI-6403) you will need to periodically test the
connections to make sure audibles function at a sound level to alert staff. Maximum of three
STI-6403 may be used in parallel.
All specifications and information shown are current as of publication and subject to change
without notice.
Warranty Information
· Three year guarantee against breakage of polycarbonate in normal use (one year on electro
mechanical and electronic components).
· Electronic warranty form at www.sti-usa.com/wc14

- 3 -
Specifications
Polycarbonate Enclosure:
Dimensions 5.375” W x 5.375” H x 2 “ D (137mm x 137mm x 51mm)
Flammability UL94 V-2
Wall Thickness 0.12 in (3.05mm)
Electronics: STI-6403 and STI-6404 - Remote Horn Unit
Power Source 9 VDC operating power* only
Horn Volume at 1 ft. 95 dB low / 105 dB high
Stand by Current 0 A
Alarm Current 50mA at 95 dB/ 200 mA at 105 dB
* Power source for the STI-6403 Remote Horn uses a separate power source from the
STI-6400 alarm. The Remote Horn contains an internal 9 volt battery. Horn operates
when the Form C contact at main unit is activated on alarm.
Electronics: STI-6400 - All Units
9 VDC Alkaline or 9V-24VDC wired
Class II UL Listed transformer
Horn Volume at 1 ft. 95 dB low / 105 dB high
Relay Output Form C Dry Contacts 0-30 VDC or VAC, 1 Amp
Stand by Current 10uA
Alarm Current 130mA at 95 dB / 200mA at 105 dB
Operating Temperature
Range
Power Source
32° to 113°F (0° to 45°C)

- 4 -
Circuit Board Set-up
Figure 1
TERMINAL BLOCK
(SEE BELOW)
FOR COMPLETE ALARM OPTIONS
AND SWITCH SETTINGS SEE CHART
ON REVERSE SIDE.
PC BOARD
JP5
JP2
JP4
JP3
JP7
SWITCH
ALARM
DURATION
ALARM VOLUME SWITCH
TRIP DELAY SWITCH
ARMING SWITCH
)
(FACTORY DEFAULT SETTINGS
(FACTORY DEFAULT SETTINGS)
(ON)
(ON)
(OFF)
(OFF)
(OFF)
TERMINAL BLOCK
FOR COMPLETE ALARM OPTIONS
AND SWITCH SETTINGS SEE CHART
ON REVERSE SIDE.
PC BOARD
JP5
JP2
JP4
JP3
JP7
SWITCH
ALARM
DURATION
ALARM VOLUME SWITCH
TRIP DELAY SWITCH
ARMING SWITCH
)
(FACTORY DEFAULT SETTINGS
(FACTORY DEFAULT SETTINGS)
(ON)
(ON)
(OFF)
(OFF)
(OFF)
Switch Settings
Volume - High (105 dB) at 1 ft. ON*
Volume - Low (95 dB) at 1 ft. OFF
Duration - 30 Second Alarm OFF* OFF*
Duration - 180 Second Alarm OFF ON
Duration - Continuous Alarm ON OFF
Duration - Annunciator Mode ON ON
Trip - Immediate OFF*
Trip - 15 Second Delay ON
Arming - Immediate ON*
Arming - 15 Second Delay OFF
FEATURE JP2 JP3 JP4 JP5 JP7
*Factory Settings
Note: Slide black lever to desired ON/OFF position as labeled on circuit board.
POLYCARBONATE COVER
POLYCARBONATE BASE
120 dB HORN
ALARM DURATION
ALARM TRIP DELAY
EXIT DELAY
VOLUME
VIEW OF THE CIRCUIT BOARD
19039 SCREW
6 x 1 1/4 in.
(2) PROVIDED
19018 ANCHOR
(2) PROVIDED
BOTTOM SURFACE AS SHOWN
WIRES THROUGH NOTCH ON
AND ROUTE REED SWITCH
REMOVE FRONT COVER
VIEW SHOWING MAGNET INSTALLATION
MAGNET
NC COM NO GD V+ RS1 RS2 KEYSW
TERMINAL BLOCK WIRING CONNECTIONS
FORM C
DRY
CONTACTS
REMOTE
POWER
INPUT
9-24 VDC
REED
SWITCH
TERMINALS
KEY SWITCH
TERMINALS
INTERNAL REED SWITCH
(RS1)
ALARM DURATION
ALARM TRIP DELAY
EXIT DELAY
VOLUME
VIEW OF THE CIRCUIT BOARD
MAXIMUM GAP 3/4 in. (19mm)
3/8 in. (9.5mm) ON METAL DOOR
AND FRAME
SPACERS (USE AS NECESSARY)
NOTE: 2 SPACERS UNDER BOTH
MAGNET AND REED SWITCH
MUST BE USED ON STEEL DOORS
4
3
2
1
NC COM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
NC COM NO GD V+ RS1 RS2 KEYSW
4
3
2
1
NC COM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
4
3
2
1
ALARM SOUNDSWHEN DOORIS OPENED
EMERGENCY USE ONLY
ON OFF
NCCOM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
TO KEY
SWITCH
06402 REED SWITCH
(RS2)
OPTIONAL:
TO REMOTE
HORN
STI-6403
TERMINAL BLOCK
VIEW SHOWING INSTALLATION OF
ADDTIONAL REED SWITCH 06402
3/4 in. (19mm)
MAXIMUM GAP
3/8 in. (9.5mm) ON
METAL DOOR AND FRAME
MAGNET ASSEMBLY
(SEE ABOVE FOR INSTALLATION)
DOOR
SWING
6400 SWING
MAGNET
DOOR STOP
MAGNET MUST BE
INSTALLED OPPOSITE
RAISED RIB ON OUTER COVER
19039 SCREW
6 x 1 1/4 in.
(2) PROVIDED
SPACERS - USE
AS NECESSARY
NOTE: (2) SPACERS MUST BE
USED ON STEEL DOORS
19018 ANCHOR
(2) PROVIDED
MAGNET
6400 UNIT
DOOR
SWING
JAM
DOOR STOP
DOOR
TYPICAL FLUSH MOUNT DOOR JAM
INSTALLATION
TYPICAL RECESSED MOUNT DOOR JAM
INSTALLATION

- 5 -
Alarm Feature Description
· Volume Switch JP2 - Sets alarm volume to high 105 dB or low 95 dB.
· Duration Switch JP3 and JP4 - Amount of time alarm sounds after trip. Arming resets at
end of duration if door is closed. Alarm will not reset if in continuous mode; alarm sounds
until battery is drained. Annunciator Mode is a series of 10 short beeps or until door is
closed.
· Trip Delay Switch JP5 - If you wish to ENTER an alarmed door without sounding the horn
immediately, the trip delay will allow 15 seconds for you to enter and de-activate the alarm
with the key switch before the alarm will sound.
· Arming Switch JP7 - This mode is useful when an AUTHORIZED EXIT is required through
alarmed door. In “ON” position immediate arming will set the alarm ready to function as
soon as door is opened. In “OFF” position delay arming will allow 15 seconds for you to exit
through the door without sending alarm signal.
Installation Instructions
1. Make sure key switch is in the OFF
position.
2. Remove tamper screw on side of unit
and remove housing cover. Save this
tool for future servicing and battery
change (Fig. 2).
3. Set switches, on circuit board, to
desired alarm settings (Fig. 1).
4. Test settings by connecting battery
or external power source. If using
external power source a Class II UL
Listed transformer is required. If power
is present at terminal block (Fig. 1) 9V battery
is in no-load on standby power consumption.
5. Mount main unit on or next to door using hardware provided. Reed switch mounting
locations can be moved to one of the four positions shown in Fig. 2. If mounted next to
door, route reed switch wire through knockout in bottom of housing as shown in Fig. 3.
6. Mount magnet on door frame (or door
if unit is mounted next to door) using
screws provided. When mounting on
metal doors or door frames, use plastic
spacers provided. Reed switch and
magnet must be within 3/4” when door
is closed (3/8” on metal door and frame).
Please refer to figures 4, 5 and 6 on page
6 for other mounting options.
7. If installing STI-6402, STI-6403, or
STI-6404 continue to page 7 for more
instructions (Fig. 7 and 8). STI-6402
mounting option is shown on page 6.
8. Replace cover by sliding flanges on
inside of cover into slots on base. Then
rotate the cover over unit and snap close.
Replace tamper screw.
Note: STI recommends setting up unit and testing settings prior to mounting.
Figure 3
POLYCARBONATE COVER
POLYCARBONATE BASE
120 dB HORN
ALARM DURATION
ALARM TRIP DELAY
EXIT DELAY
VOLUME
VIEW OF THE CIRCUIT BOARD
19039 SCREW
6 x 1 1/4 in.
(2) PROVIDED
19018 ANCHOR
(2) PROVIDED
BOTTOM SURFACE AS SHOWN
WIRES THROUGH NOTCH ON
AND ROUTE REED SWITCH
REMOVE FRONT COVER
VIEW SHOWING MAGNET INSTALLATION
MAGNET
NC COM NO GD V+ RS1 RS2 KEYSW
TERMINAL BLOCK WIRING CONNECTIONS
FORM C
DRY
CONTACTS
REMOTE
POWER
INPUT
9-24 VDC
REED
SWITCH
TERMINALS
KEY SWITCH
TERMINALS
INTERNAL REED SWITCH
(RS1)
ALARM DURATION
ALARM TRIP DELAY
EXIT DELAY
VOLUME
VIEW OF THE CIRCUIT BOARD
MAXIMUM GAP 3/4 in. (19mm)
3/8 in. (9.5mm) ON METAL DOOR
AND FRAME
SPACERS (USE AS NECESSARY)
NOTE: 2 SPACERS UNDER BOTH
MAGNET AND REED SWITCH
MUST BE USED ON STEEL DOORS
4
3
2
1
NC COM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
NC COM NO GD V+ RS1 RS2 KEYSW
4
3
2
1
NC COM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
4
3
2
1
ALARM SOUNDS WHEN DOOR IS OPENED
EMERGENCY USE ONLY
ON OFF
NCCOM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
TO KEY
SWITCH
06402 REED SWITCH
(RS2)
OPTIONAL:
TO REMOTE
HORN
STI-6403
TERMINAL BLOCK
VIEW SHOWING INSTALLATION OF
ADDTIONAL REED SWITCH 06402
3/4 in. (19mm)
MAXIMUM GAP
3/8 in. (9.5mm) ON
METAL DOOR AND FRAME
MAGNET ASSEMBLY
(SEE ABOVE FOR INSTALLATION)
DOOR
SWING
6400 SWING
MAGNET
DOOR STOP
MAGNET MUST BE
INSTALLED OPPOSITE
RAISED RIB ON OUTER COVER
19039 SCREW
6 x 1 1/4 in.
(2) PROVIDED
SPACERS - USE
AS NECESSARY
NOTE: (2) SPACERS MUST BE
USED ON STEEL DOORS
19018 ANCHOR
(2) PROVIDED
MAGNET
6400 UNIT
DOOR
SWING
JAM
DOOR STOP
DOOR
TYPICAL FLUSH MOUNT DOOR JAM
INSTALLATION
TYPICAL RECESSED MOUNT DOOR JAM
INSTALLATION
POLYCARBONATE COVER
POLYCARBONATE BASE
120 dB HORN
ALARM DURATION
ALARM TRIP DELAY
EXIT DELAY
VOLUME
VIEW OF THE CIRCUIT BOARD
19039 SCREW
6 x 1 1/4 in.
(2) PROVIDED
19018 ANCHOR
(2) PROVIDED
BOTTOM SURFACE AS SHOWN
WIRES THROUGH NOTCH ON
AND ROUTE REED SWITCH
REMOVE FRONT COVER
VIEW SHOWING MAGNET INSTALLATION
MAGNET
NC COM NO GD V+ RS1 RS2 KEYSW
TERMINAL BLOCK WIRING CONNECTIONS
FORM C
DRY
CONTACTS
REMOTE
POWER
INPUT
9-24 VDC
REED
SWITCH
TERMINALS
KEY SWITCH
TERMINALS
INTERNAL REED SWITCH
(RS1)
ALARM DURATION
ALARM TRIP DELAY
EXIT DELAY
VOLUME
VIEW OF THE CIRCUIT BOARD
MAXIMUM GAP 3/4 in. (19mm)
3/8 in. (9.5mm) ON METAL DOOR
AND FRAME
SPACERS (USE AS NECESSARY)
NOTE: 2 SPACERS UNDER BOTH
MAGNET AND REED SWITCH
MUST BE USED ON STEEL DOORS
4
3
2
1
NC COM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
NC COM NO GD V+ RS1 RS2 KEYSW
4
3
2
1
NC COM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
4
3
2
1
ALARM SOUNDSWHEN DOORIS OPENED
EMERGENCY USE ONLY
ON OFF
NCCOM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
TO KEY
SWITCH
06402 REED SWITCH
(RS2)
OPTIONAL:
TO REMOTE
HORN
STI-6403
TERMINAL BLOCK
VIEW SHOWING INSTALLATION OF
ADDTIONAL REED SWITCH 06402
3/4 in. (19mm)
MAXIMUM GAP
3/8 in. (9.5mm) ON
METAL DOOR AND FRAME
MAGNET ASSEMBLY
(SEE ABOVE FOR INSTALLATION)
DOOR
SWING
6400 SWING
MAGNET
DOOR STOP
MAGNET MUST BE
INSTALLED OPPOSITE
RAISED RIB ON OUTER COVER
19039 SCREW
6 x 1 1/4 in.
(2) PROVIDED
SPACERS - USE
AS NECESSARY
NOTE: (2) SPACERS MUST BE
USED ON STEEL DOORS
19018 ANCHOR
(2) PROVIDED
MAGNET
6400 UNIT
DOOR
SWING
JAM
DOOR STOP
DOOR
TYPICAL FLUSH MOUNT DOOR JAM
INSTALLATION
TYPICAL RECESSED MOUNT DOOR JAM
INSTALLATION
Figure 2

- 6 -
Mounting Options
TYPICAL DOUBLE DOOR INSTALLATION
STI 6402
*Note: When mounting reed switch on door and the main unit on wall, wire service loop must be used.
TYPICAL DOUBLE DOOR INSTALLATION
STI-6402
Figure 4
Figure 5
Figure 6
POLYCARBONATE COVER
POLYCARBONATE BASE
120 dB HORN
ALARM DURATION
ALARM TRIP DELAY
EXIT DELAY
VOLUME
VIEW OF THE CIRCUIT BOARD
19039 SCREW
6 x 1 1/4 in.
(2) PROVIDED
19018 ANCHOR
(2) PROVIDED
BOTTOM SURFACE AS SHOWN
WIRES THROUGH NOTCH ON
AND ROUTE REED SWITCH
REMOVE FRONT COVER
VIEW SHOWING MAGNET INSTALLATION
MAGNET
NC COM NO GD V+ RS1 RS2 KEYSW
TERMINAL BLOCK WIRING CONNECTIONS
FORM C
DRY
CONTACTS
REMOTE
POWER
INPUT
9-24 VDC
REED
SWITCH
TERMINALS
KEY SWITCH
TERMINALS
INTERNAL REED SWITCH
(RS1)
ALARM DURATION
ALARM TRIP DELAY
EXIT DELAY
VOLUME
VIEW OF THE CIRCUIT BOARD
MAXIMUM GAP 3/4 in. (19mm)
3/8 in. (9.5mm) ON METAL DOOR
AND FRAME
SPACERS (USE AS NECESSARY)
NOTE: 2 SPACERS UNDER BOTH
MAGNET AND REED SWITCH
MUST BE USED ON STEEL DOORS
4
3
2
1
NC COM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
NC COM NO GD V+ RS1 RS2 KEYSW
4
3
2
1
NC COM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
4
3
2
1
ALARM SOUNDSWHEN DOORIS OPENED
EMERGENCY USE ONLY
ON OFF
NCCOM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
TO KEY
SWITCH
06402 REED SWITCH
(RS2)
OPTIONAL:
TO REMOTE
HORN
STI-6403
TERMINAL BLOCK
VIEW SHOWING INSTALLATION OF
ADDTIONAL REED SWITCH 06402
3/4 in. (19mm)
MAXIMUM GAP
3/8 in. (9.5mm) ON
METAL DOOR AND FRAME
MAGNET ASSEMBLY
(SEE ABOVE FOR INSTALLATION)
DOOR
SWING
6400 SWING
MAGNET
DOOR STOP
MAGNET MUST BE
INSTALLED OPPOSITE
RAISED RIB ON OUTER COVER
19039 SCREW
6 x 1 1/4 in.
(2) PROVIDED
SPACERS - USE
AS NECESSARY
NOTE: (2) SPACERS MUST BE
USED ON STEEL DOORS
19018 ANCHOR
(2) PROVIDED
MAGNET
6400 UNIT
DOOR
SWING
JAM
DOOR STOP
DOOR
TYPICAL FLUSH MOUNT DOOR JAM
INSTALLATION
TYPICAL RECESSED MOUNT DOOR JAM
INSTALLATION
POLYCARBONATE COVER
POLYCARBONATE BASE
120 dB HORN
ALARM DURATION
ALARM TRIP DELAY
EXIT DELAY
VOLUME
VIEW OF THE CIRCUIT BOARD
19039 SCREW
6 x 1 1/4 in.
(2) PROVIDED
19018 ANCHOR
(2) PROVIDED
BOTTOM SURFACE AS SHOWN
WIRES THROUGH NOTCH ON
AND ROUTE REED SWITCH
REMOVE FRONT COVER
VIEW SHOWING MAGNET INSTALLATION
MAGNET
NC COM NO GD V+ RS1 RS2 KEYSW
TERMINAL BLOCK WIRING CONNECTIONS
FORM C
DRY
CONTACTS
REMOTE
POWER
INPUT
9-24 VDC
REED
SWITCH
TERMINALS
KEY SWITCH
TERMINALS
INTERNAL REED SWITCH
(RS1)
ALARM DURATION
ALARM TRIP DELAY
EXIT DELAY
VOLUME
VIEW OF THE CIRCUIT BOARD
MAXIMUM GAP 3/4 in. (19mm)
3/8 in. (9.5mm) ON METAL DOOR
AND FRAME
SPACERS (USE AS NECESSARY)
NOTE: 2 SPACERS UNDER BOTH
MAGNET AND REED SWITCH
MUST BE USED ON STEEL DOORS
4
3
2
1
NC COM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
NC COM NO GD V+ RS1 RS2 KEYSW
4
3
2
1
NC COM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
4
3
2
1
ALARM SOUNDSWHEN DOORIS OPENED
EMERGENCY USE ONLY
ON OFF
NCCOM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
TO KEY
SWITCH
06402 REED SWITCH
(RS2)
OPTIONAL:
TO REMOTE
HORN
STI-6403
TERMINAL BLOCK
VIEW SHOWING INSTALLATION OF
ADDTIONAL REED SWITCH 06402
3/4 in. (19mm)
MAXIMUM GAP
3/8 in. (9.5mm) ON
METAL DOOR AND FRAME
MAGNET ASSEMBLY
(SEE ABOVE FOR INSTALLATION)
DOOR
SWING
6400 SWING
MAGNET
DOOR STOP
MAGNET MUST BE
INSTALLED OPPOSITE
RAISED RIB ON OUTER COVER
19039 SCREW
6 x 1 1/4 in.
(2) PROVIDED
SPACERS - USE
AS NECESSARY
NOTE: (2) SPACERS MUST BE
USED ON STEEL DOORS
19018 ANCHOR
(2) PROVIDED
MAGNET
6400 UNIT
DOOR
SWING
JAM
DOOR STOP
DOOR
TYPICAL FLUSH MOUNT DOOR JAM
INSTALLATION
TYPICAL RECESSED MOUNT DOOR JAM
INSTALLATION

- 7 -
STI-6402 Double Door Install Notes
1. Determine length needed for reed switch
wires. STI provides 1 reed switch with 6 ft.
wires. Cut to desired length.
2. Connect first reed switch in RS1 and
second in RS2 (Fig. 7). (Refer to Fig. 1 for
additional details on page 4.)
3. If not using extra reed switch, add jumper
across two terminals of RS2 on terminal
block.
*Note: Alarm will sound when either door is
opened.
STI-6403 Remote Horn Install Notes
NOTE: WIRING NOT PROVIDED
NOTE: 14-24 AWG MAY
BE USED.
B
EXISTING
EXISTING
TO STI 6400 CIRCUIT
BOARD TERMINAL STRIP.
VIEW IN DIRECTION OF ARROW
REMOTE HORN WIRE CONNECTIONS
STI-6403 REMOTE HORN UNIT INSTALLATION
B
ROUTE WIRES
THROUGH NOTCH KEY SWITCH
1. Remove cover.
2. Connect two conductor wire (14-24 AWG)
from main unit terminal block pins COM
and NO to remote horn unit terminal block.
(wire not provided). Units can be set up to
300 ft. apart. Not polarity sensitive (refer to
Fig. 1 and Fig. 7 for details).
3. Connect internal battery.
4. Mount similar to main unit with #8 x 1 in.
screws and anchors if necessary.
5. Replace cover and screws.
6. Turn key switch to ON position.
*Note: The ON/OFF key position is opposite
from 6400 main unit. Remote horn sounds
when main unit alarm is activated.
STI-6404 Double Door with Remote Horn Install Notes
The STI-6404 is a combination unit for double doors with a remote horn. Reference the installation
instructions for the main unit, the STI-6402 and the STI-6403 for complete installation.
STI-6405 Exit Stopper with Momentary Reset
The STI-6405 uses a momentary switch. After initial
installation, unit is always on and you do not have to
remember to turn it on when you leave a protected area.
This model also eliminates having to remember to re-arm it
because it is never off.
When the alarm is triggered, to silence the alarm, insert the
key and turn completely to the “RESET” position and hold
for 2 seconds, then release. The switch will spring back to
its original position and push the key out. To turn the unit
off, supply power must be removed.
RESET
Figure 7
Figure 8
POLYCARBONATE COVER
POLYCARBONATE BASE
120 dB HORN
ALARM DURATION
ALARM TRIP DELAY
EXIT DELAY
VOLUME
VIEW OF THE CIRCUIT BOARD
19039 SCREW
6 x 1 1/4 in.
(2) PROVIDED
19018 ANCHOR
(2) PROVIDED
BOTTOM SURFACE AS SHOWN
WIRES THROUGH NOTCH ON
AND ROUTE REED SWITCH
REMOVE FRONT COVER
VIEW SHOWING MAGNET INSTALLATION
MAGNET
NC COM NO GD V+ RS1 RS2 KEYSW
TERMINAL BLOCK WIRING CONNECTIONS
FORM C
DRY
CONTACTS
REMOTE
POWER
INPUT
9-24 VDC
REED
SWITCH
TERMINALS
KEY SWITCH
TERMINALS
INTERNAL REED SWITCH
(RS1)
ALARM DURATION
ALARM TRIP DELAY
EXIT DELAY
VOLUME
VIEW OF THE CIRCUIT BOARD
MAXIMUM GAP 3/4 in. (19mm)
3/8 in. (9.5mm) ON METAL DOOR
AND FRAME
SPACERS (USE AS NECESSARY)
NOTE: 2 SPACERS UNDER BOTH
MAGNET AND REED SWITCH
MUST BE USED ON STEEL DOORS
4
3
2
1
NC COM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
NC COM NO GD V+ RS1 RS2 KEYSW
4
3
2
1
NC COM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
4
3
2
1
ALARM SOUNDSWHEN DOORIS OPENED
EMERGENCY USE ONLY
ON OFF
NCCOM NO GD V+ RS1 RS2 KEYSW
SLOTS
FLANGES
TERMINAL STRIP
9 VOLT BATTERY
19011 TAMPERPROOF SCREW
(1) PROVIDED
19016 TAMPER WRENCH
(1) PROVIDED
BASE
19014 MOUNTING SCREW
(4) PROVIDED
REED SWITCH
MOUNTING LOCATIONS
(LABELED 1-4)
COVER
TO KEY
SWITCH
06402 REED SWITCH
(RS2)
OPTIONAL:
TO REMOTE
HORN
STI-6403
TERMINAL BLOCK
VIEW SHOWING INSTALLATION OF
ADDTIONAL REED SWITCH 06402
3/4 in. (19mm)
MAXIMUM GAP
3/8 in. (9.5mm) ON
METAL DOOR AND FRAME
MAGNET ASSEMBLY
(SEE ABOVE FOR INSTALLATION)
DOOR
SWING
6400 SWING
MAGNET
DOOR STOP
MAGNET MUST BE
INSTALLED OPPOSITE
RAISED RIB ON OUTER COVER
19039 SCREW
6 x 1 1/4 in.
(2) PROVIDED
SPACERS - USE
AS NECESSARY
NOTE: (2) SPACERS MUST BE
USED ON STEEL DOORS
19018 ANCHOR
(2) PROVIDED
MAGNET
6400 UNIT
DOOR
SWING
JAM
DOOR STOP
DOOR
TYPICAL FLUSH MOUNT DOOR JAM
INSTALLATION
TYPICAL RECESSED MOUNT DOOR JAM
INSTALLATION

- 8 - Inst. 6400 NOV2013
Printed in USA Subject to change without notice.
2306 Airport Rd • Waterford, MI 48327
Phone: 248-673-9898 • Fax: 248-673-1246
[email protected] • www.sti-usa.com
Safety Technology International (Europe) Ltd.
Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch
Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999
Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (UK only)
E-mail: [email protected] • Web: www.sti-europe.com
We Protect the Things that Protect You.
This manual suits for next models
5
Table of contents
Other STI Security Sensor manuals
Popular Security Sensor manuals by other brands

PCB Piezotronics
PCB Piezotronics TORKDISC 5302D-02A/012AC080AT Installation and operating manual

PCB
PCB Load & Torque 4115K-13A Installation and operating manual

ADEMCO
ADEMCO RX360SN quick start guide

DEFA
DEFA Home Motion Detector user manual

LEGRAND
LEGRAND 0 488 17 Technical data sheet

Evolveo
Evolveo Salvarix ACS SMKY4 manual

Satel
Satel COBALT Pro user manual

General Monitors
General Monitors IR400 manual

IFM Electronic
IFM Electronic OPU2 Series operating instructions

Rosslare
Rosslare PYR-2021 installation instructions

Woodway
Woodway PPS Series operating instructions

STEINEL PROFESSIONAL
STEINEL PROFESSIONAL IR Quattro KNX operating instructions