1.1 Description of the unit
The STIEBEL ELTRON IP pressureless
(open) instantaneous water heater is a
device for heating water for a shower.
The unit switches the power on once the
ow volume reach 1.5-2 l/min.
The “Power” light (e) indicates that the
unit is switched on. If the temperature
adjustment rotary (c) switch is turned to
the lelf, it is possible to take a cold shower
(the heater will not be switched on).
Model IP has a built-in booster pump.
Switch (b) is a push-on/push-o switch for
the pump function. When the inlet water
pressure is too low for a good shower ow,
this booster pump can be switched“ON” to
provide stronger shower spray.
The IP is tted with an overheating protection
device.
In the event of overheating
the heating
power will be cut o.
1.2 The essentials - in brief (g 1)
a. External valve
b. Push ON/OFF Pump switch
c. Rotary temperature control
d. Pump light
e. Power light
f. Shower accessories
1.3 Important information
The unit must not be put under
pressure. The outlet of the unit
is also used as a vent. A periodical scale
removal is essential for the function of the
shower head.
1. Installation Instruction
for the user and the qualitied installer
The unit is equipped with an
ELCB. It is recommended to test
the ELCB one time per month.
Warning!
If, during a shower, the water
valve is closed, (such as applying soap to
the body), then valve opened again, high
water temperature may occur. To avoid risk
of scalding, stay away from the shower head
discharge zone momentarily.
Thermostat cut-o is a service
case only for qualied techni
cian
1.4 Care and Maintenance
All that is needed for cleaning of the housing
is a damp cloth. Do not use any abrasive
cleaning agents or agent containing solvents.
Maintenance work may only be
carried out by a qualied technician.
1.5 Hot water capacity
The hot water capacity depends on the
power of the unit, the cold water temperature,
and the ow volume.
1.6 Regulations and Provisions
- Regulations of the local power supply
company should be observed.
- Regulations of the water supply company
should be observed
- Read & study the technical data.
- Install the unit vertically on the wall.
- Electrical connection to be secured.
The device must be capable of
being
isolated from the mains, for
example by fuses, with an isolating distance
of at least 3.5 mm, in all poles.
The unit must be earthed (see
circui
t diagram).
To protect against water penetration, the
cable seal (11) must be used.
1.7 Important note
All the information in this operating
and installation instructions must
be carefully followed. These instructions
provide important details regarding the
safety, operation, installation and maintenance
of the unit.
1.8 Installation location
The shower unit is to be installed
in a closed, frost-free room
(disconnected units are to be stored in a
frost-free location, since there will always be
some water left in the unit). The IP is to be
installed vertically on a wall (hot water
connection downwards).
1.9 Technical data
(the data on the unit rating plate apply) IP
Type 35 EC 45 EC 60 EC
Nominal capacity 0.25 L
Design Open outlet
Rated pressure 0MPa / 0 bar
Water connection G 1/2”
Recommend circuit breaker (A) 20 30 30
Electrical connection 1/N/PE~220...240V
Rated power (kW) - Rated current (A) kW - A kW - A kW - A
220 V 3.5 - 15.9 4.5 - 20.5 6.0 - 27.3
230 V 3.8 - 16.5 4.9 - 21.3 6.6 - 28.7
240 V 4.2 - 17.5 5.4 - 22.5 7.1 - 29.6
Recommend cable size (Sqmm.) 4.0 6.0 6.0