manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Streetwize
  6. •
  7. Remote Starter
  8. •
  9. Streetwize SWPP5 User manual

Streetwize SWPP5 User manual

Streetwize Accessories E-mail: [email protected] www.streetwizeaccessories.com
JUMPSTARTING
1. Turn ignition OFF. Turn off all accessories such as lights, radio, air conditioner, etc...
2. Make sure all switches on the Jumpstart System are turned OFF.
3. Securely connect the Red (+) clamp to your vehicle battery’s positive (+) battery terminal.
4. Check that vehicle is negatively grounded (most vehicles). Securely connect the negative (-) black clamp to the
vehicle chassis, engine block or a non- moving metal part of the vehicle which is verified to be grounded. Do not
clamp directly to negative battery terminal, carburetor, fuel lines, or sheet metal body parts. Check cable
connection polarity indicator.
5. Start vehicle. If vehicle does not start, wait 3 minutes before trying again (failure to wait may damage Jumpstart).
6. After vehicle starts, disconnect the black negative clamp first than the red positive clamp.
SPECIFICATIONS
1. Built-in Battery: 12-Volt Rechargeable Sealed Lead Acid Battery
2. Work Light: 5 x LEDs
3. Compressor: 260 PSI Reading Gauge
4. Inverter: 230 volt AC 200 Watt (400 Watt Peak)
5. 12V Power Port: 12-volt 11A max.
6. Charging Time: 38 hours by AC charger at home
16 hours by DC charger in vehicle
The WEEE symbol on this product means that this product should be ethically dismantled or recycled to
minimise environmental impact. Please check with your local authority for more information.
IMPORTANT: ADDITIONAL SAFETY INFORMATION
This Power Station/Emergency Jumpstart is NOT intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are supervised or
have been given instruction concerning use of the Power Station/Emergency Jumpstart by a person responsible
for their safety.
EC DECLARATION OF CONFORMITY
In accordance with EN ISO 170504:2004
We; The Ace Supply Co Ltd., T/A Streetwize Accessories
Of; Unit 9, Warth Rd Ind Estate, Warth Road, Bury,Lancashire BL9 9NB
And in accordance with the following Directive(s):
2004/108/EC The Electromagnetic Compatibility Directive
2011/55/EC The Low Voltage Directive
2006/42/EC The Machinery Directive
hereby declare that: SWPP5 - 5 in 1 Power Station with Air Compressor
is in conformity with the applicable requirements of the following directives:
EN55014-1:2006, EN55014-2:1997+A1:2001, EN55015:2006+A1:2007, EN61541:1995+A1:2000,
EN61000-3-2:2006, EN61000-3-3:2008, EN61558-1:1997+A1:1998+A11:2003, EN61558-2-4:1997,
EN61558-2:17:1997, EN60950-1:2006, EN60335-1:2002+A1:2004+A2:2006+A11:2004+A12:2006
2011/65/EU Verification Testing Of Restriction Of hazardous Substances (ROHS)
Signed by: Name: Antony Collier - QC Manager
Signed at Bury on 18/12/12
Professional Solutions
5-in-1 Power Station & Emergency
Jumpstarter with Air Compressor
SWPP5
RoHS
COMPLIANT
Lancashire
BL9 9NB
• 900 Amp Battery Jumper • 260 Psi Air Compressor • 200 Watt Power Inverter
• 12 Volt Power Station • Work Light
WELCOME: This product has been carefully engineered and manufactured to give you dependable operation. Please
read this manual thoroughly before operating your new product as it contains the information you need to become
familiar with its features and obtain the performance that will bring you continued enjoyment for many years. Please
keep this manual on file for future reference.
IMPORTANT: PRIOR TO USE, READ AND UNDERSTAND ALL WARNINGS, CAUTIONS AND INSTRUCTIONS INCLUDED IN
THIS INSTRUCTION MANUAL, AND THOSE PUBLISHED BY YOUR VEHICLE BATTERY MANUFACTURER AND
MANUFACTURER OF ANY DEVICE INTENDED TO BE USED WITH THIS UNIT.
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
LOCATION OF CONTROLS
1. Rubberized Handle
2. Air Compressor On/Off Switch
3. Air Compressor Gauge
4. Heavy Duty Booster Clamps
5. 12V Socket
6. LED Work Light On/Off Switch
7. Voltmeter
8. Battery Status Button
9. 5 LED Work Light
10. Inverter On/Off Switch
11. AC Outlet
12. Air Hose Compartment
13. Jumpstarter On/Off Switch
14. Air Cooling Fan
CAUTIONS
• To protect against electrical hazards, do not immerse
charger, adapters, or unit in water or other liquid.
• Close supervision is necessary when used near children.
• Do not use unit for applications other than its intended use.
• Recharge battery after every use.
• Avoid touching eyes when working with batteries.
• If battery acid comes in contact with skin or eyes, flash with water immediately and get medical attention.
• Remove metal jewelry or objects from your body when using the unit.
• Never allow red and black clamps to touch each other or to touch the same metal object.
• Always connect the red (+) clamp to the positive battery terminal first.
• Do not connect black (-) clamp to the negative battery terminal, connect it to a non-moving metal part on your vehicle.
• Jumpstart vehicles in a well ventilated area only.
• Monitor the pressure gauge during use. Be careful not to over-inflate objects.
WORK LIGHT:
• Simply turn the work light switch
(on front panel) to ON position
• The 5 x LEDs will illuminate.
• Turn OFF while not in use.
IMPORTANT WARNING: This product is only supplied with a minimal amount
of charge at manufacture, therefore for this product to operate correctly it has
to be fully charged for a period of 38 hours IMMEDIATELY after purchase, this
is essential BEFORE ANY USE! & cannot be used DURING the charge period.
Failure to adhere to these conditions may invalidate the products warranty.
SWPP5 Manual AW:Layout 1 3/4/13 09:52 Page 1
CAUTION:
Some rechargeable devices are equipped with a separate charger, which can be connected into this inverter AC
receptacle. However certain rechargeable devices are manufactured with built-in chargers (see device owner’s
manual). This category of devices may cause internal damage to inverters and should not be used with this inverter.
The temperature of the device must be monitored for the first 15 minutes of operation. Abnormally elevated
temperature of the device is an indication that they should not be used with this inverter.
STORAGE:
This unit may be stored in any position. Make sure the clamps are secure inside the booster cable storage covers.
Store at room temperature. If not used for a prolonged period of time, recharge every 2 months in the winter and
every month in the summer.
BATTERY STATUS:
• Press and hold the Battery Level Button.
• The Voltage Meter will show the battery level.
• 13~15 Volt: Ready to use.
• 12 Volt: Charge necessary
• Below 12 Volt: Charge immediately
CHARGING YOUR JUMPSTART SYSTEM
AC Charging At Home (230v)
1. Completely charge your Jumpstart before using for the first time.
2. Before recharging from an AC outlet, be sure the source is right. (i.e.110 volts or 230 volts)
3. Use only the chargers provided with unit.
4. Keep the power on/off safety switch in OFF position while charging.
5. Plug the AC charging cord into any standard wall outlet and the other end into the AC/DC charging input socket.
6. Full charge takes approximately 34 hours - Do not exceed recommended charging time 48 hours
DC Charging In Your Vehicle (12v)
1. Keep the power on/off safety switch in OFF position while charging.
2. Plug the DC charging cord into any 12 volt (cigarette lighter) outlet and the other end into the AC/DC charging
input socket.
3. Full charge takes approximately 12 hours
Do not exceed recommended charging time – initial charge 24 hours.
USING AIR COMPRESSOR
1. Open compartment door at the back of the power center and pull out air hose. Make sure nozzle lever is in
he UP position.
2. Attach the valve adapter to the valve stem of tires and push the valve adapter lever down to lock into place.
3. Turn compressor switch on front panel to ON position.
4. Monitor the pressure gauge while inflating.
5. When appropriate pressure has been reached, turn compressor OFF and disconnect hose.
Note: It is recommended to use a separate air gauge to check the actual inflation pressure. When desired pressure
is reached, turn off compressor, turn the locking thumb lever to up position and remove stem connector from valve
stem. Also remove valve stem adapter if applicable.
USING 12 VOLT DC POWER PORT
1. Remove the protective cover.
2. Plug in your 12 volt accessory.
3. Turn power port switch to ON.
4. At full charge the power center will power B/W TV, spotlight for 4 hours, mini-cooler for 3 hours, portable vacuum,
coffee maker for 1 hour.
Time may vary depending upon current draw of attached accessory.
USING AC INVERTER
1. Prior to connecting inverter, maker sure the inverter switch in OFF position.
2. Prior to plugging in device, make sure the device is OFF and ensure the current drawn of this device
is max. 200 watt.
3. Connect the device electrical plug into the inverter receptacle.
4. Press the inverter to ON position. If the inverter is working properly, a green LED indicator will illuminate. Now turn
ON the device. If the green indicator remains on, then the system is operating properly. If the inverter green LED light
turns OFF, turn off the device then turn off the inverter immediately. See the trouble shooting guide. The inverter may
have been over loaded or the input voltage may be too low.
Trouble Cause Remedy
Lack of power output 1. Power center voltage below 12 volt. 1. Recharge the Power Center
immediately.
2. Excessive current drawn by 2. Reduce load to maximum 200 watts.
appliance being operated.
3. Inverter not completely warmed up. 3. Turn OFF the device and inverter.
Disconnect device. Turn the inverter ON
and leave running for a minimum of 2
minutes. Turn OFF inverter, quickly plug in
device to inverter making sure device
is OFF prior to connection. Turn ON the
inverter and the device.
4. Inverter fuse blown. 4. Replace a new 25 AMP rated fuse.
To replace fuse: REMOVE fuse with a
needle nose pliers and replace with a
new 25 AMP fuse.
LED light OFF 1. Inadequate power or excessive 1. Check power center and recharge is
voltage drop. voltage drops below 12 volt.
2. Inverter is overloaded. 2. Replace load to maximum of 200
watts.
Television/Power Tool 1. High surge wattage requirement 1. Toggle the On/Off switch in quick
will not start to start-up. succession a total of 5 times in order to
generate the necessary power to start the
device. If the device does not turn on or
start up in 5 cycles of ON/OFF trials. This
inverter will not work with the device.
Television Interference 1. Picture breaking up (snow). 1. Place the inverter (power center) as far
as possible from TV, the antenna and the
coaxial cable.
2. TV station may be out or range.
Static/Noise interference 1. Sound system has weak alternating 1. Do not use inverter with low quality
in audio system current shielding. audio AC filtering system.
2. Replace audio system with high quality
noise filtering.
SWPP5 Manual AW:Layout 1 3/4/13 09:52 Page 3

Other Streetwize Remote Starter manuals

Streetwize SWPB1 User manual

Streetwize

Streetwize SWPB1 User manual

Streetwize SWPP4 User manual

Streetwize

Streetwize SWPP4 User manual

Streetwize SWPP2 User manual

Streetwize

Streetwize SWPP2 User manual

Streetwize SWPP1 User manual

Streetwize

Streetwize SWPP1 User manual

Streetwize SWPP17 User manual

Streetwize

Streetwize SWPP17 User manual

Streetwize SWPB1 User manual

Streetwize

Streetwize SWPB1 User manual

Streetwize SWPP14 User manual

Streetwize

Streetwize SWPP14 User manual

Streetwize SWPP20 Specification sheet

Streetwize

Streetwize SWPP20 Specification sheet

Streetwize SWPP3 User manual

Streetwize

Streetwize SWPP3 User manual

Popular Remote Starter manuals by other brands

ATD Tools ATD-5921 owner's manual

ATD Tools

ATD Tools ATD-5921 owner's manual

Cojali JT3013 instruction manual

Cojali

Cojali JT3013 instruction manual

Wagan iOnBoost V8 user manual

Wagan

Wagan iOnBoost V8 user manual

Ultra Start 90 Series owner's guide

Ultra Start

Ultra Start 90 Series owner's guide

idatastart BM1 owner's guide

idatastart

idatastart BM1 owner's guide

Schumacher SL1435 owner's manual

Schumacher

Schumacher SL1435 owner's manual

Audiovox Electronics PRO-9275T Pursuit Series installation manual

Audiovox Electronics

Audiovox Electronics PRO-9275T Pursuit Series installation manual

G.I.KRAFT GI35111 owner's manual

G.I.KRAFT

G.I.KRAFT GI35111 owner's manual

Astroflex MV-801 user manual

Astroflex

Astroflex MV-801 user manual

MEGATRONIX MEGALARM MEGA 2400 Operation manual

MEGATRONIX

MEGATRONIX MEGALARM MEGA 2400 Operation manual

IC Dynamics RS125 installation instructions

IC Dynamics

IC Dynamics RS125 installation instructions

Black Widow Security BW FM 250 owner's manual

Black Widow Security

Black Widow Security BW FM 250 owner's manual

REXENER 18000 user manual

REXENER

REXENER 18000 user manual

CrimeStopper CS-845RKE Series II Installation & operating instructions

CrimeStopper

CrimeStopper CS-845RKE Series II Installation & operating instructions

Projecta INTELLI-START PJ-IS2000-2 owner's manual

Projecta

Projecta INTELLI-START PJ-IS2000-2 owner's manual

NOCO Genius BOOST MAX GB250+ user manual

NOCO Genius

NOCO Genius BOOST MAX GB250+ user manual

CrimeStopper REVO-1 Series instruction manual

CrimeStopper

CrimeStopper REVO-1 Series instruction manual

Directed Electronics Ready Remote 23926 installation manual

Directed Electronics

Directed Electronics Ready Remote 23926 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.