Subaru RGV12100 User manual

3ZZ9020236
ISSUE EMD-GU7306
PRINTEDINJAPAN
January2012
SUBARU Generator

AIR INDEX
Descriptive Term Applicable to Emissions Durability Period
Moderate - 50 hours (engine from 0 to 80 cc)
125 hours (engine greater than 80 cc)
Intermediate-125 hours (engine from 0 to 80 cc)
250 hours (engine greater than 80 cc)
Extended - 300 hours (engine from 0 to 80 cc)
500 hours (engine greater than 80 cc)
1000 hours (225 cc and greater)
WARNING:
The engine exhaust from this product contains
chemicals known to the State of California to
cause cancer, birth defects or other reproductive
harm.
DANGER
To show compliance with California emission regulations, a hangtag has been provided
displaying the Air Index level and durability period of this engine.
The Air Index level defines how clean an engine’s exhaust is over a period of time. A bar
graph scaled from “0” (most clean) to “10” (least clean) is used to show an engine’s Air Index
level. A lower Air Index level represents cleaner exhaust from an engine.
The period of time (in hours) that the Air Index level is measured is known as the durability
period. Depending on the size of the engine, a selection of time periods can be used to
measure the Air Index level (see below).
Notice : This hangtag must remain on this engine or piece of equipment, and only be
removed by the ultimate purchaser before operation.
Notice : FEDERAL EMISSION COMPONENT DEFECT WARRANTY and CALIFORNIA EMISSION CONTROL
WARRANTY are applicable to only those engines/ generators complied with EPA (Environmental
Protection Agency) and CARB (California Air Resources Board) emission regulations in the U.S.A.
Notice : To the engines/generators exported to and used in the countries other than the U.S.A., warranty service
shall be performed by the distributor in each country in
accordance with the standard SUBARU
engine/generator warranty policy as applicable.
(California Proposition 65)(CPSC 16 CFR Part 1407)
(California only)
Only use OUTSIDE and
far away from windows,
doors, and vents.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is
a poison you cannot see or smell.

ENGLISHFRANÇAISEESPAÑOL
FOREWORD
Thank you very much for purchasing a SUBARU GENERATOR.
This manual covers operation and maintenance of the SUBARU GENERATOR.
This SUBARU GENERATOR can be used for general electrical equipments, appliances, lamps, tools
as an AC power source. With regards to DC application, the terminals are used only for charging 12
volt battery.
Never use this generator for any other purposes.
Please take a moment to familiarize yourself with the proper operation and maintenance procedures in
order to maximize the safe and efficient use of this product.
Keep this owner’s manual at hand, so that you can refer to it at any time.
Due to constant efforts to improve our products, certain procedures and specifications are subject to
change without notice.
When ordering spare parts, always give us the MODEL, PRODUCTION NUMBER (PROD No.) and
SERIAL NUMBER (SER No.) of your Product.
Please fill in the following blanks after checking the production number on your product.
(Location of label is different depending on the product model.)
CONTENTS
1. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2. SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3. COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4. PRE-OPERATION CHECKS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5. OPERATING PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.WATTAGE INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
7. SPARK ARRESTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
8. MAINTENANCE SCHEDULE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
9. "HOW-TO" MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
10. PREPARATION FOR STORAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
11.TROUBLESHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
12. WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
13.OPTIONAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
PROD No. / SER No. (Label)
PROD No. SER No.
RGV13100usGU7306.indd01RGV13100usGU7306.indd01 2012/01/2315:22:462012/01/2315:22:46

ENGLISHFRANÇAISEESPAÑOL
USA and CANADA only
Read INSTRUCTIONS
FOR USE before use.
The engine emits toxic gas
can kill you in minutes.
Do not run in an enclosed area.
Hot surface can burn you.
Stay away if engine has
been running.
Gasoline is extremely flammable and its vapors can explode.
• Stop the engine before refueling.
• Check for leakage from hoses and fittings.
• Shut off fuel valve when the engine is not in use.
RGV13100usGU7306.indd02RGV13100usGU7306.indd02 2012/01/2315:22:472012/01/2315:22:47

ENGLISHFRANÇAISEESPAÑOL
-
1
-
1. SAFETY PRECAUTIONS
Please make sure you review each precaution carefully.
Pay special attention to statement preceded by the following words.
“DANGER” indicates a possibility of death or serious injury if instructions
are not followed.
“WARNING” indicates a strong possibility of severe personal injury or loss of
life if instructions are not followed.
“CAUTION” indicates a possibility of personal injury or equipment damage
if instructions are not followed.
Do not operate the generator near gasoline or gaseous fuel because of the potential
danger of explosion or fire.
Do not fill the fuel tank with fuel while the engine is running. Do not smoke or use open
flame near the fuel tank. Be careful not to spill fuel during refueling.
If fuel is spilt, wipe it off and let dry before starting the engine.
Do not place in flammables near the generator.
Be careful not to place fuel, matches, gunpowder, oily cloths, straw, trash,
or any other in flammables near the generator.
Do not enclose the generator nor cover it with a box.
The generator has a built-in forced air cooling system, and may become overheated if it is enclosed.
If generator has been covered to protect it from the weather during non use, be sure to remove it and keep it well away
from the area during generator use.
1m
1m
Operate the generator on a level surface.
It is not necessary to prepare a special foundation for the generator.
However, the generator will vibrate on an irregular surface, so choose a level place without surface irregularities.
If the generator is tilted or moved during operation, fuel may spill and / or the generator may tip over, causing a
hazardous situation.
Proper lubrication cannot be expected if the generator is operated on a steep incline or slope. In such a case, piston
seizure may occur even if the oil is above the upper level.
Do not operate the generator inside a room, cave, tunnel, or other insufficiently
ventilated area.
Always operate it in a well-ventilated area, otherwise the engine may become
overheated, and the poisonous carbon monoxide gas, an odorless, colorless,
poison gas, contained in the exhaust gas will endanger human lives.
Operate generator only outdoors and far from open windows, doors, ventilation
intakes and other openings.
Keep the generator at least 1 meter (3 feet) away , including overhead, from any
structure or building use.
WARNING
WARNING
WARNING
DANGER
WARNING
CAUTION
WARNING
WARNING
Do not operate in rain, in wet or damp conditions, or with wet hands.
The operator may suffer severe electric shock if the generator is wet due to rain or snow.
WARNING
Pay attention to the wiring or extension cords from the generator to the connected device.
If the wire is under the generator or in contact with a vibrating part, it may break and possibly cause a
fire, generator burnout, or electric shock hazard.
Replace damaged or worn cords immediately.
WARNING
RGV13100usGU7306.indd1RGV13100usGU7306.indd1 2012/01/2315:22:472012/01/2315:22:47

ENGLISHFRANÇAISEESPAÑOL
-
2
-
Do not contact the generator to a commercial power line. Connection to a commercial power line may
short circuit the generator and ruin it or cause electric shock hazard.
Use the transfer switch for connecting to domestic circuit.
Engine becomes extremely hot during and for some time after operation.
Keep combustible materials well away from generator area.
Be very careful not to touch any parts of the hot engine especially the muffler area or serious
burns may result.
No smoking while handling the battery. The battery emits flammable hydrogen gas,
which can explode if exposed to electric arcing or open flame.
Keep the area well-ventilated and keep open flames/sparks away when handling the battery.
Keep children and all bystanders at a safe distance from work areas.
If wet, wipe and dry it well before starting. Do not pour water directly over the generator, nor wash it with water.
Be extremely careful that all necessary electrical grounding procedures are followed during each and every use.
Failure to do so can be fatal.
It is absolutely essential that you know the safe and proper use of the power tool or appliance that you intend to use.
All operators must read, understand and follow the tool/appliance owners manual. Tool and appliance applications and
limitations must be understood. Follow all directions given on labels and warnings. Keep all instruction manuals and
literature in a safe place for future reference.
Use only "LISTED" extension cords.
When a tool or appliance is used outdoors, use only extension cords marked "For Outdoor Use". Extension cords,
when not in use should be stored in a dry and well ventilated area.
Always switch off generator's AC circuit breaker and disconnect tools or appliances when not in use, before servicing,
adjusting, or installing accessories and attachments.
Make sure the engine is stopped before starting any maintenance, servicing or repair.
Make sure maintenance and repair of the generator set are performed by properly trained personnel only.
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
CAUTION
: PRECAUTIONS ON THE HANDLING OF THE WARNING LABEL
Warning labels are affixed to our engines with regard to particularly serious dangers.
When using the engines, please use them safely after carefully reading the instruction manual and understanding the
dangers.
CAUTION
ᵵᵟᵰᵬᵧᵬᵥ
ᵰᶃᵿᶂᴾᵧᵬᵱᵲᵰᵳᵡᵲᵧᵭᵬᵱ
ᵤᵭᵰᴾᵳᵱᵣᴾᶀᶃᶄᶍᶐᶃᴾᶓᶑᶃᵌ
ᵥᵿᶑᶍᶊᶇᶌᶃᴾᶇᶑᴾᶃᶖᶒᶐᶃᶋᶃᶊᶗ
ᶄᶊᵿᶋᶋᵿᶀᶊᶃᴾᵿᶌᶂᴾᶇᶒᶑᴾᶔᵿᶎᶍᶐᶑ
ᶁᵿᶌᴾᶃᶖᶎᶊᶍᶂᶃᵌ
Ὁᵱᶒᶍᶎᴾᶒᶆᶃᴾᶃᶌᶅᶇᶌᶃᴾᶀᶃᶄᶍᶐᶃ
ᴾᶐᶃᶄᶓᶃᶊᶇᶌᶅᵌ
Ὁ
ᵡᶆᶃᶁᶉᴾᶄᶍᶐᴾᶊᶃᵿᶉᵿᶅᶃẅᶄᶐᶍᶋ
ᴾᶆᶍᶑᶃᶑᴾᵿᶌᶂᴾᶄᶇᶒᶒᶇᶌᶅᶑᵌ
Ὁᵱᶆᶓᶒᴾᶍᶄᶄᴾ
ᶄᶓᶃᶊᴾᶔᵿᶊᶔᶃᴾᶕᶆᶃᶌ
ᴾᶒᶆᶃᴾᶃᶌᶅᶇᶌᶃᴾᶇᶑᴾᶌᶍᶒᴾᶇᶌᴾᶓᶑᶃᵌ
ᵲᶆᶃᴾᶃᶌᶅᶇᶌᶃᴾᶃᶋᶇᶒᶑᴾᶒᶍᶖᶇᶁᴾᶅᵿᶑ
ᶁᵿᶌᴾᶉᶇᶊᶊᴾᶗᶍᶓᴾᶇᶌᴾᶋᶇᶌᶓᶒᶃᶑᵌᴾᴾᵢᶍ
ᶌᶍᶒᴾᶐᶓᶌᴾᶇᶌᴾᵿᶌᴾᶃᶌᶁᶊᶍᶑᶃᶂᴾᵿᶐᶃᵿᵌ
ᵦᶍᶒᴾᶑᶓᶐᶄᵿᶁᶃᴾᶁᵿᶌᴾᶀᶓᶐᶌᴾᶗᶍᶓᵌ
ᵱᶒᵿᶗᴾᵿᶕᵿᶗᴾᶇᶄᴾᶃᶌᶅᶇᶌᶃᴾᶆᵿᶑ
ᶀᶃᶃᶌᴾᶐᶓᶌᶌᶇᶌᶅᵌ
Warning Label Exclusively for the United States and Canada
For use in the United States or Canada, please affix the label suited to the region from among the enclosed warning labels.
AVERTISSEMENT
Lire les INSTRUCTIONS
POUR L'USAGE avant d’
utiliser le moteur.
L'essence est extrêmement
inflammable et ses vapeurs
peuvent exploser.
• Arrêter le moteur avant de
faire le plein en combustible.
• Vérifier toute présence de
fuite à partir des tuyaux et
garnitures.
• Bloquer la soupape de
carburant quand le moteur
n’est pas utilisé.
Le moteur émet un gaz toxique
qui peut tuer l’opérateur en
quelques minutes.
Ne pas utiliser le moteur dans
un emplacement fermé.
La surface chaude peut vous
brûler.
S’éloigner du moteur s’il est en
marche.
ADVERTENCIA
Leer las INSTRUCCIONES
PARA EL USO antes de utilizar
el motor.
La gasolina es extremadamente
inflamable y sus vapores
pueden estallar.
• Detener el motor antes de
hacer el lleno en combustible
• Comprobar si hay presencia
de fuga a partir los tubos y
guarniciones
• Bloquear la válvula de
combustible cuando no se
utiliza el motor.
El motor emite un gas tóxico
que puede matar el operador
en algunos minutos.
No utilizar el motor en un sitio
cerrado.
La superficie caliente puede
quemarles.
Alejarse del motor si es en
marcha.
RGV13100usGU7306.indd2RGV13100usGU7306.indd2 2012/01/2315:22:472012/01/2315:22:47

ENGLISHFRANÇAISEESPAÑOL
-
3
-
LOCK
UNLOCK
STOPPER
Check that following
accessories come with your
SUBARU Generator.
(1) Instruction for use
(2) Wheel mounting parts (See page 37.)
(3) Servicing tools
(4) Battery mounting bracket
(See page 8 and 9.)
Be sure to replenish with
engine oil.
(See page 6 for details.)
Notes on installation
1.If you provide the generator with wheels,
always be sure to place
the generator on a level surface, locking
the wheel with the stopper and/or
chocking the wheels.
2. Select a place which allows you to
maintain and inspect the generator,
which is not exposed to contamination
caused by exhaust gas.
If you are planning to install the
generator without its wheels attached, consider the work efficiency in terms of
an oil change.
3. In ground connection, be sure to use the designated ground terminal.
(A grounding cable is not included in the set of accessories.)
4. During use, be sure not to disconnect the battery.
5. While the power is on, do not unplug the unit or disconnect cables from the
terminals.
RGV13100usGU7306.indd3RGV13100usGU7306.indd3 2012/01/2315:22:472012/01/2315:22:47

ENGLISHFRANÇAISEESPAÑOL
-
4
-
2. SPECIFICATIONS
MODEL RGV12100 RGV13100T
Alternator
Type Brush, Self-exciting,
2-pole, Single-phase
Brush, Self-exciting,
2-pole, 3-phase
Rated frequency 60 Hz
Rated voltage 120V / 240V 120V / 208V
Maximum output 12000 VA 13000 VA
Rated output 9500 VA 10000 VA
Rated power factor 1.0 0.8
Voltage regulator A.V.R type C.T. type
Engine
Model EH65D EH63D
Type Twin cylinder, Air-cooled, 4-stroke, Overhead valve engine
Displacement 653
mL
(39.8
cu.in.
)
Fuel Automotive Unleaded Gasoline
Oil capacity 0.41 US-gal /1.55 liters
Starting system Electric starter
Fuel tank capacity 10.04 US-gal (38 liters)
Rated continuous
operation per a
tankful of fuel
Rated Approx. 7.1 hours Approx. 7.7 hours
Dimension
Length 32.5 in. / 826 mm
Width 24.1 in. (30.2 in.) / 611 mm (766 mm) *1
Height 30.4 in. (33.7 in.) / 771 mm (856 mm) *1
Dry Weight 141 kg (149 kg) *2 143 kg (151 kg) *2
Remote controller terminal
(Auto choke) Standard
-
Valve Clearance
(Intake & Exhaust)
0.0039 ±0.0008 in. (0.1 ±0.02 mm)
Note : Adjust the valve clearance while the engine is cold.
Emissions Durability Period 1000 hours
-
Specifications are subject to change without notice.
NOTE
*1: ( ) shows dimensions with castors.
*2: ( ) shows dry weight with castors installed.
RGV13100usGU7306.indd4RGV13100usGU7306.indd4 2012/01/2315:22:482012/01/2315:22:48

ENGLISHFRANÇAISEESPAÑOL
-
5
-
3. COMPONENTS
SPARK PLUG CAP
FUEL COCK
BATTERY
TANK CAP
SPARK PLUG
CAP
MUFFLER
CONNECTOR
FOR REMOTE
CONTROL
(RGV12100 only)
END COVER
(RGV13100T only)
FUEL TANK
CONTROL
PANEL AIR CLEANER
COOLING AIR
INLET PORT
OIL FILTER
CHOKE KNOB
(RGV13100T only)
OIL GAUGE
ELECTRIC STARTER
OIL DRAIN PLUG
OIL FILLER CAP
RGV13100usGU7306.indd5RGV13100usGU7306.indd5 2012/01/2315:22:482012/01/2315:22:48

ENGLISHFRANÇAISEESPAÑOL
-
6
-
4. PRE-OPERATION CHECKS
UPPER
LEVEL
LOWER
LEVEL
OIL GAUGE
OIL GAUGE
UPPER LEVEL
LOWER LEVEL
OIL FILLER CAP
CHECK ENGINE OIL
Before checking or refilling oil, be sure
generator is located on stable and level
surface with engine stopped.
1) Remove oil level gauge and check the
engine oil level.
2) If oil level is below the lower level line on
the oil gauge, refill with suitable oil (see
table) to upper level after removing the
engine oil filler cap.
3) Change oil if contaminated.
(See “How-To” Maintenance.)
NOTE:
■
The engine is equipped with an oil sensor unit
(hydraulic pressure detection type) that will
automatically stop the engine if oil in the crank
case is reduced below the specified level.
Should the engine be automatically stopped,
be sure to check the amounts of fuel and oil.
■
When the oil is reduced below the specified
level, add new oil to the upper limit. Since the
oil sensor will not detect the deterioration of
oil, visually check the quality or determine it by
the specified time and then change the oil if
necessary.
(Refer to page 28.)
Recommended engine oil:
Use 4-stroke automotive detergent oil
of API service class SE or higher grade
(SG, SH or SJ is recommended). SAE
10W-30 or 10W-40 is recommended
for general, all-temperature use. If
single viscosity oil is used, select the
appropriate viscosity for the average
temperature in your area.
Ambient
temperature
Single grade
Multigrade
5W
10W
20W
#20
#30
#40
10W
-
30
10W
-
40
Oil capacity (Upper level) : L(U.S. gal)
RGV12100 . . . . . . . . . . . . . . 1.55 (0.41)
RGV13100T . . . . . . . . . . . . . 1.55 (0.41)
RGV13100usGU7306.indd6RGV13100usGU7306.indd6 2012/01/2315:22:482012/01/2315:22:48

ENGLISHFRANÇAISEESPAÑOL
-
7
-
Fuel Amount
up to “LEVEL” position : L (U.S. gal)
RGV12100 . . . . . . . . . . . . 38.0 (10.04)
RGV13100T . . . . . . . . . . . 38.0 (10.04)
■Check fuel level at fuel level gauge.
■If fuel level is low, refill with automotive
unleaded gasoline only.
■
Use unleaded automotive gasoline only.
• Unleaded regular/premium or
reformulated gasoline containing no
more than 10% Ethanol (E10), or 15%
MTBE may also be used.
• Never use gasoline containing ethanol
exceeding 10%, or MTBE exceeding
15% because engine or fuel system
damage could result.
• Never use stale or contaminated
gasoline.
• Use of these non-recommended fuels
may result in reduced performance
and/or denial of warranty.
■Stop the engine and open the cap.
■Close the fuel valve before filling the
fuel tank.
■Be sure to use the fuel filter screen on
the fuel filter neck.
■Reattach the fuel cap by turning
clockwise until reaching the physical
stop (about one quarter turn). Do not
attempt to turn past the physical stop or
the fuel cap may be damaged.
NOTE :
■The full level of fuel is the upper surface
of the fuel filter.
Fuel filter screen
Tank cap
Fuel gauge
EMPTY FULL
EF
"LEVEL" Mark
Fuel level line
Do not refuel while smoking or near open flame or other such
potential fire hazards. Otherwise fire accident may occur.
CHECK ENGINE FUEL.
NOTE :
THIS ENGINE IS CERTIFIED TO OPERATE
ON AUTOMOTIVE UNLEADED GASOLINE.
WARNING
RGV13100usGU7306.indd7RGV13100usGU7306.indd7 2012/01/2315:22:492012/01/2315:22:49

ENGLISHFRANÇAISEESPAÑOL
-
8
-
Make sure you review each warning in order to prevent fire hazard.
■Do not refill tank while engine is running or hot.
■Close fuel cock before refueling with fuel.
■Be careful not to admit dust, dirt, water or other foreign objects into fuel.
■Do not fill above the top of the fuel filter (marked “LEVEL”) or the fuel may
overflow when it heats up later and expands.
■Wipe off spilt fuel thoroughly before starting engine.
■Keep open flames away.
WARNING
Recommended Battery
Lead-acid battery : A capacity of 12V-32A•h or larger.
For the generators used in low temparature (below -5℃),
12V-40A•h or larger battery is recommended.
1) Attach terminals to a lead-acid battery already charged. Mount the battery onto
the position as specified below, with its terminals facing inward.
2) Insert each long bolt through the specified hole, its tip pointing outward.
3) Put the supporting arm on the long bolts and tighten with the butterfly nuts.
(Push the lead-acid battery all the way inward.)
4) Arrange the wiring so that it won't be damaged by possible vibration caused by the
engine.
5) Only after checking that the engine's starter key is in the "OFF" position, securely
connect the red cable, to the positive (+) terminal. And then connect the other
cable to the negative (-) terminal.
Red cable : to the (+) terminal
Black cable : to the (-) terminal
BATTERY INSTALLATION
Continuous operation time in normal use (rated load)
RGV12100 Approx. 7.1 hours
RGV13100T Approx. 7.7 hours
RGV13100usGU7306.indd8RGV13100usGU7306.indd8 2012/01/2315:22:492012/01/2315:22:49

ENGLISHFRANÇAISEESPAÑOL
-
9
-
RED CABEL
RED CABEL
LESS THAN
10.2 in. (260 mm)
LESS THAN
6.7 in. (170 mm)
LESS THAN
8.1 in.
(205 mm)
①Butterfly nut ┓
②Long bolt ┣Accessory
③Supporting arm ┛parts
④Terminals and nut
④
①
③
②
Death, personal injury and/ or property damage may occur unless
instructions are followed carefully.
■Disconnect battery cables when charging battery.
■Use battery of specified capacity listed in the owner’s manual.
■Turn the starter switch to the “STOP” position when mounting or
dismounting battery. Connect positive (+) terminal first when mounting
battery, and disconnect negative (
-
) terminal first when dismounting.
RED CABLE : To positive (+) terminal
BLACK CABLE : To negative (
-
) terminal
WARNING
Should the connection be made in incorrect manner, the engine will be broken.
[CAUTION]
RGV13100usGU7306.indd9RGV13100usGU7306.indd9 2012/01/2315:22:492012/01/2315:22:49

ENGLISHFRANÇAISEESPAÑOL
-
10
-
CHECK COMPONENT PARTS
Check following items before starting engine:
■Fuel leakage from fuel hose, etc.
■Bolts and nuts for looseness.
■Components for damage or breakage.
■Generator not resting on or against any adjacent wiring.
CHECK GENERATOR SURROUNDINGS
Make sure you review each warning in order to prevent fire hazard.
■Keep area clear of inflammables or other hazardous materials.
■Keep generator at least 3 feet (1 meter) away from buildings or other
structures.
■Only operate generator in a dry, well ventilated area.
■Keep exhaust pipe clear of foreign objects.
■Keep generator away from open flame. No smoking!
■Keep generator on a stable and level surface.
■Do not block generator air vents with paper or other material.
WARNING
RGV13100usGU7306.indd10RGV13100usGU7306.indd10 2012/01/2315:22:492012/01/2315:22:49

ENGLISHFRANÇAISEESPAÑOL
-
11
-
5. OPERATING PROCEDURES
(1) Make sure that the AC circuit breaker
is off.
(2) Turn the fuel cock to the vertical (open)
position
(3) (RGV13100T)
Pull the choke knob to the fully closed
position.
NOTE :
Be sure to pull the choke even if the
engine is warm.
STARTING THE GENERATOR
■Check the oil level before each operations. (See page 6)
■Perform the specified Daily Inspection to see if it is in normal condition.
[CAUTION]
CLOSE
CLOSE
OPEN
CLOSE
ON
OFF
RGV13100usGU7306.indd11RGV13100usGU7306.indd11 2012/01/2315:22:492012/01/2315:22:49

ENGLISHFRANÇAISEESPAÑOL
-
12
-
START
RUN
START
STOP
RUN
STOP
(4) Turn the starter switch to the "START"
position.
If the engine won't start, turn the switch
back to "ON" position and then wait for
approximately 10 seconds to try it again.
NOTE :
■You might have to keep the starter
running for at least 3 to 5 seconds,
since the engine incorporates the
mechanism in it where the ignition
circuit is activated by the increase of
hydraulic pressure.
■In the following occasion, two or three trials may be required for starting the
engine :
(1) The very first starting of a new generator.
(2) After the refueling of the engine which has been stopped due to fuel shortage.
(3) Starting after the oil filter change.
(RGV13100T)
■Even if the engine has already been warmed, be sure to pull the choke knob.
OPEN
(4) (RGV13100T)
Return the starter switch to “ON”
position soon after the engine has
started and then push the choke knob.
In cold weather, be sure to push it
gradually.
(5) Warm the engine up for a minute or
two. Longer time would be needed in
cold weather.
RGV13100usGU7306.indd12RGV13100usGU7306.indd12 2012/01/2315:22:492012/01/2315:22:49

ENGLISHFRANÇAISEESPAÑOL
-
13
-
USING ELECTRIC POWER
CONTROL PANEL
■Make sure that the appliance is switched OFF before connecting it to
the generator.
■Do not move the generator while it is running.
■Be sure to ground the generator if the connected appliance is
grounded. Failure to ground unit may lead to electrical shock.
WARNING
(RGV12100)
KEY SWITCH
OIL PURESSURE
WARNING LAMP
0
240
110
120
220
IDLE CONTROL
SWITCH
VOLTMETER
PILOT LAMP HOUR METERNO-FUSE BREAKER
AC RECEPTACLEEARTH (GROUND)
TERMINAL
CONNECTOR
FOR REMOTE CONTROL
RGV13100usGU7306.indd13RGV13100usGU7306.indd13 2012/01/2315:22:492012/01/2315:22:49

ENGLISHFRANÇAISEESPAÑOL
-
14
-
(RGV13100T)
KEY SWITCH
OIL PURESSURE
WARNING LAMP
VOLTMETER
PILOT LAMP HOUR METERNO-FUSE BREAKER
AC RECEPTACLE
AC (THREE PHASE
and SINGLE PHASE)
RECEPTACLE
EARTH (GROUND)
TERMINAL
RGV13100usGU7306.indd14RGV13100usGU7306.indd14 2012/01/2315:22:502012/01/2315:22:50

ENGLISHFRANÇAISEESPAÑOL
-
15
-
(a) Ground the generator, using the
ground terminal located at the side of
the panel.
(b) Before starting the engine, check that
the AC circuit breaker of the generator
and the power switches of the
appliances are turned off.
(c) Connect the plugs of the appliances
to the receptacles before starting the
engine. If you wish to use for a long
period of time, connecting to the output
terminal is recommended.
(d) Start the engine and check that the
voltage meter is indicating correct
voltage.
(1) AC APPLICATION
■Check the amperage of the receptacles used referring to TABLE 1, and be
sure not to take a current exceeding the specified amperage.
■Be sure that the total wattage of all appliances dose not exceed the rated
output of the generator.
Grounding spike
ON
OFF
RGV13100usGU7306.indd15RGV13100usGU7306.indd15 2012/01/2315:22:502012/01/2315:22:50

ENGLISHFRANÇAISEESPAÑOL
-
16
-
NOTE :
When the AC circuit breaker turns off during operation, the generator is over loaded
or the appliance is defective. Stop the generator immediately, check the appliance
and / or generator for overloading or detect and have repaired as necessary by
SUBARU Industrial Power Products dealer or service shop.
■To take power out from the TWIST
LOCK RECEPTACLE, insert the
plug into the receptacle, and turn it
clockwise to the lock position.
■Be sure to ground the generator if
the connected electrical device Is
grounded.
TWIST
Style Ampere Receptacle AC plug Description
up to 20A NEMA
5-20R
NEMA
5-20P
GFCI (Ground Fault
Circuit Interrupter)
Receptacle,
duplex(REC1)
up to 30A NEMA
L5-30R
NEMA
L5-30P
Locking Receptacle
(REC2)
up to 30A NEMA
L14-30R
NEMA
L14-30P
Locking Receptacle
(REC3)
up to 50A Locking Receptacle
(REC4)
up to 30A NEMA
L21-30R
NEMA
L21-30P
Locking Receptacle
(REC5)
TABLE 1
WARNING
RGV13100usGU7306.indd16RGV13100usGU7306.indd16 2012/01/2315:22:502012/01/2315:22:50
This manual suits for next models
1
Table of contents
Other Subaru Portable Generator manuals

Subaru
Subaru Robin R1700i User manual

Subaru
Subaru RGX2900 User manual

Subaru
Subaru R1100 User manual

Subaru
Subaru RGX4800 User manual

Subaru
Subaru ROBIN RGD3300H User manual

Subaru
Subaru RGX2900 User manual

Subaru
Subaru RGX3000 User manual

Subaru
Subaru WORMS LEADER 10500 XL21 User manual

Subaru
Subaru Robin RG2800iS User manual

Subaru
Subaru SGX3500 User manual