SUBMERSIBLE SYSTEMS HEED 3 User manual

ALL INFORMATION IS PROPRIETARY AND MAY NOT BE COPIED WITHOUT WRITTEN PERMISSION OF SUBMERSIBLE SYSTEMS.
5/20
G:\Mktg\MILT\Heed 3 tech manual.hose
1
HEED 3
TECHNICAL / USER MANUAL
HELICOPTER EMERGENCY EGRESS DEVICE
MODEL 175-003 & 175-004
SUBMERSIBLE SYSTEMS, LLC
Phone: (714) 842-6566
www.HEED3.com
THE LEADER IN SELF-RESCUE BREATHING SYSTEMS

ALL INFORMATION IS PROPRIETARY AND MAY NOT BE COPIED WITHOUT WRITTEN PERMISSION OF SUBMERSIBLE SYSTEMS.
5/20
G:\Mktg\MILT\Heed 3 tech manual.hose
2
Table Of Contents
General Precautions & Warnings ......................................................................................................................2
How HEED Works ...............................................................................................................................................2
Refilling From Fill Station...................................................................................................................................3
Refilling From Scuba Cylinder...........................................................................................................................3
Mounting Instructions ........................................................................................................................................4
Pre-Use Check.....................................................................................................................................................4
Using HEED.........................................................................................................................................................4
General Servicing Information...........................................................................................................................5
Specifications......................................................................................................................................................6
GENERAL PRECAUTIONS & WARNINGS:
HEED is shipped empty. Fill prior to use.
No special training or SCUBA certification necessary for using HEED above ground or at shallow depths.
Never overfill the HEED system above 3000 psi, the air pressure stamped on the cylinder. ONLY use
purified, dry compressed breathing air when filling HEED.
DO NOT fill or use HEED if it has been exposed to extreme heat exceeding 250ºF, or open flame. Instead,
discharge the cylinder completely and return it to an Authorized dealer or the manufacturer for inspection and
possible hydrostatic testing.
HOW HEED WORKS:
Helicopter Emergency Egress Device (HEED) is a high quality emergency breathing system produced and tested by
people with more than four decades of manufacturing experience. We use the finest quality materials and techniques
in the construction of this product. Enjoy the peace of mind that having HEED brings.
First Stage Regulator Body - Typical to regulators used by
SCUBA Divers around the world, the first stage reduces the
high pressure within the cylinder to an intermediate pressure
utilized by the second stage.
Hose Port - Pivoting Hose Port for Flexible Braided Hose to
attach First Stage to Second Stage Regulator Body.
Pressure Indicator - Dial Gauge has an easy to read, color
coated display for at-a-glance pressure check in psi and bar.
Check Valve Refill Port - Refillable from an Air Compressor or
SCUBA cylinder.
Mouthpiece –High quality silicone mouthpiece.
Purge Button - Clears the regulator and empties the cylinder.
Second Stage Regulator Body - Typical to regulators used by
SCUBA Divers, the second stage allows the air from the first
stage to equalize to the surrounding water pressure providing
air at ambient pressure and normal breathing through the
mouthpiece.
On/Off Valve - Twist valve to turn the air supply on and off.
3000 PSI Aluminum Tank - This cylinder is manufactured just
like standard SCUBA cylinders, with the same safety features.
The cylinder should be inspected annually and hydrostatically
tested every 5 years.
VIP Sticker - Month and year of last cylinder visual inspection.

ALL INFORMATION IS PROPRIETARY AND MAY NOT BE COPIED WITHOUT WRITTEN PERMISSION OF SUBMERSIBLE SYSTEMS.
5/20
G:\Mktg\MILT\Heed 3 tech manual.hose
3
REFILLING HEED FROM A FILL STATION USING #920C ADAPTER:
(Use a high-pressure, breathing air quality air compressor designed to fill air systems.)
WARNING: If the HEED Check Valve Refill Port or Refill Adapter threads are damaged or worn these parts
will require replacement. Continued use may cause injury.
CAUTION: DO NOT stand directly over HEED regulator while filling.
CAUTION: Ensure the regulator is firmly attached to the cylinder (hand tight, no tools required).
1. Remove rubber cover from the Check Valve Refill Port.
2. Apply small amount of food grade silicone grease to Refill Port threads with your finger.
3. Screw Refill Adapter onto Refill Port until finger tight.
NOTE: DO NOT apply a wrench or otherwise overtighten.
4. Attach the yoke from the compressor to the Adapter.
NOTE: If line is pressurized over 3200 PSI, adjust the line pressure to 3200 PSI.
5. Turn the On/Off Valve on regulator counter-clockwise until it is completely open.
6. Turn the valve on your compressor ON.
7. Refill the cylinder to 3200 psi initially, after cooling down the pressure will be approximately 3000 psi.
Regulate the flow so that it takes approximately 45-60 seconds to fill the cylinder.
NOTE: Filling too fast can generate heat and will result in an incomplete fill after the cylinder cools.
NOTE: Fill cylinder slowly and DO NOT OVERFILL to protect the safety burst disc inside the regulator from
rupturing. If it ruptures, a new 3300 psi burst disc must be installed before unit can be filled.
8. When the cylinder is full, turn the On/Off Valve on regulator clockwise until it is completely closed.
9. Turn the compressor or fill station valve OFF.
10. Depress the second stage Purge Button until air flow can no longer be heard and the hose is depressurized.
11. Open bleed knob to release pressure in line. Remove Adapter from compressor yoke.
12. Remove Adapter from HEED and replace rubber cover on Refill Port.
13. Check the Pressure Indicator. If the tank is full, the Dial Gauge will read 3000 psi.
REFILLING HEED FROM A STANDARD SCUBA CYLINDER USING #910S ADAPTER:
WARNING: If the HEED Check Valve Refill Port or Refill Adapter threads are damaged or worn these parts
will require replacement. Continued use may cause injury.
CAUTION: DO NOT stand directly over HEED regulator while filling.
CAUTION: Ensure the regulator is firmly attached to the cylinder (hand tight, no tools required).
1. Remove rubber cover from the Check Valve Refill Port.
2. Apply small amount of food grade silicone grease to Refill Port threads with your finger.
3. Screw Refill Adapter onto Refill Port until finger tight.
NOTE: DO NOT apply a wrench or otherwise overtighten.
4. Turn knurled ring on Adapter firmly to closed (clockwise) position.
5. Attach Refill Adapter to SCUBA cylinder valve.
6. Turn the On/Off Valve on regulator counter-clockwise until it is completely open.
7. Open SCUBA cylinder valve very slowly just until you can hear air passing from one cylinder to the other.
NOTE: Filling too fast can generate heat and will result in an incomplete fill after the cylinder cools.
NOTE: If air is escaping from the Adapter during filling, close cylinder valve, wait for air to stop and re-
tighten knurled ring by turning to closed (clockwise position).
8. When at least 2 minutes have elapsed, and air can no longer be heard flowing from the cylinder, turn the
cylinder valve completely open to ensure maximum fill.
NOTE: SCUBA cylinder must be filled to 3000 psi at beginning of refill procedure in order to fill to
recommended full capacity.
9. Turn the On/Off Valve on regulator clockwise until it is completely closed.
10. Close SCUBA cylinder valve.

ALL INFORMATION IS PROPRIETARY AND MAY NOT BE COPIED WITHOUT WRITTEN PERMISSION OF SUBMERSIBLE SYSTEMS.
5/20
G:\Mktg\MILT\Heed 3 tech manual.hose
4
11. Depress the second stage Purge Button until air flow can no longer be heard and the hose is depressurized.
12. You must turn the knurled ring on Adapter to open (counter-clockwise) position to relieve pressure in the
Adapter.
NOTE: You will not be able to remove the Adapter from Refill Port until this is done.
13. Remove Adapter from SCUBA cylinder and HEED.
14. Replace rubber cover on Refill Port.
MOUNTING INSTRUCTIONS:
Optional HEED 3 Holster is designed to attach to a modular style vest (MOLLE).
1. Weave the 2 straps on the back of the modular holster through the webbing of vest (left side recommended)
and snap into place.
NOTE: It is important that the operator be able to grip the regulator having sufficient clearance for a pull of at
least 6 inches.
2. Place unit in Holster and attach flap securely over the regulator ensuring velcro is fully engaged.
3. Attach Mouthpiece Cover.
4. Affix the included small velcro tab located on the metal ring to another web to help secure the holster.
PRE-USE CHECK:
1. Check for obvious physical damage, broken or loose parts. Do not use if damaged.
2. Turn the system on by turning the On/Off Valve counter-clockwise until it is completely open.
3. Visually check Dial Gauge for needle to be within green zone. Refill if necessary.
4. Push Purge Button down and release. Purge Button should move up and down freely. To maintain full
pressure do not purge unnecessarily.
USING HEED:
1. Grab HEED regulator head and pull until Hose is completely out of the Holster. This action will release the
Mouthpiece Cover.
2. Place the HEED regulator into user’s mouth.
3. If the system is used underwater press purge button lightly or exhale sharply to expel water from the regulator
prior to inhalation.
CAUTION: Failure to purge the HEED regulator before inhaling will result in swallowing water.
4. Continue to inhale and exhale to a safe and normal rate of ascent. Take small, slow, steady breaths to
maximize the duration of air supply.
NOTE: The HEED utilizes a balanced regulator which means it will provide air in any orientation including the
regulator being upside down or sideways.
CAUTION: If HEED is used until completely empty underwater, it should be referred for five year
service.
5. When done using system, turn the On/Off Valve clockwise to turn off.

ALL INFORMATION IS PROPRIETARY AND MAY NOT BE COPIED WITHOUT WRITTEN PERMISSION OF SUBMERSIBLE SYSTEMS.
5/20
G:\Mktg\MILT\Heed 3 tech manual.hose
5
GENERAL SERVICING INFORMATION
NOTE: Ensure HEED is always pressurized whenever it is submerged to prevent water from entering system. If
HEED has been emptied of air underwater it should be referred for five year service.
NOTE: If a leak or damage is found at any point the unit should be referred for five year service.
ANNUAL CHECK: (performed by user):
1. Visually check Dial Gauge for needle to be within green zone. If it is not, perform a leak test to determine if
the HEED is actually leaking or if it just needs to be filled.
2. Look for obvious physical damage, such as broken or loose parts. Check openings of diaphragm cover for
presence of foreign objects or punctures of blue diaphragm. Check that all parts are clean and securely
attached.
3. Perform a leak test. HEED must be pressurized and needle within the green zone.
a. Completely submerge filled unit into a tub of water.
b. Shake the unit back and forth several times so that all trapped air is released.
c. Hold the unit still and watch for any leaks for 60 seconds (spend 20 seconds at each of the following:
mouthpiece opening, side ports, and tank o-ring areas).
NOTE: A leak is defined as a continuous bubble at a constant rate.
d. If leak is detected, refer unit for five year service.
FIVE YEAR SERVICE: (must be done by certified repair technician or returned to manufacturer):
1. Every five years the regulator should be overhauled with a complete overhaul kit. Refer to Service Manual for
complete instructions. Only personnel certified to repair HEED can perform the repair or refer units to the
manufacturer for servicing at: Submersible Systems
7413 Slater Ave.
Huntington Beach, CA 92647
2. DOT 3AL cylinder: Hydrostatic testing is required every five years. DOT also requires that any cylinder
exposed to fire or heat in excess of 350°F be condemned. CE marked cylinder: Refer to local country
regulations for how often hydrostatic testing should occur.
NOTE: Any cylinder that shows signs of corrosion, pitting or damage during any service checks should be
evaluated further.
ROUTINE CARE / STORAGE:
1. For general cleaning, use a mild dish soap or Simple Green / biodegradable solution.
2. For sanitizing, use a commercially available regulator sanitizer available through a dive shop.
3. Keep the threads on both the Refill Port and Refill Adapter clean and lubricated. Use high-quality, non-
toxic, food grade silicone grease for best results.
NOTE: NEVER use a hydrocarbon based oil (i.e. household oil or motor oil).
4. HEED used frequently in a water training environment need extra care:
a. After use, rinse and soak for at least 30 minutes in warm, fresh water.
b. Gently shake to dislodge any water and wipe dry with a clean towel.
c. Will require service every three to six months.
5. Store HEED full or with some positive pressure to prevent contaminants from entering the cylinder. Store in
a clean, dry environment with optimum temperatures of 50-75ºF for best product performance. Avoid direct
sunlight, automobile trunks or other areas subject to temperature extremes.
NOTE: Industry guidelines recommend replacing air in cylinders annually.

ALL INFORMATION IS PROPRIETARY AND MAY NOT BE COPIED WITHOUT WRITTEN PERMISSION OF SUBMERSIBLE SYSTEMS.
5/20
G:\Mktg\MILT\Heed 3 tech manual.hose
6
HEED 3 SPECIFICATIONS
MODEL #
175-003 / 175-004
Length
9.25" / 23.5 cm (excluding hose)
Diameter
2.25" / 5.7 cm
Weight (full)
3.1 lbs / 1.4 kg
Cylinder Pressure Rating
3000 psi / 207 bar
Cylinder Volume
1.7 cu ft / 48 liters
Duration of Air Supply
32 breaths at surface
Cylinder Material
Aluminum –black anodized
Pressure Relief
Integrated in Regulator
Regulator Type
Balanced Piston, On/Off Valve, 20” or 27” flexible braided hose &
Demand 2nd Stage
Operational Temp.
-22°F (-30°C) to +158°F (+70°C)
Burst Disc
3000 psi
Cylinder Rating
DOT 3AL 3000 or CE Marked
Duration of Breathing
Approx. 2-5 minutes. Varies upon user’s lung capacity, physical
exertion, depth of usage in water and several other factors.
This manual suits for next models
2
Table of contents
Popular Medical Equipment manuals by other brands

Bionet
Bionet FC1400 Operation manual

Healthmark
Healthmark TOSI WT101 Instructions for use

Sleep Sense
Sleep Sense ThermoCan 2-Ft Instructions for use

Hillrom
Hillrom Compella user manual

B. Braun
B. Braun Aesculap Spine Instructions for use/Technical description

Care Fusion
Care Fusion Snowden-Pencer 89-0500 manual

LifeWatch
LifeWatch ACT III Physician's Manual

Care Fusion
Care Fusion IVAC PCAM Directions for use

B. Braun
B. Braun Omni troubleshooting guide

Hillrom
Hillrom MetaNeb Instructions for use

B. Braun
B. Braun Aesculap Spine Instructions for use/Technical description

ARJO HUNTLEIGH
ARJO HUNTLEIGH Akron Streamline 2 Section Instructions for use