Sun Microsystems SUN-OPM200 Series User manual

English
User’s Manual
SUN-OPM200 Series
Fiber Optic Power Meter
Table: SUN-UM-TE-OPM004 Version: A/0
All the trademarks mentioned in this manual are registered property of Sun Telecom.
The right to interpret this manual is reserved by Sun Telecom.


F i b e r O p t i c S o l u t i o n s P r o v i d e r i
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
NOTICE
Safety Sign:
When using the optical power meter, always take bask safety precautions to
reduce the harm for the testers, and injury to persons. All the safety sign
may not mark in this manual.
Warning: Prohibited misconduct and operation, to prevent any
improper conduct and operation of the damage.
Notice: notice the important information, notification, and
references, these notice information should be understood.
Safety sign on the instrument:
WEEE Sign: Users of electrical and electronic equipment from
private households should have the possibility of returning
WEEE at least free of charge.
Safety Advice
1. When the tester use Disposable alkaline batteries, do not
charge it. Ensure the correct polarity installation, when
replace the battery.
2. When the products are not in use, please remove the
batteries and kept separate to avoid instrument damage caused by

F i b e r O p t i c S o l u t i o n s P r o v i d e r ii
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
battery leakage. If leakage occurred, Please do not touch.
3. To prevent electric shock, do not open the product case, only the
authorized qualified professionals can do the maintenance; Do not
expose the testers to rain or wet conditions, to avoid the risk of fire or
electric shock
4. Instruments used LCD screen. Do not fall the instrument. If the LCD is
seriously hit, it may cause fluid leakage. And please do not touch.

F i b e r O p t i c S o l u t i o n s P r o v i d e r iii
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
Contents
Chapter 1: Standard configuration.......................................................................1
Chapter 2: Overview............................................................................................1
Chapter 3: Specifications.....................................................................................2
Chapter 4: Function .............................................................................................3
Chapter 5 OPM Software...................................................................................14
Chapter 6 Operation Instruction and Notes.......................................................31
Chapter 7 Troubleshooting ................................................................................51
Chapter 8 General Maintenance........................................................................52
Chapter 9 Quality Warranty ...............................................................................52

F i b e r O p t i c S o l u t i o n s P r o v i d e r 1/54
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
Chapter 1: Standard configuration
No.
Product
Unit
Quantity
1
Optical Power Meter
set
1
2
AA 1.5V Battery
pieces
3
3
Power Adapter
piece
1
4
Soft Bag
piece
1
5
USB Line
piece
1
6
USB Disk
piece
1
7
FC Adapter
piece
1
8
SC Adapter
piece
1
9
ST Adapter
piece
1
Chapter 2: Overview
SUN-OPM200 Series Handheld Optical Power Meter is a newly designed
fiber optic tester, which aims at the installation, engineering acceptance and
maintenance of fiber network.
Compared with other usual power meters, this power meter has more
functions when used with SUN-LS200 Series handheld optical light source,
like automatic wavelength identification, auto wavelength switching,
intelligent backlight, data savage via USB port.
Wave ID - Auto wavelength identification & switching
Frequency ID - Auto frequency identification
2 types of backlight modes, manual or outside light intensity, which
indicated by LED light red or blue color.
Intelligent backlight
1000 records storage or download via USB cable
USB communication port for saved testing records download
Reference power level can be set up and stored
User self-calibrating function
Auto-off function

F i b e r O p t i c S o l u t i o n s P r o v i d e r 2/54
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
Up to 200hrs battery life
Chapter 3: Specifications
Model
SUN-OPM200-TC
SUN-OPM200-BC
Calibration Wavelength (nm)
850/1300/1310/1490/1550/1625
Detector type
InGaAs
Measurement Range (dBm)
-70 ~ +6
-50 ~ +26
Uncertainty (dB)
±0.15 (3.5%)
linearity (dB)
±0.02
Display resolution (dB)
0.01
Frequency ID (Hz)
270, 330, 1K, 2K
Wave ID (nm)
850, 1300, 1310, 1490, 1550, 1625
Date Storage Capacity
1000
Communication Port
USB
Standard Connector
FC /2.5mm universal
Optional Optical Connector
FC/SC/ST Interchangeable/2.5mm
universal
Optional Optical Connector
LC/FC/SC/ST Interchangeable
Alkaline battery
3*AA, 1.5V
Power Adapter (V)
8.4
Battery Operating time (h)
200 without backlight
Operation Temperature (℃)
-10 ~ +60
Storage Temperature (℃)
-25 ~ +70
Dimension (mm)
175*90*44.5
Weight (g)
231
Remark: Battery operating time is based on the condition of the power off the backlight. If
power on the backlight continuously, the operation time will be shorter.

F i b e r O p t i c S o l u t i o n s P r o v i d e r 3/54
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
Chapter 4: Function
4.1 Front
4-1
(1) Power Key
ON/OFF the instrument
Power Saving setting: the unit will automatically shut off after 15 minutes idle
time, whatever in the condition of battery power supply or AC power supply.
Once choose this setting, the “auto-off” will display on the left bottom of the
screen. This power saving is the default setting, once open the power meter,
will enter into this mode. Shortly press the power button to deactivate auto
power saving mode.

F i b e r O p t i c S o l u t i o n s P r o v i d e r 4/54
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
(2) Wavelength Selection/Wavelength Identify
Short press this key to switch the wavelength and display it on the top left of
the LCD screen, 1310nm is the default wavelength
Press the for 2 seconds, enter into wavelength auto-identify, on the
upper right of screen have “AU”, and also long press this key to quit this
function.
(3) Backlight Control (two mode of back light control, press this key to
choose one mode):
“LDR” the intelligent backlight control mode. Power meter will off/on the
backside in 15 seconds based on the outside light condition, and this is

F i b e r O p t i c S o l u t i o n s P r o v i d e r 5/54
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
the default mode back light control key mode. Press to on/off the
back light
(4) Saving/Data-view Key.
Data-saving, can save data records no more than 1000. Press screen
will display the Data saving No., tip saving the data, double press to
confirm the saving.
Data view. Long press to enter into the data view interface, short
press can view the data.

F i b e r O p t i c S o l u t i o n s P r o v i d e r 6/54
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
(5) Delete/Cancel Key.
(1) Data Deletion. When view the data, press to delete the record.
(2) Cancel the saving. When in the saving mode, press to cancel the
current data saving.
(6) Unit Switch Key
Press this key to switch between the absolute measurement (dBm), relative
measurement (dB) or xW of the optical power.
mW, dBm conversion: 10 log (mW) = (dBm)

F i b e r O p t i c S o l u t i o n s P r o v i d e r 7/54
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
mW, uW and nW conversion: 1mW=103uW=106nW
(7) REF Setting:
To store the current power value as the reference value which will be
displayed on the top right of the LCD screen, at the same time the “Ref “ also
display on the right top. It will compare the current power with the reference
power and show the relative power value in dB.
The relationships between relative value (dB), absolute value (dBm), and
Ref value: relative value=|absolute value|-|Ref|

F i b e r O p t i c S o l u t i o n s P r o v i d e r 8/54
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
(8) “B/L SET” Backlight Indicator
Indicate backlight control mode. Green light indicate that “LDR” intelligent
backlight control mode, Red light indicate that key-control mode
(9) “LDR “ Intelligent Backlight Controller
In the intelligent backlight control mode, the controller will automatically
adjust the backlight with the outside light, which to save the power.
(10) Screen
Display the data and the instrument working mode.
4.2 Two sides
4-2 left side 4-3 right side
(1) Power Supply unit port: Can connect with the AC adaptor pic. 4-4.

F i b e r O p t i c S o l u t i o n s P r o v i d e r 9/54
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
4-4
Notice: Please only use the power supply unit supplied with the
tester, use other kind of PSU may cause damage to the
instruments.
(2) USB Port.
Use the USB cable supplied to connect the Optical Power Meter to The USB
port on PC pic. 4-5.

F i b e r O p t i c S o l u t i o n s P ro v i d e r 10/54
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
4-5
4.3 Top
4-6
(1) Dust Cap
In order to protect the optical connector, avoid damage on the connector, as
a result of that, when the tester not in use, please make sure that you place
the dust cap over the connectors.
(2) Optical Connector.
The standard of this power meter connector is Φ2.5mm PC universal
connector.pic. 4-7 & 4-8.Screw off the FC connector, it will turn to Φ2.5mm
universal connector.

F i b e r O p t i c S o l u t i o n s P r o v i d e r 11/54
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
4-7 FC connector 4-8 Φ2.5mm universal connectors
Notice: When change the optical connector, take care for the
connector and the end-face. FC connector can connect with FC
adaptor; Φ2.5mm universal connector can connect with FC, SC,
and ST adaptor. Pic 4-9
4-9
Notice: the tinny dust on the connector will affect the accurate of
the measurement value, so please clean the connector and the
patch cord end-face before the test.
Use the alcohol and the cotton swab to clean the connector. Dip the cotton
swab with alcohol, insert the cotton swab in the connector, slightly rotating
the cotton swab, after that change a dry cotton swab and clean it again. Pic.
4-10.
FC Patch Cord SC Patch Cord ST Patch Cord

F i b e r O p t i c S o l u t i o n s P ro v i d e r 12/54
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
4-10
4.4 Backside
4-11
(1) Label
Content include the function, and the instrument information
(2) Bracket
Collapsible metal bracket, 0 ~ 90 degree can adjust.

F i b e r O p t i c S o l u t i o n s P ro v i d e r 13/54
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
(3) Battery Pack: 3 pieces of 1.5V AA batteries.
Notice: When insert the batteries, take a note of their positive (+)
and negative (-) connector orientation. The negative battery
connector should be against the spring. And do recycle the
battery, do not throw the battery to the dustbin, or that will cause dangerous.

F i b e r O p t i c S o l u t i o n s P r o v i d e r 14/54
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
Chapter 5 OPM Software
5.1Install the device
Run the software in the PC, find the “Driver.exe” as show in the below
Double click that “exe” program; the following will pop up (5-1).
5-1
Click “INSTALL”, after a few seconds, pop up 5-2.
5-2

F i b e r O p t i c S o l u t i o n s P ro v i d e r 15/54
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
Press “OK” to exit this install interface. However the driver still haven’t install
yet, continue the following operation:
Use USB cable connect with power meter and the PC, switch on the
instrument, and pop up 5-3
5-3
Press “NEXT”, Pop up 5-4.
This manual suits for next models
2
Table of contents
Other Sun Microsystems Measuring Instrument manuals