Sun Microsystems SUN-OPM80 Series User manual

English
User’s Manual
SUN-OPM80
Fiber Optic Power Meter
Table: SUN-UM-TE-OPM002 Version: A/0
All the trademarks mentioned in this manual are registered property of Sun Telecom.
The right to interpret this manual is reserved by Sun Telecom.

CONTENTS
1. Overview .....................................................................................................1
2. Specifications.............................................................................................1
3. Standard packages.....................................................................................2
4. Components Guide ....................................................................................3
5. Operation and Notes..................................................................................4
6. Maintenance................................................................................................6
7. Troubleshooting.........................................................................................6
8. Change Battery...........................................................................................7
9. Quality of Services.....................................................................................7

Fiber Optic Solutions Provider 1/9
www.suntelecom.cn • +86-21-60138638 • ic[email protected]
1. Overview
Sun Telecom’s SUN-OPM80 series optical power meter is a newly
developed product to meet the requirement of the market. It intergrades the
handheld optical power meter and the intelligent optical power meter in one
unit.
It can be used for the absolute optical power measurement and relative
optical loss measurement of the link loss in dB.
This power meter with compact size, friendly operation interface, broad
power measurement range, high precision performance and brand-new user
automatic calibration function and high in application makes it an ideal tool
for optical fiber network.
2. Specifications
Parameters
Specification
Model
SUN-OPM80-TC
SUN-OPM80-BC
Wavelengths (nm)
800~1700
Detector Type
InGaAs
Optical Interface
FC port (default) or FC/SC/ST interchangeable
port (customized)
Measurement Range
(dBm)
-70~6
-50~26
Uncertainty
±5%
Calibrated
Wavelengths (nm)
850/980/1300/1310/1490/1550
Display Resolution
(dB)
0.01
Alkaline Battery
3*AA 1.5V
Battery Operation
Time (Hours)
130

Fiber Optic Solutions Provider 2/9
www.suntelecom.cn • +86-21-60138638 • ic[email protected]
Auto Power off Time
(min)
10
Operation
Temperature (°C)
-10~60
Storage Temperature
(°C)
-25~70
Dimensions (mm)
152(L) x 74(W) x 26(H)
Weight (g)
160
Notes:
1 Wavelength Range: Specified standard operating wavelength range in
which the Power Meter can work properly under certain technical
specifications.
2 Power Measurement Range: The maximum and minimum range in
which the Power Meter can work properly.
3 Uncertainty: Difference between two measurement results that were
tested by Power Meter and another Standard Power Meter respectively.
3. Standard packages
Handheld Power Meter…………………………………..……………………....1
Manual………………………………………….…………………………….…1
Soft Bag………………………………..……………………………………..……1
1.5V AA Battery…………………………………………………………….……..3

Fiber Optic Solutions Provider 3/9
www.suntelecom.cn • +86-21-60138638 • ic[email protected]
4. Components Guide
(1) LCD: λ
The LCD screen displays the measurement unit in dB, dBm, nW; the
selected wavelength; the current operating situation and so on.
(2) ON/OFF Key:
Press the key to turn the unit ON or OFF.
(3) dB Key:
Test the optical power under certain wavelength.
(4) ZERO Key:
Press the key for auto-zero.
(5) “λ” Key:
Switch the current operating wavelength among 850nm, 980nm, 1300nm,
1310nm, 1490nm, 1550nm
(6) LIGHT Key:

Fiber Optic Solutions Provider 4/9
www.suntelecom.cn • +86-21-60138638 • ic[email protected]
Turn the Back-light ON or OFF.
5. Operation and Notes
1.1. ON/OFF
1) Press the On/Off key for a few seconds to turn on the unit
2) Press the On/Off key for a few seconds to turn off the unit
1.2. Absolute power measurement
1) Turn on the Power Meter
2) Press the λ key to switch between the wavelengths. The default
wavelength is 1310nm.
3) Connect the light to be measured, and then result will be displayed on
the LCD screen, including Linear and nonlinear value.
1.3. Relative power measurement.
1) Select the wavelength to be measured.
2) Under “Absolute power measurement mode”, connect to the light to be
tested.
3) Press dB key, then current power value is stored as a reference value in
dB unit. At the same time it also display the current absolute power
value and current relative value is 0dB.
4) Connect to another beam of light to be tested, display the current
relative power value and absolute power value under tested..
1.4. Special function
It has 3 kinds of working mode:
1) Factory Mode
2) User Mode
3) Working Mode
1.1.1. Factory Mode: This mode is responsible for the test and calibration
1.1.2. User Mode: Press the “λ + Light” key synchronously, and then enter
the User mode. Numeral "1" will be displayed on the top right corner.
Press the “λ + Light” key synchronously once again, it exit from the
User mode and enter the Working mode. Numeral "0" will be

Fiber Optic Solutions Provider 5/9
www.suntelecom.cn • +86-21-60138638 • ic[email protected]
displayed on the top right corner.
Function
Button
―――
Plus 0.05
Light
―――
Minus 0.05
dB
―――
Store
Zero
―――
Switch Wavelength
λ
―――
Return to the Factory Setting
λ+ Zero
―――
Notes: If any errors or mistakes caused by the user self-calibration
operation, please press the “λ+ Zero” key synchronously under the user
mode to go back to the factory setting.
1) Auto-off: Press “LIGHT + dB” key to turn on the auto-power off function.
The auto-off symbol will be displayed on the top right. The unit will be
turning off automatically after 10 minutes idle time.
2) Background light On/Off: Under the Working Mode, press LIGHT to turn
the background light On/Off. A little sun symbol will be displayed on the
top right.
Appendix:
Optical fiber loss measurement
Step 1 Optical Reference Level
Turn on optical power meter and press the λ key to select the
wavelength.
Turn on optical light source (emitting source) and select the wavelength.
Wait for 1-2 minutes until it stabilized.
Select a piece of patch cords, which is used to connect with the light
source; we call it emitting patch cords. Cleaning connector of the patch
cords. The fiber of the emitting source patch cords must be the same
fiber type as the fiber under test.
Connect the light source (emitting source) with the Handheld Power
Meter through the emitting source patch cords
Handheld Power Meter gets the power measurement value.

Fiber Optic Solutions Provider 6/9
www.suntelecom.cn • +86-21-60138638 • ic[email protected]
This value should be close to the one that light source (emitting source)
set. If it has wide disparity, please make sure the fiber connection is
clean properly or replace another jumper.
Press the dB key; the reading 0.00dB will be displayed on the screen.
The tested power values will be set to the reference value.
Step 2 Optical Loss Measurement
Keep the emitting source patch cords connection with the light source
(emitting source).
Connect the Handheld Power Meter and light source (emitting source)
to the optical fiber link respectively.
Notes: cleaning all the connectors’ end-surface including all the necessary
optical adaptors. The reading in dB unit displayed on the screen is the tested
optical fiber link loss.(also display the current absolute optical power value in
dBm unit).
6. Maintenance
1) It is important to keep all optical connectors and surfaces free from oil,
dirt or other contamination to ensure proper operation.
2) Keep using one type of adapter to avoid excess loss from different
connectors.
3) Please use dust-proof cap for protection to avoid being scratched or
contaminated when Handheld Power Meter not in operation.
4) Light interface is sensitive, please carefully plug in and pull out the
connectors.
5) Please use clean cotton to clean the sensor surface, clean it in
clockwise direction carefully.
6) If does not need to use for a long time, please take out the battery.
7. Troubleshooting
Description
Problem
Method
Faint LCD display
Battery is weak
Change battery

Fiber Optic Solutions Provider 7/9
www.suntelecom.cn • +86-21-60138638 • ic[email protected]
No display after
turning on the unit
Battery is
weak/Others
Turn on the unit
again/Change battery
Insensitive display in
LCD
Light interface is
polluted/
broken/Display locked
Check connector
carefully and clean
sensor’s interface
8. Change Battery
If you find battery is weak while operating it, please immediately turn the unit
off and change a new battery.
9. Quality of Services
Caution: Repair it in the field is NOT recommended.
18 months Warranty for Our Handheld Power Meter
SUN Telecom Warrants that every Handheld Power Meter will be free from
defects in material and workmanship for a period of 18 months. This
warranty covers the original user only and is not transferable. Should the
device fail at any time during this warranty period, We will, at its sole
discretion, replace, repair or refund the purchase price of the product.
This warranty is limited to defects in workmanship and materials and does
not cover damage from accident, acts of God, neglect, contamination,
misuse or abnormal conditions of operation or handling.
To establish original ownership and provide date of purchase, please
complete and return the registration card to Our Company. This warranty will
not go into effect until we have received the warranty registration.
A warranty registration card is included with the original shipment of
equipment. Please take a few moments to fill out the card and mail or fax it
to us to ensure proper initiation of your warranty term.

Fiber Optic Solutions Provider 8/9
www.suntelecom.cn • +86-21-60138638 • ic[email protected]
To return a defective product for warranty coverage, contact us for a written
authorization. Failure to properly protect the product during shipping may
avoid this warranty.
We will pay the return transportation fee for products repaired or replace in
warranty. Before making an repair not covered the warranty, We will
estimate cost and obtain authorization, then invoice for repair and return
transportation. We reserves the right to charge for all testing and shipping
costs incurred, if test results determine that the device is without defect.
An important message from Sun Telecom
We guarantee that any information you supply will remain confidential.
By returning this card, you will automatically be notified about updates,
modifications, and recalibration.

Fiber Optic Solutions Provider 9/9
www.suntelecom.cn • +86-21-60138638 • ic[email protected]
Warranty Registration Card
Serial Number:
Model Number:
Date of Purchase:
Company Name:
Company Address:
TEL: FAX:
E-mail:
Note: Please fax this note within one month from the date of receiving
units.
YOUR OPINION
Do you have any comments on the quality of this product or the service from
us?
This manual suits for next models
2
Table of contents
Other Sun Microsystems Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

SPL-Laboratory
SPL-Laboratory Mini Bass Meter 2018 user manual

TESTO
TESTO 480 instruction manual

Fluke
Fluke 333 Instruction card

Associated Research
Associated Research HypotMAX 7705 Operation and service manual

Craind Impianti
Craind Impianti KPO Installation, operation and maintenance manual

Omega
Omega LVCN400 Series user guide