REPLACEMENT OF CHARCOAL FILTER
ACTIVATED CHARCOAL FILTER HELPS REMOVE
HOUSEHOLD ODORS
Remove the Charcoal Filter from the Electronic Col-
lecting Cell. The Charcoal Filter
cannot be cleaned.
It
should be replaced every 3-6 months under average
conditions. These filters are available in your retail
store or through a reorder form enclosed with this unit.
TO CLEAN ELECTRONIC COLLECTING CELL
NOTE: When handling the Electronic Collecting Cell,
care should be taken to avoid damaging wires
and metal plates.
Do not wash Charcoal Filter.
Do not wash Electronic Collecting Cell in
dishwasher.
Slide out Pre-Filter located on front of the Electronic
Collecting Cell. Rinse thoroughly with clean warm
water. Set aside to dry.
Use dishwashing detergent and the hottest water
available to make a good soaking solution.
NOTE:
If the Cell is extremely dirty, spray the Cell with
a household cleaning agent such as 409,
Fantastik or Lysol. Let the Cell soak five (5)
minutes before proceeding to washing in-
structions.
Completely immerse the Cell and soak for 20 to 30
minutes in a tub or large basin. (Figure 8)
After the Cell has soaked sufficiently, the Cell should
be moved up and down to agitate the water until clean.
Thoroughly rinse both sides of the Cell.
Carefully wipe
a damp cloth along the ionizing wires.
Check to make
sure the cell plates are clean. (Figure 9) If not, gently
repeat the wash procedure described in the 3 previous
paragraphs, if necessary.
NOTE: Slight discoloration of cell plates is normal
after use.
Shake as much water out of the Cell as possible.
Replace Cell in the unit as described in the next step.
INSE
Figure 9
TO REPLACE ELECTRONIC COLLECTING
CELL AFTER CLEANING
NOTE:
Use directions on the side of the Cell for proper
placement of the filters into the Cell and for
replacing the Cell into the unit. Unit will not
operate properly if the Cell is not replaced
correctly.
Slide the Aluminum Pre-Filter in the slots provided in
the front of the Cell.
Slide the Charcoal Filter in the slots provided in the
back of the Cell.
Using the handle, slide the Cell back into the cabinet.
The cell handle must be flipped toward the back of the
Cell, so the cabinet top can be seated properly.
NOTE:
Operate the unit in
“FAN
ONLY” position for a
minimum of one hour to insure the Cell is
thoroughly dry. After the Cell is dry, unit can be
operated normally.
TO REPLACE CABINET TOP
Replace the cabinet top by positioning over the unit
and placing on cabinet. (Figure 10) Insure that the
plastic ball and socket are engaged.
Plug the cord into the electrical power source.
NOTE:
NOTE:
Operate the unit in
“FAN ONLY”
position for a
minimum of one hour to insure the Cell is
thoroughly dry. After the Cell is dry, unit can be
operated normally.
An occasional “arcing” sound is normal when
operating the unit immediately after cleaning
the Cell and should stop after a few minutes of
operation. If cleaning the Cell does notalleviate
excessive arcing, refer to the Troubleshooting
Section on page 4.
PLASTIC
BALL &&SOCKET
Figure 8
Figure
10