INSTALLATION INSTRUCTIONS FOR CENTRAX®CENTRIFUGAL FAN
NEVER EXPOSE YOUR CENTRAX®FAN TO TEMPERATURES OVER 140ºF (60ºC)
INSTALLATION
1. Install mounting brackets to fan. (Refer to Figure 1)
2. Secure mounting brackets to a fixed structure. (Refer to Figure 2)
3. Connect the Centrax®to ventilation system using 6 #6 screws (supplied) when connecting to rigid duct or 2 cable ties (supplied) when connecting to flex duct.
4. Connect to power source. (Refer to Figure 3)
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
MOUNTING HARDWARE INCLUDED
FIGURE 1: MOUNTING BRACKETS
NOTE: Rubber washer must be placed
between bracket and housing.
ELECTRICAL CONNECTIONS
FIGURE 3: WIRING DIAGRAM
1. Remove the screws from the electrical box cover plate.
2. Install the appropriate size strain relief or conduit fitting in knock-out provided on the side of the electrical box.
Run the incoming power through the strain relief or conduit and knockout.
3. Connect the incoming power according to the wiring diagram. (Refer to Figure 3)
4. Secure the strain relief and reattach the electrical box cover. The fan is now ready for use.
FIGURE 2: MOUNTING
FAN INTAKE FAN EXHAUST
Wiring diagram does not apply to units with installed cord.
MAINTENANCE
FIVE YEAR LIMITED WARRANTY
TOOLS NEEDED:
Subject to the following limitations, Suncourt Inc. (manufacturer) warrants that the Centrax® centrifugal fan will, for 5 (five) years from date of original purchase, remain free
from appearance of defects in workmanship or materials. This warranty is subject to the following limitations: (a) manufacturer’s liability is limited to the replacement or
repair of the unit, as decided by the manufacturer; (b) a defective unit must be returned, prepaid, with proof of purchase, to Suncourt; and (c) this warranty does not apply to
defects resulting from the alteration, abuse, accidental damage, unauthorized repair, or misuse of the unit. This warranty is given in lieu of all other warranties, guarantees,
and conditions on manufacturer’s part, and the manufacturer shall have no tortious or other liability in respect to this Centrax® centrifugal fan.
Actual product appearance may differ from illustrations.
Suncourt reserves the right to modify any or all of its products’ features, designs, components and specifications without notice.
GREEN OR
GREEN YELLOW
(GROUND)
BLACK (LINE)
CUSTOMER
CONNECTIONS
120VAC, 60Hz
PRE-WIRED FACTORY
CONNECTIONS
MOTOR
120VAC, 60Hz, TP
GREEN OR
GREEN YELLOW
(GROUND)
BLACK (LINE)
WHITE (NEUTRAL)
N L
WHITE (NEUTRAL)
MOTOR
120VAC, 60Hz, TP
GREEN OR GREEN YELLOW
(GROUND)
WHITE (NEUTRAL)
WIRE NUT
CAPACITOR BROWNBLACK
BLACK (LINE)
WIRING
SCHEMATIC
With the use of any electrical appliance, it is important to observe all basic precautions to minimize the risk associated with use, such as electrical shock, fire, or injury to
persons. If this unit is installed in a bathroom or kitchen, power must be supplied from a ground fault circuit interruptor (GFCI). Read these instructions before using your
Centrax®fan.
CAUTION: Before carrying out any maintenance or servicing, ensure the unit is disconnected from the main supply.
FOR GENERAL VENTILATION USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS OR DUST.
Use supply wires suitable for 105°C.
a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely fasten a prominent warning device such as a tag to the service panel.
c) Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
d) When cutting or drilling into walls or ceilings, avoid damaging electrical wiring and other hidden utilities.
e) Ducted fans must always be vented to the outdoors.
f) If this unit is to be installed over a tub or shower, it must be marked appropriately for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) protected
branch circuit.
g) NEVER place a switch where it can be reached from a tub or shower.
h) When used in an attic, install exhaust side of the fan facing an unoccupied space.
i) This unit has an unguarded impeller. Do not use in locations readily accessible to people or animals.
j) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating
equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
TF104(-W) Qty. 4 Qty. 4 Qty. 4 Qty. 4 Qty. 4 Qty. 4
Qty. 8
Qty. 2
Qty. 8 Qty. 8 Qty. 8 Qty. 8 Qty. 8 Qty. 4
Qty. 8 Qty. 8 Qty. 8 Qty. 8 Qty. 8 Qty. 8 Qty. 4
Qty. 2
TF110 & TF112
TF106 & TF108
Model
#8 x 1"
Self Tapping
Screw
#8 x 5/8"
Machine
Screw
Model
Hex Nut #6 Lock
Washer Flat
Washer Mounting
Bracket
Rubber
Washer
#10 x 1"
Self Tapping
Screw
#10 x 5/8"
Machine
Screw
Hex Nut #10 Lock
Washer Flat
Washer Mounting
Bracket
Rubber
Washer
#6 Screws For Securing Rigid Duct Connection (Included in all units)
Cable Ties For Securing Flex Duct Connection (Included in all units)
Qty. 6
Inspect the product at least once every 12 months for excessive dust and dirt build-up on the impeller (more frequently in dusty environments). Clean as necessary.
The unit must be disconnected from power during inspection and/or cleaning.
SUNCOURT INC.
500 W. SECOND AVENUE • P.O. BOX 40
DURANT, IOWA 52747-0040
1-800-999-FANS (3267)
www.suncourt.com
SAFETY WARNING! PLEASE READ CAREFULLY
SAVE THESE INSTRUCTIONS
INSTALLATION INSTRUCTIONS FOR VARIABLE SPEED FAN CONTROL
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, INJURY, OR DEATH, OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel. Suncourt Inc. does not provide electrical connection
information. For your safety and protection follow all instructions and adhere to applicable building and/or electrical codes.
WARNING - Unit should be installed by a qualified electrician in accordance with the National Electrical Code and other local codes which may apply. Failure to follow these
instructions may result in electrical shock, fire hazard, or death. To reduce these risks, this control is to be used only with fans marked as suitable for use with solid state
speed controls. This control is suitable for mounting in an approved metal or polymeric field enclosure. These controls must not be used at ratings exceeding those clearly
marked on the device. If unit is installed in a bathroom or kitchen, power must be supplied from a ground fault circuit interruptor (GFCI).
SAFETY WARNINGS - PLEASE READ CAREFULLY - This product should be installed and serviced by a qualified technician, electrician or electrical maintenance
personnel familiar with its operation and the hazards involved. Proper installation, which includes wiring, mounting in proper enclosure, fusing or other overcurrent protection
and grounding, can reduce the chance of electrical shocks, fires or explosion in this product or products used with this product, such as electric motors, switches, coils,
solenoids and/or relays. This product is constructed of materials (plastics, metals, carbon, silicon, etc.) which may be a potential hazard. Proper shielding, grounding and
filtering of this product can reduce the emission of radio frequency interference (RFI) which may adversely affect sensitive electronic equipment. If information is required on
this product, contact our factory. It is the responsibility of the equipment manufacturer and individual installer to supply this safety warning to the ultimate user of this product.
1 Application
a) Motor type - shaded pole, P.S.C, and universal.
b) Required load - fans, blowers and speed dependent loads.
2 Wiring
Warning! Power must be turned off before wiring. Connect control
in series with motor and line voltage; never connect control across line.
Connect black lead from control to black lead of incoming 120 VAC power.
Connect white lead from control to black lead of fan.
Ground - Be sure fan is electrically grounded.
(See wiring diagram for details.)
3 Minimum Speed Adjustment (Located on side of black control box)
REASONABLE AIRFLOW MUST BE MAINTAINED TO PROVIDE SUFFICIENT COOLING OF THE MOTOR. WHEN USING WITH SUNCOURT CENTRAX CENTRIFUGAL
FANS, THIS CAN BE ACHIEVED BY ENSURING THAT THE MINIMUM SPEED ADJUSTMENT IS NOT LESS THAN 1200 RPM.
This control was designed to operate on motors used in diverse applications. A minimum speed adjustment is provided to allow independent control of the minimum speed
setting. Minimum speed adjustment ensures motor runs with sufficient torque to prevent stalling.
a) Motor must be in actual operating position to achieve proper speed adjustment. Motor will not slow down unless proper load is applied.
b) Turn main control knob to lowest speed position.
c) Locate and adjust minimum speed setting on the side of control with screw driver (rotate clockwise to increase minimum speed; counter-clockwise to decrease minimum
speed).
Note: On low speed you may experience a slight motor hum. If level is unacceptable, the speed setting may be altered to reduce the hum.
d) Motor will now operate from this preset minimum speed to full speed.
4 Mounting
a) Use 2” deep standard approved electrical box. (field supplied)
5 Final Mounting
a) Install front dial plate (remove protective plastic on face of dial plate).
b) Turn main control until switch clicks off.
c) Push on knob so that pointer is in off position.
120 VAC
POWER
LINE (BLACK)
NEUTRAL (WHITE)
WHITEBLACK
(BLACK)
L1
L2
FAN
OFF LOW
WARRANTY
Subject to the following limitations, Suncourt Inc. warrants that the Variable Speed Fan Control will, for 1 (one) year from date of original purchase, remain free from
appearance of defects in workmanship or materials, when installed in accordance with all applicable codes and standards in the application for its designed and specified
use. This warranty is subject to the following limitations: (a) manufacturer’s liability is limited to the replacement or repair of the unit, as decided by the manufacturer; (b) a
defective unit must be returned, prepaid, with proof of purchase, to Suncourt; and (c) this warranty does not apply to defects resulting from the alteration, abuse, accidental
damage, unauthorized repair, or misuse of the unit. This warranty is given in lieu of all other warranties, guarantees, and conditions on manufacturer’s part, and the
manufacturer shall have no tortious or other liability in respect to this Variable Speed Fan Control.
SUNCOURT INC. • P.O. BOX 40 • DURANT, IOWA 52747-0040 • 1.800.999.FANS (3267) • WWW.SUNCOURT.COM