Data in the tables are for
indicative purposes.
Draught depends on the diameter,
height, uneven sections along the
chimney surface and differences
in temperature of combustion
products and outside air. We
recommend that you use chimney
fitted with flue terminal. Heating
specialist must calculate the
precise sizing of the chimney.
Werecommendthatthestovebeinstalled
as close as possible to the system’s
exhaustgasextractionsystem(theflue).
The maximum permitted length of duct
pipebetweenthestoveandtheflueis3
m, whereas no horizontal section longer
than0.5misallowed.
7.2. Type of tubes for exhaust gas system
(chimney)
The tubes must be solid, smooth inside,
madofsteelandmustbeaccompaniedby
siliconegaskets.
The diameter of tubes long up to 3 m.
must be 80 mm. The diameter of tubes
long more than 3 m. must be minimum
100mm.asitis necessarytoobtainthe
requireddraughtofthechimney.
Do not connect the exhaust gas
system to a chimney in which
already is connected another
stove, boiler or ventilation
system!
7.3. Connecting of outer tube for fresh
air flow
For proper functioning and distribution
ofthetemperaturethepelletstovemust
receive enough fresh air flow and to be
well positioned (a special opening for
freshaircouldbedoneforexample).
The flue opening area should be at
least 100 cm2. If the premises has an
air outflow/suction system installed, a
relevantfreshairinflowmustbeprovided
for.
Thismaybecarriedoutthroughproviding
continuous ventilation from another
premises with no fireplace or other air-
intakingsysteminoperation.
Such premises exclude bedrooms,
bathrooms, or premises with increased
fire hazard, such as garages, basements,
orflammablematerialstoragerooms.
Ifsuchroomhasalreadyanotherheating
appliance installed (e.g. a fireplace,
a heater etc.) or another source of
hazardousgases,thenthenewstovemust
beprovidedwithanadditionalsourceof
freshairfromoutdoors.
The same provision goes for any
subsequentlyaddedheatingdevices.
Example: Connection of tube for fresh air
flow directly from the outside
For proper functioning of the pellet stove
it is recommended to make a direct
connection from outside the room with
steel pipe 80 мм. with silicon gasket. The
part of the tube that goes outside the
room must be situated downwards 90° - in
this way a protection against wind, water,
etc. is achieved.
Uponsuchdirectconnectionthefollowing
distancesshouldbeobserved:
-1.5mfromthefloor
-1.5mfromhorizontalductingsection
-0.3mfromdoorsandwindows,whereas
pipesmustrunabovethem
-2.0mfromtheexhaustgassystem.