Sunx LX-100 User manual

To detect any marking, this unit is
equipped with red, green and blue LED
light emitting elements all in one.
SUNX’s unique coaxial reflective optics
technology ensures very accurate
sensing. The unit is made with a
scratchproof glass lens.
Half mirror
Glass lens
High precision coaxial
reflective optical system
New Advanced sensor with Visible Indicator
R•G•B light emitting
elements all in one
The sensor’s basic operations are represented by 6 indicator lamps
(MODE NAVI). The user can check what mode the sensor is presently in
with a quick glance rendering operation simple.
To detect any marking, this unit is
equipped with red, green and blue LED
light emitting elements all in one.
SUNX’s unique coaxial reflective optics
technology ensures very accurate
sensing. The unit is made with a
scratchproof glass lens.
Newly
developed
Total reflection
mirror
Can detect any mark!
1
Downloaded from Arrow.com.Downloaded from Arrow.com.

To detect any marking, this unit is
equipped with red, green and blue LED
light emitting elements all in one.
SUNX’s unique coaxial reflective optics
technology ensures very accurate
sensing. The unit is made with a
scratchproof glass lens.
4-digit digital display
Operation panel
12-bit A/D converter
Receiving element
Protection IP67
2 selectable sensing modes for any application
d
Image schematic
The sensor utilizes all 3 RGB LEDs to convert the
reflective light into an RGB ratio. Only the color of
the mark indicated by teaching is accurately
detected.
The sensor automatically selects the most suitable
light source color from the 3 RGB LEDs offering
the largest contrast between the mark and base
(non-mark area). The sensor effectuates ultra quick
mark detection with a 45 !s response time.
Color modeMark mode
A resolution of 1/4000 is realized to
enable high precision mark sensing.
3 large buttons that click into position
making operation easy.
The 4-digit digital display enables
numerical sensing control and minute
settings.
Washing the machines and production
line with water will not affect the sensor
thanks to its waterproof construction.
Highest in
the industry
Color modeMark mode
R (red) LED lit G (green) LED lit B (blue) LED lit All 3 R•G•B LEDs lit
Coaxial reflective optics and a sharp
15 mm 0.0390.197 in spot enable
high precision sensing.
2
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

RED
GREEN
BLUE
RED
GREEN
BLUE
Various functions to ensure the best mark sensing.
Sensing modes can be selected depending on the application.
Mark mode
Automatic optimal LED selection function
The 3 colors of the R•G•B LEDs are optimally selected according to the color combination. With the LX-100’s Mark mode, the built-in
‘Automatic optimal LED selection function’automatically selects the LED for the largest contrast (S / N ratio) between the mark and base (non-
mark area) to ensure optimal sensing. For more stable detection, the sensor makes selection according to the contrast and not according to
the reflected light variation between the mark and base (non-mark area).
With mark sensing, the larger the received light
variation is, the easier sensing becomes. Also, the
higher the received light ratio (contrast) is, the
more sensing is stabilized. The example on the
right deals with reflected light on packing film.
Great figures are indicated for the blue LED’s light
amount ratio and, for even more stable sensing, the
blue LED effectuates this mark sensing.
The LX-100 series sensors automatically selects
the optimal LED that will ensure the most stable
sensing results.
Mark
Light amount =
ratio
Base
6 : 8 Mark
Light amount =
ratio
Base
8 : 4 Mark
Light amount =
ratio
Base
4 : 1
Optimal
Mark
Has a built-in ‘Mark mode’ that realizes a ultra quick 45 ¨s response time as well as a ‘Color mode’
offering the best mark color discrimination capacity. Use either of these modes as per the application.
This sensing mode automatically selects a single
color from the 3 R•G•B LEDs to realize an ultra
quick 45 !s response time. The automatic optimal
LED selection function automatically selects the LED
that is most suitable for the sensing. This function is
perfect for ultra quick sensing.
Reflective light
Reflective light
Reflective light
Automatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selection
3
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

RED
GREEN
BLUE
The color around letters is
detected as a mark.
Predetermined colors are
detected as marks.
Even similar colors are accurately determined using the R•G•B ratio.
3.
Precise determination of consistency of the spot color (R•G•B ratio)
2. R•G•B ratio calculated1.
1-level teaching for this mark
Color mode
High precision mark color discrimination
The color mode on the LX-100 series utilizes all 3 R•G•B LEDs to determine the R•G•B ratio of the mark color. The built-in 12-bit A/D
converter enables high precision 1/4000-resolution judgments.The figure below is a graphic description of this process.
:: 61015
:: 51015
:: 51013
a
Inconsistent
b
Consistent
c
Inconsistent
R
G
B
:
:
:
15
10
5
a c
b
b
MarkMarkMark
All 3 R•G•B LEDs light up and high precision mark color
discrimination occurs using the R •G•B reflective light
ratio.This function enables effective detection of films with
patterns around the area of the mark.
Reflective light
Automatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selectionAutomatic selection
4
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

Its digital display makes for easy settings!
Numerical control of the settings possible
New Advanced sensor with Visible Indicator
4-digit digital display
Light-receiving amount and
setting values are displayed.
MODE indicator
OFF key
(PRO mode:ENTER key)
ON key
(
PRO mode:SELECT key)
MODE indicator
MODE key
(PRO mode:CANCEL key)
Operation indicator
Selected LED: Red LED
Threshold value: 600
•Example of sensor setting indication
Selected LED: Green LED
Threshold value: 1850 Selected LED: Blue LED
Threshold value: 1600
This is the sensing mode. The digital display
shows the light-receiving amount (mark mode)
and the color consistency (color mode).
This mode enables a mark
mode / color mode selection.
RUN
Even beginners can quickly master MODE NAVI operation
The sensor’s basic operations are represented by 6 indicator lamps (MODE NAVI).The user can check what mode the sensor is presently in
with a quick glance rendering operation simple.
Sensing status digitally controllable
The sensing status, displayed numerically,
can be verified at a glance. Also, the sensor
settings for each type of packing film can be
digitally indicated.
This is the threshold value
setting (teaching) mode. TEACH
This is the threshold fine-
adjustment mode.
Timer type selection mode.
This mode enables the setting
of various functions such as
key lock and timer period.
ADJ
COLOR
TIMER
PRO
The 4-digit digital display enables easy verification of received light from marks and
base (non-mark area). Also, the threshold value can be controlled numerically
enabling setting indication easily. Displaying the direct code enables settings
verification.This function is handy for remote maintenance.
( )
5
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

1st digit :Mark mode (green LED)
2nd digit :
Standard display / ECO mode disabled /
Reverse display disabled
3rd digit : Key lock mode FULL / No timer
4th digit :Timer period set at 20 ms
The above represent default settings.
2-level teaching and full-auto teaching possible
External teaching possible
Teaching is possible by external input using the operation panel or
touch panel even for color mark sensors whose position within the
equipment is out of reach. Models can be easily interchanged.
Direct codes enable settings verification at a glance
The settings for the LX-100 series sensors are displayed using a
4-digit direct code.Direct codes enable easy settings verification and
maintenance by phone.
Super simple teaching
Press the ON button at the targeted mark.
We provided an example of the most basic setting method‘2-level teaching’.
mFor details, refer to p.7 ‘Direct code table’
Direct code display example
The LEDs light up in order and each LED’s reflected
light is checked instantaneously.
The LEDs light up in order and each LED’s reflected
light is checked instantaneously.
Mode selection
Press MODE key and select TEACH mode.
Sensing
Teaching 1
Align the spot on the mark and press the ON key.
2
Align the spot onto the base (non-mark area) and press the OFF key.
mThe 12order can be reversed.
Display showing
complete settings
Mark
Mark mode
1-level teaching possible
Color mode
Spot
Base
Spot
1
2
What is the
direct code?
The direct code is 0004.At present,
the sensor is operating with a mark
at 2300 and base at 860.
Teaching complete. The optimal LED is
automatically selected and the sensor
automatically returns to RUN mode.
•
•
Full-auto teaching: In Mark mode, teaching is effectuated without
stopping the sensing object.
1-level teaching: In Color mode, the color detected is aligned by the
spot and teaching is effectuated.
Other teaching methods
6
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

7
Direct code table (D-Code)
The key lock function enables input operation control that prevents
mistaken changes in the sensor settings. Also possible are minute
settings such as ‘RUN adjust’, allowing threshold value adjustment
only, and ‘RUN teaching’, allowing teaching operation only.
If setting the sensor to ‘RUN adjust’or ‘RUN teaching’, adjustments
and teaching is possible with the sensor left in RUN mode.
Key lock function Timer function
The built-in timer function cancels signals not needed for mark
sensing and lengthens the width of signals to control devices.
mThe key lock function is enabled by pressing the MODE key and OFF key
simultaneously for at least 2 sec. after having effectuated settings. Press the
MODE and OFF keys again simultaneously for at least 2 sec.to release.
• ON-delay and OFF-delay timers built-in
• 9 timer levels available: 1 ms / 2 ms / 5 ms / 10 ms / 20 ms / 50 ms / 100 ms /
200 ms / 500 ms
High precision sensing and multiple functions provided all in a
compact W57D24H38 mm W2.244D0.945H1.496 in
body. Cable and plug-in connector types are available depending on
the equipment used. These sensors can be easily introduced to
already existing facilities.
Compact design for significant space savings
•
Built-in output 1 (OUT) and output 2 (OUT)
• Built-in teaching input
• NPN and PNP output types available
• With 5-core cable
• Built-in teaching input
• NPN and PNP output types available
• Straight and elbow type M12 plug-in
connector cables available (optional)
Plug-in connector type
Cable type
M12 plug-in connector cable
Other features and handy functions
Timer period
Timer mode
Turn mode (Note 5)
ECO mode (Note 4)
Key lockDisplay mode2nd digit 3rd digit 4th digit1st digit
Display
1 ms
2 ms
5 ms
10 ms
20 ms
50 ms
100 ms
200 ms
500 ms
non
OFF-delay
ON-delay
non
OFF-delay
ON-delay
non
OFF-delay
ON-delay
OFF
ON
OFF
ON
OFF
ON
OFF
ON
FINE
COARSE
FINE
COARSE
FINE
COARSE
FINE
COARSE
FINE
COARSE
FINE
COARSE
FINE
COARSE
FINE
COARSE
L-ON
D-ON
L-ON
D-ON
L-ON
D-ON
Consistent-ON
Inconsistent-ON
OFF
ON
OFF
ON
Mark mode (green)
Mark mode (blue)
Mark mode (red)
Color mode
Standard Full lock
(All operations disabled)
RUN teaching
(Teaching only enabled)
Threshold value
adjustment only enabled
RUN adjust
Display
DisplayDisplay
Sensing mode (light source color)
Operation mode (Note 1)
Sensing (Note 2)
38 mm
1.496 in
24 mm
0.945 in
57 mm
2.244 in
Press at least 2 sec.
The sensor setting modes can be verified by a 4-digit code
(D-Code).The table below shows a list of all available codes.
Percent display
(Note 3)
( )
Notes: 1)
2)
3)
4)
5)
mDefault setting: D-code ‘’.
In Mark mode, L-ON / D-ON is automatically set in the sensor. For example, with 2-level teaching, press the ON key at the targeted mark and press the
OFF key at the base (non-mark area).When doing so, the operator does not have to consider L-ON / D-ON.
Sensing accuracy can be set to either FINE (standard) or COARSE.
The percent display is only enabled in mark mode.
ECO mode is a function that reduces power consumption by turning off the digital display in the event no button operations are made for a
predetermined time (approx. 10 sec. or more) in RUN mode. Press any button to turn the digital display on again.
The turn mode is a function that reverses the digital display making it easily viewed in the event the sensor installation renders the display up-side-down.
● When in RUN mode, press the MODE
key for at least 2 sec. to display the
direct code. (Remove your finger from
the MODE key and the direct code will
disappear.)
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

8
LX-100
103 mm
0.3940.118 in
ORDER GUIDE
OPTIONS
AppearanceType Sensing rangeOutputModel No.
LX-101
LX-101-P
LX-101-Z
LP-101-P-Z
Sensors
Type
Elbow
Straight
Cable type
Plug-in connector
type
0.34 mm24-core cabtyre cable,
with connector on one end
Cable outer diameter: "5 mm "0.197 in
DescriptionModel No.
NPN open-collector
transistor
PNP open-collector
transistor
NPN open-collector
transistor
PNP open-collector
transistor
CN-24B-C2
CN-24B-C5
CN-24BL-C2
CN-24BL-C5
Length: 2 m 6.562 ft
Length: 5 m 16.404 ft
Length: 2 m 6.562 ft
Length: 5 m 16.404 ft
Mating cables for plug-in connector type sensor
Type
MS-LX-1
MS-LX-2
Sensor mounting
bracket
Sensor mounting brackets
• MS-LX-1
Mating cables for plug-in connector type sensor
Two M4 (length 28 mm 1.102 in) screws with
washers are attached.
• MS-LX-2
Two M4 (length 30 mm 1.181 in) screws with
washers are attached.
"14 mm
"0.551 in
31 mm
1.220 in
"5 mm
"0.197 in
29 mm
1.142 in
"14 mm
"0.551 in
"5 mm
"0.197 in
43.5 mm
1.713 in
• CN-24B-C2
• CN-24B-C5 • CN-24BL-C2
• CN-24BL-C5
Mating cable is not supplied with the plug-in connector type. Please order it separately.
Mating cable is not supplied with the plug-in connector type sensor. Please order it separately.
DescriptionModel No.
Mounting bracket made for
LX-100 series applicable for
various kinds of installations
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

9
LX-100
SPECIFICATIONS
LX-101
LX-101-P
Cable type
Type
PNP output
NPN output
Model No.
LX-101-Z
LX-101-P-Z
Plug-in connector type
Item
Sensing range
Spot size
Supply voltage
Current consumption
Output 1
(OUT)
Protection
Ambient temperature
Ambient humidity
Ambient illuminance
Voltage withstandability
Vibration resistance
Shock resistance
Short-circuit protection
Output operation
Short-circuit protection
Output operation
10 3 mm 0.394 0.118 in
15 mm 0.0390.197 in (at 10 mm 0.394 in setting distance)
12 to 24 V DC 10 % Ripple P-P 10 % or less
Response time
Teaching input
Mark mode: 45 !s or less, Color mode: 150 !s or less
Digital display
Sensitivity setting
Fine sensitivity adjustment function
Timer function
Emitting element
Material
Cable
Cable extension
Weight
Accessory
4-digit red LED display
Mark mode: 2-level teaching / Full-auto teaching, Color mode: 1-level teaching
Incorporated
Incorporated with variable ON-delay / OFF-delay timer, switchable either effective or ineffective (Timer period: 1 to 500 ms, 9 levels variable)
IP67 (IEC)
10 to 55 C 14 to 131 F (No dew condensation or icing allowed), Storage: 20 to 70 C 4 to 158 F
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 #x at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3.0 mm 0.118 in double amplitude (max. 20 G) in X, Y and Z directions for two hours each
500 m/s2acceleration (50 G approx.) in X, Y and Z directions for three times each
Combined Red / Green / Blue LEDs (Peak emission wave length: 640 nm 0.025 mil / 525 nm 0.021 mil / 470 nm 0.019 mil)
Enclosure: PBT, Display: Polycarbonate, Operation buttons: Silicone rubber, Lens: Glass, Lens holder: Aluminum
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
M4 (Length 30 mm 1.181 in) screw with washers: 2 pcs.
Incorporated
Mark mode: Light-ON / Dark-ON (Auto-setting on teaching), Color mode: Consistent-ON / Inconsistent-ON (Setting on teaching)
Incorporated
Inverted operation of the output 1
Note: Mating cable is not supplied with the plug-in connector type. Please order it separately.
Environmental resistance
<NPN output type>
NPN open-collector transistor
• Maximum sink current: 50 mA
•
Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less (at 50 mA sink current)
<PNP output type>
PNP open-collector transistor
• Maximum source current: 50 mA
•
Applied voltage: 30 V DC or less (between output and V)
•
Residual voltage: 1.5 V or less (at 50 mA source current)
<NPN output type>
NPN open-collector transistor
• Maximum sink current: 50 mA
•
Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less (at 50 mA sink current)
<PNP output type>
PNP open-collector transistor
• Maximum source current: 50 mA
•
Applied voltage: 30 V DC or less (between output and V)
• Residual voltage: 1.5 V or less (at 50 mA source current)
<NPN output type>
NPN non-contact input
• Signal condition: High5 V to V, or open
Low 0 V to 2 V
(source current: 0.5 mA or less)
• Input impedance: 10 kΩapprox.
<NPN output type>
NPN open-collector transistor
• Maximum sink current: 100 mA
•
Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less (at 100 mA sink current)
<PNP output type>
PNP open-collector transistor
• Maximum source current: 100 mA
•
Applied voltage: 30 V DC or less (between output and V)
•
Residual voltage: 1.5 V or less (at 100 mA source current)
0.34 mm25-core cabtyre cable, 2 m 6.562 ft long (Note)
Net weight: 120 g approx., Gross weight: 180 g approx. Net weight: 55 g approx., Gross weight: 120 g approx.
Output 2
(OUT)
<PNP output type>
PNP non-contact input
• Signal condition: High4 V to V
(sink current: 3 mA or less)
Low 0 V to 0.6 V, or open
• Input impedance: 10 kΩapprox.
Normal mode: 750 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

10
LX-100
I/O CIRCUIT ANDWIRING DIAGRAMS
SPOT SIZE CHARACTERISTICS (TYPICAL)
NPN output type
I/O circuit diagrams
Users’circuitInternal circuit
D1
D2
Color code of cable type /
mating cable for plug-in connector type
(Brown) V
(Black) Output 1
50 mA max.
50 mA max. (Note 1)
(White) Output 2 (Note 2)
ZD1
ZD2
(Blue) 0 V
Tr1
Tr2
10 kΩ
D2
10 kΩ
(Pink) Teaching input
m1
5 V
Load
Load
3
1
Terminal No. of plug-in connector type
12 to 24 V DC
10 %
Notes: 1)
The current of the plug-in connector type LX-101-Z is 100 mA max.
2)
The output 2 is not incorporated to the plug-in connector type LX-101-Z.
Notes: 1)
The current of the plug-in connector type LX-101-Z is 100 mA max.
2)
The output 2 is not incorporated to the plug-in connector type LX-101-Z.
m1
Non-voltage contact or NPN transistor
or High:5 V to V, or open
Low:
0 V to 2 V (source current: 0.5 mA or less)
Users’circuitInternal circuit
Sensor circuit
PNP output type
ZD1
ZD2
(Brown) V
(Pink) Teaching input
D1
Tr1
Tr2
50 mA max. (Note 1)
50 mA max.
(Black) Output 1
(Blue) 0 V
(White) Output 2
(Note 2)
0 V
m1
Color code of cable type /
mating cable for plug-in connector type
12 to 24 V DC
10 %
4
1
Load
Load
Terminal No. of plug-in connector type
m1
Non-voltage contact or PNP transistor
or High:4 V to V (sink current: 3 mA or less)
Low:0V to0.6 V, or open
I/O circuit diagrams
3
Layout of connector pin of plug-in connector type
(Unit: mm in)
2 0.079
1.7 0.067
1.2 0.047
1.0 0.039
1.3 0.051
1.5 0.059
2.0 0.079
7 0.276
8 0.315
9 0.354
10 0.394
11 0.433
12 0.472
13 0.512
Setting distance L
(Note 1)
Width (W)
Spot size (Note 2)
V
Teaching input
0 V
Output
1
2
3
4
Connector pin No.
Description
5.5 0.217
5.5 0.217
5.3 0.209
5.0 0.197
5.0 0.197
5.0 0.197
5.0 0.197
Length (D)
3
4
2
1
V
0 V
LD
W
4
2
2
Sensor circuit
Symbols... D1, D2: Reverse supply polarity protection diode
ZD1, ZD2: Surge absorption zener diode
Tr1,Tr2: NPN output transistor
Symbols... D1, D2: Reverse supply polarity protection diode
ZD1, ZD2: Surge absorption zener diode
Tr1,Tr2: PNP output transistor
Notes: 1)
2)
Setting distance ‘L’represents the
distance from the lens surface to
the sensing object.
Examples only meant for use as a
guideline.
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

LX-100
11
At mark mode setting:
Sets the threshold value by
‘2-level teaching’or ‘full-auto
teaching’.
At color mode setting:
Sets the threshold value by
‘1-level teaching’.
PRECAUTIONS FOR PROPER USE
• Care must be taken regarding the sensor mounting direction with
respect to the object’s direction of movement.
• The tightening torque should be 0.8 Nm or less.
Mounting
Part description
Sensing glossy object
Operation indicator
(Orange) MODE indicator
(Green /Yellow) MODE indicator (Yellow)
4-digit digital display
(Red)
MODE key
(PRO mode:CANCEL key)
ON key
(PRO mode:SELECT key)
OFF key
(PRO mode:ENTER key)
At mark mode setting:
Allows fine adjustment of the
threshold value.
At color mode setting:
Allows adjustment of sensing
tolerance value.
Adjust
Teaching
TEACH
At mark mode setting:
Indicates the absolute value of light-
receiving amount. It is possible to
indicate the relative value (percent
value) against threshold value.
At color mode setting:
Indicates color consistency
with relative value.
Run
RUN
NAVI mode PRO mode
Configures operation of the timer.
Timer operation setting
TIMER
Allows various detailed
settings to be configured.
PRO
PRO
Sets mark mode or color mode.
Mark / Color mode setting
COLOR
Sets the sensing level
(hysteresis).
Sensing setting
Sets timer setting period by
9-levels.
Timer period setting
Selects the type of key lock
function.
Key lock setting
Selects display method of
digital display.
Display setting
Sets ON / OFF of ECO mode.
ECO setting
Changes display direction of
digital display.
Display inverting mode setting
Resets to factory setting.
Reset setting
Sensor mounting bracket
MS-LX-1 (Optional)
M4 (length 28 mm 1.102 in)
screw with washers
Do not make the sensor
detect an object in this
direction because it
may cause unstable
operation.
Mark and base Mark and base
• Press the ‘ON key’when selecting settings. To confirm selected settings, press the
‘OFF key’. The digital display will flash to indicate successful confirmation of settings.
To cancel settings, press the ‘MODE key’.
ADJ
Sensing level: Standard Sensing level: Coarse
(50 ms) (500 ms)(100 ms) (200 ms)(20 ms)
(2 ms) (1 ms)(5 ms)(10 ms)
Full lock
Set full key lock
RUN adjust
Set key lock except
for RUN adjust mode
RUN teaching
Set key lock except
for RUN teaching mode
At mark mode setting: Displays light-receiving amount
At color mode setting: Displays color consistency
At mark mode setting: Percentage display with
respect to the threshold value
At color mode setting: Displays color consistency
ECO setting: ONECO setting: OFF
Invert the display.Not invert the display
Reset the settings
Not reset the settings
TABLE FOR PRO MODE SETTINGS
•
This catalog is a guide to select a suitable product.Be sure to read
the instruction manual attached to the product prior to its use.
This product is not a safety sensor. Its use is not
intended or designed to protect life and prevent body
injury or property damage from dangerous parts of
machinery. It is a normal object detection sensor.
•
•
• Before performing teaching or each detail setting, perform the
setting of either mark mode or color mode with mark / color
mode setting of NAVI mode.
Objects with a glossy surface have a large amount of specular
reflection particles that may destabilize sensing. In such a case,
by slightly tilting the sensor’s beam axis, this specular reflection
can be reduced rendering sensing more stable.
If the surface of the sensing object has a shine,
mount the sensor inclining approx. 10 to 15
degrees against the sensing object.
10 to 15
Press the OFF (ENTER)
key to confirm
Press the OFF (SELECT)
key to move (select)
Press the MODE
key to cancel
Press the OFF
(ENTER) key
to move (enter)
Press the MODE
key to cancel
Press the MODE
key to move
<Correct> <Incorrect>
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

12
LX-100
DIMENSIONS (Unit: mm in)
COLOR CHART [The color notations are based on the C (cyan) / M (magenta) /Y (yellow) / BL (black) format used for printing.]
LX-101
LX-101-P Sensor LX-101-Z
LX-101-P-Z Sensor
MS-LX-1 Sensor mounting bracket (Optional) MS-LX-2 Sensor mounting bracket (Optional)
5
0.197
1.5
0.059
2-"4.5 "0.177
mounting holes
5
0.197
3
0.118
2-R5 R0.197
4-R2 R0.079
R2 R0.079
3-M50.8 0.031
R2
R0.079
3-R2 R0.079
2-M40.7 0.028
R4.7 R0.185
2-R4.7
R0.185
2-R5 R0.197
2-"4.5 "0.177
mounting holes
M12
5
0.197
1.5
0.059
3
0.118
9.4
0.370
"14.4
"0.567
5
0.197
71.5
2.815
Note: Fading after printing may cause color variations.Use the above chart as a guideline.
M : 100Y : 100
M : 100Y : 50
M : 100
C : 50 M :100
C : 100 M :100
C : 100Y : 50
Y : 100
M : 50Y : 100
BL : 100
M : 80Y : 80 M : 80Y : 40 M : 80 C : 40 M : 80 C : 80Y : 40 Y : 80 M : 40Y : 80 BL : 80
M : 60Y : 60 M : 60Y : 30 M : 60 C : 30 M : 60 C : 60Y : 30 Y : 60 M : 30Y : 60 BL : 60
M : 40Y : 40 M : 40Y : 20 M : 40 C : 20 M : 40 C : 40Y : 20 Y : 40 M : 20Y : 40 BL : 40
M : 20Y : 20 M : 20Y : 10 M : 20 C : 10 M : 20
C : 80 M : 80
C : 60 M : 60
C : 40 M : 40
C : 20 M : 20
C : 100 M : 50
C : 80 M : 40
C : 60 M : 30
C : 40 M : 20
C : 20 M : 10
C : 100
C : 80
C : 60
C : 40
C : 20 C : 20Y : 10
C : 100Y : 100
C : 80Y : 80
C : 60Y : 60
C : 40Y : 40
C : 20Y : 20
C : 50Y : 100
C : 40Y : 80
C : 30Y : 60
C : 20Y : 40
C : 10Y : 20 Y : 20 M : 10 Y : 20 BL : 20
5
0.197 5
0.197
25
0.984
2-M50.8 0.031
4-M40.7 0.028
15
0.591
5
0.197
5
0.197
3
0.118
3
0.118
4
0.157 6
0.236
10
0.394 4
0.157 R2 R0.079
6
0.236
9
0.354
2-R5
R0.197
Material: Stainless steel (SUS)
Two M4 (length 28 mm 1.102 in) screws with washers are attached.
Material: Stainless steel (SUS)
Two M4 (length 30 mm 1.181 in) screws with washers are attached.
24
0.945
35
1.378
25
0.984
"22
"0.866
( )
15
0.591
57
2.244
47
1.850
24
0.945
35
1.378
25
0.984
"22
"0.866
( )
15
0.591
57
2.244
47
1.850
15
0.591
27
1.063
39
1.535 28
1.102
47
1.850
57
2.244
25
0.984 15
0.591
30
1.181
40
1.575
45
1.772
47
1.850
57
2.24472
2.835
30.4
1.197 21
0.827
80
3.150
20
0.787
28
1.102
41
1.614
27.2
1.071
57.2
2.252
60
2.362
47
1.850
57
2.244
25
0.984
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

A
B
C
DE
FG
EACH SENSOR TYPE
A: Remaining sheet detection B: Deflecting sheet detection
Ultra-slim photoelectric sensor
EX-13
C: Meandering sheet detection
Wide beam fiber
FT-A8 Digital fiber sensor
FX-305
position B
position A
CX-481 is the amplifier built-in photoelectric sensor
(CX-400 series) for transparent objects sensing. It
monitors the residual amounts of packing film and
announces the periodic replacements of film rolls.
These sensors are retroreflective types so they
can be installed with ease.
EX-10 series amplifier built-in ultra-slim
photoelectric sensor (3.5 mm 0.138 in
thick) that monitors packing film deflection
and can be installed in narrow spaces.
Detects meandering sheets using wide
beam fiber. The fiber amplifier is a 2-output
type that can detect meandering in both
the left and right directions.
Various mark sensing applications and sensor
applications to suit any job are available.
We at SUNX provide every type of sensor for food or drug packaging machines such as the
LX-100 series digital mark sensor made for sensing various types of marks.
Retroreflective type photoelectric sensor
for transparent object sensing
CX-481
13
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

• Aluminum evaporation film • Carrier bags• Transparent film• Paper bags
Tube positioning
DIGITAL MARK SENSOR LX-100 SERIES
D: Air pressure detection
E: Packing and content detection
F: Content detection G: Cut tape verification
Digital laser sensor
LS series
Detects air pressure and displays
it digitally. Its semi-conductor
transducer ensures high
precision and long life. Optimal for
controlling the pressure of
pneumatic machinery.
Adjustable range reflective
photoelectric sensor not effected
by the color of the object. Can be
used for checking packaged
goods or counting contents.
Ideal for sensing objects moving
on a conveyor belt. High precision red laser sensor.
Its minute spot can effectively
detect the presence of narrow cut
tape.
Detects printed marks to align tubes.
Can be used for various kinds of packing film
Digital pressure sensor
DP2 / DP4 series Adjustable range reflective
photoelectric sensor
CX-440 series
Retroreflective photoelectric
sensor
CX-491
14
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.

2431-1 Ushiyama-cho, Kasugai-shi, Aichi,
486-0901, Japan
Phone: +81-(0)568-33-7211
FAX: +81-(0)568-33-2631
SUNX Limited
Phone: +81-(0)568-33-7861
FAX: +81-(0)568-33-8591
Overseas Sales Dept.
http://www.sunx.co.jp/
All information is subject to change without prior notice.
No. CE-LX100-5 June, 2004
●In addition, micro-size inductive proximity sensors and photoelectric sensors with
amplifier-separated available.
Refer to SUNX homepage (http://www.sunx.co.jp/).
Digital Fiber Sensor
FX-300SERIES
Digital Pressure Sensor
DP2 / DP4SERIES
Digital Laser Sensor
LSSERIES
Compact Photoelectric Sensor
CX-400SERIES
Adjustable Range Reflective Photoelectric Sensor
CX-440SERIES
Ultra-slim Photoelectric Sensor
EX-10SERIES
•World standard size.
•Wide variation 116 models.
Introducing SUNX food or drug packaging machine sensors
•
•
Red / Green / Blue / Infrared LED
amplifiers available.
Various fibers available for any
application.
•
•
Bright, easy to view dual-color
digital display (DP4).
Improved functions and wide
variations (DP2).
•
•
3 types of laser sensor heads
available.
General purpose photoelectric sensor
CX-400 series installation compatibility.
•
•
Smallest in the industry with 3.5 mm
0.138 in thickness.
1 m 3.281 ft long-distance sensing
(thru-beam type: EX-19).
mEX-20 made for installation with M3 screws
available.
•
•
Can difference as small as 0.4 mm
0.016 in.
Not affect by color. The difference
in sensing range between black
and white is 1 % or less.
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.
Other manuals for LX-100
1
This manual suits for next models
10
Table of contents
Other Sunx Security Sensor manuals
Popular Security Sensor manuals by other brands

Amprobe
Amprobe TIC 300 PRO user manual

Optex
Optex AX-100TFR Series installation instructions

B.E.G.
B.E.G. LUXOMAT PD4-M-1C-C-SM Installation and operating instruction

Comunello Automation
Comunello Automation DART Installation and user manual

IMS
IMS CX3068 instruction manual

CAME
CAME SMA operating instructions