Superlift SSLG-2 800DC User manual


1
Dear users,
Thank you for choosing this product. Please read this manual carefully before installation and use.
Please do not forget to include this manual if you send the product to a third party.
1. Safety Instruction
Please make sure that the power voltage being used matches with the supply voltage of gate opener
(AC110V or AC220V); kids are not allowed to touch the control devices or the remote-control unit.
The remote-control unit is single button mode or three button mode (please refer to the instructions
of the remote control in accordance with the actual gate opener type). The indicator light on the
remote-control unit will flicker when its button is pressed. Main engine and gate can be unlocked
with a disengagement wrench and the gate can be manually operated after disengagement.
Please make sure that nobody is around the main engine or gate when the switch is operated.
Please temporarily stop using the product if the main engine needs to be repaired or regulated. The
installation and maintenance of the product must be carried out by professionals.
Please read this manual carefully before installing、using、maintaining or repairing it. Without
following this manual, any injury or property losses caused by improper use or unauthorized
modification is out of the responsibility of our company.

2
2. Packing List (standard)
No. Picture Name Quantity
1
Main engine 1
2
Manual release key 2
3
A
B
C
D
A
B
C
D
Remote control 2
4
Magnetic limit switch
accessories box 1
4-1
Magnetic limit switch block 1
4-2
Limit switch block mounting
screw M6X18 4
4-3
Foundation bolt M8 4
4-4
Nut M8 8
4-5
Flat washer Ø8 8
4-6
Spring washer Ø8 4

3
2. Packing List (optional)
No. Picture Name Quantity
1
Steel gear rack 1m/pc
2
Nylon gear rack 1m/pc
3
Infrared sensor 1
4
0
8
5 6
97
4
1 2 3
Wireless keypad 1
5
Alarm lamp 1
6
Mounting plate 1
7
Hexagon head bolt M8×60 4
3. Technical parameters
Model
DKC500DC
DKC800DC
Power supply 220V/50Hz;110V/60Hz 220V/50Hz;110V/60Hz
Motor power 150W 170W
Gate moving speed 11-13m/min 16-18m/min
Maximum weight of gate 500Kg 800Kg
Remote control distance ≥30m ≥30m
Remote control mode Single button mode
/ Three button mode
Single button mode
/ Three button mode
Limit switch Magnetic limit switch Magnetic limit switch

4
Noise ≤58dB ≤58dB
Working duty S2, 20min S2, 20min
Recording of up remote controls 40 40
Frequency 433.92 MHz 433.92 MHz
Working temperature -20°C ~ +70°C -20°C ~ +70°C
Package weight
10Kg
10Kg
4. Installation
DKC500DC/DKC800DC sliding gate opener is applicable to gate weight less than 500kg/800kg, and
length of the sliding gate less than 8m. The drive mode adopts the rack and gear transmission. This
gate opener must be installed inside the enclosure or yard for protection.
4.1 Installation drawing
⑤
④
③
②
0
8
5 6
97
4
1 2 3
⑧
①
⑦
⑥
Figure 1
①Gate opener; ②Wireless keypad (optional); ③Gate; ④Infrared sensor (optional);
⑤Alarm lamp (optional); ⑥Safety stop block; ⑦Gear rack; ⑧Remote control;
4.2 Size of main engine and accessories
4.2.1 Size of main engine

5
213 237
270
Figure 2
4.2.2 Size of mounting plate
107
150
204±0.3
90±0.3
8× 10
Φ
Figure 3
4.3 Installation procedures
4.3.1 Preparation work before installation
Please make sure that the sliding gate is correctly installed, the gate rail is horizontal, and the gate
can be manually moved smoothly before installing the gate opener.
Cable installation
In order to guarantee the normal operation of the gate opener and protect the cables from damages,
please bury the motor & power cable and controlling cable separately with two PVC tubes.
Concrete pedestal
Please cast a concrete pedestal with the size can be 400mm x 250mm, depth be 200mm in advance,
so as to firmly install DKC500DC/DKC800DC gate opener. Please make sure the distance
between the gate and gate opener is appropriate before casting the pedestal.

6
Embedded screws
Concrete
Power line
Mounting plate
Foundation bolt
Figure 4
4.3.2 Main engine installation
a) Dismantle the plastic housing on the main engine before installation and keep relevant fasteners
properly;
b) Please prepare the power line for connecting the mounting plate to the main engine (the number
of power supply cable cores should not be less than 3 PCS, the sectional area of cable core should
be over 1.5mm² and the length should be determined by users according to the situation on
installation spot)
c) Please unlock the main engine before installation, the unlock method is: remove the rubber key
cover, insert the key, and open the manual release bar till it rotates by 90° as shown in Figure 5.
Then turn the output gear and the gear can be rotated easily;
Turn on 90°
Figure 5
4.3.3 Gear rack installation
Fix the mounting screws to the rack.
Put the rack on the output gear, make the rack engage with the output gear then weld the
mounting screw to the gate (each screw with one solder joints firstly).
Manually move the gate (gate should be moved smoothly after motor unlocked) to check
whether there is a fit clearance between rack and output gear, as shown in Figure 7.
Weld all the mounting screws to the gate firmly.

7
Make sure that all racks on the same straight line.
Pull the gate after installed, make sure the entire trip is flexible without any stuck.
Figure 6
The fit clearance of output gear and rack is shown in Figure 7 below:
1-21-2
GearGear rackrack
OutputOutput geargear
mmmm
Figure 7
Warnings
·To ensure safety, install safety stop blocks on both ends of the rails to prevent the gate from running
out of the rail. Before installing the main engine, make sure that the safety stop blocks are in place
and whether it has the function of preventing the gate from running out of the rail or safety range.
·Please make sure that the main engine and its components have good mechanical properties, and
the gate can be operated flexibly when manually moved before installing the main engine.
·Please note that for this product, one control can only drive one main engine, otherwise, the control
system will be damaged.
·Earth leakage circuit breaker must be installed in where the gate movement can be seen, and the
minimum mounting height is 1.5m to avoid being touched by children.
·After installation, please check whether the mechanical property is good or not, whether gate
movement after manual unlocking is flexible or not, whether the installation for infrared sensor
(optional) is correct and effective.

8
4.3.4 Limit switch adjustment
Magnetic limit switch - The installation position of magnetic limit switch is shown in Figure 8:
≤20mm
GateGate
MagnetsMagnets
MagneticMagnetic limitlimit switchswitch stopstop blockblock
GearGear rackrack
OutputOutput geargear
Figure 8

9
The installation of magnetic limit switch stop block is shown in Figure 9:
M6×18M6×18
Right side mounting
Figure 9
Note: The default setting is right side mounting. (According to actual situation to adjust, please
refer to the section 4.3.5 “DIP switch adjustment”, to change the door opening direction through the
DIP switch 5)
Note : After first installed or Re-power up, please drive one opening and closing cycle by pressing
remote control button or external button, then the door width will be remembered by control unit and
the "soft start slow stop" function will be enabled in next working cycle.

1
4.3.5 Control board wiring
VR1VR1 VR2VR2 VR3VR3
U1U1
ONON
OFFOFF
J9J9
LRNLRN
K4K4
UV2UV2
J8J8 RL6RL6
J1J1
J4J4
UV4UV4
C3C3
J2J2
BAT+BAT+
F1F1
D6D6
DKC500DC.PCBDKC500DC.PCB
2015.01.052015.01.05 R8R8 R9R9
N1N1
RL1RL1RL2RL2
D15D15
C20C20
PWRPWR
SW1SW1
U4U4
U3U3
C2C2
J10J10
J7J7
C23C23
+ALM-+ALM- 5 6 7 MOTMOT POWERPOWER
1 2 3 5 7 9
OPOPCOMCOMCLCL4321
M
24VAC24VAC
24VDC24VDC
LearningLearning buttonbutton
OPOP
CLCL
COMCOM
COMCOM
AlarmAlarm lamplamp
StopStop buttonbutton
CloseClose buttonbutton
OpenOpen buttonbutton
COMCOM
24VDC24VDC motormotor
InfraredInfrared sensorsensor
StorageStorage batterybattery
Figure 10
Transformer Power Input Connection
C3C3
J2J2
BAT+BAT+
F1F1
D6D6
DKC500DC.PCBDKC500DC.PCB
2015.01.052015.01.05 R8R8 R9R9
C23C23
POWERPOWER
TransformerTransformer inputinput 220VAC220VAC
TransformerTransformer outputoutput 24VAC24VAC
Figure 11

1
Wiring instruction:
J1 Terminal
5 COM (GND)
6 Photocell input (N.C.);
7 Extra power input +24VDC
J2 Terminal
Connect to 24VAC(Fig.11 shows 120W 230VAC/24VAC annular transformer connection)
BAT+ Terminal
Battery interface
J4 Terminal
DC motor wire connection (Red wire to top, black wire to bottom)
J7 Terminal
1 Gate open control button (N.O.);
2 Gate close control button (N.O.);
3 Stop control button (N.O.);
4 Control button common terminal;
J8 Terminal
24V DC caution light
J10 Terminal
OP Open limit switch;
COM Limit switch common terminal;
CL Close limit switch;
VR1VR1 VR2VR2 VR3VR3
U1U1
ONON
OFFOFF
J9J9
LRNLRN
K4K4
1 2 3 4 5 678
Figure 12
Adjusting knob
VR1: For motor working total time adjustment.

1
Clockwise rotation to increase, counter-clockwise rotation to reduce. The total time can be set to 10
seconds as minimum and 90 seconds as maximum. For example, if gate moves 20 seconds,
please try to add 5 seconds, namely setting 25 seconds is suitable.
VR3: For motor auto-reverse force adjustment when meeting obstacle.
Clockwise rotation to increase the reverse force, counter-clockwise rotation to reduce.
DIP switch adjustment
serial number
1
1 ON 2 OFF: automatic close delay time is 3s.
1 OFF 2 ON: automatic close delay time is 10s.
1 ON 2 ON: automatic close delay time is 30s.
1 OFF 2 OFF: cancel automatic close function.
2
3
ON - Remote control is three button mode, the first button is OPEN, the
second button is CLOSE, the third button is STOP.
OFF- Remote control is single button mode, one same button on the remote
control to circularly control OPEN/STOP/CLOSE/STOP.
4 OFF - External button switch is single button mode, connect to 1 and 4 of J7.
ON - External button switch is three button mode.
5
Left and Right installation setting.
OFF - Right side mounting
ON - Left side mounting
The change of door close direction will be valid only after the re-power.
6
Limit switch setting.
ON - Normal open (N.O.);
OFF - Normal close (N.C.).
7
Meet obstacle reversal function.
ON - enabled;
OFF - disabled.
8
Infrared detection delay when closing
ON - infrared detection delay is 1 second;
OFF - infrared detection delay function is disabled.
Infrared connection
Infrared photocell function: In the closing process, when infrared ray of the photocell is covered by
people or objects during its detection range, the gate will open immediately for security protection.
The distance between photocell receiver and photocell emitter should be more than 2 meters,
otherwise will affect the induction of the photocell.
If connect the infrared sensor, please remove the short connection between 5 and 6 on the J1
terminal.

1
VR1VR1 VR2VR2
K4K4
J8J8 RL6RL6
J1J1
J4J4
+ALM-+ALM- 5 6 7 MOTMOT
V+V-
V+V- NO COM NC
InfraredInfrared receiverreceiver connectingconnecting InfraredInfrared emitteremitter connectingconnecting
Figure 13
Remote control operation
Three button mode remote control: OPEN/CLOSE/STOP of main engine are controlled by three
buttons separately on the remote control.
Single button mode remote control: OPEN/CLOSE/STOP of main engine are controlled by one
button circularly on the remote control.
ThreeThree buttonbutton modemode remoteremote controlcontrol SingleSingle buttonbutton modemode remoteremote controlcontrol
A
B
C
D
OPENOPEN
A
B
C
D
CLOSECLOSE
STOPSTOP
CLOSECLOSE
OPENOPEN
STOPSTOP
PedestrianPedestrian modemode PedestrianPedestrian modemode
Figure 14
Add extra remote control (remote control learning): Remove the main engine housing, then take
out the upper cover of the control box, press and hold the learning button K4 on the control board for
2 seconds, the indicator light LRN will be on; press the button that to be learned on the remote
control twice, the LRN will flash several times and be off; remote control learning complete. A
maximum of 40 remote controls can be learned.
Delete remote control: To delete remote control that have been learned; press and hold the

1
learning button K4, the indicator light LRN will be on; then release it until LRN is off. After the steps,
all the matched remote controls will be deleted.
The fourth button on the remote control is for pedestrian mode, press the button while the door is
closed, it will open for 1 meter which is for pedestrian only.
Battery connection
+
-
+
C3C3
J2J2
BAT+BAT+
F1F1
D6D6
DKC500DC.PCBDKC500DC.PCB
2015.01.052015.01.05 R8R8 R9R9
C23C23
POWERPOWER
+
ChargerCharger
-
StorageStorage batterybattery
ControlControl boardboard
Figure 15

1
Solar panel connection
CHARGECHARGE LOADLOAD BATTERYBATTERY
+ - + - + -
+
-
+
-
C3C3
J2J2
BAT+BAT+
F1F1
D6D6
DKC500DC.PCBDKC500DC.PCB
2015.01.052015.01.05 R8R8 R9R9
C23C23
POWERPOWER
SolarSolar panelpanel SolarSolar chargercharger
StorageStorage batterybattery
ControlControl boardboard
Figure 16
5. Others
5.1 Maintenance
Check whether the gate operates normally every month.
For the sake of safety, each gate is suggested to be equipped with infrared protector, and regular
inspection is required.
Before installation and operation of the gate opener, please read all instructions carefully.
Our company reserves the right to change the instruction without prior notice.
5.2 Troubleshooting
Problems Possible Reasons Solutions
The gate cannot open or
close normally, and LED
does not light.
1.The power is off.
2.Fuse is burned.
3.Control board power wiring with
problem.
1.Switch on the power supply.
2.Check the fuse (code F1) and
transformer input interface fuse,
change the fuse if burnt.

1
3.Re wiring according to
instructions.
The gate can open but
cannot close.
1.Photocell wiring with problem.
2.Photocell mounting with problem.
3.Photocell is blocked by objects.
4.Auto-reverse force is too small.
1.If not connect photocell, please
make sure that the infrared port
and GND short circuit; if connect
infrared sensor, please make sure
the wiring is correct and the
photocell is N.C.
2.Make sure that the photocell
mounting position can be mutually
aligned.
3.Remove the obstacle.
4.Increase auto-reverse force.
Remote control doesn’t
work.
1.Battery level of the remote
control is low
2.Remote control learning is not
completed
1.Change the remote control
battery
2.Re-conduct remote control
learning
Press OPEN, CLOSE
button, the gate is not
moving, motor has
noise.
1.Capacitor is broken.
2.Capacitor is poor connected.
3.Gate moving is not smoothly.
1.Change capacitor.
2.Check the capacitor wiring.
3.According to the actual situation
to adjust the motor or the gate.
Not stop at the limit
position when opening /
closing.
1. The limit direction is wrong.
2. The mounting of magnetic limit
switch with problem.
1.Check whether the limit switch
wiring is consistent with the actual
direction of operation.
2. Check whether the distance
between magnetic limit switch and
motor, and the height of the
magnetic limit switch can meet the
mounting requirement.
Leakage switch tripped. Power supply line short circuit or
motor line short circuit. Check wiring.
Remote control working
distance is too short. Signal is blocked.
Connect external receiver
antenna, 1.5 meters above
ground.
The gate moves to the
middle position to stop
or reverse.
1.Motor output force is not enough.
2.Auto-reverse force is not enough.
3.Gate meets obstacle.
1.Adjust the VR2.
2.Adjust the VR3.
3.Remove the obstacle.
Gate opens
automatically
Automatic close function has been
turned on but with incorrect
opening direction.
Please refer to the attentions
under 4.3.5 “DIP switch
adjustment”, to change the
opening direction through DIP
switch 5.

1
Warranty
Warranty Ordinance
1. To repair against this warranty card and invoice during the warranty period.
2. Warranty period: 1 year after the date of invoice.
3. Without unauthorized dismantling, any product broken or damage due to quality problem, we’ll
offer the repair service for free or replace for free.
4. The malfunction and damaged caused by incorrect use or man fault is not covered by this
warranty.
Maintenance Record
Check Date Check Content Maintained by
2018V1
Table of contents