SUPMEA SUP-PH8.0 User manual

User's Manual
U-PH8-MYEN2
pH/ ORP Controller
Supmea Automation Co.,Ltd.
www.supmea.com
Headquarters
5th floor,Building 4,Singapore Hangzhou Science Technology Park,No. 6 street,
Hangzhou Economic Development Area,Hangzhou 310018,China
Singapore
2 Venture Drive #11-30 Vision Exchange Singapore
Philippines
Majestic Subdivision, Lot 1, 1800 Rainbow St, Marikina, 1811 Metro Manila, Philippines

I
Preface
Thank you for purchasing pH/ORP online analyzer. Please read this manual
carefully before operating and using it correctly to avoid unnecessary losses
caused by false operation.
Note
Modification of this manual’s contents will not be notified as a result of some
factors, such as function upgrading.
We try our best to guarantee that the manual content is accurate, if you find
something wrong or incorrect, please contact us.
This product is forbidden to use in explosion-proof occasions.
Version
U-PH8-MYEN2

II
Safety Precautions
In order to use this product safely, be sure to follow the safety precautions
described.
About this manual
Please submit this manual to the operator for reading.
Please read the operation manual carefully before applying the instrument.
On the precondition of full understanding.
This manual only describes the functions of the product. The company does
not guarantee that the product will be suitable for a particular use by the
user.
Precautions for protection, safety and modification of this product
To ensure safe use of this product and the systems it controls, Please read
carefully the operation manual and understand the correct application
methods before putting into operation, to avoid unnecessary losses due to
operation mistakes. If the instrument is operated in other ways not
described in the manual, the protections that the instrument give may be
destroyed, and the failures and accidents incurred due to violation of
precautions shall not be borne by our company.
When installing lightning protection devices for this product and its control
system, or designing and installing separate safety protection circuits for
this product and its control system, it needs to be implemented by other
devices.
If you need to replace parts of the product, please use the model
specifications specified by the company.
This product is not intended for use in systems that are directly related to
personal safety.Such as nuclear power equipment, equipment using
radioactivity, railway systems, aviation equipment, marine equipment,
aviation equipment and medical equipment.If applied, it is the responsibility
of the user to use additional equipment or systems to ensure personal
safety.
Do not modify this product.

III
The following safety signs are used in this manual:
Hazard, if not taken with appropriate precautions, will result in serious
personal injury, product damage or major property damage.
Warning:Pay special attention to the important information linked to product
or particular part in the operation manual.
Confirm if the supply voltage is in consistent with the rated voltage
before operation.
Do not use the instrument in a flammable and combustible or steam
area.
To prevent from electric shock, operation mistake, a good grounding
protection must be made.
Thunder prevention engineering facilities must be well managed: the
shared grounding network shall be grounded at is-electric level,
shielded, wires shall be located rationally, SPD surge protector shall be
applied properly.
Some inner parts may carry high voltage. Do not open the square panel
in the front except our company personnel or maintenance personnel
acknowledged by our company, to avoid electric shock.
Cut off electric powers before making any checks, to avoid electric
shock.
Check the condition of the terminal screws regularly. If it is loose, please
tighten it before use.
It is not allowed to disassemble, process, modify or repair the product
without authorization, otherwise it may cause abnormal operation,
electric shock or fire accident.
Wipe the product with a dry cotton cloth. Do not use alcohol, benzine or
other organic solvents. Prevent all kinds of liquid from splashing on the

IV
product. If the product falls into the water, please cut off the power
immediately, otherwise there will be leakage, electric shock or even a
fire accident.
Please check the grounding protection status regularly. Do not operate if
you think that the protection measures such as grounding protection and
fuses are not perfect.
Ventilation holes on the product housing must be kept clear to avoid
malfunctions due to high temperatures, abnormal operation, shortened
life and fire.
Please strictly follow the instructions in this manual, otherwise the
product's protective device may be damaged.
Do not use the instrument if it is found damaged or deformed at opening
of package.
Prevent dust, wire end, iron fines or other objects from entering the
instrument during installation, otherwise, it will cause abnormal
movement or failure.
During operation, to modify configuration, signal output, startup, stop,
operation safety shall be fully considered. Operation mistakes may lead
to failure and even destruction of the instrument and controlled
equipment.
Each part of the instrument has a certain lifetime, which must be
maintained and repaired on a regular basis for long-time use.
The product shall be scrapped as industrial wastes, to prevent
environment pollution.
When not using this product, be sure to turn off the power switch.
If you find smoke from the product, smell odor, abnormal noise, etc.,
please turn off the power switch immediately and contact the company in
time.

V
Disclaimer
The company does not make any guarantees for the terms outside the
scope of this product warranty.
This company is not responsible for damage to the instrument or loss of
parts or unpredictable damage caused directly or indirectly by improper
operation of the user.
Package contents
After opening the box, please confirm the package contents before starting the
operation.If you find that the model and quantity are incorrect or there is physical
damage in appearance, please contact us.
Number
Name
Quantity
Remarks
1
pH/ORP online
analyzer
1
2
Manual
1
3
Certificate
1

VI
Contents
Chapter 1 Introduction........................................................................................................1
Chapter 2 Installation..........................................................................................................3
2.1 Instrument installation............................................................................................3
2.2 Electrode installation..............................................................................................5
2.3 Product wiring......................................................................................................... 6
Chapter 3 Display Panel.................................................................................................... 8
3.1 Display Panel.......................................................................................................... 8
3.2 Navigation keys.......................................................................................................8
3.3 LED Indicator...........................................................................................................9
3.4 Default setting......................................................................................................... 9
Chapter 4 System menu.................................................................................................. 10
4.1 Mode.......................................................................................................................10
4.2 Calibration............................................................................................................. 10
4.3 Temperature.......................................................................................................... 13
4.4 Relay A...................................................................................................................13
4.5 Relay B...................................................................................................................13
4.6 Automatic Cleaning.............................................................................................. 14
4.7 Communication.....................................................................................................14
4.8 Current output A................................................................................................... 14
4.9 Current output B................................................................................................... 14
4.10 Clock.................................................................................................................... 15
4.11 Filter......................................................................................................................15
4.12 Backlight.............................................................................................................. 15
4.13 Password.............................................................................................................15
4.14 language..............................................................................................................15
4.15 Recording............................................................................................................ 16
4.16 Factory setting.................................................................................................... 16
Chapter 5 Communication...............................................................................................17
5.1 Communication connection................................................................................ 17
5.2 Modbus communication protocol....................................................................... 18
Chapter 6 Maintenance....................................................................................................23
Chapter 7 Troubleshooting.............................................................................................. 25

Chapter 1 Introduction
www.supmea.com
- 1 -
Chapter 1 Introduction
pH/ORP controller is one of the intelligent on-line chemical analyzers, which is
widely used in the continuous monitoring on pH value or OPR value and
temperature of thermal power, chemical engineering and fertilizer, metallurgy,
environment protection, pharmacy, biochemistry, food and tap water as well as
other solution.
Technical Parameters
Screen size
4.3 inch
Installation
Panel mounted
Dimension
Overall dimension:144mm * 144mm * 115mm
Cutout dimension:138mm * 138mm
Panel thickness
1.0 ~ 5.0mm
Weight
0.68Kg
Ingress protection
IP65
Measured variables
pH/ORP/Temp
Measurement
range
pH
-2.00 ~ 16.00pH
ORP
-1999 ~ 1999mV
Temp
-10.0 ~ 130.0℃
Accuracy
pH
pH sensor
±0.02pH
Antimony pH
sensor
±0.2pH
ORP
±0.1%FS
Temp
NTC10K
-10 ~ 60℃
±0.3℃
60 ~ 130℃
±2.0℃
PT1000/PT100
±0.3℃
Temperature
compensation
NTC10K/PT1000(PT100 optional)
Temperature compensation:manual/automatic
Operating temperature
0 ~ 60℃

Chapter 1 Introduction
www.supmea.com
- 2 -
Storage conditions
-20 ~ 70℃
Relative humidity
(10 ~ 85)%RH(No condensation)
Input resistance
≥ 10^12Ω
Language
Chinese/English
Analog output
1 output(2 output optional)4-20 mA, maximum loop
is 750Ω,±0.2%FS
Communication protocol
MODBUS-RTU RS485
Alarm relay
2 channel, Normally open
245VAC 5A Max.
Automatic Cleaning
Manually clean, set cleaning interval
Record
100 sets, recording interval can be set through
configuration, the recording method is FIFO.
Power supply
100 ~ 240VAC,5W Max,50/60Hz

Chapter 2 Installation
www.supmea.com
- 3 -
Chapter 2 Installation
2.1 Instrument installation
The installation site and method of the instrument are explained, the part shall be
carefully read during the installation.
Notes for installation
The instrument is panel mounted.
Please install it at the place with good ventilation in order to prevent the
internal temperature of the instrument from rising.
Horizontal installation shall be realized as possible
The following places shall be avoided during the installation
Do not expose direct to sunlight and near heaters.
The location where the environment temperature exceeds 60℃during the
work.
The location where the environment humidity exceeds 85% during the
work.
The vicinity of the electromagnetic occurring sources.
The sites with strong mechanical vibration.
The site where the temperature is changed a lot and the moisture
condensation is easily formed.
Places with lots of lampblack, steam, moisture, dust and corrosive gas.
Installation
A 138mm*138mm installation hole is opened at the instrument cabinet or
installation panel (The thickness of the mounting panel is 1.0 ~ 5.0mm).
Insert the controller into the square mounting hole and fasten the holder.

Chapter 2 Installation
www.supmea.com
- 4 -
2.2 Electrode installation
Fix ed
Panel Mounted
Cut-out Size
Installation Panel Dimension
90mm
138mm
138mm
200mm
200mm

Chapter 2 Installation
www.supmea.com
- 5 -
Figure 1 Sketch diagram of the common installation method
①Side wall installation
②Flange mounted at the top
③Pipe installation
④Top installation
⑤Submersible installation
⑥Flow-through installation
The interface must be in 15 oblique angle, or it will affect the normal test
and use of the electrode. We won’t be responsible for any results
due to this.

Chapter 2 Installation
www.supmea.com
- 6 -
2.3 Product wiring
Wiring diagram
Definition of the port
1、INPUT:pH/ORP/ Antimony electrode measuring terminal
2、NC:undefined
3、REF:pH/ORP/ Antimony electrode reference
4、NC:undefined
5、TEMPA:Temperature measurement terminal A
6、TEMPB:Temperature measurement terminal B
7、TEMPC:Temperature measurement terminal C
8、RS485 A+:RS485 communication interface A﹢
9、RS485 B-:RS485 communication interface B﹣
10、0/4 ~ 20mA A+:A Current output+
11、0/4 ~ 20mA A/B-:A/B Current output -
12、0/4 ~ 20mA B+:B Current output+
13/14、WASH:Cleaning device relay
15/16、REL B:Alarm relay B
17/18、REL A:Alarm relay A
19、POWER N:AC220V neutral wire
20、POWER L:AC220V live wire
NC
REF
TEMP A
TEMP B
TEMP C
NC
INPUT
POWER REL ARS485
WASH 0/4~20mA
REL B
+
+
-
A+
B-
B A
~
LN
POWER:100~240VAC 50/60Hz
Relay(REL A/REL B/WASH):245VAC Max. 5A
0/4~20mA:Isolated Max. load 750Ω
NTC
PTC
21
3456789
10
111213141516171819
20

Chapter 2 Installation
www.supmea.com
- 7 -
Electrical wiring reference diagram

Chapter 3 Display Panel
www.supmea.com
- 8 -
Chapter 3 Display Panel
3.1 Display Panel
!7.00 pH
2018/08/08 12:00:00
MTC
25.0℃
B:8.00mA
A:12.00mA
RELAY A RELAY BWASH
MENU ESC ENT
A/B Current Output
Date Time/
Main Value Unit
Temperature
Compensation
Temperature Value
Alarm
3.2 Navigation keys
Sign
Button name
Function description
ME NU
MENU
Under “Monitoring page” - Enter the MENU
Under “Menu page” - Exit the MENU
ESC
EXIT
Under "Monitoring page" - Alarm view
Under "Menu page" - Return to the previous page
Under "Calibration page" - Skip this item
UP
Under “menu page” - Select the related menu
Modify the values in the configuration state
RIGHT
Make a recurrent selection of digit of parameters
modify the original indication value
ENT
ENTER
Under “Menu page” - Enter the sub-menu or
confirm

Chapter 3 Display Panel
www.supmea.com
- 9 -
3.3 LED Indicator
WASH: Cleaning control relay status indicator
RELAY A: Alarm control relay A status indicator
RELAY B: Alarm control relay B status indicator
3.4 Default setting
Password:0000
Mode:pH
Calibration type: 3-point calibration, 4.00 / 6.86 / 9.18
Temperature type: MTC 25.0 ℃
Relay A: ON, Hi, high point 11.00pH, return difference 1.00pH
Relay B: ON, Lo, low point 3.00pH, return difference 1.00pH
Cleaning relay: OFF
Communication: baud rate 9600, no parity, 1 stop bit, floating point format 4321,
address 1
Current output A: pH, 4 ~ 20mA, -2.00 ~ 16.00pH
Current output B: T, 4 ~ 20mA, -10.0 ~ 130.0 ℃
Date and time: 0: 0: 0: 0 on January 1, 2018
Filter coefficient: 0
Backlight brightness: 20
Recording interval: 15 minutes

Chapter 4 System menu
www.supmea.com
- 10 -
Chapter 4 System menu
4.1 Mode
pH mode
Through mode option, pH mode can be selected. The main display numbers and
units of the measurement display interface will be switched to pH value and its
unit pH, and other parameters in the configuration settings will also be switched to
parameters in pH mode.
ORP mode
Through mode option, ORP mode can be selected. The main display number and
unit of the measurement display interface will be switched to the ORP value and
its unit mV, and other parameters in the configuration settings will also be
switched to the parameters in ORP mode.
Antimony mode
Through mode option, antimony mode can be selected, which only support the
measurement of antimony electrode. The main display numbers and units of the
measurement display interface will be switched to the antimony electrode
measurement value and its unit pH. Other parameters in the configuration settings
will also be switched to the parameter in antimony mode.
4.2 Calibration
pH calibration
When it is pH mode, the pH calibration function can be used. The calibration
points can be selected from 1 to 3 points. The specific calibration steps are as
follows:
pH 1-point calibration: Select 1 point for calibration point, press [ENT] to
enter the pH 1-point calibration interface, change the standard value on
the interface to the theoretical value of the current pH standard buffer

Chapter 4 System menu
www.supmea.com
- 11 -
solution, and then put the pH electrode into the pH standard buffer solution.
After the actual measurement value is stable, press [ENT] to confirm the
calibration and return to the menu interface.
pH 2-point calibration: Select 2 points for calibration point and press [ENT]
to enter the calibration point selection interface. You can choose from 6
types of calibration point combinations: 4.00 / 6.86, 6.86 / 9.18, 4.00 / 9.18,
4.01 / 7.00, 7.00 / 10.01, 4.01 / 10.01. Press [ENT] to confirm the selected
calibration point and enter the first point interface of pH 2-point calibration.
Put the pH electrode into the first pH standard buffer solution. After the
actual measurement value is stable, press [ENT] to confirm the calibration
and enter the second point interface of pH 2-point calibration. Put the pH
electrode into the second pH standard buffer solution. After the actual
measurement value is stable, press [ENT] to confirm the calibration and
return to the menu interface.
pH 3-point calibration: Select 3 points for calibration point and press [ENT]
to enter the calibration point selection interface. You can choose from two
types of calibration point combinations: 4.00 / 6.86 / 9.18, 4.01 / 7.00 /
10.01. Press [ENT] to confirm the selected calibration point and enter the
first point interface of pH 3-point calibration. Put the pH electrode into the
first pH standard buffer solution. After the actual measurement value is
stable, press the [ENT] to confirm the calibration and enter the second
point interface of pH 3-point calibration. Put the pH electrode into the
second pH standard buffer solution. After the actual measurement value is
stable, press the [ENT] to confirm the calibration and enter the third point
interface of pH 3-point calibration. After the actual measurement value is
stable, press [ENT] to confirm the calibration and return to the menu
interface.

Chapter 4 System menu
www.supmea.com
- 12 -
ORP calibration
When it is ORP mode, the ORP calibration function can be used. The calibration
points can be selected from 1 to 2 points. The specific calibration steps are as
follows:
ORP 1-point calibration: Select 1 point for calibration point, press [ENT] to
enter the ORP 1-point calibration interface, change the standard value on
the interface to the theoretical value of the current ORP standard buffer
solution, and then put the ORP electrode into the ORP standard buffer
solution. After the actual measurement value is stable, press [ENT] to
confirm the calibration and return to the menu interface.
ORP 2 point calibration: Select 2 points for calibration point, press [ENT]
to enter the first point interface of the ORP 2 point calibration, change the
standard value on the interface to the current theoretical value of the first
ORP standard buffer solution, and then put the ORP electrode into the first
ORP standard buffer solution. After the actual measurement value is stable,
press [ENT] to confirm the calibration and enter the second point interface
of ORP 2-point calibration. Change the standard value on the interface to
the current theoretical value of the second ORP standard buffer solution,
and then put the ORP electrode into the second ORP standard buffer
solution. After the actual measurement value is stable, press the [ENT] key
to confirm the calibration and return to the menu interface.
Antimony calibration
When it is antimony mode, antimony calibration function can be used. The
calibration point can be selected from 1 to 3 points. The specific calibration steps
are the same as those of pH calibration. An antimony electrode is required for
measurement.

Chapter 4 System menu
www.supmea.com
- 13 -
4.3 Temperature
MTC mode
Through temperature option, MTC mode can be selected. Under this mode,
temperature value of the solution to be measured can be manually set.
NTC mode
Through temperature option, NTC mode can be selected. Under this mode,
temperature value of the test solution measured by the temperature probe for the
NTC 10K electrode can automatically be read, and current measured temperature
can be calibrated. The temperature calibration range is -10.0 ~ 10.0 ℃.
PTC mode
Through temperature option, PTC mode can be selected. Under this mode,
temperature value of the test solution measured by the temperature probe for the
PT1000 electrode (customizable) can automatically be read, and current
measured temperature can be calibrated. The temperature calibration range is
-10.0 ~ 10.0 ℃.
4.4 Relay A
Entering the relay A option, the user can choose to turn this function on or off. If
choosing to turn it on, the user can choose the high point (Hi) or low point (Lo)
alarm, and then enter the set point and return difference value, press [ENT] to
complete the setting and return to the menu interface.
4.5 Relay B
Entering the relay B option, the user can choose to turn this function on or off. If
choosing to turn it on, the user can choose the high point (Hi) or low point (Lo)
alarm, and then enter the set point and return difference value, press [ENT] to
complete the setting and return to the menu interface.
Table of contents
Other SUPMEA Controllers manuals
Popular Controllers manuals by other brands

WAGO
WAGO 8003 Series Operating and assembly instructions

Delta Electronics
Delta Electronics AC Motor Drive VFD-EL user manual

Mitsubishi Electric
Mitsubishi Electric Q172DCPU user manual

Popp
Popp POPE009204 manual

Sonnet
Sonnet Tempo edge SATA Pro 6Gb ExpressCard/34 user guide

Smartgen
Smartgen MGC120 user manual

HomeMatic
HomeMatic HM-LC-Sw4-SM-2 Installation and operating manual

Ecus
Ecus POWER_AVR SVR TRI 3/3 user manual

Murphy
Murphy PowerCore MGC1000 Operation manual

AMX
AMX Control Card RDC-PDC Installation sheet

Sturtevant Richmont
Sturtevant Richmont TCV operating instructions

DT Research
DT Research DT1363 Basic operation guide