  9. Suttle FutureLink 649NV-48 User manual

Suttle FutureLink 649NV-48 User manual

Suttle
Part Number
Product Information
Description
649NV-48 1-line VDSL2 NID splitter, RJ14 test jack (pair 1 = network, pair 2 = premise), 3 x single-pair tool-less toggles
for voice, 1 x single-pair tool-less toggle for data (purple)
649NV-CONVKT Conversion ground bar and adapter cradle used to install 649NV-48 & protection module in Siecor NI-2006-
13L11CT, NI-2006-13L
649-ADP Adapter cradle and auxilliary clip used in Siecor NI-2006-13L11CT, NI-2006-13L to install 649-NV-48
649NV-48
649-ADP
649NV-CONVKT
The FutureLinkTM VDSL NID splitter is designed to provide POTS
separately from VDSL signals at the point of entry to a subscriber.
The Ring Trip Mitigation feature allows uninterrupted IPTV
services during phone calls. Its unique tool-less technology is
designed to fit inside most NIDs.
A toggle design allows three pair tool-less voice distribution
and one pair tool-less data distribution. Clear toggles allow the
installer to clearly see that the connection has been established.
The splitter supports all ADSL and VDSL2 technologies up to 30
MHz (30a Profile).
DC Loop Current: 0 – 100mA
DC Loop Voltage: 0 to -60V
DC Resistance: ≤ 25 Ω
Insertion Loss: < 0.5dB
Attenuation Distortion: < 1.0dB
Delay Distortion: < 200us
ADSL Band Attenuation: > 65dB @ 30kHz – 300kHz
> 55dB @ 300kHz – 30MHz
Return Loss:
6dB ERL, 5dB SRL-Low, 3dB SRL-High
Longitudinal Balance: > 57dB
Lead Wire Length: 12 inches
■ Tool-less capability with easy viewing for proper connections
■Front facing IDC wire entry holes for ease of insertion
■Accepts 22-26 AWG wire
■Minimal termination force required for each wire pair
■Audible click toggle upon installation
■ Convenient mounting for most NID styles
■ Ring Trip Mitigation for superior IPTV delivery
■
Cradle detaches and allows placement on premise walls separate from NID
■ Compatible for ADSL to VDSL2 technologies up to 30MHz (30a profile)
Compatible with a variety of NIDs including:
Corning: 7600 Series, 9600 Series, UNI-3056-11U2,
UNI-30EQ3-13U1, UNI-30K3, UNI-30K6,
NI-2006-13L11CT, UNI-30C3-13U1, UNI-30C6-13U1
Tyco-Keptel: SNI4600
AFL: SNI-760
Siecor: NI-2006-13L11CT, NI-2006-13L
FutureLinkTM Tool-less VDSL NID Splitter
Specifications
Description
Features
TR-127 (Ring Trip Mitigation): Approved
GR-3167: Compliant
FCC: Approved
Testing
649NV-48
649-ADP
1001 East Highway 212 • Hector, MN USA 55342 • suttlesolutions.com
Toll Free: 1 (800) 852-8662 • Local: (320) 848-6711 • Fax: (320) 848-6218
Specifications subject to change without notice. Copyright 2014. 1120514
FutureLinkTM Tool-less VDSL NID Splitter
The cradle comes attached to the splitter in shipping.
First, make sure the network leads out of the splitter are facing the
TELCO side of the NID.
Second, tilt the attached splitter and cradle down towards the right
side of the NID slot and rock the left side down into position.
The cradle comes attached to the splitter in shipping.
First, detach the cradle from the splitter by pulling back on the
cradle arm from the splitter.
Second, tilt the splitter down to the right so that the tab beneath
the splitter slides under the knob fixed on the NID.
Lastly, push the left side of the splitter down while snapping the
NID arm tab into a latching position with the splitter.
■ Remove cradle from module.
■ The cradle may be attached to a premise backboard with two
flathead screws. Attach the cradle close to the 66 block so that
the 12” tail from the module can reach.
■ Snap the module into the cradle and attach the network leads
to the connector block for the Telco feed.
■ Data and voice jumpers can be run from the module to the
proper distribution connections.
To view a demonstration video, visit the Suttle website
(www.suttleonline.com) and select the video area under the
support tab.
If you need additional training please call Customer Service at
1-800-852-8662.
Premise Application
Mounting Instructions (with cradle)
Mounting Instructions (without cradle)
■ Install 649NV module, terminate all network and premise
connections.
■ Use a test set with a 6 position, 4 conductor RJ plug.
■ Open cover, disconnecting network input, and insert test set
into the “TEST” jack.
■ Test the line for shorts or opens using L1 (center pair of RJ
contacts).
■ Test the bridged POTS drops (up to 3 premise connections)
for shorts using L2 (outer pair of RJ contacts).
■ To test for open circuits in the bridged POTS drops; close
the 649NV module cover completely, plug test set into user
interface jacks in the premise.
■ To test for shorts or opens on the data port; close the 649NV
module cover completely, plug test set into use interface jack
in the premise.
Testing Procedure
Application Diagrams

This manual suits for next models

2

Other Suttle Cables And Connectors manuals

Suttle SAM-VDSL User manual

Suttle

Suttle SAM-VDSL User manual

Suttle 900 Series User manual

Suttle

Suttle 900 Series User manual

Popular Cables And Connectors manuals by other brands

Atlona AT-HDMI-210 Specifications

Atlona

Atlona AT-HDMI-210 Specifications

SECO-LARM Enforcer SD-7103GC-PEQ installation manual

SECO-LARM

SECO-LARM Enforcer SD-7103GC-PEQ installation manual

Philips SWA2102NB Specifications

Philips

Philips SWA2102NB Specifications

EMP-Centauri C2/1PNP(T+S)-W1 manual

EMP-Centauri

EMP-Centauri C2/1PNP(T+S)-W1 manual

Surpass QCH-F Operation manual

Surpass

Surpass QCH-F Operation manual

Weidmüller ACT20X user manual

Weidmüller

Weidmüller ACT20X user manual

Danfoss DEVIpipeheat 10 V3 installation guide

Danfoss

Danfoss DEVIpipeheat 10 V3 installation guide

HEIDENHAIN HMC 6 operating instructions

HEIDENHAIN

HEIDENHAIN HMC 6 operating instructions

CommScope AMP NETCONNECT MRJ21 1479452-1 instruction sheet

CommScope

CommScope AMP NETCONNECT MRJ21 1479452-1 instruction sheet

Masimo RD SET SL Series Directions for use

Masimo

Masimo RD SET SL Series Directions for use

Dametric K-DDRS1 user manual

Dametric

Dametric K-DDRS1 user manual

Lapp Group ÖLFLEX SOLAR AL FLEX installation guide

Lapp Group

Lapp Group ÖLFLEX SOLAR AL FLEX installation guide

Lindy 43098 user manual

Lindy

Lindy 43098 user manual

Redarc KIT24 quick start guide

Redarc

Redarc KIT24 quick start guide

ENFORCER MVE-PN11-01Q manual

ENFORCER

ENFORCER MVE-PN11-01Q manual

Philips IntelliVue MX40 Instructions for use

Philips

Philips IntelliVue MX40 Instructions for use

Erbe 20196-129 Notes on Use

Erbe

Erbe 20196-129 Notes on Use

Renesas H8S/2218 Series user manual

Renesas

Renesas H8S/2218 Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.