ENT
RST
TBC-961 USER MANUAL PROGRAMMABLE COUNTER
Specifications:
Displays:
FRONT KEYS:
ADJUSTMENT OF STATION:
ADJUSTMENT OF ROTARY:
PROCEDURE:
FUNCTION DISPLAY
STATION
ROTARY 1 or 2
0 to 99
Stn
Stn
Rotr
Rotr
RANGE
(A) Display 1: Upper 8 - Digit Display in RED colour indicates TOTAL COUNT.
Lower 4 - Digit Display in GREEN colour indicates RPM. (9999) & Tablet Rate.(B) Display 1:
1. Micro Controlellr Based, Double Display.
2. Dimentions: Size: 96 X 96 X 65 mm.
Panel cutout: 92 X 92 mm.
3. Supply: 230V AC+10 %, 50 Hz.
4. Sensor: NPN/PNP Proximity Switch Selectable.
5. Indicate total count RATE and RPM
1.Press key for 2 seconds for changes value of Station.
Display -1 will indicate the current value of STATION.
Display-2 will show
You can changes current value of set point by press
1.Press key for 4 seconds for changes value of Station.
Display -1 will indicate the current value of STATION.
Display-2 will show
You can changes current value of set point by press & keys.
-
These Front keys are used for see and changes current values of SET COUNT, STATION and
ROTARY. When up key press display will show count per minute.
ENT
RST
SET
SET
SET
The 8 Digit shows the total count of tablet
. (1) SHIFT Digit key and (2) UP key
. By using SHIFT Digit key4, you can select the digit to be changed.
. A blinking dot indicates the selected digit.
. By using UP key, you can increase the value of selected digit.
. Shift the dot to a digit you want to change, by key.
. Increase the value of selected digit by key.
. This way you can change the station NO. & No. OF Rotary.
. Press to store set value in memory, simultaneously counter goes in control mode.
TBC-961
SET ENT
RES ET
TOTAL COUNT
RPM
99999999
9999