4
5.1 MAINTENANCE GUIDE
Disassembly instructions:
1. Place the sprayer upright on a flat surface.
2. Remove the pins and washers from the upper end of the pump tube. Remove the pump lever from the pumping tube, taking care not to
lose the washers and pins.
3. Loosen the guide nut on the top of the tank. Remove the pump tube.
4. To check the ball valve and the piston ring, remove the valve holder nut and make sure that the ball valve is clean and in good condition as
well as the piston ring, if not replace them.
5. Once replaced, reassemble following the steps in reverse.
A unit that has been used with herbicides should never be used to spray insecticides, unless the sprayer has been properly cleaned and all
other chemicals neutralized. Failure to do this could cause you to kill plants that have been sprayed.
Always follow manufacturer’s instructions of the chemicals in use to avoid accidents and take maximum advantage of the product.
Store your sprayer clean, empty and dry in a place protected from sunlight.
To keep your sprayer in good conditions of use is necessary to maintain oiled the following parts:
gun o-rings, piston ring, gasket, breather valve and cap gasket.
NOTE:
Below are instructions for maintaining your spray:
Rinse with clean water externally and internally, to avoid risk of contamination. To keep your sprayer in good condition it is recommended to change the
following parts when servicing your sprayer:
- Checks for O-rings - Piston Ring - O-rings for nozzle - Breather valve -Gasket for nozzle
TROUBLE SHOOTING GUIDE
6.
PROBLEM
The tank collapses when pressuring it.
CAUSE SOLUTION
The breather check needs lubrication. Lubricate or replace it if it is damaged.
The piston sleeve does not run smoothly
and it is hard to pump.
The agrichemical used has made the
piston sleeve to swell up.
Replace the piston sleeve, lubricate it first.
The piston sleeve runs too smoothly and
it does not keep pressure.
The piston sleeve is worn out or shrunk. Replace the piston sleeve, lubricate it first.
Although the sprayer is being pumped
vigorously it does not build pressure.
The plasticball is stuck or dirt is preventing
the ball to sit properly on the ball-holder nut.
Clean the ball holder nut, and the ball,
replace them if necessary.
When pumping a creak is produced between
the pump tube and pump holder nut.
The pump tube and pump holder nut
need lubrication.
Lubricate both of them.
The shut-off valve does not close after
releasing the trigger.
The plunger O-rings are worn out or
swollen.
Replace them and lubricate the plunger
with the new O-rings.
The shut-off valve does not function
when depressing the trigger.
The filter or nozzle are blocked. Take the filter out of the shut-off valve,
clean or replace it and clean the nozzle.
ATENCIÓN OIL PUMP TUBE AND PISTON SLEEVE BEFORE
ASSEMBLING IN THE SPRAYER.
1
4
23