Symondo Controller WLAN User guide

Installation and operating instruction
Symondo Controller WLAN
Read carefully before installation, commissioning and operation

CONTENT
Safety Instructions 3
EG-Conformity 3
General Instructions 3
Changes to the Unit 3
Warranty and Liability 4
Disposal and Pollutants 4
Description Symondo Controller WLAN 5
Technical Data 5
Scope of Supply 5
Installation 6
Symondo Controller WLAN installation 6
Example Controller-Connection 8
Example CAN-Connection 8
Operation 9
Room Overview 9
Operating Mode 10
Menu 10
Set Operation Hours 11
Set Operation Hours 12
Expert Menu 13
Settings 13
Devices 14
Rooms 15
Sensors 16
Functions 17
WiFi 21
Access Point 22
WiFi Sensor 22
Service Values 23
Symondo Controller WLAN and Symondo App Configuration 23
Support 24
Notes 24
2

SAFETY INSTRUCTIONS
EG-Conformity
By affixing the CE mark to the unit the manufacturer declares that Symondo Controller WLAN conforms to the following relevant safety
regulations:
lEU low voltage directive 2014/35/EU
lEU electromagnetic compatibility directive 2014/30/EU
conforms. Conformity has been verified and the corresponding documentation and the EU declaration of conformity are kept on file by
the manufacturer.
General Instructions
Please read carefully!
These installation and operating instructions contain basic instructions and important information regarding safety, installation, com-
missioning, maintenance and the optimal use of the unit. Therefore these instructions must be read and understood completely by the
installation
technician/specialist and by the system user before installation, commissioning and operation of the unit.
This unit is an automatic, electrical Symondo Controller WLAN. Install the unit only in dry areas and under the ambient conditions
described in “Specifications”.
In addition, observe the applicable accident prevention regulations, the regulations of the Association of Electrical Engineering, the
local power supply utility, the applicable DIN-EN standards and the installation and operating instructions for the additional system
components. Installation, electrical connection, commissioning and maintenance of the device may only be carried out by an appro-
priately trained specialist.
Users: Make sure that the specialist gives you detailed information on the function and operation of the unit. Always keep
these instructions in the vicinity of the unit.
The manufacturer does not take over any liability for damage caused through improper usage or non-compliance of this manual!
Before working on the unit, switch off the power supply and secure it against being switched on again! Check that there is
no power flowing! Electrical connections may only be made by a specialist and in compliance with the applicable reg-
ulations. The unit may not be put into operation if there is visible damage to the housing, e.g. cracks.
Changes to the Unit
lChanges, additions to or conversion of the unit are not permitted without written permission from the manufacturer.
lIt is likewise forbidden to install additional components that have not been tested together with the unit.
lIf it becomes clear that safe operation of the unit is no longer possible, for example because of damage to the hous-
ing, turn the Unit off immediately.
lAny parts of the unit or accessories that are not in perfect condition must be exchanged immediately.
lUse only original spare parts and accessories from the manufacturer.
lMarkings made on the unit at the factory must not be altered, removed or made illegible.
lOnly the settings described in these instructions may be set using the Unit.
Changes to the unit can compromise the safety and function of the unit or the entire system.
3

Warranty and Liability
The Unit has been manufactured and tested with regard to high quality and safety requirements. The warranty and liability shall not
include, however, any injury to persons or material damage that is attributable to one or more of the following causes:
lFailure to observe these installation and operating instructions.
lImproper installation, commissioning, maintenance and operation.
lImproperly executed repairs.
lUnauthorised structural changes to the unit.
lUse of the device for other than its intended purpose.
lOperation above or below the limit values listed in the ‚Specifi cations‘ section.
lForce majeure.
Disposal and Pollutants
The unit conforms to the European RoHS 2011/65/EU for the restriction of the use of certain hazardous substances in electrical and
electronic equipment.
Under no circumstances may the device be disposed of with the normal household waste. Dispose of the unit only
at appropriate collection points or ship it back to the seller or manufacturer.
4

DESCRIPTION SYMONDO CONTROLLER WLAN
Technical Data
2-part, ABS plastic
75 mm x 95 mm x 19 mm
Glass front
Capacitive touch panel
Color display with 240x320 dots
2.8 inches (7 cm) diagonal
Intuitive user guidance
Deutsch
English
Español
Italiano
Français
Português
Electrical specifications:
Power Supply 12 - 24 VDC +/- 10%
power consumption max. 2,5 W
Protection Class IP20
Protection class / overvoltage category 0/III
Max. Cable Length
0-10V/PWM <3m, if the cable length is >=3m it is necessary to use a shielded twis-
ted pair bus cable and connect the shield on one side to the protective
conductor.
1-Wire Bus Optional, without function
Permissible Ambient Conditions
during operation 0 °C - 50 °C, no moisture condensation permitted
for transport/storage 0 °C - 60 °C, no moisture condensation permitted
Measurement Range Outside the measuring ranges there are larger deviations
Internal temperature sensor 0 °C - 60 °C Accuracy +/- 1 °C
Resolution 0,1 °C
Internal sensor for rel. humidity 0 % - 100 % Accuracy +/- 6 °C
Resolution 0,1 %
1-Wire temperature sensors Optional, without func-
tion
After switching on or disconnecting from the mains, it takes up to 60 minutes until the temperature is displayed precisely.
Other Specifications
Installation Methods Wall installation, with/without wall socket
Real Time Clock RTC with 24 hour power reserve
Scope of Supply
lSymondo Controller WLAN
l2 screws 3,5 x 35 mm and 2 plugs 6 mm for wall installation.
lSymondo Controller WLAN installation guide
5

INSTALLATION
Symondo Controller WLAN installation
Mount the unit at a suitable location.
Pay attention to suitable environmental conditions.
Direct sunlight, sources of heat and cold, e.g. radi-
ators and windows must be avoided.
When wall mounting, make sure that the cables are kept as
short as possible (max. 40 mm for direct wall mounting), as
unnecessary vein loops in the Symondo Controller WLAN
housing can lead to problems.
When mounting on a switch box, make sure that the cables
are kept as short as possible (strip cables max. 55 mm) and
that any vein loops are fed back into the switch box, as unne-
cessary vein loops in the Symondo Controller WLAN housing
can lead to problems.
Strip the last 8 - 9 mm of the wires. Isolate shielding and con-
nect it at a suitable location (controller or CAN-box) to the pro-
tective conductor.
Any contact between protective conductor and cir-
cuit board can cause serious damage.
Mounting on plastic wall socket
Fix the base with the screws (3,0 x 16) to the mounting box.
Direct wall mounting
Hold the lower part of the housing up to the selected position
and mark the three mounting holes. Make sure that the wall
surface is as even as possible so that the housing does not
become distorted when it is screwed on. Using a drill and drill
holes at the points marked on the wall and push in the plugs.
Insert screws and screw it in slightly. Align the base and
tighten the screws.
Open the terminals with the accompanying operating tool and
make the electrical connection as described.
Power supply 24 VDC, ensure correct polarity or it
may cause damage to the unit!
6

The first and last unit in the CAN-network in series
must be fitted with terminating resistance.
The connection of the opposite side (controller) can be found
in the corresponding terminal diagram in the controller
manual.
Refit the base and fasten with screw. Switch on the mains
voltage and put Symondo Controller WLAN into operation.
The setup wizard can be called up at any time in
the Symondo Controller WLAN menu under
Expert.
7

Example Controller-Connection
Example CAN-Connection
*Only CAN in power supply from 4 cores of the regulator.
The order and the number of devices (max. 50) is arbitrary.
8

OPERATION
Room Overview
Displays the room temperature, humidity and external temperature once the start screen was activated.
Room icon
Selecting a room icon takes you to the
room temperature settings.
Multiroom selection
By dragging your finger vertically
across several rooms, you can change
the operating mode in all rooms at the
same time.
outdoor temperature
Displayed as soon as an outdoor
sensor is used on the HCC or an out-
door sensor is activated on a Symondo
Box in the menu "Expert > Symondo
Box > Heating circuit > Sensor out-
door".
%
Room humidity
Relative humidity.
°C
Room temperature
Current room temperature.
9

Operating Mode
Overview > Operating Mode
Back/ Forward
Navigate back to the overview.
Room
Displays the selected space.
Reference temperature
Setting the reference temperature for
the active operating mode in the dis-
played room.
Menu
Navigate to the main menu
Operating Modes
The operating mode shown in colour
is currently active and can be changed
by selecting another mode. Manually
selected modes remain active until the
next change of mode by the timer pro-
gram. A background frost protection
function remains active in the "off"
mode.
Menu
Overview > Operating Mode > Menu
Heating/cooling
Switch between heating and cooling
modes.
Holiday
Set the period and temperature for a
longer absence.
Timer
Setting of individual heating or cooling
times for each day of the week with
copy function for subsequent days.
Expert
Advanced settings for the technician.
10

Set Operation Hours
Overview > Operating Mode > Menu > Timer
Setting of individual heating and cooling times for the selected room.
Separate times are set for the heating and cooling modes. To do this, first switch to the heating mode and define the corresponding
times for this operating mode under Main menu > Timer. Then change to the cooling mode and define the corresponding times for
this operating mode under Main menu > Timer.
Operating Modes
Selection of the operating mode to
select individual heating or cooling
sections.
Clock
Time table of the selection in periods
of 30 minutes increments. Touch indi-
vidual segments, or drag your finger
over complete time intervals to colour
them according to the selected oper-
ation mode.
Menu
Opens the copy function. The function
allows you to copy the heating and
cooling times to the following day, to
Monday - Friday or to Monday -
Sunday.
Back / Next Weekday
Selects the set day.
11

Set Operation Hours
Step 1
Use the arrow keys to select the
desired day.
Step 2
Select the first heating mode
(Normal) - with the index finger
select the desired length of
time. The selected period will
be coloured after selecting the
colour of the operating mode
(normal = orange). Set the
times of the other operating
modes in the same way.
Step 3
After completing the setting of
the individual heating or cooling
times, you have the option of
copying the times via the main
menu to the following day, to
Monday - Friday or to Monday -
Sunday or to set them indi-
vidually for each day of the
week.
In the interests of efficient and energy-saving single room control, the operating times should be set specifically for each
room.
12

Expert Menu
Overview > Operating Mode > Menu > Expert
Select Language
Set the device language.
Settings
Parameterisation of heating/cooling
system.
Menu Lock
Activate menu lock to protect settings
with a password.
Date & Time
Setting of time and date and auto-
matic summer/winter time
changeover.
Service Values
Information about the system.
Factory settings
The factory settings are restored in
the device.
The menu structure described here is based on the status at the time of production and may vary due to subsequent soft-
ware changes.
Settings
Overview > Operating Mode > Menu > Expert > Settings
Devices
Add, manage and remove connected
devices
Symondo Controller
Assignment and configuration of addi-
tional functions for free switching out-
puts.
Display Brightness
Adjust the screen brightness.
.
Rooms
Add, manage and remove rooms and
assign them to connected devices.
WiFi
Set and manage WiFi functions.
Interface Mode
Switch between full and restricted
menu. Only the reference temperature
can be set in the mode "Hide menu".
To return to "full" mode, press and
hold the upper-right corner of the dis-
play for 5 seconds.
Room Sync.
If room synchronisation is activated,
rooms set up on other Symondo Con-
troller of the same network are also
displayed on this Symondo Controller
and vice versa.
13

Devices
Overview > Operating mode > Menu > Expert > Settings > Devices
Clima systems have to be switched to 'heating' mode before another device can be added to a running system.
Add Device
Starts the search for new available
devices in the network.
Device icon
Shows the type of connected device
and its CAN ID.
Description
Displays the detected type of the
device.
Remove devices
Devices are removed from the net-
work.
Add a Symondo Sensor WLAN /
Symondo Sensor WLAN to your net-
work.
For the commissioning of the
Symondo Sensor WLAN / Symondo
Sensor WLAN, please refer to the
enclosed operating instructions.
14

Rooms
Overview > Operating mode > Menu > Expert > Settings > Rooms
Add Room
Adding rooms.
Room 2
Setting the location, sensors and actu-
ators of the respective room.
Overview > Operating mode > Menu > Expert > Settings > Room 2
Location
Selection of room icon.
Modulation Humidity
Sensors in the selected room.
Remove Room
Remove the selected room.
Temperature
Sensors in the selected room.
Hysteresis
Switch-off hysteresis for the room set-
point temperature.
15

Sensors
Overview > Operating mode > Menu > Expert > Settings > Rooms > Room 1 > Sensors > Temperature
Icon
Sensor already selected.
Sensoricon with CAN ID + number
Temperature sensor selection in the
selected room.
Overview > Operating mode > Menu > Expert > Settings > Rooms > Room 1 > Sensors > Humidity
Sensoricon with CAN ID + number
Humidity sensor selection in the selec-
ted room.
16

Functions
Overview > Operating mode > Menu > Expert > Settings > Functions
Activate and set additional functions.
Thermostat 1
Season switch
Fan coil 1
Dehumidifier
Timer 1
Overview > Operating mode > Menu > Expert > Settings > Functions > Thermostat 1
Switches the defined output to the set room / rooms depending on time and temperature.
Output
Assign the output to be switched by
the function. The other menu
options become visible after assign-
ing the output.
Operating Mode
Set the operating mode of this ther-
mostat function. Heating, cooling,
or heating and cooling.
Seizing Protection
If the seizing potection is activated
(daily, weekly, off), the controller
switches on the outputs one after
the other at 12:00 noon for 5
seconds to prevent seizing of the
connected device during longer
inactivity.
Room
Selection of the sensors on whose
settings and states the function is to
be based.
Relay Modus
Switching mode of the output
Normal/Inverted.
17

Overview > Operating mode > Menu > Expert > Settings > Functions > Dehumidifier
The dehumidifier function switches the defined output depending on the set humidity in the set room(s).
Output
Assign the output to be switched by the
function. The other menu options
become visible after assigning the out-
put.
Modulation Humidity
Set the limit value for the air humidity. If
this is exceeded, the dehumidifier is
switched on.
Room
Room selection for assigning the
humidity of a room as the basis for
switching the dehumidifier.
Operating Mode
Specify in which operating states of the
heating and cooling system the dehu-
midifier is to be switched on.
Hysteresis
Define the switch-off hysteresis.
Seizing Protection
If the seizing potection is activated
(daily, weekly, off), the controller
switches on the outputs one after the
other at 12:00 noon for 5 seconds to
prevent seizing of the connected
device during longer inactivity.
Overview > Operating mode > Menu > Expert > Settings > Functions > Season Switch
The seasonal switch changes the operating mode of the heat pump (compressor) between "heating" and "cooling". Therefore the
heat pump (compressor) must be compatible with reversible operation.
Output
Assign the output to be switched by
the function. The other menu options
become visible after assigning the out-
put.
Seizing Protection
If the seizing potection is activated
(daily, weekly, off), the controller
switches on the outputs one after the
other at 12:00 noon for 5 seconds to
prevent seizing of the connected
device during longer inactivity.
Room
Room selection to start the function.
As soon as one of the assigned rooms
switches from "heating" mode to "cool-
ing" mode the season switch becomes
active and the assigned relay is
switched.
18

Overview > Operating mode > Menu > Expert > Settings > Functions > Timer 1
The function Timer 1-2 switches the defined output depending on the set times.
Output
Assign the output to be switched by
the function.
The other menu items become vis-
ible after the output has been
assigned, as soon as at least one
created room has a heat demand.
Seizing Protection
If the seizing potection is activated
(daily, weekly, off), the controller
switches on the outputs one after the
other at 12:00 noon for 5 seconds to
prevent seizing of the connected
device during longer inactivity.
Timer
Set the times at which the outputs are
to be switched.
19

Overview > Operating mode > Menu > Expert > Settings > Functions > Fan coil 1
The fan coil function controls convection heating and cooling via the 0-10V/PWM outputs .
Output
Assign the output to be switched by the
function.
The other menu options become
visible after assigning the output.
Flow
Assignment of the convector flow
sensor in "Heating" mode.
Room
Selection of the sensors on whose set-
tings and states the function is to be
based.
Operating Mode
Set the operating mode of this con-
vector function. Heating, cooling, or
heating and cooling.
Delay
Delays the switching on of the fan coil
so that it does not push against closed
valves.
Modulation Humidity
Set the limit value for the air humidity. If
this is exceeded, the dehumidifier is
switched on.
Hysteresis
Define the switch-off hysteresis.
Modulation
Modulation of the output for power con-
trol
Signal type
Selection of the control:
0-10V = voltage signal
PWM = square wave signal
Relay Modus
Switching mode of the output
Normal/Inverted.
Off Signal
Signal to switch off the target device
On Signal
Signal to switch on the target device at
minimum power
Max Signal
Signal to set target device to maximum
power
Seizing Protection
If the seizing potection is activated
(daily, weekly, off), the controller
switches on the outputs one after the
other at 12:00 noon for 5 seconds to
prevent seizing of the connected
device during longer inactivity.
20
Table of contents
Other Symondo Controllers manuals
Popular Controllers manuals by other brands

HP
HP 9000 Series 300 Service handbook

Cutler-Hammer
Cutler-Hammer S801N Quick setup guide

ABB
ABB Galaxy Millennium J2011002 product manual

DFE
DFE SW6 operating instructions

Precision Digital Corporation
Precision Digital Corporation PROVU PD6310 instruction manual

Viz-Art Automation
Viz-Art Automation SMART Box 2.0 manual