3C
How To Control TheUnit
Thisfixtureisdesigned tooperateasastand-alone unitormaster/slavelink. Bylinking
the unitsinmaster/slaveconnection, the first unit will controlthe otherunitstogivean
automaticsound activated synchronized light show.Thisfunction isgood when you
want an instant show. Just plug inand playforimmediateoperation. You will know
whichunit isthe masterbecauseitsyellowLEDwill light and, the otherunits(slaves)
LEDwill no light. It will turnoffthe laserdiode automaticallywhen the musicstops after
7secondsorno signalinput.
1. Power switch : Turnon/off the unit.
2. Power cord : Thisconnection suppliesmainpowertothe fixture. Besurethe main
powermatchesthe required powerofyourfixture.
3. Fuseholder : Thishousing storesthe protectivefuse. Alwaysreplacewiththe extra
sametype fuse. Replacement withanything otherthan the specified part may
damage yourunit.
4. Red LED : Showing the laserdiode on/off.When the LEDislight. The laserdiode is
working.
5. Yellow LED : Showing the Mastermode. When the LEDislight. It isinmaster
mode.
6. Mode : Select the master/slavermode. When you press the button, the yellowLED
willlight, itisinmastermode.If not, itisinslavermode.TheyellowLEDwillnolight.
7. Signal input/output : usesa 3.5mm stereo microphone cabletolinkthe unit
togetherformaster/slavelink.
8. Remotecontroller input : usesa1/4"microphone jack connected tothe first unit.
Whenyou press the button,you will find that the remotecontrolleronthe firstunit will
controlsall the otherlinked unitsforstand by, and switchoffthe laser diode.
CAUTION:Use ofcontrolsoradjustmentsorperformance ofprocedures other
than as specified herein may resultin hazardousradiation exposure.
Troubleshooting
Ifthe unit isnot functional –check mainpowersupplyis ‘on’and check fuses.
Ifthe unit isnot moving tothe musiccheck the sound-activation adjustment (when
applicable)
Ifaftertrying thissolution you still haveaproblemcontact yourdealerabout
authorized technicalassistance.
Caution
Do not obstruct the airvents.
Do not touchunit whilehot.
No userserviceablepartsinside pleasereferto the nearest authorized technical
assistanceoffice forservice.
Power Connections
The unit issupplied withapowerplug appropriatetoitsvoltage and destination.
Shouldanyotherconnectionsbe required theymust be carried out withthe following
configuration.
Earth=Green/Yellowcable
Neutral=Blue cable
Live=Browncable
Inthe USA &Europe, it isrequired that all plugsare3-pintype i.e. withEarth/Ground
connection.
Inthe UK, it isrequired that all mainsplugsarefitted with5Afuses.
Technical Specifications
SyncroLaser-R SyncroLaser-G
PowerAC120V60Hz/ 230V-250V50/60Hz
Fuse20mm Glass 2AFast Blow
Laserdiode Red laserdiode Green laserdiode
Wavelength650 nm532 nm
Dimensions260 x230 x210 mm / 10.2x9.1x8.3in
Weight3.7kg/ 8.14 lbs