syndome ECO II-LED 1000 User manual

User Manual
Line-interactive UPS
ECO Ⅱ-LED 1000 / ECO Ⅱ-LCD 1000
IMPORTANT SAFETY INSTRUCTIONS
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and
operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of
conductive contaminants. (See the specifications for the acceptable temperature and humidity range.)
2.With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage device
(Zip drive, Jazz drive, Tape drive), etc. into the battery power supplied outlets. DO NOT plug a laser printer, copier,
space heater, vacuum, paper
shredder or other large electrical device into the battery power supplied outlets. The power demands of these devices
will overload and possibly damage the unit.
3.Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a
fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner, refrigerator,
copier, etc. Avoid using extension cords.
4.Press the power switch to turn the unit on. The power on indicator light will illuminate and the unit will "beep".
5.If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off
and unplug at least one piece of equipment from the battery power supplied outlets. Wait 10 seconds. Make sure the circuit
breaker / fuse is normal and then turns the UPS on.
6.To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7.To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery every
three months to ensure battery life.
CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid exposing the unit to
direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces.
CAUTION! Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens,
or vacuum cleaners to UPS.
CAUTION! Do not plug the UPS input into its own output.
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing
vessels on or near the unit.
CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to
properly disable the UPS.
CAUTION! Do not attach a power strip or surge suppressor to the UPS.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the
required precautions. Keep unauthorized personnel away from batteries.
CAUTION! The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the
battery when maintenance or service work inside the UPS is necessary.
CAUTION! Internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery.
CAUTION! When replacing the batteries, use the same number and type of batteries.
CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries.
Released electrolyte is harmful to the skin and eyes.
INSTALLING YOUR UPS SYSTEM
UNPACKING
The box should contain the following:
(1) UPS Unit x1; (2) User Manual x 1
OVERVIEW
The UPS provides automatic voltage regulation for inconsistent utility power, and provides battery backup during power
outages, and ensures consistent power to your computer system.
HARDWARE INSTALLATION GUIDE
1.Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is
recommended to ensure that the battery's maximum charge capacity is achieved. Charge loss may occur during shipping
and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will charge in both the on
and off position.
BASIC OPERATION
Front panel
1. Power Switch
Press the switch for 2 seconds to turn the UPS ON/OFF
2. Power On Led Indicators
This LED is illuminated when the UPS is working.
3. LCD Display
The LCD will display the UPS status including input
voltage, output voltage, percentage of load and
battery…etc.
4. AC Mode LED
The green LED will light when utility power is
normal.
5. Battery Mode LED
The yellow LED will light when input power is
abnormal and the unit will work in battery mode.
6. Fault LED
The red LED will light when fault or over load
occurs.
Rear panel
1. Battery Backup & Surge Protected Outlets
Provide battery backup and surge protection. They ensure
power is provided to connected equipment over a period of
time during a power failure.
2. USB COMM. Port
This port allows connection and communication from the
USB port on the computer to the UPS unit.
3. Input power cord
Connect to utility power.
4. Surge Protected Outlets
Provides surge protection for devices that don’t
require battery backup.
ECO Ⅱ-LCD 1000 ECO Ⅱ-LED 1000
ECO Ⅱ-LED 1000 ECO Ⅱ-LCD 1000

TECHNICAL SPECIFICATIONS
Model
ECO Ⅱ-LED 1000
ECO Ⅱ-LCD 1000
Capacity (VA/W)
1000/630
1000/630
Input
Nominal Frequency
220Vac
Nominal Frequency
50/60Hz
Output
On Battery Output Voltage
Simulated Sine Wave at 220Vac +/-10%
On Battery Output Frequency
50/60Hz +/-1%
Overload Protection
Fuse
Physical
Dimensions (W x H x D)(mm)
96 x 138 x 286
Battery
Sealed Maintenance
12V 9AH x1
Free Lead Acid Battery
Typical Recharge Time
8 Hours
Warning Diagnostics
Indicators
Power On
Audible Alarms
On Battery, Low Battery, Overload, Fault
Display
LED
LCD
Environmental
Operating Temperature
0℃to 40℃
Operating Relative Humidity
0 to 90%
Management
Auto-Charger
Yes
Auto-Restart
Yes
USB COMM. Port
NA
Yes
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
LCD Indication
Setting Item
Line mode
PV mode
Bat-mode
Sound disable
Fault
(Press the display key 3s to disable
and enable the buzzer sound)
Bat mode: battery capacity
Line mode:
1.
Battery charging: cycle lighting
Load capacity
2.
Battery full charged: lighting
3.
Line mode without charger:
battery capacity
Line mode & Batt. Mode
Initial
AC INPUT(Voltage)
OUTPUT
(Voltage)
V
V
TROUBLE SHOOTING
Problem
Possible Cause
Solution
The UPS does not
Batteries are not fully charged.
Recharge the battery by leaving the UPS plugged in.
perform expected
Battery is slightly worn out.
Contact Technical Support.
runtime
The on/off switch is designed to prevent
Turn the UPS off. Wait 10 seconds and then turn the
damage by rapidly turning it off and on.
UPS on.
El UPS no se
The unit is not connected to an AC outlet.
The unit must be connected to a 120Vac 50/60Hz outlet.
enciende.
The battery is worn out.
Contact Technical Support.
Mechanical problem.
Contact Technical Support.
Circuit breaker is tripped due to overload
Turn the UPS off and unplug at least one piece connected
equipment. Unplug the power cord of the UPS then press
Outlets do not
the circuit breaker knob.
provide power to
Batteries are discharged
Allow the unit to recharge for at least 4 hours.
equipment
Unit has been damaged by a surge or
Contact Technical Support.
spike
SOFTWARE DOWNLOAD
Power Guide management software provides a user-friendly
interface for your power systems. The graphic user-interface is
intuitive and displays essential power information at a glance.
Please follow procedure below to install the software.
Installation procedure:
1.Download Power Guide from the website:
http://www.powermonitor.software/
2.Double-click the file and follow the installation steps. When
your computer restarts, the Power Guide software will appear as
a blue icon located in the system tray.
K01-C000349-00
All rights reserved. Reproduction without permission is prohibited
This manual suits for next models
1
Other syndome UPS manuals
Popular UPS manuals by other brands

MGE UPS Systems
MGE UPS Systems Pulsar 700 manual

Liebert
Liebert PowerSure PS250-50S, PS400-50S user manual

Beckhoff
Beckhoff CU8110-0060 manual

Marathon Power
Marathon Power TRTC-2004-N1 quick start guide

Ametek
Ametek Surgex UPS-17202-53R user manual

MGE UPS Systems
MGE UPS Systems Pulsar EXtreme2000 Installation and user manual