WARNING
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try correct the
interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
If applicable, as below
FCC Caution: To assure continued compliance, (example – use only shielded
interface cables when connecting to computer or peripheral devices). Any changes
or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20 cm between the radiator & your body.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.

Table of Contents
REVISION HISTORY...........................................................................................1
1. INTRODUCTION...........................................................................................2
2. 3666 INSTALLATION...................................................................................3
2.1 POWER UP THE 3666 BASE STATION..........................................................3
2.2 POWER UP THE 1166/1266.........................................................................4
2.3 SETUP RF CONNECTION.............................................................................4
2.4 CHARGING YOUR 1166/1266......................................................................5
2.4.1 Scanner .............................................................................................5
2.4.2 Battery...............................................................................................5
2.4.3 DC Jack.............................................................................................6
2.5 INTERFACE SETTING ..................................................................................6
3. GENERAL FEATURES ................................................................................7
3.1 BUZZER......................................................................................................7
3.2 INDICATOR.................................................................................................7
3.3 SCAN MODES.............................................................................................7
3.4 AUTO-SENSE..............................................................................................8
3.5 RE-READ DELAY........................................................................................9
3.6 SCANNER TIME-OUT DURATION ................................................................9
3.7 READING REDUNDANCY ............................................................................9
3.8 SUPPORTED SYMBOLOGIES ........................................................................9
3.9 NEGATIVE BARCODES..............................................................................10
4. OUTPUT INTERFACE (3666 BASE UNIT) .............................................11
4.1 KEYBOARD WEDGE INTERFACE...............................................................11
4.1.1 Keyboard Type................................................................................11
4.1.2 Keyboard Style - Alphabets.............................................................11
4.1.3 Keyboard Style – Digits ..................................................................11
4.1.4 Capital Lock Status.........................................................................12
4.1.5 Alphabets Transmission..................................................................12
4.1.6 Digits Transmission ........................................................................12
4.1.7 Inter-Character Delay.....................................................................12
4.2 RS232 INTERFACE...................................................................................13
4.2.1 Baud Rate / Parity / Data Bits.........................................................13
4.2.2 Flow Control...................................................................................13
4.2.3 Inter-Character Delay.....................................................................13
4.3 USB INTERFACE ......................................................................................13
4.4 MEMORY PARAMETERS ...........................................................................13
4.4.1 Transmit Buffer Setting...................................................................14
4.4.2 Memory Mode.................................................................................14
4.4.3 Clear Data......................................................................................14
4.4.4 Send Data........................................................................................14
4.4.5 Memory Data Delay........................................................................14
5. BLUETOOTH SERIAL PORT...................................................................15
5.1 CONFIGURING 1166/1266........................................................................15
5.1.1 Activate Bluetooth Serial Port Interface.........................................15
5.1.2 Authentication & PIN Code............................................................15
5.1.3 Device Name Broadcasting ............................................................15
5.1.4 Update Settings...............................................................................16
5.1.5 Timeout...........................................................................................16
5.2 CONFIGURING BLUETOOTH DEVICE DRIVER ...........................................16
5.2.1 Windows XP with Service Pack2 .................................................... 16
5.2.2 Belkin Bluetooth Driver..................................................................18
6. BLUETOOTH HID......................................................................................22
6.1 CONFIGURING 1166/1266........................................................................22
6.1.1 Activate Bluetooth HID Interface ...................................................22
6.1.2 Reset Connection ............................................................................23
6.1.3 Authentication & PIN Code............................................................23
6.1.4 Device Name Broadcasting ............................................................23
6.1.5 Update Settings...............................................................................23
6.2 HID KEYBOARD INTERFACE....................................................................23
6.2.1 Keyboard Type................................................................................23
6.2.2 Keyboard Style - Alphabets.............................................................23
6.2.3 Keyboard Style – Digits..................................................................23
6.2.4 Capital Lock Status.........................................................................24
6.2.5 Alphabets Transmission..................................................................24
6.2.6 Digits Transmission........................................................................24
6.3 CONFIGURING BLUETOOTH DEVICE DRIVER ...........................................25
6.3.1 Windows XP with Service Pack2 .................................................... 25
6.3.2 Widcomm Bluetooth Driver ............................................................27
7. SYMBOLOGY PARAMETERS.................................................................30
7.1 CODE39...................................................................................................30
7.2 ITALY /FRENCH PHARMACODE ...............................................................30
7.3 INDUSTRIAL /INTERLEAVE /MATRIX 25..................................................30
7.4 CODABAR ................................................................................................31
7.5 UPCE......................................................................................................31
7.6 EAN8......................................................................................................32
7.7 UPCA......................................................................................................32

7.8 EAN13....................................................................................................32
7.9 MSI .........................................................................................................32
7.10 PLESSEY...................................................................................................33
7.11 TELEPEN ..................................................................................................33
7.12 RSS .........................................................................................................33
8. DATA OUTPUT FORMAT.........................................................................35
8.1 CHARACTER SUBSTITUTION.....................................................................35
8.2 PREFIX /POSTFIX CODE ...........................................................................35
8.3 CODE ID ..................................................................................................35
8.4 LENGTH CODE .........................................................................................36
9. DATA EDITING...........................................................................................37
9.1 SELECT EDITING FORMAT........................................................................37
9.2 RESTORE DEFAULT FORMAT....................................................................37
9.3 APPLICABLE CONDITIONS........................................................................38
9.4 TOTAL NUMBER OF FIELDS......................................................................38
9.5 DIVIDING DATA INTO FIELDS...................................................................38
9.6 ADDITIONAL FIELDS ................................................................................39
9.7 FIELD TRANSMISSION SEQUENCE.............................................................39
9.8 END OF FORMAT PROGRAMMING.............................................................39
9.9 ACTIVATE DATA EDITING FORMATS........................................................39
9.10 EXCLUSIVE DATA EDITING......................................................................40
9.11 PROGRAMMING EXAMPLES......................................................................40
10. CONFIGURING YOUR 1166/1266 ........................................................41
10.1 ENTER CONFIGURATION MODE................................................................41
10.2 DEFAULT .................................................................................................41
10.3 LIST SETTING...........................................................................................41
10.4 SETTING PARAMETER VALUES.................................................................42
10.4.1 Numeric Parameters.......................................................................42
10.4.2 Character String Parameters..........................................................42
10.4.3 Key Type/Status Setting...................................................................43
10.5 EXIT CONFIGURATION MODE...................................................................44

1
Revision History
Version Release
Date Notes
V 1.00 Oct. 31, 2005 First release.
V 2.00 Dec. 30, 2005 Supports Bluetooth HID.
Firmware version : V4.10.
V2.10 Jan.18, 2006 Updated:
zBluetooth HID doesn’t support
the following functions on PDA
for Win CE.
Capital Lock Setting: Auto
Detection
Digit Transmission:
Numeric Key
Alt Composing
zHID Keyboard Interface information is
added.
Firmware version: V4.20
2
1. Introduction
The 1166/1266 is CipherLab Wireless scanner utilizing Bluetooth Technology. The
scanner has a range of over 50 meters and a battery life is over 50 hours or 35,000
scans for1166 and over 36 hours or 26,000 scans for 1266. The difference between
1166 and 1266 is the barcode scan engine installed inside the scanner. The 1166
scanner uses CCD linear imager, whereas the 1266 scanner uses a Laser engine.
This manual contains the information for operating and configuring the 1166/1266
Wireless Barcode Scanner and is divided into two portions. The first portion
describes the installation, operation and programmable features of the scanner. The
second portion contains the setup barcodes used to configure the scanner.
The 1166/1266 is one of the most versatile and flexible wireless barcode scanners
available today. The 1166/1266 contains all the features and functions required for
up to date barcode reading. Owing to the compact design and extremely low power
consumption, this scanner provides for easy installation and high product
durability. The scanner will not only satisfy for the requirements needed today, but
also can fulfill your long-term needs. The main functions and features are listed
below.
•Barcode Readability: Most popular barcode symbologies are supported including
the newest RSS Code.
•Negative barcodes supported.
•Eight scan modes supported.
•Programmable Beeping Tone
•Dual Color Indicator
•Interface Support (base unit): KB Wedge, RS232, and USB
•Bluetooth Serial Port Profile Supported: The scanner can transmit scanned data
to Bluetooth enabled computer/PDA via standard Bluetooth Serial Port
communication.
•Bluetooth HID Supported: The scanner can transmit scanned data to Bluetooth
enabled computer/PDA via standard HID communication.
•Programmable Code ID: Code ID can be individually configured for each
symbology.
•Programmable Length Code
•Programmable Prefix Code
•Programmable Postfix Code
•Character Substitution
•Data Editing: Data can be reorganized according to user programmable formats.
Up to three data editing formats are supported.
•Extremely Low Power Consumption

3
2. 3666 Installation
The 1166/1266 kit contains:
A 1166/1266 wireless barcode scanner
A 3666 base
A rechargeable battery
A Serial/Keyboard/USB Cable (depending on configuration ordered)
A power supply for the base or the scanner.
Diskette containing “Scan Manager” and this manual
Note: Please refer to chapter 5 Bluetooth Serial Port for
Bluetooth Serial Port installation and configuration
instructions.
2.1 Power Up the 3666 Base Station
Connect the interface cable into the 15-pin connector at the back of the base. The
interface of the cable depends on you ordered. There are three types of cables
available: RS232, Keyboard or USB.
Power off your PC or Laptop when connect the cable to PC or Laptop. Once your
cable is connected to the base, plug the other end into the appropriate port on your
PC. For example, if you have a serial cable then plug into the com port of your PC,
if you have a Keyboard cable then plug into keyboard port of your PC and if you
have a USB cable plug into the USB port on your PC.
Connect the power supply provided to your AC outlet and plug the other end into
the base then power on your PC.
Now you are ready to configure your scanner and base.
4
2.2 Power Up the 1166/1266
When you receive your 1166/1266, the battery is separated from 1166/1266. Please
insert the battery into the bottom of the scanner and lock the battery by pushing the
clip to power on the scanner. The scanner will beep and the LED will be on when
power on.
Please ensure to remove the battery to power off the scanner if it will not be used
for a prolonged period. The LED will be off and the power to the scanner will be
disconnected.
2.3 Setup RF Connection
Upon powering up the scanner will try to establish an RF connection with its base.
At this stage we need to “pair” the scanner and base.
Turn the base upside down and you will find 2 labels.
The first label has the words “SET CONNECTION” and a barcode. The second
label is the serial number.
To link the scanner to the base, scan the “SET CONNECTION” barcode label, the
scanner will beep once then scan the SERIAL number barcode. The scanner will
beep twice, low then high beep. When it establishes RF connection with the base
the scanner will then emit three short ascending beeps. Your “pairing” is
established.
Push up to lock the battery.

5
2.4 Charging your 1166/1266
There are three methods to charge the battery. One is placing the scanner on the
base and another is inserting the battery in front of the base, and the other is
inserting the power supply into the DC Jack at bottom of the scanner.
2.4.1 Scanner
Place the scanner with a battery inserted on the base to charge your scanner. When
charging, the scanner LED will flash RED. When the battery is fully charged,
around 4 hours from completely empty battery, the LED stays on solid RED.
2.4.2 Battery
Insert the battery in front of the base to charge your battery with the power adaptor
connected. When charging, the base charging LED will be RED. When the battery
is fully charged, around 4 hours from completely empty battery, the LED will be
solid GREEN.
6
2.4.3 DC Jack
Insert the power supply to the DC Jack at bottom of the scanner. When charging,
the scanner LED will flash RED. When the battery is fully charged, around 4 hours
from completely empty battery, the LED stays on solid RED.
2.5 Interface Setting
Once you have “paired” the scanner and base, you need to specify the interface
type to your PC. The interface settings are stored in the base. So ensure that you
have RF connection between your scanner and base prior to setting the interface
type. For details on selecting interfaces please refer to the relevant section in this
manual.

7
3. General Features
3.1 Buzzer
The buzzer of the scanner beeps differently to indicate various operating
conditions.
•Power On Beep: The scanner will issue a long beep to indicate a successful
power on.
•Good Read Beep: The system provides four volume levels and four beeping
tones (frequencies) that the user can select from to signify a good read. The
available options are:
Volume: Maximum/Loud/Medium/Minimum
Frequency: 8 / 4 / 2 / 1 kHz
•Error Beep: The scanner will issue a long beep with a low tone to indicate
errors.
•Enter / Exit Configuration Beep: The scanner will issue 6 beeps upon entering
/ exiting the configuration mode.
•Setup Beep: In configuration mode, the scanner will normally beep twice when a
setup barcode is read. If the particular setup parameter needs more than one read,
the scanner will only issue a short beep to indicate that there are more setup
barcodes needed to complete the current parameter setting.
3.2 Indicator
There is a dual color indicator on top of the scanner. Normally it is off, and will
turn red when there is a good read. The indicator will be blue when the scanner is
at configuration mode.
3.3 Scan Modes
There are eight scan modes supported by the scanner. The user can choose the
desired scan mode depending on the application requirements. But, if the scanner is
a trigger-less scanner, only continuous mode or testing mode can be selected (other
scan modes involve trigger switch interaction). The supported scan modes are
described below.
•Auto Off Mode: The scanner will start scanning once the switch is
triggered. The scanning continues until either a barcode is read or a preset
scanning period (Scanner Time-Out Duration) is expired.
8
•Continuous Mode: The scanner is always scanning.
•Auto Power Off Mode: The scanner will start scanning once the switch is
triggered. The scanning continues until a preset scanning period (Scanner
Time-Out Duration) is expired. Unlike the Auto Off mode, the scanner will
continue to scan and the scanning period is re-counted each time there is a
successful read.
•Alternate Mode: The scanner will start scanning once the switch is
triggered. The scanner will continue scanning until the switch is triggered
again.
•Momentary Mode: The scanner will be scanning as long as the switch is
depressed.
•Repeat Mode: The scanner is always scanning just like Continuous Mode.
But now the switch acts like a “re-transmit button”. If the switch is triggered
within 1 second after a good read, the same data will be transmitted again
without actually reading the barcode. This “re-transmit button” can be
triggered as many times as user desired, as long as the time between each
triggering does not exceed 1 second. This scan mode is most useful when
the same barcode is to be read many times.
•Laser Mode: This scan mode is used on laser scanners. The scanner will
scan once when the trigger is pressed. The scanning continues until a
barcode is read, the trigger is released or a preset scanning period (Scanner
Time-Out Duration) is expired.
•Test Mode: The scanner is always scanning. The scanner will decode
repeatedly even with the same barcode.
By default, the scan mode is Auto Off mode for scanners with trigger switch, and is
Continuous mode for switch-less scanners.
3.4 Auto-Sense
Auto-Sense is for 1166 only and used in conjunction with the auto-sense stand. It
will enable the scanner to start scanning once a barcode is brought within Range of
the scanner. This will activate the LEDs and the scanner will start decoding the
barcode. The auto-sense mode works only under Auto Off mode or Laser mode
only.

9
3.5 Re-read Delay
If the scanner mode is set to Continuous, Auto Power Off, Alternate, or Momentary
mode, the scanner will prevent accidentally reading the same barcode twice by
using a Re-read Delay (Blocking Time). The barcode must be taken away from the
scanning line longer than the Re-read Delay to allow second reading of the same
barcode. The user can set the Re-read Delay if necessary.
3.6 Scanner Time-out Duration
This parameter is used to limit the maximum scanning period when the scan mode
is either Auto Off Mode or Auto Power Off Mode. This time-out duration is
specified in units of second. The default time-out duration is ten seconds.
3.7 Reading Redundancy
This parameter is used to specify the levels of reading (decoding) security. If No
Redundancy is selected, only one successful decoding can make the reading valid.
If Three Times Redundancy is selected, it will take 3 successful decodes to make
the reading valid. It is obvious that the more redundancy the user selects, the higher
the reading security and thus the slower the reading speed. The user must
compromise between decoding security and decoding speed if the security feature
is needed.
3.8 Supported Symbologies
Most of the popular barcode symbologies are supported. Each symbology can be
individually enabled or disabled. The scanner will automatically discriminate and
recognize all the symbologies that are enabled. The supported barcode symbologies
are listed below.
•Code 39 (Standard / Full ASCII)
•Italy Pharmacode
•French Pharmacode
•Industrial 25
•Interleave 25
•Matrix 25
•Codabar (NW-7)
•UPCA (with or without Addon)
•UPCE (with or without Addon)
•EAN8 (with or without Addon)
10
•EAN13 (with or without Addon)
•Code 93
•Code 128
•EAN 128
•MSI
•Telepen
•Plessey
3.9 Negative Barcodes
The scanner can be configured to read negative barcodes. Normally, barcodes are
printed with the color of the bars darker than that of the spaces. But for negative
barcodes, they are printed in the opposite sense just like negative films. The spaces
of the negative barcodes are printed with a color darker than that of the bars.

11
4. Output Interface (3666 Base Unit)
The 1166/1266 is a multi-interface scanner. It can be used as a keyboard wedge
scanner, an RS-232 scanner, or a USB scanner. The output interface can be
programmed using the setup barcodes in this manual.
Please ensure that you have an RF connection between the scanner and the base
prior to selecting the interface type.
4.1 Keyboard Wedge Interface
4.1.1 Keyboard Type
The keyboard wedge interface is enabled by configuring/selecting keyboard type.
The supported keyboard types are listed below.
•PCAT - US, French German, Italian, Swedish, Norwegian, UK, Belgium,
Spanish, and Portuguese KBD
•PS2-30
•IBM 3477 TYPE (Japanese KBD)
•IBM 34XX, 319X & Memorex Telex (122Keys)
4.1.2 Keyboard Style - Alphabets
Keyboard layout style can be selected. There are three options to this setting:
default layout (US or English style), AZERTY layout, and QWERTZ layout. This
setting only works when the keyboard type selected is for US keyboard. The
scanner will make necessary adjustment when sending the ‘A’, ‘Q’, ‘W’, ‘Z’, ‘Y’,
and ‘M’ character according to this setting.
4.1.3 Keyboard Style – Digits
There are two digit layout styles as shown on the following figures. One has digit
on top (upper row) of a key and another has digits on bottom (lower row) of a key.
The digit layout style can be changed by the following configuration settings.
There are three options: Default, Lower Row, and Upper Row. The scanner will
make necessary adjustment when sending digits according to the setting value of
this parameter. This setting is used with the above setting (Keyboard Style –
Alphabets) and perhaps Character Substitution setting, when support to languages
not available on the scanner is needed.
! @ # $
1 2 3 4
Digits on Lower Row
12
4.1.4 Capital Lock Status
In order to send alphabets with correct case, the scanner needs to know the capital
lock status of the keyboard. Incorrect settings may result in reversed case of
alphabets being transmitted. There are 3 options to this parameter: On, Off, or Auto
Detection. If this parameter is set to Auto Detection, the scanner will automatically
detect the capital lock status of the keyboard before it transmits data.
4.1.5 Alphabets Transmission
User can choose how alphabets are sent by this parameter configuration. The
alphabets can be sent according to their case (the Case Sensitive option), or the
case is ignored (the Ignore Case option) when transmitting.
4.1.6 Digits Transmission
User can choose how the scanner transmits digits by configuring this parameter.
The scanner can transmit digits by using the alphanumeric key or by using the
numeric keypad. The Num Lock status of the keyboard should be ON if numeric
keypad option is selected.
4.1.7 Inter-Character Delay
An inter-character delay of 0 to 255 ms can be configured to match the computer
response time of the keyboard interface. The delay time configured is inserted
between transmitting every character. The longer the delay time configured, the
slower the transmission speed will be. The inter-character delay is zero by default.
1 2 3 4
! @ # $
Digits on Upper Row
Numeric Key Pad
Alpha Numeric Key

13
4.2 RS232 Interface
User can select the desired, flow control, baud rate, parity, and data bits to be used
in this output interface.
4.2.1 Baud Rate / Parity / Data Bits
The supported baud rate, parity, and data bit are listed below.
•Baud Rate: 115200 / 38400 / 19200 / 9600 / 4800 / 2400 / 1200 / 600
•Parity: None / Even / Odd
•Data bit: 8 / 7
4.2.2 Flow Control
The user can further configure the flow (handshake) control method to be used.
The available options are listed below.
•No Flow Control
•Scanner Ready: The scanner will activate the RTS signal after power on.
After each good read the scanner waits for an active CTS signal. The data
will not be sent until CTS signal becomes active.
•Data Ready: The RTS signal will be activated after each good read. The
scanner will then wait for the CTS signal becomes active. The data will not
be sent until CTS signal becomes active.
•Inverted Data Ready: It is like the Data Ready flow control, but the RTS
signal level is inverted.
4.2.3 Inter-Character Delay
An inter-character delay of 0 to 255 ms can be configured to match the computer
response time. The delay time configured is inserted between transmitting every
character. The longer the delay time configured, the slower the transmission speed
will be. The inter-character delay is zero by default.
4.3 USB Interface
A USB interface is also available. For installation instructions please refer to the
separate diskette included with your scanner.
4.4 Memory Parameters
The 1166/1266 reserves 4 KB flash memory as transmit buffer when the scanner is
out of service range. Data will be saved into the reserved buffer when the scanner
14
is out of signal range and data will transmitted to server when the scanner is back
to the service range.
The 1166/1266 can work offline and store the reading data into the internal Flash
memory for later upload to the host. The stored data can be up to 128Kbytes.
4.4.1 Transmit Buffer Setting
Please enable the transmit buffer by scanning transmit buffer setting ENABLE
label. Disable the manual memory function by scanning the DISABLE transmit
buffer setting.
4.4.2 Memory Mode
Please enable the manual memory function by scanning the memory mode
ENABLE label. Disable the manual memory function by scanning the DISABLE
memory mode label.
4.4.3 Clear Data
The CLEAR label will enable the user to CLEAR or ERASE the data in the
scanner’s memory. The user must also scan the CONFIRM label immediately after
the CLEAR label.
4.4.4 Send Data
This enables the user to transmit the data in the scanner’s memory to the host. The
interface selected by the user will be used for the transmission. During the
transmission the red LED of 1166/1266 will be flashing.
4.4.5 Memory Data Delay
This will enable the user to set a delay between each data records in memory at
time of transmission.

15
5. Bluetooth Serial Port
The 1166/1266 can be configured to the standard Bluetooth Serial Port as the data
output interface. This will make the 1166/1266 send the scanned barcode data to
Bluetooth enabled computer or PDA directly without the 3666 base unit (however,
a charging dock is still needed for charging the 1166/1266 battery).
This section illustrates a step-by-step installation and configuration procedures of
the 1166/1266 for Bluetooth Serial Port. Bluetooth transceivers/dongles always
come with their own driver or Windows XP with service pack2 provides the build-
in Bluetooth driver. There are several Bluetooth device drivers for Windows and
WinCE/Pocket PC from different companies. Here we use Window XP with
service pack2 build-in Bluetooth driver and BELKIN driver as examples. For detail
installation procedures, please refer to the user’s manual of the Bluetooth
transceiver in use.
5.1 Configuring 1166/1266
Before starting the configuration, the scanner must be powered up. If you have not
done so, please follow the procedures described in section 2.2 “Power Up the
1166/1266” to power up the scanner.
First step of the configuration is always to put the scanner in configuration mode
by scanning the “Enter Setup” barcode. After all the desired configurations are
done, the “Update” barcode must be scanned to save the new settings and put the
scanner back to normal operation mode.
5.1.1 Activate Bluetooth Serial Port Interface
Scan the “Activate Bluetooth Serial Port” barcode will change the interface type to
Bluetooth Serial Port.
5.1.2 Authentication & PIN Code
The 1166/1266 can do connection authentication if communication security is
desired. Once this setting is enabled, a user configurable PIN code is verified
during connection establishment. The scanner will refuse connection if the PIN
code is incorrect. User can specify up to six characters of PIN code.
5.1.3 Device Name Broadcasting
The scanner can be configured to hide itself by NOT broadcasting itself on the air.
This can avoid unwanted computer/PDA from connecting to the scanner. But for
the initial (first time) connection setup, this setting must be enabled. User can
disable this setting for security reasons after initial connection setup is completed.
16
5.1.4 Update Settings
After all the desired settings are completed, the “Update” barcode must be scanned
to make the new settings effective. The scanner will re-start itself after “Update”
barcode is scanned.
5.1.5 Timeout
The scanner will stay active only for one minute waiting for connection. If there is
no connection request during that period, the scanner will go to power down mode
to conserve power with three serial descending tones as indication. User can make
the scanner go back to active mode by pulling the trigger. And again, the scanner
will stay active for another one minute waiting for connection before it goes to
power down mode again. Once there is a successful connection, the scanner will
stay active until the connection is closed (when the host application closes the
COM port). After the connection is closed, the scanner will again wait for new
connection request for one minute before it goes to power down mode.
5.2 Configuring Bluetooth Device Driver
Please follow the procedures below to configure the Bluetooth driver on the host
system. Please note that, when searching nearby Bluetooth devices on Host
computers, the 1166/1266 will come out with the serial number as their device
name. Please check the serial number label on the scanner when making
connections.
5.2.1 Windows XP with Service Pack2
1. Insert the Bluetooth dongle into PC host.
2. Double click the Bluetooth icon on the lower right of the taskbar.
3. Check My device is set up and ready to be found and click Next button.

17
4. Select 1x66 scanner and click Next button for next step.
6. Enter the PIN code and click Next button for next step. The authentication PIN
code is always asked from the Window XP built-in driver, so the user has to set
1x66 scanner with Authentication and PIN code. In this case, 1 is the passkey.
18
7. The serial ports are assigned to the device, outgoing COM 10 and Incoming
COM 11. Click the Finish button to complete the configuration.
5.2.2 Belkin Bluetooth Driver
1. Click Go to My Computer.
2. Double click the My Bluetooth Places at left Folders window. Right click My
Device and select Property.

19
3. Select Client Applications tab and select Bluetooth Serial Port from the list then
click Property button.
4. Check Secure Connection if you enable the Authentication and have configured
a PIN Code on 1x66. Otherwise uncheck Secure Connection. Click Apply and
OK button.
20
5. Wake up 1166/1266 by pulling the trigger (just in case it falls asleep).
Double click Find Bluetooth Devices.
6. Double click 1x66 scanner.
7. Double click on the service, COM1, which is the Bluetooth Serial Port service.
This will enable the connecting process. If Authentication (Secure Connection)
is enabled, another window might pop up and asking for PIN code.

21
8. Click OK button.
After successful connection, the Bluetooth Device Driver will report the COM
port number, which is mapped for this connection. In this case, it is COM3.
You can also hear three serial ascending tones from the scanner indicating
successful connection.
After this initial connection, whenever an application program opens COM3,
the Bluetooth driver will automatically try to connect this particular scanner.
9. Right click the COM1 and select Disconnect to close the connection. There
will be three serial descending tones from the scanner to indicate this condition.
After the connection is closed, the 1x66 scanner and the Bluetooth driver are
properly configured and are ready to go. User can now run their application or
“Hyper Terminal” for testing, and make the best use of this scanner.
22
6. Bluetooth HID
The 1x66 scanner can be configured to the standard Bluetooth HID as data output
interface. This will make the 1x66 scanner sends the scanned barcode data to
Bluetooth enabled computer or PDA directly without the 3666 base unit (however,
a charging dock is still needed for charging the 1x66 battery).
This section illustrates a step-by-step installation and configuration procedures of
the 1x66 for Bluetooth HID. Bluetooth transceivers/dongles always come with
their own driver or Windows XP with service pack2 provides the build-in
Bluetooth driver. There are several Bluetooth device drivers for Windows and
WinCE/Pocket PC from different companies. Here we use Window XP with
service pack2 build-in Bluetooth driver and WIDCOMM driver as examples. For
detail installation procedures, please refer to the user’s manual of the Bluetooth
transceiver in use.
NOTE: Bluetooth HID doesn’t support the following functions on PDA:
Capital Lock Setting: Auto Detection
Digit Transmission: Numeric Key
Alt Composing
6.1 Configuring 1166/1266
Before starting the configuration, the scanner must be powered up. If you have not
done so, please follow the procedures described in section 2.2 “Power Up the
1166/1266” to power up the scanner.
First step of the configuration is always to put the scanner in configuration mode
by scanning the “Enter Setup” barcode. After all the desired configurations are
done, the “Update” barcode must be scanned to save the new settings and put the
scanner back to normal operation mode.
6.1.1 Activate Bluetooth HID Interface
The HID keyboard interface is enabled by configuring/selecting the HID keyboard
type. The supported HID keyboard types are listed below: US, French German,
Italian, Swedish, Norwegian, UK, Belgium, Spanish, and Portuguese KBD.

23
6.1.2 Reset Connection
Scan the “Reset Connection” when switch connection from one PC to another PC.
The scanner will re-start itself after this barcode is read.
6.1.3 Authentication & PIN Code
The 1x66 scanner can do connection authentication if communication security is
desired. Once this setting is enabled, a user configurable PIN code is verified
during connection establishment. The scanner will refuse connection if the PIN
code is incorrect. User can specify up to six characters of PIN code.
6.1.4 Device Name Broadcasting
The scanner can be configured to hide itself by NOT broadcasting itself on the air.
This can avoid unwanted computer/PDA from connecting to the scanner. But for
the initial (first time) connection setup, this setting must be enabled. User can
disable this setting for security reasons after initial connection setup is completed.
6.1.5 Update Settings
After all the desired settings are completed, the “Update” barcode must be scanned
to make the new settings effective. The scanner will re-start itself after “Update”
barcode is scanned.
6.2 HID Keyboard Interface
6.2.1 Keyboard Type
The HID keyboard interface is enabled by configuring/selecting keyboard type.
The supported keyboard types are listed below.
•PCAT - US, French German, Italian, Swedish, Norwegian, UK, Belgium,
Spanish, and Portuguese KBD
6.2.2 Keyboard Style - Alphabets
Keyboard layout style can be selected. There are three options to this setting:
default layout (US or English style), AZERTY layout, and QWERTZ layout. This
setting only works when the keyboard type selected is for US keyboard. The
scanner will make necessary adjustment when sending the ‘A’, ‘Q’, ‘W’, ‘Z’, ‘Y’,
and ‘M’ character according to this setting.
6.2.3 Keyboard Style – Digits
There are two digit layout styles as shown on the following figures. One has digit
on top (upper row) of a key and another has digits on bottom (lower row) of a key.
24
The digit layout style can be changed by the following configuration settings.
There are three options: Default, Lower Row, and Upper Row. The scanner will
make necessary adjustment when sending digits according to the setting value of
this parameter. This setting is used with the above setting (Keyboard Style –
Alphabets) and perhaps Character Substitution setting, when support to languages
not available on the scanner is needed.
6.2.4 Capital Lock Status
In order to send alphabets with correct case, the scanner needs to know the capital
lock status of the keyboard. Incorrect settings may result in reversed case of
alphabets being transmitted. There are 3 options to this parameter: On, Off, or Auto
Detection. If this parameter is set to Auto Detection, the scanner will automatically
detect the capital lock status of the keyboard before it transmits data.
6.2.5 Alphabets Transmission
User can choose how alphabets are sent by this parameter configuration. The
alphabets can be sent according to their case (the Case Sensitive option), or the
case is ignored (the Ignore Case option) when transmitting.
6.2.6 Digits Transmission
User can choose how the scanner transmits digits by configuring this parameter.
The scanner can transmit digits by using the alphanumeric key or by using the
numeric keypad. The Num Lock status of the keyboard should be ON if numeric
keypad option is selected.
! @ # $
1 2 3 4
Digits on Lower Row
1 2 3 4
! @ # $
Digits on Upper Row
Numeric Key Pad
Alpha Numeric Key

25
6.3 Configuring Bluetooth Device Driver
Please follow the procedures below to configure the Bluetooth driver on the host
system. Please note that, when searching nearby Bluetooth devices on Host
computers, the 1x66 scanner will come out with the serial number as their device
name. Please check the serial number label on the scanner when making
connections.
6.3.1 Windows XP with Service Pack2
1. Insert the Bluetooth dongle into PC host.
2. Double click the Bluetooth icon on the lower right of the taskbar.
3. Click Add button.
4. Check My device is set up and ready to be found and click Next button.
26
5. Select the 1x66 scanner and click Next button.
6. Select Let me choose my own passkey and input the passkey in the text field
and click Next button.
7. When the connection is ready, a message will be displayed : Found New
Hardware Bluetooth HID Device. Please click Finish button to complete the
connection.

27
8. The scanner is ready to use. Please click OK button.
6.3.2 Widcomm Bluetooth Driver
1. Click icon at PC.
2. Click Find Bluetooth Devices icon at My Bluetooth Places.
28
3. Right click the 1x66 scanner and select Pair Device.
4. Input PIN code and click OK button.
5. Right click 1x66 scanner and select Discover Available Services.

29
6. Click PC Remote Commander icon.
7. Click Yes Button.
8. When the green arrow icon is displayed, the connection is ready.
No
30
7. Symbology Parameters
This section describes user configurable parameters that are pertaining to barcode
symbologies.
7.1 Code39
•Standard / Full ASCII Code 39: User can choose to read either Standard
Code 39 or Full ASCII Code 39 by configuring this parameter.
•Start/Stop Transmission: This parameter specifies whether the start/stop
characters of Code 39 are included in the data being transmitted.
•Checksum Verification: This parameter specifies whether the scanner will
perform checksum verification when decoding barcodes. If the checksum is
incorrect, the barcode will not be read.
•Checksum Transmission: This parameter specifies whether the checksum
characters are included in the data being transmitted.
7.2 Italy / French Pharmacode
For Italy /French Pharmacode, there is always a checksum character included in the
barcode. So the checksum verification is always performed when decoding these
symbologies. User though can choose whether the checksum character is to be
transmitted or not. The start / stop transmission of this code shares the same setting
of Code 39.
•Checksum Transmission: This parameter specifies whether the checksum
character is included in the data being transmitted.
7.3 Industrial / Interleave / Matrix 25
•Start / Stop Selection: This parameter provides the readability of all 2 of 5
symbology variants. For example, flight tickets actually use an Industrial 25
barcode but with Interleave 25 start / stop. In order to read this barcode, the
start / stop selection parameter of Industrial 25 should set to ‘Interleave
25.
•Checksum Verification: This parameter specifies whether the scanner will
perform checksum verification when decoding barcodes. If the checksum is
incorrect, the barcode will not be read.

31
•Checksum Transmission: This parameter specifies whether the checksum
character is included in the data being transmitted.
•Code Length Qualification: Because of the weak structure of the 2 of 5
codes, a partial scan has a high probability of decoding as a valid but shorter
2 of 5 codes (known as short scan). To prevent this kind of undesired
reading, the Code Length settings can help to insure that the correct code is
read by qualifying the allowable code length. Code length parameters can be
configured in two ways: Fixed Code Length or Max / Min code length. If
the fixed code length is selected, up to 2 fixed lengths can be specified. And
if max / min code length is selected, the max length and the min length must
be specified, and the scanner will only accept those codes with lengths fall
between max / min length specified.
7.4 Codabar
•Start/Stop Transmission: This parameter specifies whether the start/stop
characters of Codabar are included in the data being transmitted.
•Start / Stop Selection: Four different start / stop pairs can be selected as
start / stop characters as listed below.
abcd / abcd
abcd / tn*e
ABCD / ABCD
ABCD / TN*E
7.5 UPCE
•System Number Selection: The UPCE comes with 2 formats: System
Number 0 and System Number 1. These two differ in the method of
encoding data. The system number 1 is the new UPCE extension to the
ordinary UPCE (system number 0). Users have the choice of enabling two
system numbers or just system number 0.
Warning: Because of the way system number 1 is encoded, if both system
numbers are enabled, user might suffer from short scanning UPCA or
EAN13 into UPCE system number 1 barcodes.
•Convert to UPCA: If this parameter is enabled, the UPCE read will be
expanded into UPCA, and the following processing will follow the
parameters configured for UPCA.
32
•System Number Transmission: If this parameter is enabled, the system
number will be included in the data being transmitted.
•Checksum Transmission: If this parameter is enabled, the checksum
character will be included in the data being transmitted.
7.6 EAN8
•Convert to EAN13: If this parameter is enabled, the EAN8 read will be
expanded into EAN13, and the following processing will follow the
parameters configured for EAN13.
•Checksum Transmission: If this parameter is enabled, the checksum
character will be included in the data being transmitted.
7.7 UPCA
•Convert to EAN13: If this parameter is enabled, the UPCA read will be
expanded into EAN13, and the following processing will follow the
parameters configured for EAN13.
•System Number Transmission: If this parameter is enabled, the system
number will be included in the data being transmitted.
•Checksum Transmission: If this parameter is enabled, the checksum
character will be included in the data being transmitted.
7.8 EAN13
•ISBN / ISSN Conversion: If these parameters are enabled, the scanner will
convert the code read into ISBN or ISSN code if the formats are correct
(EAN13 codes start with 978 or 979 for ISBN, and 977 for ISSN).
•Checksum Transmission: If this parameter is enabled, the checksum
character will be included in the data being transmitted.
7.9 MSI
•Checksum Verification: Three kinds of checksum calculations can be
implemented into MSI code: Single Modulo 10, Double Modulo 10, or

33
Modulo 11 & 10 checksum. If the checksum character is incorrect, the
barcode will not be read.
•Checksum Transmission: User can control the checksum transmit ion
format by configuring this parameter.
1) Transmitted
2) Last digit not transmitted
3) Last 2 digits not transmitted
•Code Length Qualification: Because of the weak structure of the MSI
code, a partial scan has a high probability of decoding as a valid but shorter
MSI codes (known as short scan). To prevent this kind of undesired
readings, the Code Length settings can help to ensure that the correct code
is read by qualifying the allowable code length. Code length limitations can
be set in 2 ways: Fixed Code Length and Max/Min code length. If the
fixed code length is selected, up to 2 fixed lengths can be specified. And if
max / min code length is selected, the max length and the min length must
be specified, and the scanner will only accept those codes with lengths fall
between max / min length specified.
7.10 Plessey
•Convert to UK Plessey: If this parameter is enabled, the scanner will
change each occurrence of the character ‘A’ into character ‘X’ in the code.
•Checksum Transmission: If this parameter is enabled, the checksum
characters (two characters) will be transmitted together with data.
7.11 Telepen
•Telepen Output: There are two flavors of encoding formats for Telepen.
One is the original Telepen format and another is AIM Telepen format. User
can choose the desired encoding format for Telepen readings.
7.12 RSS
•Code ID Selection: User has choice of using RSS Code ID (‘]e0’) or
EAN128 Code ID (‘]C1’).
•Code ID Transmission: If this parameter is enabled, the Code ID selected
by the preceding setting will be included in the data being transmitted.
34
•Application ID Transmission: If this parameter is enabled, the Application
ID will be included in the data being transmitted.
•Checksum Transmission: If this parameter is enabled, the checksum
character will be transmitted together with data.
Other manuals for 1166
2
This manual suits for next models
1
Table of contents
Other Syntech Information Scanner manuals