SyxthSense DAEA80 User manual

Product Sheet TH6.22
Thermostat Type DAEA80
Online Store: www.syxthsense.com
Enquiries: T: 0870 20 80 100 F: 0870 20 80 200 PS TH6.22 – 1/2
DAEA80 Active Antenna for Wireless
Thermostats
Model Types Model Description
DAEA80 DAEA80 Active Antenna for Wireless Thermostats
Technical Data Frequency 868.35 MHz
Modulation Type ASK
Antenna Type Self-Contained
Storage Temperature -10°C .. +50°C
Operating Temperature 0°C .. 40°C
Protection Class IP30
Humidity Limits 20% .. 80% rH (non condensing)
Enclosure Material: ABS V0 self-extinguishing
Colour Signal white (RAL 9003)
Agency Compliance EEC 89/336, 73/23, 93/68, 99/05
Size 85W x 85H x 31D mm
Weight 0.16kg
The DAE A83 is a high sensitivity and high selectivity receiving antenna
in wireless systems for temperature control in rooms or offices. Operating
on the LPD 868.35 MHz frequency it features all the advantages of this
band, such as freedom from interferences and higher radiating efficiency.
FEATURES
• High sensitivity and high selectivity internal radio receiver
• Self contained 868 MHz antenna
• Easy wiring to relay modules with pre-built data cables
• Compliant with directives EEC 89/336, 73/23 and 93/68, 99/05
SyxthSense Ltd
Online Store: www.syxthsense.com Copyright ©2004 SyxthSense Ltd – 07/2004
Enquiries: T: 0870 20 80 100 F: 0870 20 80 200 PS TH6.22 – 2/2
Mechanical Construction
In Fig. 1 is visible the external appearance of the DAE A83. To install the receiving unit it is
necessary to access to the internal parts. To open the plastic case, remove the frontal panel using a
small screwdriver to drive the plastic teeth (1) shown in Fig. 2. Apply a light pressure with the
screwdriver between the tooth and the hole in the plastics, but do not push directly on the tooth in
order not to break it.
The Fig. 2 represents also the plastic box section and shows how to
handle the screwdriver correctly.
In Fig. 3 is shown the receiver’s internal layout, and the location of
the ‘SIGNAL OUT’ plug (2).
Installation
Instructions Electrical installation is very easy, simply connect in the ‘SIGNAL OUT’ plug the proper data cable.
The data cable must then be connected to a relay module such as DLP 600 M or DLP 200 M. See
the relay module’s instruction sheet for more information. The best position where to install the DAE
A83 antenna should be decided taking into account the following:
1) The antenna has been designed to fit in a small case to be easily installable in the best location
for the radio signals to be received. Often the relay module’s place is not a good place for the
antenna too. The worst case is when the relay module is mounted inside a metal frame: the antenna
must be definitely be placed outside the metal frame.
2) Since the radio signal are strongly attenuated by metal screens, the antenna should be placed as
far as possible from metal grids and objects.
3) Care must be taken also at the wall, which the antenna will be fixed on. It must not be a metallic
wall or have a metallic frame inside.
4) Radio signals inside a building are reflected by walls, floors, furniture and other objects, it might
happen that some room’s areas are bad for the signal reception, and some others might be good.
Moving the antenna half a meter often determines a considerable different receiving performance.
Once the antenna’s position is chosen, the system should be tested, to ensure that all the thermostat
transmitters’ signals are correctly received. See the thermostat’s documentation how to do that.
After the system has been successfully tested proceed with the definitive installation of the DAE A83
by fixing it on the wall with two screws, using the holes with distance between axes of 60 mm visible
in Fig. 3 (3). While working with tools in the screw holes, be careful not to damage the internal
circuits or any other component. Once the installation has been completed, close the plastic case by
carefully positioning the front panel, then slightly press the panel in order to make the four plastic
teeth snapping.
WARNING !
- To determine the correct position ensure that the radio signals transmitted are correctly
received by the receiving unit.
- Installation and electrical wirings of this appliance must be made by qualified technicians
and in compliance with the current standards.
- Before wiring the appliance be sure to turn the mains power off.
Notes: In the view of a constant development of their products,
the manufacturer reserves the right for changing technical data
and features without prior notice. The consumer is guaranteed
against any lack of conformity for 24 months from the time of
delivery, according to the European Directive 1999/44/EC. The
full text of
g
uarantee is available on re
q
uest from the seller.

Other SyxthSense Thermostat manuals

SyxthSense TAE-DI4 User manual

SyxthSense

SyxthSense TAE-DI4 User manual

SyxthSense Tempora TCP-GIO-BI03 User manual

SyxthSense

SyxthSense Tempora TCP-GIO-BI03 User manual

SyxthSense NEW WAVE DTP Series User manual

SyxthSense

SyxthSense NEW WAVE DTP Series User manual

SyxthSense SST-A24-302 User manual

SyxthSense

SyxthSense SST-A24-302 User manual

SyxthSense DCPA80BC User manual

SyxthSense

SyxthSense DCPA80BC User manual

SyxthSense DTP-A80-BC Dimensions

SyxthSense

SyxthSense DTP-A80-BC Dimensions

Popular Thermostat manuals by other brands

Vaillant geoTHERM SERIES Instructions for use

Vaillant

Vaillant geoTHERM SERIES Instructions for use

Braeburn Economy Series Installer manual

Braeburn

Braeburn Economy Series Installer manual

Honeywell CT50 owner's manual

Honeywell

Honeywell CT50 owner's manual

Heatit ZM 16A Installer manual

Heatit

Heatit ZM 16A Installer manual

Julabo F12-MC Quick setup guide

Julabo

Julabo F12-MC Quick setup guide

Solaris TER1 quick start guide

Solaris

Solaris TER1 quick start guide

Radio Thermostat CT30 Operation guide

Radio Thermostat

Radio Thermostat CT30 Operation guide

Stelpro STE402P user guide

Stelpro

Stelpro STE402P user guide

Venstar T2700 installation instructions

Venstar

Venstar T2700 installation instructions

York LX series owner's manual

York

York LX series owner's manual

White Rodgers 1A11-2 installation instructions

White Rodgers

White Rodgers 1A11-2 installation instructions

Peco TF115P-002 installation guide

Peco

Peco TF115P-002 installation guide

Centralite Pearl Thermostat Product data sheet

Centralite

Centralite Pearl Thermostat Product data sheet

INSBUD IB-Therm 201 manual

INSBUD

INSBUD IB-Therm 201 manual

EBECO EB-Therm 350 manual

EBECO

EBECO EB-Therm 350 manual

Braeburn 5970 user manual

Braeburn

Braeburn 5970 user manual

Theben RAMSES BLE OT 8509150 manual

Theben

Theben RAMSES BLE OT 8509150 manual

SmartDHOME MyVirtuoso Home Zone Thermostat user manual

SmartDHOME

SmartDHOME MyVirtuoso Home Zone Thermostat user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.