SZBJ BM852A+ User manual

BM852A+ ENGLISH INSTRUCTION MANUAL
1. Introduction
Welcome to choose this product!
This is a kind of 31/2 bit portable digital Clamp-Shape meter, which may
measure AC current and AC & DC voltage, resistance, test for connection and
disconnection, positive voltage on diode, temperature, frequency, phase
sequence etc.. The meter is the ideal tool of the industries of electricity,
electronics and refrigeration due to wonderful structure, easily operated, more
portable.
2. Safety
The meter is designed in accordance with the safety requirements of the
standard IEC1010-1. Please
Carefully read this manual before operate it.
2.1 Note for safety symbols:
Warning hint, Caution!
Danger by high-voltage shock!
Double insulation protection
2.2 During measuring, any range may not exceed its input value in Max
2.3 At resistance range, not allowed to impose voltage on input
2.4 During measuring, to prevent the meter from damage, do not turn its round
switch to change its range.
2.5 Over DC60V or AC30V may be shock danger, carefully operating during
measuring.
2.6 During clamping non-insulation wire, must specially be careful to avoid
2.7 During measuring current, fingers must be placed on the back of the
armguard of the meter.
2.8 The meter shall avoid straight sunlight, high temperature and humidity.
2.9 After measuring end, the turning switch shall be at OFF.
2.10 Idling for long term, its batteries shall be taken out to prevent the batteries
from leaking liquid to damage parts.
3. Features
3.1 Displaying mode: LCD displayer
3.2 Maximum display: 1999
3.3 Maximum open: 30mm
3.4 Automatic negative indication: Displaying “-“
3.5 Low battery indication: Displaying “ ”
3.6 Operating environment: 0C~40C,70%RH(Max.)
3.7 Storage environment: -10C~60C,85%RH(Max.)
3.8 Power supply: 9V battery (IEC6F22, NEDA1604, JIS006P or equivalent
types),
3.11 Size 221(Length)75(Width)31(Height)mm
3.12 Weight: about 240gram(with batteries)
4. Usage of Clamp-Shape Meter with Manual Range
4.1 Instruction on operating panel (see figure)
(1) Clamp mouth
(2) Trigger
(3) Range switch: choosing current, voltage, resistance, frequency,
forward voltage on diode, test for connection and disconnection and
range.
(4) DH reading holding button: pressing the button may lock the current
reading, and displaying “DH” symbol, repressing the button to
cancel the holding function, “DH” symbol disappears.
Phase sequence: At range AC600V, “DH” button is the switch to measure
phase sequence, pressing the button to display “ “symbol for measuring
phase sequence, repressing the button to cancel the function, “ “symbol
disappears.
(5) LCD
(6)” COM” for common input ( input ground)
(7)“V/”voltage-resistance-frequency-temperature input jack
(8) Armguard
4.2 Measurement of AC voltage
Turn the range switch into the range “A600V”, Plug the black pen into the
jack“COM”,the red pen into the jack“V/”,in parallel connect the pens with
the measured circuit,read the displaying number.
4.3 Measurement of DC voltage
Turn the range switch into the range “D600V”, Plug the black pen into the
jack“COM”,the red pen into the jack“V/”,in parallel connect the pens with
the measured circuit,read the displaying number. When the reading is less
than 20V, turn the range switch at range ”DC20V” to measure again.
4.4 Measurement of AC current
Turn the range switch into the range “AC600A”, clamp the wire of the
measured current, shall put the wire into the canter of the completely closing
clamp mouth as soon as possible, directly get the reading. When the reading is
less, turn the range switch at lower range to measure again.
Cautions:If two or more than two different wires are clamped, the
measuring can’t be done.
4.5 Measurement of resistor and connection & disconnection
(1) Turn the range switch into the range 2k
(2) plug the black pen into the jack“COM”,the red pen into the jack“V/”
(3) In parallel connect the pens into the two terminators of the measured
circuit or component,get the reading.
(4) when the two pens open or input overload,the displayer shows “1”
4.7 Measurement of forward voltage of diode
(1) Turn the range switch into the range ,when the input opens, the
meter shows over range(show“1”)。
(2) Plug the black pen into the jack“COM”,the red pen into the jack“V/”,
(the red pen’s polarity is“+”)
(3) In parallel connect the pens into the two terminators of the measured
diode,get the reading for approximation of the forward voltage.
(4) when the diode is connected in reverse or the input open,the displayer
shall show “1”.
4.8 Test of connection and disconnection
(1)Turn the range switch into the range ,when the input opens, the
meter shall show over range(show “1”)。
(2)Plug the black pen into the jack“COM”,the red into the jack“V/”。
(3)In parallel connect the two pens into the two terminators of the measured
circuit,if the resistance between the tested two points is less than approximate
50,the buzzer shall make a sound.
Cautions: resistor, diode and connection and disconnection sharing the
same range, when measuring, the measured component or circuit cannot be
electrified, otherwise, shall misjudge.
4.8 Test of connection and disconnection
(1)Turn the range switch into the range ,when the input opens, the
meter shall show over range(show “1”)。
(2)Plug the black pen into the jack“COM”,the red into the jack“V/”。
(3)In parallel connect the two pens into the two terminators of the measured
circuit,if the resistance between the tested two points is less than approximate
50,the buzzer shall make a sound.
Cautions: resistor, diode and connection and disconnection sharing the
same range, when measuring, the measured component or circuit cannot be
electrified, otherwise, shall misjudge.
4.9 Measurement of temperature
Turn the range switch into the range ℃, put the black plug of K type
thermoelectric couple attached with the meter into the jack“COM”, the red into
the jack“V/”, here the meter shall show environmental temperature, place the
detector head on the measured object, get the reading when the detector head
and the measured object are the same temperature.

Cautions:
When the temperature detector head not put into the meter, the displaying
value is meaningless, attached with the meter, the limited temperature of the
conjunction thermoelectric couple , which is the K type WRNM-010, bareness
style, is 250℃( may reach 300℃ in short time)。
4.10 Measurement of frequency
Turn the range switch into the range 2kHz, put the black pen into the jack
“COM”, the red into the jack“V/”, in parallel connect the two pens into the
measured circuit, get the reading.
4.11 Measurement of phase sequence
Turn the range switch into the range AC600V, put the black pen into the
jack“COM”, the red into the jack “V/”, take a press on the button for
measurement of phase sequence, LCD shall display symbol“ ”,for
measuring phase sequence, after a measure to phase sequence, if measuring
again, it is necessary to press the button for phase sequence to cancel the
function on measurement of phase sequence at first, then restart the function
on measurement of phase sequence, the meter sets its phase sequence as
A B C.
4.11.1 Measurement of three-phase four-wire system:
(1) Confirm phase A: connect the black pen into the zero wire or the
ground wire, the red pen into any hot wire, LCD shall show the
symbol A, here the phase connected with the red pen is defined as
phase A.
(2) Find phase B or phase C: connect the black pen into the zero wire or
the ground wire, the red into any hot wire of the other hot wires, when
LCD shows the symbol B, the phase connected with the red pen is
defined as phase B,when LCD shows the symbol C, the phase
connected with the red pen is defined as phase C
(3) During measuring, the meter may show the value of the line voltage
of the measured phase:
(a) When the measured line voltage is less than 30% of the other
phases, then the phase is lost;
(b) When either phase B or phase C cannot be found, then either phase
B or phase C is lost.
4.11.2 Measurement of three-phase three-wire system:
(1) Confirm phase A: connect the black pen into any wire, the red pen into
any wire of the other, LCD shall show the symbol A, here the phase
connected with the black pen is defined as phase A.
(2) Find phase B or phase C:
(a) Keep the black on the original phase, connect the red into the third
phase, when LCD showing B, here the phase connected with the red
is phase B, may judge the phase connected with the red in step (1) is
phase C.
(b) When LCD showing C, here the phase connected with the red is
phase C, may judge the phase connected with the red in step (1) is
phase B.
(3) During measuring to step (1)、(2), the meter shall show line voltage
(380V). If the voltage of a phase is less than 30% of the others, then
the phase of the lower voltage is lost, after phase A is confirmed, either
phase B or phase C cannot be found, then either phase B or phase C is
lost.
Cautions :please reset before each measurement(quit the function
on the measurement of phase sequence, then restart the function)
measuring period may not more than 10 seconds.
5. Technological Indices
Accuracy guarantee: 1 year,Temperature of keeping accuracy:23℃±5℃
Relative humidity:<75 %。
Function Range Resolution Accuracy
20A 10mA
ACA 600A 1A
1.9%5
ACV 600V 1V 1.2%5d
20V 0.01V
DCV 600V 1V 0.8%2d
Resistor 2k 1 1.0%2d
FREQ 2kHz 1Hz 2.0%5d
ACA frequency range :50~60Hz( sine wave),ACV frequency range:
50~100Hz(sine wave)。
Function Range Resolution Accuracy
-30~400℃ 1℃ 1.2%4d
Temperature 400~1000℃ 1℃ 1.9%15d
Diode
Show the value of the forward voltage. Test conditions:
forward DC current is about 1mA,backward DC voltage
is about3V。
Connection &
disconnection
When Conductive resistance is less than about 50, the
buzzer in the meter sounds, test conditions:open voltage
is about 3V。
Phase
sequence
May measure the phase sequence of AC when phase
tolerance is under ±25
Resistor,Diode;Buzzer,FREQ Overload Protection :250V
6. Maintenance of the Meter
Cautions!Before open the covers of the meter, or the batteries, shall
switch off power and disconnect the pens and any input signal to prevent
danger of shock.
6.1 when the meter shows symbol“ ”, shall change battery. Open the
battery cover, change a fresh battery with 9V ( Automatic range meter:Two
new batteries with AAA1.5V ), to make sure the meter normal work.
6.2 Keep the meter and the pens clean, dry and non-damage, may clean the
meter surface with clean clothes or eradicator, abrasive or organic solvent is
banned.
6.3 Avoid mechanical damage, shake, impact, keep the meter away from high
temperature and strong magnet field.
6.4 The meter shall be calibrated once a year.
7. Accessories
7.1 A pair of pen
7.2 A manual
7.3 K type detector head for temperature
Other SZBJ Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

SRM
SRM High Performance Ergometer manual

OPTOKON
OPTOKON PM-212 instruction manual

Kofloc
Kofloc 3760 Series instruction manual

HP
HP 3455A Operating and service manual

Endress+Hauser
Endress+Hauser Tankvision Multi Scan NXA83B operating instructions

Cardinal
Cardinal 200 Installation, Technical and Operation Manual