General:
The 5 wires encoder unit is an intercom system, serves as door
panel and encoder.
With this unit you can speak with the visitor who is waiting at
the door and open the electric lock from the intercom handset or
from the phone using Tador 5 wires adapter.
Authorized personnel can open the door y pressing
An access code.
By programming appropriately, each user can get an
individual access code.
The device includes an environment resistant and anti
vandal metal key oard.
An optional ypass push utton ena les easy internal
opening (the opening time is programma le)
Features:
Easy installation, programming and
operating.
Power failure resistance, keeps the access
codes in nonvolatile memory
up to 98 simultaneously different access
codes
Environmental and anti vandal resistance.
Different and programma le opening time
from key oard and ypass push utton
Up to 1 million possi le com ination codes
optional ypass exit push utton
Specifications:
Operating voltage: AC 12V 800mA Code length: 2-6 keys
Operating electric or magnetic lock. (normally
open or normally close)
Opening time: 1-9 seconds
Color: silver or ronze Size: under plaster195X115X50mm (H*W*D)
On the wall 154X100X35mm (H*W*D)
Installation:
J5 should e set accordingly to the door lock type (3 pins jumper)
Desirable RLY state when entering alid code
Jumper J5
Close circuit (Normally open) for electric lock Jumper on 2 left pins (default state)
Open circuit (Normally close) for magnetic lock Jumper on 2 right pins
After installing the lock in the door frame. Route the following wires to the Intercom Encoder:
1. 2 wires from power supply.
2. 2 wires from the lock.
3. 5 wires from Intercom handset.
4. 2 wires from optional ypass push utton.
Using a Phillips screwdriver open the top cover, carefully pull up the panel.
Using a screw driver, expose the 4 covered insulations ores and the round wirings ore.
Attach the ase of the Intercom Encoder to the wall, using a pencil mark the 4 fixing points.
Drill the 4 fixing points on the wall.
Route the wires through the round ore in the ase of the Intercom Encoder.
Using 4 screws install the ase to the wall.
Verify the power supply is not connected to power source!
Connect the wires to the circuit oard terminal locks according to the circuit’s la els, the
attached electrical diagram and the following instructions.
Connect: Power supply to the two 12VAC terminals.
One wire from the lock to the RLY terminal. The second wire from the lock to one of the
12VAC terminal. Short wire from the second 12VAC terminal to the second RLY terminal.
(The RLY functions as a switch)
Surface
Mount
Flush
/Surface
Mount

Tador Technologies CD-500 Installation guide
2
Handset wiring
Several common handsets could e assem led.
Electric buzzer handset can not be assembled.
Wiring of different handsets is detailed in the electrical drawing in page 4 and the following
ta le:
Encoder
terminal
Amply ox
handset
Videx
handset
Videx handset
SMART 1P
URMET wire
Left pin 12VA-C 0 3 3 / 7 6 COM
RX Z 5 5 9 lock
SW 1 6 6
Second uzzer
connection
uzzer
MC T 1 1 1 speaker
SP R 2 2 2 microphone
If you intend to install a ypass push utton, connect one wire to RX terminal and the other
wire to the 12VAC terminal which the handset com wire is connected to.
Reassem le the panel over the ase.
Attach the top cover to the ase using the 4 screws.
Connect the power supply to the power inlet, the red led will illuminate, indicating power
supply to the Intercom Encoder. The green led will link for 2 seconds indicating correctly
initiation.
Programming:
100 memory cells 8 digits long each one, availa le.
Cell 00 is used for door opening times values storage.
Cell 99 is used for programming code value storage.
The rest of the 98 cells from 01 to cell 98 are used for different access codes values storage.
The code length is minimum 2 digits and ,maximum 8 digits. (recommended 6 digits for
programming code, and 4 digits for access code)
Programming code, access codes and opening times values are programma le via the
key oard.
Programming mode: in order to store new access code, set opening times or changing the
programming code, you should enter to the Programming mode.
After clicking the valid programming code (manufacturer code if not changed is ⇒123456
confirm with*) the green led is linking, now you can do the required programming as
descri ed in the following examples. When finished you can enter more access codes or exit
this mode to the regular state y pressing
֠
֠֠
֠
.
Each key stroke is followed y a Beep sound, entering a false code or invalid pressing is
followed y a “Beep-Beep-Beep” sound sequence. Entering a valid sequence to memory cell is
followed y a long “Beep” sound.
If the programming mode is not exit. A timer exits the Intercom Encoder from this mode to a
regular mode.
Examples:
Storing a new access code
Enter the programming code: if not changed is: 123456 confirm with *, the green led will
link.
now the following sequence should e entered: memory cell num er (2 digits), access code
(2-6 digits),and for verification again the same memory cell num er, the same access code.
Confirm with *. To finish press:
֠
֠֠
֠
.
You can add more access codes in cells 01-98 in the same way.
-to use the access code: press the access code followed y *.
For example storing the code 9124 in cell num er:01.
Press: 123456 *, 01 then 9124 and again 01 and 9124 confirm with *.
To finish press:
֠
֠֠
֠
.

Tador Technologies CD-500 Installation guide
3
Changing the programming code
Enter the programming code: if not changed is: 123456 confirm with *, the green led will
link.
now the following sequence should e entered: memory cell num er 99 , new programming
code ,and for verification again the memory cell num er 99, the same new programming
code. Confirm with *.
Now you can add access codes in cells 01-98 as descri ed or exit.
To finish press:
֠
֠֠
֠
.
For example changing the programming code to: 649731.
Press: 123456 *, 99 then 649731
and again 99 and 649731 confirm with *.
To finish press:
֠
֠֠
֠
.
You should keep this code because this is the only way to enter the programming
mode!
Back to Initiate status – default
Using an internal jumper the initial programming code can e restored. The access codes will
not e changed.
Turn the power off. dismount the panel. Install a jumper on pins la eled: DEFAULT turn on
the power, a long “Beep” will e sound for confirmation.
Turn off the power and take out the jumper. Reinstall the panel.
The Intercom Encoder returns to normal condition. The Programming code now is: 123456 *.
Canceling an access code
A particular access code could e cancel if its memory cell location is known.
Enter the programming code: if not changed is: 123456 *, the green led will link.
now the following sequence should e entered: memory cell num er to cancel(2 digits), and
֠
֠֠
֠
֠
֠֠
֠
.for verification again the same memory cell num er, and
֠
֠֠
֠ ֠
֠֠
֠
. Confirm with *.
For example: canceling the code stored in cell num er 37:
press the following sequence: ⇒123456 *, 37
֠
֠֠
֠ ֠
֠֠
֠
37,
֠
֠֠
֠ ֠
֠֠
֠
*.
To finish press:
֠
֠֠
֠
.
Setting opening times alues
A different opening time value can e set to opening via the key oard and via the optional
ypass push utton.
The times values are from 1 second till 9 seconds.
Enter the programming code: if not changed is: 123456 *, the green led will link.
now the following sequence should e entered: memory cell num er 00, opening time via
key oard (1 digit) followed y opening time via ypass push utton (1 digit). for verification
repeat the same sequence of memory cell num er 00 opening times values. Confirm with *.
To finish press:
֠
֠֠
֠
.
Remark: when setting the key oard opening time, a value to the ypass push utton must e
set also, even if not installed.
For example setting the key oard opening time to 5 sec. And push utton to 7 sec.
Press: 123456 *,00 then 5 then 7
and again 00 and 5 and 7 confirm with *. To finish
press:
֠
֠֠
֠
.
Summery and examples
Programming option execution default
Entering programming code ⇒ 123456 *
Changing programming code
For example: new code 777456
Enter programming code, *
⇒ 99-777456 99-777456 *
֠
֠֠
֠
123456
Storing a new access code
For example: cell num er 01
access code: 2040
Enter programming code, *
⇒ 01-2040 01-2040 *
֠
֠֠
֠
All the cells are empty
(not 0)
Canceling access code stored in
cell num er 37
Enter programming code, *
⇒ 37-
֠
֠֠
֠ ֠
֠֠
֠
37-
֠
֠֠
֠ ֠
֠֠
֠
*
֠
֠֠
֠
Setting opening time from
key oard to 2 seconds and from
ypass push utton to 5 seconds
Enter programming code, *
⇒ 00-25 00-25 *
֠
֠֠
֠
3 seconds from
key oard,
3 seconds from ypass
push utton

Tador Technologies CD-500 Installation guide
4
Microphone and speaker olume adjustments
The Intercom Encoder unit leaves the manufacturer site adjusted.
Sometimes ecause of the location (opened or closed space), acoustical pro lems occur.
If the Encoder’s speaker sound level is too high or low, gently rotate the internal SP
potentiometer.(clockwise to lower volume)
If the sound level of the Encoder in the handset is too high or low, gently rotate the internal
MIC potentiometer. (clockwise to lower volume)
Operation
Calling at the door
Press shortly on the Bell
֠
֠֠
֠.
Wait for vocal answer. If authorized, the lock will uzz and you
may enter.
Opening the lock using the keyboard
Enter the access code confirm with *.
The lock will e open for the time value it was programmed.
Each key stroke is followed y a Beep sound, entering a false code or invalid pressing is
followed y a “Beep-Beep-Beep” sound sequence.
When exit the secured area press the ypass push utton, the lock will e open for the
programmed time value (could e set to different value than entering).

Tador Technologies CD-500 Installation guide
5
Intercom Encoder Electrical drawing
Lock
Speaker volume
adjustment
Microphone
volume
adjustment
12VAC C DOORCOM SW MIC SPK
PHONE LINE
POWER
LED1 LED2
JP2
JP3
5-Wires Adaptor
RX SW MC SP12VAC
ממסר
INTERCOM-CODE
RLY
DEFAULT
MIC
SP
MIC
SP
J5
ממסר
Line In
Open - C and Door
open contact
Close (Default) -
Com and C
connected
for electric lock
Power
Suppl
12V AC
12 VAC
To avoid
noises COM
and power
supply must
e connected
separately
and directly
to this point
PRG
Normally
open electric
lock
Normally
close
magnetic lock
Comelit
handset
Amplyvox
handset
Videx Smart
1P handset
T
R
1
0
Z
1
2
3
5
6
4
P1
3
2
The second
uzzer
connection
3/7
5
6
1
2
Videx
handset
COM
Lock
Buzzer
SP
MIC
Line
coming in
Routing ADSL line
ADSL
splitter
Connect
directly to
the PC
Line in
adapter
PC
Without jumper
=
using telephone line
With jumper
=
intercom without
telephone line
Octo er 2005