FAQ:
1. Is it possible to connect system to large distance 400 ft?
Possible, but need to make sure below details during installation:
1. Good cable referred twisted cable 2 x 1 mm
2. PC6A should be nearest as ossible to the monitor inside the house.
3. Just to make sure, monitor need to get 24V, so if you can connected and check the ower that arrives to the
monitor is 24V it should be working
this is why good cable is very im ortant.
1. Bus from Monitor goes to PC6A
2. Bus from PC6A goes to the anel Bus
3. Relay : connects to electric lock in your situation you can connect it directly to gate command to o en
the gate
4. Rex : if want to install by ass button to o en the door by ressing a button
2. Unit doesn’t show Picture Audio?
It may be a roblem with infrastructure check below:
Disconnect the unit and connect again in a short distance between the monitor, anel and PC6A
if unit show icture, there might be a roblem with wires quality or distance.
+ Try to im rove the cable quality
+ Try Reduce distance between PC6A and Monitor.