Tamarack Industries Heat King HK300B User manual

HK300B
Operation Manual
Part # 200103
Date # July 2019

2
As a new customer of Heat King we would like to welcome you! We are looking
forward to providing you with technical support for your Heat King unit. Whatever you
need we are here to help.
Ways to contact us for support
By Phone : 1-800-661-0304
The main Technical support phone line is staffed monday-friday 7:00 AM to 3:30
PM CST excluding Manitoba statuatory holidays.
After hours support
Calls received outside of regular hours are directed to the On-call technician. Af-
ter hours support is reserved for issues that cannot wait until the next business day
for resolution. If no answer please leave a message and we will get back to you as
soon as possible.
Feel free to email us at any time with technical questions or parts inquiries.
Please include the year make and model of your Heat King if you have a specic
question about your machine so we can better help you. If it is an emergency please
call 1-800-661-0304
For more information please visit our website
www.heat-king.ca

3
WARNING
CALIFORNIA - Proposition 65 Warning
Engine exhaust and some of its constituents and some dust
created by power sanding, sawing, grinding, drilling and
other construction activities contains chemicals known to the
State of California to cause cancer, birth defects and other
reproductive harm.
Some examples of these chemicals are:-
Lead from lead-based paints
Crystalline silica from bricks
Cement and other masonry products
Arsenic and chromium from chemically
treated lumber
Your risk from these exposures varies, depending on how
often you do this type of work. To reduce your exposure to
these chemicals:
ALWAYS work in a well ventilated area, and work with
approved safety equipment, such as dust masks that are
specially designed to lter out microscopic particles.

4
Table of contents
Title Pages
Ways to contact us 2
Warning 3
Safety 5-11
Introduction 12
Training sign off 13
Vin Number Location 14
Warranty 15-16
How it works 17
Protective devices 18
Controls 19-23
Set up 24-25
Operating procedures 26
Maintenance 27-36
Service parts 37
Troubleshooting 38-39
Lifting instructions 40-41
Specications 42
MSDS 43-52
Schematics 53-55

5
Accidents Disable and Kill
Accidents Cost
Accidents Can Be Avoided
Why is SAFETY important to you?
3 Big Reasons
ous situation that, if not avoided, will
result in death or serious injury. This
signal word is to be limited to the most
extreme situations, typically for ma-
chine components that, for functional
purposes, cannot be guarded.
Indicates a potentially hazardous situa-
tion that, if not avoided, could result in
death or serious injury, and includes
hazards that are exposed when guards
are removed. It may also be used to
alert against unsafe practices.
Indicates a potentially hazardous situa-
tion that, if not avoided, may result in
minor or moderate injury. It may also
be used to alert against unsafe prac-
tices.
SIGNAL WORDS:
Note the use of the signal words DANGER,
The Safety Alert symbol identies
important safety messages on the
Tamarack Heat King and in the
manual. When you see this symbol,
be alert to the possibility of personal
injury or death. Follow the instruc-
tions in the safety message.
This Safety Alert symbol means
ATTENTION! BECOME ALERT!
YOUR SAFETY IS INVOLVED!
WARNING and CAUTION with the safety
messages. The appropriate signal word for
each message has been selected using the
following guide-lines:
SAFETY
SAFETY ALERT SYMBOL
DANGER - Indicates an imminently hazard-
WARNING -
CAUTION -

6
Safety, Installation & Operation
SAFETY
YOU are responsible for the SAFE operation and
maintenance of your Tamarack Industries Heat
King. YOU must ensure that you and anyone else
who is going to operate, maintain or work around
the Heat King be familiar with the operating and
maintenance procedures and related SAFETY
information contained in this manual. This manual
will take you step-by-step through your working
day and alerts you to all good safety practices that
should be adhered to while operating the Heater.
Remember, YOU are the key to safety. Good
safety practices not only protect you but also
the people around you. Make these practices a
working part of your safety program. Be certain
that EVERYONE operating this equipment is
familiar with the recommended operating and
maintenance procedures and follows all the safety
precautions. Most accidents can be prevented.
Do not risk injury or death by ignoring good safety
practices.
• Heater owners must give operating instruc-
tions to operators or employees before allow-
ing them to operate the machine, and at least
annually thereafter.
• The most important safety device on this
equipment is a SAFE operator. It is the opera-
tor’s responsibility to read and understand
ALL Safety and Operating instructions in the
manual and to follow these. Most accidents
can be avoided.
• A person who has not read and understood
all operating and safety instructions is not
qualied to operate the machine. An untrained
operator exposes himself and bystanders to
possible serious injury or death.
• Do not modify the equipment in any way.
Unauthorized modication may impair the
function and/or safety and could affect the life
of the equipment.
• Think SAFETY! Work SAFELY!
GENERAL SAFETY
Only trained competent persons shall operate
the Heater. An untrained operator is not qualied
to operate the machine.
Have a rst-aid kit available for
use, should the need arise and
know how to use it.
Do not allow riders.
Have a re extinguisher available for use
should the need arise and know how to
use it.
Wear appropriate protective gear. This
list includes, but is not
limited to:
- A hard hat
- Protective boots with
slip resistant soles
- Protective goggles
- Heavy gloves
- Hearing protection
Place all controls in their OFF position,
disconnect power cords and wait for all moving
parts to stop before servicing, adjusting or
maintaining
Wear appropriate hearing protection
when operating for long periods of
time.
Wear protective gloves
Ventilation ~ Never operate in a poorly
ventilated or enclose area. Avoid
prolonged breathing of exhaust
gases.
2.
3.
4.
5.
6.
7.
8.
9.
10.
1. Read and understand the
Operator's manual and all
safety signs before
operating, maintaining,
adjusting, servicing or
cleaning the Heater.

7
ELECTRICAL SAFETY
1. Place all controls in their OFF position, discon-
nect power cords and wait for all moving parts to
stop before servicing, adjusting or maintaining.
2. Place all controls in their OFF position before
plugging in power cords.
3. Keep all electrical components in good repair
before starting.
4. Do not lay power lines or connectors in water
or on a wet surface. Dry connectors and raise
power lines out of the water before and during
operation.
5. Do not operate machine if there are electrical
malfunctions. Correct problem before resuming
work.
11. Hot surface ~ Avoid contact with
hot exhaust and glycol system.
Allow to cool before performing repairs
or service.
12. Electrocution Hazard ~ Always use proper size
grounded extension cord. Inspect all extension
cords for cuts, frayed wires and broken connectors.
Do not use cords if not in good condition.
13. Fire Hazard ~ Do not operate
machine in the vicinity of open
ames, sparks or while
smoking.
14. Explosion Hazard ~ Battery
Take care when handling battery
(if installed)
TIRE SAFETY
1. Failure to follow proper procedures when
mounting a tire on a wheel or rim can produce
an explosion which may result in serious injury
or death.
2. Do not attempt to mount a tire unless you have
the proper equipment and experience to do the
job.
3. Have a qualied tire dealer or repair service
perform required tire maintenance.
4. Torque wheel nuts to 120 ft-lbs
STORAGE SAFETY
1. Store unit in an area away from human
activity.
2. Do not permit children to play on or around the
stored Heater.
FUEL SAFETY
Danger: To avoid possible injury, re, or explo-
sion, please read and follow these instruc-
tions.
1. Handle fuel with care. It is highly ammable.
2. Allow burners to cool for 5 minutes before
refueling. Clean up spilled fuel before restarting
engine.
3. Do not refuel the machine while smoking or
when near open ame or sparks.
4. Always use an approved fuel container.
5. Fill fuel tank outdoors.
6. Prevent res by keeping machine clean of ac
cumulated trash, grease and debris.

8
BEFORE INSTALLATION
1.LOCATION: This machine should be installed by only
qualied technicians. The machine should be set
upon a level surface, minimizing the effect of winds,
rain and snow. Install the machine considering loca-
tions for fuel connections, electrical connections,
venting, and maintenance. All wiring and electrical
connections should comply with the National Electri-
cal Code (NEC) and with localcodes and practices.
2.GAS AND ELECTRICITY: Gas and electricity must be
shut off when installing or servicing.
3.LOCAL CODES: Installation and servicing must only be
performed by qualied personnel and must conform
to local codes.
4.FIRE HAZARD: Keep combustible materials away from
the machine. DO NOT allow lint or dust to collect in
the burner area.
5. QUALIFIED PERSONNEL: All installation andservic-
ing must only be performed by qualiedpersonnel and
must conform to the local codes.
INSTALLATION SAFETY
1. Use only fuel for the heater burner specied in the
specications section of this manual. The use of incorrect
fuel may result in re or explosion and sever injury to the
operator.
2. Fuel burning equipment must have proper ventilation
for cooling, combustion air, and exhausting of combustion
products
3. Personnel trained in and familiar with the type of equip-
ment being serviced should only perform adjustments to
fuel burning equipment.
WARNING: This machine emits carbon mon-
oxide, a deadly gas, and must be vented if
used in an enclosed area. Improper venting
can cause poor combustion, delayed igni-
tion, down drafts and possibility of freezing
of the coil.
The information contained herein is offered for reference
only. You must comply with local codes and investigate
through your local gas or utility companies when install-
ing, as there may be some local requirements you must
comply with. Also see ANSI Z223.1
Never reduce the stack size, the diverter and stacking
should be the same size as the stack opening on the
machine

9
MAINTENANCE SAFETY
1. Review the Operator's Manual and all safety
items before working with, maintaining or
operating the Heater.
2. Place all controls in their OFF position, dis-
connect power cords and wait for all moving
parts to stop before servicing, adjusting or
maintaining.
3. Follow good shop practices:
4. Keep hands, feet, clothing and hair away from
all moving and/or rotating parts.
5. Always wear heavy gloves to prevent burns
when handling hot components. Wait until burn-
ers, coils and glycol system components have
cooled before working on them.
6. Do not attempt any adjustment or maintenance
to any system of the Heater unless the power
wires are disconnected from the battery.
7. Make sure that all guards, shields and hoods
are properly installed and secured before oper-
ating the Heater.
8. Securely support the machine using blocks
or safety stands before working beneath it or
changing tires.
9. Store and transfer diesel fuel, solvents, cleaners
or any ammable liquids only in safety standard
approved containers.
- Keep service
area clean and dry.
- Be sure electri-
cal outlets and tools
are properly ground-
ed.
- Use adequate
light for the job at
hand.
OPERATING SAFETY
1. Read and understand the Operator’s Manual
and all safety signs before operating, servic-
ing, maintaining or adjusting the Heater.
2. Place all controls in their OFF position,
disconnect power cords and wait for all
moving parts to stop before servicing,
adjusting or maintaining.
3. Do not allow riders in or on machine during
transport.
4. Clear the area of bystanders, especially small
children, before starting and operating.
5. Keep the working area clean and free of de-
bris to prevent slipping or tripping. Clean up
fuel spills immediately if they occur.
6. Slow down. Use care when working around
unit - the steps, frame or oor may be wet
and/or slippery.
7. Do not allow personnel that are taking drugs,
alcohol or any medications that impair the
senses or when excessively tired or stressed
to operate the Heater.
8. Do not operate unit in a poorly ventilated or
enclosed area to prevent asphyxiation when
the heaters are operating.
9. Do not smoke when connecting fuel source or
when working around machine.
10. Always wear heavy gloves when working on
the machine to prevent burns when touching
hot components.
11. Use the foot pedal switch to engage the hose
reel take up or extend function and guide the
hose by hand.
12. Keep all electrical lines and components in
good working order. Do not operate in wet
conditions or when standing in water. Damp
or wet conditions can cause shocks or trip the
breakers.
13. Keep all components in good condition.
14.Do Not plug or block access doors or vents.
Keep 1 foot of clearance around unit.
15. Review safety instructions with operators
annually.

10
SAFE TRANSPORTATION AND STORAGE
When transporting the machine, review and follow
these instructions:
1. Be sure all bystanders are clear of the machine.
2. Back the truck up to the hitch and lower hitch
over the ball.
3. Secure with a mechanical retainer.
1. Attach to towing vehicle and secure with a me-
chanical retainer. Cross the safety chains under
the hitch and anchor to truck frame.
2. Connect the brake anchor cable to the truck
frame to activate the trailer brakes if the trailer
unexpectedly unhooks. Provide sufcient slack
for turning.
3. Check that all lights and reectors required by
the DOT are clean and functioning.
4. Do not exceed 55 mph under ideal conditions.
5. Do not allow riders on machine.
6. Do not drink and drive.
TRANSPORTING SAFETY
TRAILER TOWING CAN
BE HAZARDOUS
WARNING
* DO NOT exceed 55 mph under ideal
conditions
* Reduce speed under adverse
weather, road or terrain conditions
* Avoid sudden lane changes, U-turns
etc.
* Sudden maneuvers may cause
tipping, rollover, jackkning or sliding
of the trailer and without warning loss
of control of the towing vehicle may
result.
* Allow for increased braking distance
due to weight of trailer
* Read the Operator's Manual before
towing.
4. Cross the safety chains under the hitch and at-
tach to truck frame.
5. Attach the brake line to the truck frame. Be sure
to leave sufcient slack for turning.
6. Connect electrical harness to truck plug-in.
7. Raise and secure the hitch jack.
8. Reverse the Heat King set-up procedure.
9. Check and be sure that all lights are working.
10. Do not allow riders on machine.
11. Never exceed a safe travel speed.
12. Do not drink and drive.
13. Check with local highway authorities on the
specic requirements for transporting fuel oil
through their jurisdiction. Always comply with the
requirements before transporting.

11
1. Store unit in an area away from human activity.
2. Do not permit children to play on or around the
stored Heater.
STORAGE SAFETY
PLACING IN STORAGE
After the season's use, the machine should be thor-
oughly inspected and prepared for storage. Repair
or replace any worn or damaged components to
prevent any unnecessary down time at the start of
next season. To insure a long, trouble free life, this
procedure should be followed when preparing the
unit for storage:
1. Clear the area of bystanders, especially small
children.
2. Thoroughly wash the machine using a pres-
sure washer to remove all dirt, mud, debris and
residue.
3. Inspect the hoses and burners for damage.
Repair or replace damaged parts. Remove all
entangled material.
4. Drain and remove the diesel fuel from the tank
whenever the unit will be stored for more than
30 days. Removing the fuel during storage
eliminates the formation of organic matter in the
system and prevents leaks. Always rell the
tank before its next use.
5. Lubricate all grease ttings. Make sure that all
grease cavities have been lled with grease to
remove any water residue from the washing.
6. Touch up all paint nicks and scratches to pre-
vent rusting.
7. Move to storage area.
8. Select an area that is dry, level and free of de-
bris.
9. Place blocks under the hitch if required.
10. Padlock each door.
11. Unhook from tow unit
12. If the machine cannot be placed inside, cover
with a waterproof tarpaulin and tie securely in
place.
13. Store the machine in an area away from human
activity.
14. Do not allow children to play on or around the
stored machine.

12
INTRODUCTION
Congratulations on your choice of a Tamarack Industries Heat King HK300B to complement
your construction operation. This equipment has been designed and manufactured to meet
the needs of the buyer for the efcient heating of construction sites.
Safe, efcient and trouble free operation of your HK300B requires that you and anyone else
who will be operating or maintaining the Heater, read and understand the Safety, Operation,
Maintenance and Trouble Shooting information contained in the Operator's Manual.
This manual is applicable to the HK300B built by Tamarack Industries. Use the Table of
Contents as a guide when searching for specic information.
Keep this manual handy for frequent reference and to pass on to new operators or own-
ers. Call your Heat King distributor or customer service if you need assistance or informa-
tion at 1-800-661-0304

13
SIGN-OFF FORM
Tamarack Industries follows the general Safety Standards specied by the Society of Automotive Engi-
neers (SAE) and the Occupational Safety and Health Administration (OSHA). Anyone who will be operat-
ing and/or maintaining the Heat King must read and clearly understand ALL Safety, Operating and Mainte-
nance information presented in this manual.
Do not operate or allow anyone else to operate this equipment until such information has been reviewed.
Annually review this information before the season start-up.
Make these periodic reviews of SAFETY and OPERATION a standard practice for all of your equipment.
We feel that an untrained operator is unqualied to operate this machine.
A sign-off sheet is provided for your record keeping to show that all personnel who will be working with the
equipment have read and understand the information in the Operator’s Manual and have been instructed
in the operation of the equipment.
DATE EMPLOYEES SIGNATURE EMPLOYERS SIGNATURE
SIGN-OFF FORM

14
VIN NUMBER LOCATION
Always give your dealer, distributor or factory the serial number of your Heat King when ordering parts or
requesting service or other information.
The serial number plate is located inside the front frame where indicated and the VIN plate is located on
the front left corner of the frame. Please mark the number in the space provided for easy reference.
MODEL
VIN NUMBER
Vehicle Identication Number
HK300B

15
Date Dealer’s Rep. Signature
The above equipment and Operator’s Manual have been received by me and I have been thoroughly
instructed as to care, adjustments, safe operation and applicable warranty policy.
Date Owner's Signature
TAMARACK INDUSTRIES
HEAT KING
WARRANTY REGISTRATION FORM & INSPECTION REPORT
DISTRIBUTOR INSPECTION REPORT
SAFETY
Emergency Stop Switch Works
All Decals Installed and Legible
Lights and Reectors Installed,
Clean and Working
Review Operating And
Safety Instructions
WARRANTY REGISTRATION (please print)
This form must be lled out by the dealer and signed by both the dealer and the customer at the time of deliv-
ery.
Customer’s Name Distributor Name
Address Address
City, State, Code City, State, Code
Phone Number ( ) Check One:
Contact Name Private
Heat King Model Contractor
Serial Number Other
Delivery Date
I have thoroughly instructed the buyer on the above described equipment which review included the Op-
erator’s Manual content, equipment care, adjustments, safe operation and applicable warranty policy.
Tire Pressure Checked
Wheel Bolts Torqued
Brakes Work
Check Fluid Levels (Fuel and Glycol)
Lubricate Machine
Check That All Controls Function

16
Tamarack Industries CONDITIONS OF SALES & LIMITED WARRANTY
All sales made by Tamarack Industries, here after ref-
ered to as Tamarack, a Division of ELJO Industries Inc.
are subject to these conditions unless otherwise agreed
in writing with a duly authorized ofcer of Tamarack. In
all cases of conict between these conditions and the
requirements of the purchase order, these conditions
shall prevail.
(1) SALES POLICY: Nothing herein shall be construed
as abridging the right of Tamarack to sell directly or indi-
rectly to: (a) Federal, State or Provincial Governments
or Agencies thereof, or to Agencies employing Federal,
State or Provincial Government aid; (b) Purchasers
who buy Tamarack's products for sale as integral or as-
sembled parts of their products; (c) Firms operating on a
national scale; (d) Any other class of purchaser to whom
Tamarack may from time to time, elect to sell.
(2) PRICES: All prices are F.O.B. our warehouses,
freight allowance as specied on Distributor Net Price
Lists. The suggested list prices and discounts schedules
are established by Tamarack and are intended to act as
a guide for our distributors. Unless otherwise stated in
writing, prices are subject to change without notice and
will be applied as in effect at time of shipment.
(3) TERMS: Unless otherwise agreed upon in writing by
an ofcer of Tamarack, all invoices become due and pay-
able net 30 days following the date in invoice. Interest
at the maximum legal rate will be charged on all overdue
accounts. Minimum net charge per invoice is $75.00
(4) CANCELLATION AND CHANGES: No orders or
sales may be cancelled or changed without the consent
of Tamarack. At Tamarack's option cancelled/changed
orders are subject to payment of cancellation charges
equal to all costs incurred by Tamarack up to the date
of cancellation/change.
(5) DELAYED DELIVERIES: Tamarack shall not be
liable for any delay of merchandise for any cause what-
soever.
(6) CLAIMS: All goods shall be deemed delivered to pur-
chaser at the time they are placed in the hands of carrier
and consigned to purchaser: loss, damage or destruc-
tion of any said merchandise is assumed by purchaser.
No claims may be made for shortages unless made in
writing within ten days from receipt of merchandise.
(7) RETURN OF GOODS: Written permission from
Tamarack must be obtained before returning any mer-
chandise. All transportation charges must be borne by
the purchaser. Credit for returned goods will be based
on the original price paid, less 20%. Special parts or
custom-built items cannot be returned for credit.
(8) LIMITATION OF LIABILITY: Tamarack's liability on
any claim of any kind, including negligence, for any loss
or damage arising out of, connected with, or resulting
from contract, or the performance or breach thereof, or
the design, manufacture, sale, delivery, resale, installa-
tion, technical direction of installation, inspection, repair,
operation or use of any equipment covered by or fur-
nished under contract shall in no case exceed the price
paid by the purchaser for the equipment. Tamarack also
disclaims all purchaser for the equipment. Tamarack
also disclaims all liability, whether in contract, tort, war-
ranty, or otherwise, to any party other than purchaser.
(9) All Price Lists, Catalogues and other material shall re-
main the property of Tamarack and are subject to return
on demand. The Suggested List Prices are established
by Tamarack and are intended to act as a guide. All
shipping weights shown are approximate.
LIMITED TAMARACK WARRANTY
For one year from date of purchase, Tamarack will re-
place or repair for the original purchaser, free of charge,
any part or parts, found upon examination by any
Tamarack Authorized Service Depot or by the Tamarack
factory, to be defective in material or workmanship or
both. Equipment and accessories not manufactured
by Tamarack are warranted only to the extent of the
original manufacturer's warranty. All transportation
charges on parts submitted for replacement or repair
under this warranty must be borne by the purchaser.
For warranty service contact your nearest Tamarack
Authorized Service Depot.
THERE IS NO OTHER EXPRESS WARRANTY,
IMPLIED WARRANTIES, INCLUDING THOSE OF
MERCHANTABILITY AND FITNESS FOR A PARTICU-
LAR PURPOSE ARE LIMITED TO ONE YEAR FROM
PURCHASE AND TO THE EXTENT PERMITTED BY
LAW. LIABILITY FOR CONSEQUENTIAL DAMAGES
UNDER ANY AND ALL WARRANTIES ARE EXCLUD-
ED TO THE EXTENT EXCLUSION IS PERMITTED BY
LAW. (THIS WARRANTY IS AN ADDITION TO ANY
STATUTORY WARRANTY.)
P.O. Box 234, Station "L"
Winnipeg, Manitoba
Canada R3H 0Z5
WARRANTY VOID IF NOT REGISTERED

17
How It Works
The Heat King HK300B unit is designed to heat a propylene glycol water solution
which is then used for ground thawing, concrete curing or space heating. The glycol
solution is pumped out of its storage reservoir and heated in a high capacity heat
exchanger and returned to the reservoir until it reaches a user settable temperature.
The heat exchanger is a coiled pipe with a Diesel red burner. The reservoir is open
to atmosphere.
A eld pump draws the hot solution out of the reservoir and pumps it to the eld loop
for heating the area as required. There are supply and return manifolds on the back
of the unit. Heated solution is then pumped to the supply manifold, through the
hoses and back to the return manifold.The solution is then returned to the reservoir
for reheating. Controls panels hold the electronics and user controls.
HOW THE MACHINE WORKS
GLYCOL RESERVOIR
Circulating Pump
Heat
Exchanger
Burner
Pressure switch
Level switch
Safety Temp. switch Field
Supply manifold
Return manifold
Heating loops
Field Pump
TRAILER
NG/LP
Supply

18
The HK300B is equipped with the following protective
devices to protect the user and the machine:
Emergency stop switch
The emergency stop switch is monitored by the controller inputs. The input is connected to
ground when the switch is pressed. In the event of an e-stop condition the system mode is set to
OFF and all output functions are shut down by the controller.
Pressure Switch
The pressure switch is designed to protect the burners and burner coils in the even of a pump
failure. The pressure switch is a normally open switch that closes when senses 12PSI from the
pump. If the switch does not sense pressure it wont allow power to go to the burners.
Low Water Cut Off Switch
The low water cut off switch is in place to protect the burners and burner coils as well as the
circulating pumps in the unlikely event of loss of glycol. If the glycol goes down below the switch
level, the switch contacts will close and shut off power to the pumps and burners to avoid dam-
age.
High Limit Switch (aquastat)
The high limit switch is in place to be a backup to the other safety devices. It is an analog switch
that is set to 230°F, there is one on each coil. In the event that the burner coil was to heat up
past the user set point the High limit switch cuts the power to the burner to avoid overheating of
the coil.
Protective Devices

19
Controls
A
C
B
E
D
F G
H I
J
K L M
N O
P Q
Before starting the unit , all operators should familiarize them-
selves with the location and function of the controls.

20
A. Digital Display:
This system monitors the temperature of the
glycol in the reservoir and entering the circula-
tion manifold. It is shown on the digital display.
B. Return Temperature:
This gage monitors and displays the tempera-
ture of the glycol in the return manifold. It func-
tions only when the eld pump is running.
C. Total Operating Time:
This hour meter displays the total time that
power is provided to the heater loop.
D. Circuit Breaker:
Under normal operation, circuit breaker is de-
pressed. If circuit breaker load is exceeded, it
will trip the breaker and extend.
E. Ground Fault Interrupter:
This interrupter circuit monitors the power ow
through the system and trips or breaks the cir-
cuit when there is a ground or short. Correct
the condition, depress the red button to reset
interrupter and resume work.
F. Circuit Power:
This 2 position rotary switch controls the power
to circuit. Turn the switch clockwise to turn the
power to circuit on and counterclockwise for off.
The circuit power light will come on when the
power is turned on. The burner oil preheater
comes on to preheat the nozzle.
G. Hose Reel Direction:
This 2 position rotary switch selects the direc-
tion of hose reel operation. Turn the switch fully
clockwise to extend the hose and counterclock-
wise for retracting.
H. Hose Reel/Field Loop Selector Switch:
This 3 position rotary switch selects the system
that will be supplied with power. Turn fully coun-
terclockwise to select the hose reel system.
Move the switch to its vertical position to turn
off. Turn fully clockwise to provide power to the
eld loop system. In this position, the eld pump
light will come on.
I. Compressor/Heater Loop Selector Switch:
This 3 position rotary switch selects the system
that will be supplied with power. Turn fully coun-
terclockwise to select the (compressor system).
When this system is turned on, the compressor
light will come on. Move the switch to the vertical
position to turn off. Turn fully clockwise to turn
the heater loop circuit on. When this system is
turned on, the burner start-up sequence starts.
First, the circulation pump light comes on as
the pump starts. Then the burner igniter starts.
When that burner is operating, the burner ame
light comes on.
J. Emergency Stop:
This 2 position push-pull switch controls the
power to the machine. Push the switch in to stop
all machine functions and pull out to provide
power. It is recommended that all controls be
placed in their off position before the switch is
pulled out and power restored.
K. Circuit Power:
This light comes on when the power is turned on
and everything is functioning normally. It goes
out when the breaker or interrupter trips or the
power is turned off.
L. Circulation Pump:
This light comes on when the burner coil cir-
culation pump is on, and the pump is creating
pressure, and goes out when the pump is off.
M. Burner Flame:
This light comes on when the main burner is on.
The light goes out when the main ame goes
out.Light is not on when pilot is lit.
N. Field Pump:
This light comes on when the eld pump is
turned on and goes out when the pump is off.
O. Compressor:
This light comes on when there is power to the
compressor and goes out when the power is off.
Warning Indicators:
P. Low Glycol:
This left red light comes on when the glycol
reservoir level goes below the switch level
and goes off when the level is above. Stop
unit immediately and add glycol to the reser-
voir when this light comes on. Do not over
ll reservoir.
Q.Overtemp:
This right red light come on when the burners
are on with no call for heat.
Table of contents
Popular Heating System manuals by other brands

Nibe
Nibe UKV 20-220 Installation and operating manual

Immergas
Immergas BASIC MAGIS PRO Instructions and warnings

Iloxair
Iloxair ILOX 129 Installation, operation and maintenance guide

NEXGEN
NEXGEN IMPULSE 100L Operations manual & parts list

Okofen
Okofen PE 08 operating manual

Roberts Gorden
Roberts Gorden CRV-Series Installation & operation

Etherma
Etherma EZ-800 Installation and operating instructions

Miller
Miller 907689 owner's manual

Hotstart
Hotstart OXM Installation & operation manual

GammaSwiss
GammaSwiss RoofMate Assembly, installation and operation instructions

Innova
Innova EF40 Series Installation, instruction and service manual

Frico
Frico Thermowarm TWT100 (IP44) Original instructions