© Copyright (2021) All rights reserved. Changes, which serve technical improvements are reserved.
10
PRSU/4, PRSU/5 Operating Instructions Manual (Revision 3.0)
Maximum Short Circuit Resistance
Maximum Signal Wires Resistance
2 x 1.5 mm2solid wire
2 x 1.5 mm2stranded wire-end ferrule
UL: Use 60/75°C copper wire only!
2 x 1.5 mm2solid wire
2 x 1.5 mm2stranded wire-end ferrule
UL: Use 60/75°C copper wire only!
Max. Conductor Length (input circuit)
2 x 100m (Single channel)
4 x 100m (Dual channel)
2 x 100m (Single channel)
4 x 100m (Dual channel)
3 N.O. safety, 1 N.C. aux
3 N.O. safety, 1 N.C. aux
AgSnO2or comparable material
AgSnO2or comparable material
Max. Switch/Relay Current
5A (individual), 3.8A (combined)
5A (individual), 3.8A (combined)
Max. Switching Capability (per relay)
DIN EN 60947-5-1
AC 15 230 V / 5 A
DC 13 24 V / 5 A
AC 15 230 V / 5 A
DC 13 24 V / 5 A
105switching cycles (DC 24V/2A)
105switching cycles (DC 24V/2A)
Creeping Distance and
Clearance
-EN 50178 at pollution grade 2, over voltage
category 3 /250V
-Basis isolation: over voltage
category 3 / 250 V
-EN 50178 at pollution grade 2, over voltage
category 3 /250V
-Basis isolation: over voltage
category 3 / 250 V
NO contact: 6.3A brief
NC contact: 4A gL/gG
NO contact: 6.3A brief
NC contact: 4A gL/gG
Short Circuit Withstand
(IEC60947-5-1)
Weld Free Protection at IPSCC≥1kA SCPD
(Short Circuit Protection Device)
(Fuse links), size D01
acc IEC IEC60269-1; IEC60269-3-1; VDE036-
T301
NO-contacts: 6A
NC-contacts: 6A
NO-contacts: 6A
NC-contacts: 6A
Restarting Readiness Time (minimum switch off
time the inputs)
Click-fastening for DIN-Rail
Click-fastening for DIN-Rail
Torque Setting for Connection Terminals
0.5 Nm (min), 0.6 Nm (max)
UL: Overtorquing may cause
enclosure breakage
0.5 Nm (min), 0.6 Nm (max)
UL: Overtorquing may cause
enclosure breakage
-25°C ... +55°C ( UL:…+40°C)
-25°C ... +55°C ( UL:…+40°C)
Shock Resistance of N.O./N.C. Contacts
Performance Level e, Cat. 3
Performance Level e, Cat. 3
90% (Medium - redundant switch off channel
with monitoring)
90% (Medium - redundant switch off channel
with monitoring)